1. C 3 0 5 digits 400 0 mVDC 0 8 3 digits 4 000 VDC DC Voltage sooo 1 5 3 digits 600 VDC 2 0 3 digits 400 0 mVAC 0 8 20 digits 4 000 VAC AC Voltage 40 00 VAC 1 8 5 digits 400 0 VAC 600 VAC 2 5 5 digits 400 0 2 1 0 4 digits 4 000K Q Resistance aK 1 5 2 digits 4 000M 2 2 5 3 digits 40 00M 2 3 5 5 digits Capacitance 40 00nF 5 0 reading 100 digits 400 0nF 3 0 reading 5 digits eoa z 3 5 reading 5 digits 100 0 u F 5 0 reading 5 digits Frequency 5 000Hz 1 5 reading 5 digits 50 00Hz 1 2 reading 2 digits 500 0Hz Sensitivity 10Vrms min 5 000kHz 50 00kHz 100 0kHz Duty Cycle 0 5 to 99 0 1 2 reading 2 digits Pulse width 100yus 100ms Frequency 5 000Hz 100 0kHz Temp type K 20 to 1000 C 3 0 reading 5 C Steud 4 to 1832 F 3 0 reading 7 F Note No Autoranging amp 400mV AC Voltage Range Clamp size Opening 1 2 30mm ap prox DC AC Current Measurements WARNING Ensure that the test leads are disconnected from the meter before making current clamp measurements 1 Set the Function switch to the 1000A or400A or 40A range If the range of the measured is not known select the higher range first then move to the lower range if necessary 2 Select AC or DC with the MODE button 3 Press the trigger to open jaw Fully enclose over one conductor wire to be measured 4 The clam
2. Model 5597 OPERATING INSTRUCTIONS 1000A DC AC CLAMP METER Safety International Safety Symbols A This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information A This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Cl Double insulation SAFETY NOTES e Do not exceed the maximum allowable input range of any function e Do not apply voltage to meter when resistance function is selected e Set the function switch OFF when the meter is not in use WARNINGS e Set function switch to the appropriate position before measuring e When measuring volts do not switch to current resistance modes e Do not measure current on a circuit whose voltage exceeds 240V e When changing ranges using the selector switch always disconnect the test leads from the circuit under test e Donot exceed the maximum rated input limits CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC These voltages are considered a shock hazard Remove the battery if the me
3. attery NEDA1604 6F22 006P 4 Re assemble the meter Warranty Information This product is warranted to be free from defects for one year If this product fails during the first 12 months due to faulty materials or workmanship it will be replaced free of charge at the discretion of the manufacturer NOTE This one yeare warranty does not cover dead batteries and blown fuses For warranty and service coverage please return this product to your dealer for processing and evaluation OR return it directly to Electronic Specialties Inc 139 Elizabeth Ln Genoa City WI 53128 262 279 1400 WWW ESITEST COM Defective units being returned to your dealer or to the factory should include proof of purchase date Any testers that do not function due to misuse or abuse will be subject to out of warranty service charges
4. dication Measurements Rate Input Impedance Display AC Current AC Voltage bandwidth Operating Temperature Storage Temperature Relative Humidity Altitude Over voltage Battery Auto OFF Dimensions Weight Safety Operation Test current of 0 3mA typical Open circuit voltage 1 5V DC typical Threshold lt 100Q Test current lt 1mA BAT is displayed OL is displayed 2 per second nominal 7 8MQ VDC and VAC 4000 counts LCD 50 60Hz AAC 50 60Hz VAC 14 to 122 F 10 to 50 C 14 to 140 F 30 to 60 C 90 0 C to 30 C 75 30 C to 40 C 45 40 C to 50 C Operating 3000m Storage 10 000m Category III 600V One 9V Battery approx 35 minutes 229x80x49mm 303g For indoor use and in accordance with Overvoltage Category Il Pollution Degree 2 Category II includes local level appliance portable equipment etc with transient overvoltages less than Overvoltage Cat III NOTICES Read and understand all warning and precaution statements listed in the safety section of this operation manual prior to using this meter Set the function select switch to the OFF position when the meter is not in use Function Range amp Resolution Accuracy of reading 40 00 AAC 2 8 10 digits DC Current 400 0 AAC 2 8 5 digits 1000 AAC 3 0 5 digits 40 00 AAC 3 0 10 digits AC Current 400 0 AAC 3 0 5 digits 1000 AA
