Home

Angenieux DATACRYPTOR 1270A450-005 User's Manual

image

Contents

1. Log Type Code Trap Severity Message Information No Key 2064 875 Minor Peer Failed to Add SA Auto Notify is Disabled Key 2065 876 Minor SA is Offline Peer Unit has different SA Mode Key 2066 877 Minor SA is Offline SA is missing from Peer Unit Key 2067 878 Minor Stalled Key Exchange Installation Abandoned Key 2068 879 Minor Stalled Key Exchange Installation Abandoned Key 2069 880 Minor Stalled Key Exchange Installation Abandoned Key 2070 888 Informational Removed peer certificate by ACL Key 2071 889 Informational Peer s KEKs deleted Page 122 THALES Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Audit Errors Log Type Code Trap Severity Message Information No Audit 701 Informational Session started User has successfully logged into unit Audit 2 702 Informational Session stopped User has logged off Audit 3 703 Informational Session stopped lost Session has been contact with host terminated user unable to communicate with unit Audit 4 704 Informational Viewed logs User is viewing the logs Audit 5 705 Informational General configuration User has altered either updated unit Time Date or interface settings Audit 6 706 Informational Security configuration User has altered either updated KEK lifetime DEK Lifetime Change DEK with KEK option
2. rere rer terr teerennsnnnsnnnsnnsannuus 100 Appendix H SNMP MIB Support erre rrr rern ren tnnrnnnsnnn sans annsnntnn suns innui 102 Appendix I Log and SNMP Trap Numbers eere reennenntnnrnnnnans 105 Standard Traps oot tete utr edi det av ee o dieto edens 105 Log Trap Errors Hardware sessi 106 Log Trap Errors Software ssesssssssssseeseeeeeeeeee rennen 108 Ke Addrol kb EL 110 Xen de eecteiee a see say cece eae eae a eee ee eee 123 Appendix J Glossary Of Terims ssesssssssssssssssssesssesstessnessnessonesseessntessnessanessueesanessonesnses 132 Page 4 Datacryptor Ethernet User Manual Preface 1 Preface Trademark Acknowledgements Datacryptor is a trademark of Thales e Security Microsoft Windows XP and Windows 2003 are registered trademarks of Microsoft Corporation All other logos and product names are trademarks or registered trademarks of their respective companies 2006 2008 Thales e Security All rights reserved Copyright in this document is the property of Thales e Security It is not to be reproduced modified adapted published translated in any material form including storage in any medium by electronic means whether or not transiently or incidentally in whole or in part nor disclosed to any third party without the prior written permission of Thales e Security neither shall it be used otherwise than for th
3. esessessssssssssssseeeeee nnn n nnne nnn nnns nnns nnns nnns 59 The IP Management Tab ueeeeeesesesessseeeneneeen nnn n nnne nnns nns 61 Configuring SNMP 62 IP ROUTE CONTIG ie a a eiat 70 The Security Tab cen Deni pe tes Sache ct 71 The RIP Tabire eaea oes ceci eei e oto rette 73 The Ethernet Comm Tab for 1 and 10 Gigabit Datacryptors 75 The Ethernet Comm Tab for 100 Mb Datacryptor eeeeee 77 The Ethernet Encryption Tab ccccccccsssssssseeeeeeeceeeeesssseeeeeeeeeeenaaeaes 79 Th Expert Tb 5 code eerte i tes ceetecp edet oec oe ce he ek et EE renais 80 The Ethernet Tunneling Tab eeeeeeeeeeeeeeeeeeeenennnnnnnnnnnnnns 81 The Environment Tab cccccccsssssssseceeceeecceeeesseeeeeeeeeeseuasseeeeeeeeeeeseaaaes 85 Appendix A Device Maintenance eccsssssssssssssesssessssssesseessnesstsssessessnesntssnesanesnteenesonesonesnses 86 Appendix B Loading Datacryptor Unit Software 88 Appendix C Product Specifications e rr rerrrsennansnanamstnuass 95 Appendix D Environmental amp Regulatory erre eeenneenee 96 Appendix E SFP and XFP Interfaces ssssssssssssssssesssssssesssesnnessnsesnnessunesanessusesnnessnnesnses 98 Appendix F Preventing Electrostatic Discharge s 99 Appendix G Troubleshooting
