Home
ATD Tools ATD 109 User's Manual
Contents
1. HINGE 4 PIN HINGE RETAINING RING SPRING TUBE PIVU BLUCK CAM CAM_SPRING 11 64 DIA BALL BEARING WIRE RING LOAD SPRING THRUST WASHER SPACER POINTER SCREW 4 40 UNC X 5 16 BALL STOP SPRING TUBE INSERT 4 KNOB SPRING ADJUSTING SCREW LENS ALUMINUM HAND GRIP 8 32 UNC X 3 16 18 855 BHCS 3 16 DIA BALL BEARING ADJUSTING KNOB END CAP SCREW RATCHET CAP 4 REVERSING RING ASSEMBLY REVERSING SPRING 4 RETAINER DRIVE ASSEMBLY RATCHET REPAIR KIT RATCHET ASSEMBLY 19 20 21 a T m m oO 7 gt CT4600F KK ATB 10 11 12 13 14
2. FEATURES Audible click and or impulse when torque setting is reached 4 clockwise accuracy between 20 100 of range Complies with American Standard ANSI ASME B107 14M International Standard ISO 6789 Large easy to read torque scale Ball bearing mechanism provides extended calibration accuracy Anodized aluminum handle with no slip diamond Detent style adjustment locking prevents accidental change of torque setting Chrome plated hardened steel body Factory calibration tape supplied with each tool Packaged in protective blow molded storage case SUGGESTIONS Proper use of this professional torque wrench will give you complete satisfaction in its performance and reliability Following are some helpful tips 1 Accuracy is assured by gripping the wrench properly Grasp the GRIP not the SHAFT and pull smoothly 2 Each torque wrench is lubricated before leaving the factory If it has not been used for some time it should be operated several times to re distribute the lubricant within the working mechanism 3 Never attempt to turn the KNOB when the KNOB is in the LOCK position 4 Never set for higher or lower torque values than those indicated on your wrench 5 For greater accuracy clean all thread surfaces and remove any burrs on the fasteners being used 6 WARNING never use your torque wrench to apply more torque than its rated capacity 7
3. Itis not necessary to return this wrench to its lowest calibrated value after use unless it is to be stored for an extended period of time DO NOT OVERTORQUE CERTIFICATION This torque wrench was calibrated prior to shipment from the factory within tolerance limits of 4 clockwise right handed accuracy of upper 80 of range LIMITED WARRANTY Until one year from the date of purchase we will repair any defect in material or workmanship free of charge Improper use of these products including but not limited to the application of excessive force will affect performance and may result in injury The warranty does not apply to wrenches which do not function properly or within specified accuracy because of wear improper or unreasonable use damage not resulting from defect or malfunction or which have been altered Calibration is warranted for 90 days This warranty gives you specific legal rights and you may also have other rights which vary from state to state For repair or calibration send wrench postage prepaid to IN THE U S A Angle Repair amp Calibration 175 Angle Drive Beckley WV 25801 972 864 6762 IN CANADA ATG Torque Repair 7631 Bath Road Mississauga ON L4T3T1 1 866 691 6212 REVISED PRINTED IN USA APR 2014 FORM CT600 61D ATD 109 MICROMETER ADJUSTING TORQUE WRENCH OPERATING INSTRUCTIONS ADJUSTING YOUR MICROMETER TORQUE WRENCH Caution Do not turn the adjusting knob with the kn
4. ob the locked position Damage to the locking mechanism may occur P 7 1 The minor scale is located the 0 adjusting knob One SS revolution of the Knob advances the major scale located in the grip window by one Increment 2 To adjust the torque setting push the adjusting knob toward the grip until it unlocks and turn it to Nm the right to increase SS the torque setting and to the left to reduce it 3 To set 362 5 ft lbs for we example turn the adjusting knob until the red indicator in the major scale window Is aligned with the closest major lbf ft increment at or below the target torque setting and the knob is aligned on zero Note Lbf ft units are on the right side of the window and Nm units are on the left side amp 4 Turn the knob Boe additional 5 increments to set it on 12 5 and release it to lock the torque setting The two scales added 2 14 together give 362 5 ft ss los For Nm settings use the lower scale on the knob TORQUE UNIT CONVERSIONS Torque values can be converted to other units very easily with simple multiplication To convert torque values from one unit to another multiply the value of the given torque unit by the correct conversion factor to get the desired torque value Inch Pounds x 08333 Foot Po
5. ocedure will result in a change of torque being applied DO NOT USE universal joints or universal sockets due to the complexity of determining the associated error EXTENSIONS When necessary to use an extension that changes the lever length of the torque wrench torque being applied will change To compute the wrench setting Wrench Setting Desired Torque x L HL NOTE Socket extension bars that are axially in line with the square drive do not cause error and need no adjustment 10 11 12 13 14 15 or _ we aaa O wa wa da 11 _ 11 12 CT4600F KKAT 12 a ae EE eee eer eee TO 14 DRAWING NUMBER 13 14 17 ATD 109 ITEM PART DESCRIPTION _1_ 1 6356 01 56354 23 3 WWW gt 0 SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES 15 005 16 1390 01 54400 01 91100 10 54100 09 54100 06 01164 07 5400 29 64600 08 54400 28 54400 44 54400 10 42000 15 80023 15 6354 46 6354 05 64002 32 34401 06 54402 24D 544 11 54100 15 01264 07 640F N 03 31000 31 80010 80 6355 25 6355 73 6355 07 6356 06 6356 70 6356 75 6356 60 NOTICE UNAUTHORIZED USE
6. unds Meter Kilograms f x 7 233 Foot Pounds MAJOR SCALE KNURLED GRIP SCALE INDEX MINOR SCALE ADJUSTING HOW TO APPLY TORQUE This Micrometer Adjustable Torque Wrench when properly used is designed to provide an audible signal and or impulse feel to indicate the desired torque has been applied DO NOT pull beyond this point CAUTION The audible signal or impulse feel is an indicator that the proper torque has been attained Over torquing beyond these signals could cause fastener failure ADDITIONALLY When the wrench is set at the low end of the torque range the degree of signal and impulse will be less than when set at the high end of the range Therefore care must be taken at the low end of scale to hear the signal or feel the impulse To properly apply torque attach a socket securely on the torque wrench square drive and position the socket on the fastener so that tilting will not occur Grasp the center of the hand grip and apply a slow steadily increasing force perpendicular 90 degrees to the torque wrench body and perpendicular to the center line of the square drive socket and fastener Turn the fastener down with a smooth and even force applied to the handle of the torque wrench As turning resistance increases pull more slowly To assure accuracy the fastener must be in motion when the torque measurement is made WARNING Any change from the above pr