5. ilizes about 30 seconds 5 Read the temperature in the display The digital reading will indicate the proper decimal point and value WARNING To avoid electric shock be sure the thermocouple has been removed before changing to another measurement function Data Hold and Backlight To freeze the LCD meter reading press the data hold button The data hold button is located on the left side of the meter top button While data hold is active the HOLD display icon appears on the LCD Press the data hold button again to return to normal operation Note The HOLD feature will activate when the Backlight is turned on Press the HOLD key again to exit Hold The backlight function illuminates the display and is used when the ambient light to too low to permit viewing of the displayed readings Press the HOLD button for one second to turn the backlight on and press the button a second time to turn the backlight off Manual Ranging The meter turns on in the autoranging mode Press the Range button to go to manual ranging Each press of the range button will step to the next range as indicated by the units and decimal point location Press and hold the Range button for two seconds to return to autoranging Manual ranging does not function in the AC Current Diode and Continuity check functions Battery Replacement 1 Remove the one rear Phillips head screw 2 Open the battery compartment 3 Replace the dead battery with one 9V b
6. open device will indicate OL in both polarities Red Black Black Red Probe Probe Probe Probe Capacitance Measurements WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries and unplug the line cords 1 Set the rotary function switch to the cap position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack 3 Touch the test leads to the capacitor to be tested 4 Read the capacitance value in the display Frequency or duty cycle measurements 1 Set the function switch to the V position 2 Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack 3 Select Hz or duty with the Hz button 4 Touch the test probe tips to the circuit under test 5 Read the frequency on the display Temperature Measurements WARNING To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement 1 Set the function switch to TEMP 2 Insert the Temperature Probe into the negative COM and the V jacks making sure to observe the correct polarity 3 Select C or F with the MODE button 4 Touch the Temperature Probe head to the surface area you wish to measure Keep the probe touching the part under test until the reading stab
7. p meter LCD will display the reading DC AC Voltage Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal ak wD Set the function switch to the V position Select AC or DC with the MODE button Connect the test leads in parallel to the circuit under test Read the voltage measurement on the LCD display Resistance and Continuity Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive terminal 2 Set the function switch to the Pt Q position 3 Use the multifunction MODE button to select resistance 4 Touch the test probe tips across the circuit or component under test It is best to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading 5 For Resistance tests read the resistance on the LCD display 6 For Continuity tests if the resistance is lt 100Q a tone will sound Diode Measurements 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack 2 Turn the rotary switch to the Pt position 3 Press the MODE button until appears in the display 4 Touch the test probes to the diode under test Forward voltage will indicate 0 4V to 0 7V Reverse voltage will indicate OL Shorted devices will indicate near OmV and an
8. ter is to be stored for long periods Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests e Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live e f the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Frequency Duty Cycle Test Input Limits Function Maximum Input AAC 1000A V DC V AC 600V DC AC Resistance Diode Continuity Capacitance 250V DC AC Temperature C F 60V DC 24V AC Meter Description Current clamp Clamp trigger Data Hold and Backlight button Mode select button Hz button LCD display COM input jack Rotary Function swith ZERO button 10 Range select button 11 V Q CI F jack 12 Battery compartment on rear 0 ONO Ol BOs 1 AC DC AC alternating current and DC direct currrent 2 D Minus sign 3 8 8 8 8 4000 count 0 to 3999 measurement reading 4 AUTO AutoRange mode 5 gt Diode test mode 6 Audible Continuity 7 HOLD Data Hold mode 9 C F u m V A K M 2 Units of measure list Specifications Diode Test Continuity Check Low Battery Indication Overrange In