4. Log Type Code Trap Severity Message Information No Audit 46 733 Major Keylock moved to Transport Audit 47 734 Major Keylock moved from Transport Audit 48 735 Major Keylock moved to Erase Audit 49 736 Major Keylock moved from Erase Audit 50 744 Informational Tunnel SA Added Audit 5 745 Informational Transport SA Added Audit 59 746 Informational Set Private Network Audit 60 747 Informational Set Private Address Audit 61 748 Informational Set Public Address Audit 62 749 Informational Default mode is Discard Audit 63 750 Informational Default mode is Passthrough Audit 64 751 Informational Trunk SA Added Trunk Mode not supported by Datacryptor AP Audit 65 752 Informational Tunnel SA Deleted Audit 66 753 Informational Transport SA Deleted Audit 67 754 Informational Trunk SA Deleted Trunk Mode not supported by Datacryptor AP Audit 68 788 Informational Force Standby on boot cleared Audit 69 756 Informational Key Algorithms stored in backup memory Audit 70 757 Informational Key Algorithms recovered from backup Audit 71 758 Critical Random No Generator This may be a statistical diagnostics FAILED fail i e as it is a random number generator it may fail the tests occasionally it is normally expected to recover Audit 72 759 Critical Random No Generator diagnostics RECOVERED Audit 73 760 Major Primary mode failure No Hot standby unit detected response from Private kn
5. Use the following guidelines to prevent ESD damage e Always use an ESD wrist or ankle strap and ensure that it makes skin contact e Connect the equipment end of the strap to an unpainted metal chassis surface e If no wrist strap is available ground yourself by touching the metal chassis 1270A450 005 June 2008 Page 99 Appendix G Troubleshooting Datacryptor Ethernet User Manual Appendix G Troubleshooting This appendix is provided to aid you in determining basic problems with your Thales Datacryptor Ethernet unit If you cannot resolve the problem using this troubleshooting guide please contact Thales customer support Possible Problems and Solutions The troubleshooting information in this section is grouped into the following categories logging in configuration and traffic flow Within each category you will find a list of symptoms and possible solutions Logging In Symptom Explanation and Possible Solutions Boot Process Fails Contact Thales support for advice Administrator password is forgotten or lost Contact Thales for service Not able to connect to the CLI Re boot the unit Log out of the Element Manager application Check the Baud rate settings are set to 115200 8 N 1 Not able to log in to the Front Panel Viewer Verify the password Configuration Symptom Explanation and Possible Solutions Datacryptor does not recognize its new IP addres
6. Do you wish to change the name of the unit C No l do not wish to change the unit s name Yes want to change the name of the unit Test Unit Each Datacryptor Ethernet unit within a User Group must have a different name You can either leave the unit name as delivered since units are manufactured with unique names the same as the serial number or change it now according to your security procedures The edit box displays the unit s current unit name 1 To keep the displayed unit name click Next 2 Alternatively to change the unit s name click on the Yes radio button and edit the name Then click Next to continue Page 50 Datacryptor Ethernet User Manual Element Manager Reference Step 4 Generating a Certificate Commission Datacryptor Wizard Generate a Certificate DHP File emoNKeyM aterial Universal dhp y Browse Validity Effective Date 02 01 1970 Expiration Date 31 12 2034 1 Enter the path to the DHP File Diffie Hellman Parameters or use the Browse button to select it 2 Specify the dates between which the Certificate is valid in the Effective Date start and Expiration Date finish fields The Start Time is effectively 00 00 and the End Time is 23 59 unless the issuing CA is different on the days selected The default end date is the last day of the issuing CA 3 Click Next to continue and a dialog will list the options you have chosen 1270A450 005 June 2
7. must have a route defined for the address in order for the Traps to be delivered to the SNMP Manager To add a new SNMP trap manager 1 Select the Traps tab 2 Select the appropriate SNMP version tab 3 Click the Add button 1270A450 005 June 2008 Page 65 Element Manager Reference Datacryptor Ethernet User Manual Add SNMPv1 Trap Manager 1 1 Trap Address 12 34 Community public Trap Filters Information jw Warning w Minor WV Major Critical Deed Trap Address Type the IP address of the SNMP trap manager Community This field is unused because the unit only issues SNMP Version 3 traps You can set this field to any value without affecting behavior of trap issuance Trap Filter