Home

Aube Technologies TH110A-SP-P User's Manual

image

Contents

1. 3 seconds to select every day of the week 3 Press on Hour and Min buttons to enter 6 15 AM Prog 1 CG 4 Press on PGM button to select Prog 2 q and Hour and Min buttons to enter 8 15 AM 5 Repeat step 4 to enter Prog 3 5 00 PM and Prog 4 10 00 PM NOTE When making modifications make sure you are in the right program To modify the Saturday and Sunday schedules 6 Press on Day button until SA or SU is displayed 7 Press on PGM button to select Prog 1 Eos and Hour and Min buttons to enter 7 30 AM 8 Press on PGM button to select Prog 2 q and then Clear button to erase it 9 Press on PGM button to select Prog 3 30 and then Clear button to erase it 10 Press on PGM button to select Prog 4 q and then Hour and Min buttons to enter 11 00 PM 11 Press on Mode button to exit this function 920 110 001 00 1 B 2 3 Temporary or permanent temperature bypass This operation allows you to temporarily modify the room temperature while you are in the Automatic mode Simply press on or W button to select the desired temperature or the X or button to select the Comfort or Econo settings you have programmed This temperature will be maintained until the beginning of the next programmed schedule You can also switch to the Vacation setting for a prolonged absence by pressing on x and atthe same time The display will show iil icon In that case the derogation is permanent To return to th
2. LN INSTALLATION NOTE The Problems and Solutions section at the end of this user s guide will help you to correct your problems during the installation technologies This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding 2400 W 20 A 120 VAC such as electric baseboards radiant ceilings and floors electric con MODEL TH110A SP P 1 20 V vectors etc It is not compatible with a low voltage controller used by a central heating system Electricians or experienced technicians should install the thermostat SUMMARY This thermostat is designed to be used with a self protected heating OPTIONS SELECTION system equipped with thermal cut off and circuit breaker At the back of the thermostat there are three selection switches to set at your preferences PARTS INCLUDED Temperature in C or F time in 12 or 24 hours and Early Start function One 1 TH110A SP P 120 VAC thermostat TO SET TIME AND DAY Two 2 6 32 screws Press on DAY HOUR and MIN buttons to adjust time and day Four 4 solderless connectors for copper wire TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK Keep air vents of the thermostat clean and free from obstructions TO RECORD THE gt COMFORT SETPOINT TEMPERATURE Select chosen setpoint temperature by using or W button Press on 30 button 2 to 3 seconds until icon appears on display TO RECO
3. RD THE ECONOMY SETPOINT TEMPERATURE Select chosen setpoint temperature by using or W button 1 Connecting wires and mounting thermostat Press on button 2 to 3 seconds until icon appears on display Connect the rear thermostat wires to the 120 V LINE and to the load using TO RECORD THE i VACATION SETPOINT TEMPERATURE solderless connectors for copper wires See schematic diagram To program the Vacation temperature select the desired degree using the V buttons and press on the X and buttons simultaneously Push the excess wire back into the electrical box to prevent interference with the until the ji icon is displayed app 3 seconds thermostat Secure the thermostat using two 2 6 32 screws Once the thermostat is properly installed return power to heating system OPERATING MODES To select an operating mode use MODE button AUTO Runs the program or w shows temperature setting BEFORE SUPPLY AFTER and can override temporarily your programming up to the next program 120 V LINE Maintains the selected temperature or w changes OLD TU the temperature setting THERMOSTAT al a a SS BLACK N TUTTO BLACK l 120 VAC f CEE n a an 3 a HZ Thermostat THI10A SP P Room or setting temperature 2400 W NI 120 Vca AS Time and day A e A D of the week NOTE All cables and connections must conform to the local
4. ay button for 3 seconds 3 Press on PGM button to select program 1 2 3 or 4 4 Press on Hour and Min buttons to program the time 5 When you have completed your programming press on Mode button to exit this function b To Erase a Program Select the program using PGM and Day buttons and press on Clear button The time field displays when the program is inactive c Example 1 Comfort period from 7 00 AM to 10 30 PM Economy period from 10 30 PM to 7 00 AM Identical schedule for all days of the week 1 Press on PGM button to access the programming mode 2 Press on Day button 3 seconds to select every day of the week 3 Press on Hour button to enter 7 00 AM Prog 1 lt 0 4 Press on PGM button again to select Prog 2 q and press on Hour and Min buttons to enter 10 30 PM 5 Press on Mode button to exit this function d Example 2 Comfort period Monday to Friday from 6 15 AM to 8 15 AM and from 5 00 PM to 10 00 PM Saturday amp Sunday from 7 30 AM to 11 00 PM Schedule Day MON TUES WED THU FRI SAT SUN PROG 1 X 6 15 AM 6 15 AM 7 PROG 2 PROG 3 X PROG 4 10pm 10PMm 10PM 10PM 10PM 11PM 11PM Program Mode Time 1 Wake up time 2 Departure time 3 Return time 4 Bed time NOTE t is faster to program the same schedule for every day and then modify the exception days 1 Press on PGM button to access the programming mode 2 Press on Day button
5. displays heating e Bad installation but heating system is not turned on e Check actual time in AM amp PM as well as program times AM is not displayed e Make sure operating mode is set to AUTO Programs do not change as you want e Incorrect programming hours e Wrong programming mode selected 01 04 02 920 110 001 00 1 B 3 3
