Home

Antari Lighting and Effects LCU-1 User's Manual

image

Contents

1. II GIDE User Manual for LCU 1 Liquid Control Unit Congratulations on the purchase of your new ANTARI LCU 1 Liquid Control Unit _FOG MACHINE Antari LCU 1 Liquid Control Unit Congratulations on the purchase of your new ANTARI LCU 1 Liquid Control Unit Introduction Thank you for choosing an ANTARI Liquid Control Unit You now own a rugged and powerful state of the art machine Prior to use we suggest that you carefully read all of the instructions By following the suggestions found in this user manual you can look forward to the reliable and satisfactory performance of your ANTARI Liquid Control Unit for years to come Please follow these operation safety and maintenance instructions to ensure a long and safe life for your Control Unit Cautions Risk of electric shock Disconnect the appliance from the electric supply before removing the cover Note there are no user serviceable parts inside Danger of electric shock Keep this device dry For inside use only Not designed for outside use For the 110V models use 3 prong grounded electrical outlet only Prior to use take care to determine that the unit is installed at the rated voltage Keep Liquid Control Unit upright Turn off or unplug when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the housing immediately unplug the unit and contact a service technician or your ANTARI dealer before using i
2. e recommended cleaning regimen is as follows 1 While unit is unplugged and clean out debris with vinegar and a pipe cleaner making sure that the tube is free of clogs 2 Add cleaning solution to tank Run unit in a open area until tank is empty 3 Cleaning is now complete Refill with fog liquid Clean with a dry cloth only Store dry Read and save these instructions CO8LCU1
3. quipment necessary to operate the system has arrived intact Refer to the Features section for information on what items are included with your model If any equipment is missing contact your ANTARI dealer immediately Before beginning initial setup of your ANTARI Liquid Control Unit make sure that there is no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance Setup See connection diagram Z 1200 S 1001 1 1 CE FTA 664 FTA 64 P FT 6 Liquid N cont ai ner Remove all packing materials from shipping box Check that all foam and plastic padding is removed Place Liquid Control Unit on a flat surface Put a Tank beside Liquid Control Unit and connect a 6mm PU tube between Tank amp Liquid Input Adapter Connect 6mm PU tube from Liquid Output Adapter then extend this tube to four Z 1200 fog machine S 100lls ICEs Each terminal use FT 6 FTA 64 and FTA 664 divide liquid flow direction Firmly attach the remote control cable to the proper input on the rear of the machine If you are connecting the machine to a DMX controller or in a daisy chain of DMX controlled devices ensure the various cables are connected to the proper socket on the back of the fog machine Operation Plug power cord into a grounded electrical outlet If necessary tu
4. rn power switch on rear of unit to ON position To extrude liquid press the appropriate button on the remote for the desired length of time For further information on operating your ANTARI Liquid Control Unit refer to the Antari onboard Remote Control Operation For details regarding DMX refer to the Antari onboard DMX fog machine settings section If you experience low output pump noise or no output at all unplug immediately Check Tank fluid level the external fuse remote connection and power from the wall If all of the above appears to be O K plug the unit in again If fluid does not come out after holding the remote button down for 30 seconds check the tube attached to the tank to make sure there is fluid going through the tube If you are unable to determine the cause of the problem do not simply continue pushing the remote button as this may damage the unit Return the machine to your ANTARI dealer Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges Maintenance Do not allow the fog liquid to become contaminated Always replace the caps on the fog liquid container and the fog machine liquid tank immediately after filling After every 40 hours of continuous operation it is recommended to run a cleaning solution composed of 80 distilled water 20 white vinegar through the system to prevent the accumulation of particulate matter in the tube Th
5. t again No user serviceable parts inside Refer to your ANTARI dealer or other qualified service personnel Danger of burns For adult use only Liquid Control Unit must be installed out of the reach of children Never leave the unit running unattended Locate the fog machine in a well ventilated area In order to guarantee adequate ventilation allow a free air space of at least 20 cm around the sides and top of the unit Keep flammable materials at least 50 cm away from the Unit Always allow your ANTARI Liquid Control Unit to cool down before attempting to clean or service it Danger of explosion Never add flammable liquids of any kind oil gas perfume to the Liquid Control Unit Pay attention to all warning labels and instructions printed on the exterior of your ANTARI Liquid Control Unit Maximum pressure of the pump inside the machine is 7 BAR Maximum fog output is 20 000 cubic feet minute Visibility during operation is reduced Use only the high quality water based fog liquid that your dealer recommends Other fog liquids may cause clogging or spitting Operating this unit without liquid will cause damage to the pump If your ANTARI Liquid Control Unit fails to work properly discontinue use immediately pack the unit securely preferably in the original packing material and return it to your ANTARI dealer for service Unpacking amp Inspection Open the shipping carton and verify that all e

Download Pdf Manuals

image

Related Search

Related Contents

Eurofase 15813-035 Installation Guide  JUMBO 6000 L/D Combiline JUMBO 6600 L/D Combiline  取扱説明書  Fujitsu PRIMERGY RX350 S8  OneTouch® Vita™ User Guide Denmark  La route de la Baie-James - Gouvernement régional d`Eeyou Istchee  R4 Series User Manual  ABUS TVAC40500 wire connector  Toshiba Tecra R840-S8432  

Copyright © All rights reserved.
Failed to retrieve file