Tick the categories of event to send to this trap manager Note It may take up to 20 seconds to acknowledge the selected action Page 66 THALES Datacryptor Ethernet User Manual Element Manager Reference Adding SNMPv3 Trap Managers When using SNMPv3 you are able to specify whether the reports will use authentication alone or authentication and privacy combined or no security at all Add SNMPv3 Trap Manager 1 1 1 1 Trap Address E 43 122 5 67 Security Type No Auth No Priv User Joe_Toms Trap Filters iv Warning Minor v Major w Critical cet oe Add Trap Manager dialog for SNMPv3 Security Type Select the type of security that will be used for the reports
8. Select the file and click OK Image Loader files may also contain signed ACE images 1270A450 005 June 2008 Page 89 Appendix B Loading Datacryptor Unit Software Open Datacryptor Image File O 1 11 1810 Datacryptor Ethernet User Manual My Recent Documents My Network Places SEE STI Files of type File name dc2k ilf ILF file 4 The Image Loader may also perform other housekeeping tasks such as generation of correct Ethernet address and IP addresses used by later software if these are missing If housekeeping tasks are performed you will be notified in the Status Messages 5 The baud rate at which the upload will take place is displayed and the upload of the new application code will begin Page 90 Datacryptor Ethernet User Manual Appendix B Loading Datacryptor Unit Software f Datacryptor Image Upgrade Utility Version 4 4 0 5 ud 1 Communication Settings r Upgrade Settings Serial v Save Log of events C Ethemet E 92 168 200 82 Status Messages Datacryptor Image Upgrade utility Version 4 4 0 5 Session started 08 52 26 AM 19 July 2007 Ready Initializing Communications Current Bootstrap version 03 03 0005 Reading Datacryptor configuration file Serial Number 44100001520 Installed Ethernet Addr 00 00 00 00 00 00 Datacryptor configuration written successfully Upload Progress B Help
9. Start Upgrade Operations during Ethernet Code Loading The following operations are only applicable if you are using an Ethernet connection for loading 1 The Image Loader will try to initialize communications with the Datacryptor 1270A450 005 June 2008 Page 91 Appendix B Loading Datacryptor Unit Software Datacryptor Ethernet User Manual f Datacryptor Image Upgrade Utility Version 4 4 0 5 aiii 1 M Communication Settings Uparade Settings Serial COM 1 default desc Ethemet 19216820052 Status Messages Datacryptor Image Upgrade utility Version 4 4 0 5 Session started 09 01 18 AM 19 July 2007 Ready Couldn t connect with unit Invalid hardware for oc192 siq Couldn t update firmware Upload Progress Help Start Upgrade Close 2 Once the hardware has been validated select the Image Loader file 11 file containing the Datacryptor application image e g dc2k 11 Select the file and click OK Page 92 Datacryptor Ethernet User Manual Appendix B Loading Datacryptor Unit Software Open Datacryptor Image File Look in 1 11 1810 EEG My Recent Documents File name de2k ilf Files of type ur file 3 Image Loader will begin uploading the code contained in the Image Loader file f Datacryptor Image Upgrade Utility Version 4 4 0 5 ud x Communication Settings U
10. At the IPCONFIG gt prompt type SET lt port gt lt ip address gt lt subnet mask gt where lt port gt identifies the port to be set and is one of the following NETWORK public network port CONTROL serial control port ETHERNET Ethernet management port lt ipaddr gt is IP address of a subnet to be added or deleted lt netmask value gt is netmask of the subnet Examples Set Control 2 2 2 2 255 255 0 0 Sets the Control serial port IP Address to 2 2 2 2 Set network 3 4 5 6 255 255 0 0 Sets the network port IP Address to 3 4 5 6 255 255 0 0 Note No two IP addresses should be the same IP addresses of 127 x x x are not allowed Net masks of 0 0 0 0 and 255 255 255 255 are not allowed Public and Private port addresses must be valid Class A B or C addresses For this reason subnet masks must comprise of consecutive 1s from the left hand side when represented in binary for example 255 255 1 0 is invalid To make the unit request an Ethernet Management Port IP address from a DHCP BOOTP server on the LAN set its Ethernet Management Port IP address to 255 0 0 0 and net mask to 255 255 255 255 this is an exception to the rule mentioned in the note above To reset the addresses to factory defaults use the DEFAULT command The above section details the steps necessary to connect via the Ethernet management port Dial Up Networking It is also possible to connect and run the Element Manager prog