6. e normal operating mode press on Mode button If you wish to immediately return to the programmed settings press on Mode button twice CHARACTERISTICS e Model e Supply e Load e Power e Approvals e Display range e Setting range Comfort default setting Econo default setting e Vacation default setting TH110A SP P 120 VAC 120 VAC 50 60 Hz 20 A maximum resistive only 2400 watts NI 120 VAC CSA UL 0 to 60 C 32 to 140 F 5 to 30 C 40 to 85 F 20 C 68 F 18 C 64 F 10 C 50 F WARRANTY AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year from the date of the original purchase from authorized dealers During this period AUBE technologies inc will repair or replace the product with a new or of equivalent quality at AUBE S option without charge any product proven defective in normal use Warranty does not cover transportation costs Nor does it cover a product subjected to misuse or accidental damage This warranty does not cover the cost of installation removal or reinstallation This limited warranty is in lieu of all other warranties obligations or liabilities expressed or implied by the company In no event shall AUBE technologies inc be liable for consequential or incidental damages resulting from installation of this product Some states or pr
7. electrical code Comfort Economy MOTUWETH mirig WARNING Special CO ALR solderless connectors must be used when amp Vacation temperature settings t p F connecting with aluminum conductors Operati des C perating modes gt fb Q a Power up Program number gt fif SS 7 soe oe Set the On Stand by switch to On Hour gi Heating indicator 11 ENNA To set the time To set the A pom programming Comfort temperature _ gt X q cker 4 To erase a program mel lt q To select the operating mode When power is applied for the first time the display must show the time 00 00 the room temperature and the Manual mode icon m Other information might show up on the display if installation is defective or does not comply with the instructions Economy temperature Vv NOTE The On Stand by switch set to Stand by will place the thermostat in sleep mode Ideal for summertime A Up amp down to adjust the temperature setting 920 110 001 00 1 B 1 3 OPERATING MODES The TH110A SP P has two 2 operating modes MANUAL Wa This mode allows you to maintain a constant temperature in the room 1 To activate this mode press on Mode button to display the 4 icon 2 Set the desired temperature usin
8. g the 4 W buttons or select the pre programmed X K or till settings To select the tii setting press on 4 and simultaneously AUTOmatic This mode executes your own programming To activate this mode press on Mode button to display the O icon The X or icon indicates which temperature setting is used Also the icon of the program number will be shown Memory back up In the event of a power failure an internal circuit will maintain the programming and the time But only the time could have to be set if power failure is more than 2 hours Early Start function The thermostat is providing a built in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time This function could start the heating system as early as 6 hours prior to the programmed time To enable this function set the switch E S to ON at the back of the thermostat PROGRAMMING Programming the time and day 1 Set the time using the Hour and Min buttons 2 Set the day using the Day button Programming the Comfort Economy and Vacation settings The Comfort X Economy q and Vacation til settings respectively represent the temperatures that you wish to have during the day 3 at night or while you are away at work or while you are away for an extended period Mm To program your settings a To program the Comfort temperature select the desired de
9. gree using the 4 V buttons and press the X button until the X icon is displayed app 3 seconds b To program the Economy temperature select the desired degree using the 4 WV buttons and press the button until the icon is displayed app 3 seconds c To program the Vacation temperature select the desired degree using the 4 buttons and press on the 34 and buttons simultaneously until the m icon is displayed app 3 seconds d Press the Mode button to exit this function and return to the normal operating mode Schedule programming The TH110A SP P allows 4 setting changes for each day of the week There are no pre set programs The programs are tailored to perfectly adapt to your life style The principle is very simple For each day enter the time at which you wake up P1 the time you leave for work P2 the time you arrive back home P3 and the time you go to bed P4 For savings to be obtained you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level Example f your system takes one hour to go from your saving temperature level to your comfort temperature level it is useless to lower the temperature for a period less than 2 to 3 hours a To Program your Schedule 1 Press on PGM button to access the programming mode 2 Press on Day button to select the day to be programmed You can select all days of the week by pressing on D
10. ovinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state The defective product and the original sale receipt must be returned to the original dealer or shipped pre paid insured and addressed to Aube technologies inc 705 Montrichard Iberville Quebec Canada J2X 5K8 www aubetech com service aubetech com If you have any questions concerning the installation or programming of this product please call our technical assistance at 450 358 4600 for the Montreal area or 1 800 831 AUBE for outside area Monday to Friday between e Storage 20 to 50 C 4 to 120 F 8 30 AM and 5 00 PM Eastern time PROBLEMS AND SOLUTIONS PROBLEMS CAUSES SOLUTIONS No display e Circuit breaker is open Check 120 VAC presence e Power failure e The thermostat switch is in Stand by position at the thermostat e Put the switch in On position The thermostat is loosing e Power failure more than the time but not the programming 2 hours Room temperature shown is wrong e A draft is nearby the thermostat e Eliminate the draft Heating system always on e Bad installation e Check installation e Check installation Check 120 VAC presence at the heating system The thermostat

Download Pdf Manuals

image

Related Search

Related Contents

Travaux à proximité des lignes électriques aériennes  デジスパイス取扱説明書  KDC-4547U KDC-4047U KDC-4047UGY KDC    SurroundTraxx User`s Guide  Numark Industries RM6 Musical Instrument User Manual  HTS Express - Hi-Tech Software, Inc  Mode d`emploi de la Banque  MF 16 CENTRALE MULTIZONA PER LA RIVELAZIONE  SOUNDLINK®  

Copyright © All rights reserved.
Failed to retrieve file