11. Audit 115 797 Major Decrypt clock speed within range Audit 118 803 Informational RIP Protocol switched off Audit 119 804 Informational RIP protocol changed to RIP 1 Audit 120 805 Informational RIP protocol changed to RIP 2 broadcast Audit 121 806 Informational RIP protocol changed to RIP 2 multi broadcast Audit 122 807 Informational RIP 2 authentication password changed Page 128 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Audit 123 808 Informational RIP 2 authentication enabled Audit 124 809 Informational RIP 2 authentication disabled Audit 127 812 Informational RIP metric changed Audit 128 855 Informational Subduers length set Audit 129 856 Informational IP settings updated Audit 130 857 Informational Level 2 settings updated Audit 131 858 Informational Level 3 settings updated Audit 132 859 Informational Link settings updated Audit 133 860 Informational NUA in outgoing calls enabled Audit 134 861 Informational NUA in outgoing calls disabled Audit 135 862 Informational NUA in incoming calls enabled Audit 136 863 Informational NUA in incoming calls disabled Audit 137 854 Informational Log text overflow Audit 137 864 Informational Log text overflow Lack of logging resourc
12. and 256 bits to encrypt and decrypt data in blocks of 128 bits The Datacryptor uses 256 bit keys 1270A450 005 June 2008 Page 17 Background Information Datacryptor Ethernet User Manual Authenticate Management Data The Datacryptor Ethernet uses the HMAC keyed hash variant of the SHA 1 Secure Hash Algorithm to authenticate management data using SNMP v3 Security Terms Diffie Hellman Diffie Hellman is a method for key exchange that allows two autonomous systems to exchange a secret key over an untrusted network without prior secrets Diffie Hellman groups define the strength supplied to the Diffie Hellman calculation for the later creation of keys by the peers Three of the five available groups are generated from modulo function MODP calculations and the leveraging of very large prime numbers Peer A peer is a Datacryptor that acts as a tunnel endpoint A peer encrypts or decrypts data adding or stripping away headers respectively Other Terms Layer2 The Datacryptor Ethernet is designed to work as a Layer two encryptor The addressing scheme is physical i e the addresses are MAC Media Access Control addresses hard coded into a device at the time of manufacture It is generally a 48 bit address which is usually displayed in hexadecimal format as six two digit parts 01 OB 3B 18 00 CA It should be noted that when the unit is operating in the Tunneling mode the peer unit MAC address must be obtained and entered in the b
13. in days hours minutes or the time at which to perform a daily key exchange see next control e Time of Day Key Exchange check this box to force a regular key exchange at the same time every day as specified by the DEK field e Change KEK with DEK check this box to change the KEK when the DEK changes When this is checked the KEKs are not stored and will not be visible in the Key Management dialog 1270A450 005 June 2008 Page 71 Element Manager Reference Datacryptor Ethernet User Manual Disable Key Exchanges check this box to disable all key exchanges other than those required to make a secure connection This disables the previous 4 controls until you uncheck it Retry every minute with this box checked the Datacryptor Ethernet will try to poll for lost peers every minute this is the default behavior If the retry every minute box is unchecked the Datacryptor Ethernet will gradually increase the time intervals between attempted key exchanges It will try after one minute then after a further 2 minutes and then after a further 4 minutes i e the interval is doubled each time The interval will continue to double up to a maximum interval of 2 hours it will then continue to poll every 2 hours Force Key Exchange click this button to force an immediate key exchange with the peer unit Advanced Setting View SNMP MIB If checked the user will be able to use an external SNMP MIB browser to view information regardin
14. must be running if a serial connection is to be used 1 Start the Element Manager e g by double clicking its icon M Element Manager 2 The Element Manager Main Window will be displayed E gt Element Manager File Edit View Tools Help 9 x BD 3 Add a new Datacryptor Ethernet unit by clicking on the New Unit icon or selecting the New Unit option from the File menu This will launch the Add a New Unit Wizard Page 28 THALES Datacryptor Ethernet User Manual Connecting to Datacryptor Ethernet Units Add a New Unit Wizard This wizard will help you connect to a unit Unit Type C Crypto Manager Datacryptor Please enter the IP address of the unit you wish to connect to F 4 Select the unit type as Datacryptor and enter the IP address of the Datacryptor Ethernet unit Press Enter or select Next to continue Add a New Unit Wizard Is the unit connected to a network or to the serial part of the PC Serial Port Help lt Back Nee Cancel 1270A450 005 June 2008 Page 29 Connecting to Datacryptor Ethernet Units Datacryptor Ethernet User Manual 5 Select the connection type for the Datacryptor Ethernet unit press Enter or click on Next to continue Add a New Unit Wizard Please enter a descriptive name of this connection Datacryptor Ethernet 1 Help lt Back Frin Cancel 6 The application will attempt to connect to the specified IP add
15. unsuccessful key exchange connection may be lost or units may be busy Key 1017 517 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1018 518 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1019 519 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1020 520 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1021 521 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1022 522 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1023 523 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful key exchange connection may be lost or units may be busy Page 116 THALES Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Key 1024 524 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful k
16. AS NZS 3548 1997 with Amendments 1 and 2 CNS 13438 1997 and CAN CSA CISPR 2296 EN61000 3 2 1995 EN61000 3 3 1999 Underwriter Labs Safety Canadian Safety Safety for participating European nations FCC Title 47 Part 15 Subpart B EMC Directive 89 336 EEC and ICES 003 Harmonic Currents EN61000 4 2 1995 EN61000 4 3 1995 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1995 EN61000 4 11 1995 Electrostatic Discharge Radiated Immunity Electrical Fast Transient Burst Lightning Surge Conducted Disturbances Voltage Dips Variations and Short Interruptions FCC Information USA This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Page 96 Datacryptor Ethernet User Manual Appendix D Environmental amp Regulatory Interference Causing Equipment Standard Compliance Notice Canada This Class B digital apparatus meets all requirements of the Canadian interference causing Regulations Cet appareil num rique de la classe B est respecte toutes les exigences du R glement
17. Authorization Number RAN prior to the return of any equipment under the provisions of this warranty Please contact your authorized reseller or the nearest Thales e Security product support center for details General Requirements This equipment should be installed by a qualified Service engineer Incorrect connection will invalidate warranty and may cause a hazard Should any malfunction be suspected in the unit return the apparatus to your supplier for service and or repair to ensure continued compliance The Datacryptor Ethernet unit contains no user serviceable parts The unit should be installed in an environment compatible with the maximum operating temperature of the unit Installation of the unit in a rack should not reduce airflow so as to compromise safe operation of the unit Particular attention should be made to make sure that the side ventilation holes on the Datacryptor Ethernet are not obstructed which could reduce the airflow through the unit Please refer to the Installation chapter in the section titled Airflow for further information on providing appropriate air flow When installed in a rack make sure that the unit is securely installed using all the appropriate mechanical fixings so that it will not cause a hazardous condition Page 8 THALES Datacryptor Ethernet User Manual Preface Security Advisory This unit is being shipped with a Universal Certificate Authority that is to be used for demonstration purpose
18. DHCP configuration updated 1270A450 005 June 2008 Page 127 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Audit 97 784 Informational SNMP configuration updated Audit 98 785 Major Random No Generator Random number DISCONNECTED generator has stopped possible hardware error Audit 99 786 Major Random No Generator Random number RECOVERED generator has started working again Audit 100 852 Critical Standby mode forced Audit 101 853 Minor Standby mode released Audit 102 829 Informational Access control options set Audit 103 830 Informational Disabled access control Audit 104 831 Informational Enabled access control Audit 105 832 Informational Access control password set Audit 106 815 Informational Security configuration updated Audit 107 789 Informational System stopped The system was powered of at the time this message is logged Audit 108 790 Informational IP configuration updated Audit 109 791 Informational Key exchange forced Audit 110 792 Informational Default action set to passthrough Audit 111 793 Informational Default action set to discard Audit 112 794 Major Encrypt clock speed out of range Audit 113 795 Major Decrypt clock speed out of range Audit 114 796 Major Encrypt clock speed within range
19. Datacryptor Ethernet User Manual Element Manager The Element Manager application provides a secure way to configure manage and upgrade the Datacryptor Ethernet The program runs under various versions of Microsoft Windows operating systems Please see the Software Requirements for a more detailed description of the environment required The PC can connect to a Datacryptor Ethernet unit to manage it using the IP protocol over a standard 10 100 Ethernet connection The PC can also connect to a Datacryptor Ethernet unit using PPP protocols via a serial connection Once the PC is connected to the Datacryptor Ethernet unit a Communications session can be established and all the functions provided by the Element Manager are available Page 16 THALES Datacryptor Ethernet User Manual Background Information 4 Background Information Datacryptor Ethernet Unit The Thales Datacryptor Ethernet units are high performance integrated security appliances that provide encryption at high line speeds The 1 Gig and 10 Gig Ethernet units operate at optical line speeds and have the added advantage that they can over limited distances use copper media The device s high speed processing capabilities eliminate bottlenecks while providing data encryption and integrity It is ideal for bandwidth intensive latency sensitive applications that demand security and speed such as site to site VPNs and the transfer of imaging over the network It provi
20. Front Panel Viewer as shown in Step 8 of the previous section Command Line Parameters The Element Manager s Front Panel Viewer can be invoked from the command line with an IP address as a parameter Insert the full path to the exe file e g C Program files Thales e Security Element Manager and use Dc2k exe 192 168 1 15 The parameter is displayed on the title bar at the top of the application s window Page 32 Datacryptor Ethernet User Manual Connecting to Datacryptor Ethernet Units This provides a mechanism for another application e g an SNMP network manager to invoke the Front Panel Viewer for a specified Datacryptor unit If Dc2k exe is invoked without any parameters it will prompt the user to enter the IP address of the unit to connect to To display a short summary of the command line parameters supported use the command Dc2k exe 1270A450 005 June 2008 Page 33 Element Manager Reference Datacryptor Ethernet User Manual 7 Element Manager Reference The Element Manager consists of the following components e The Main Window e The Front Panel Viewer e The Configure dialog e Key Manager e The Login dialog e The Change Password dialog e The Logs window e The Properties dialog Each will now be described in turn Remember that you also have access to online help while using the Element Manager via the F1 Help key and the Help menu Main Window E gt Element Manager File Edit
21. Settings These settings are stored in a file in the SecureData subdirectory To protect these settings an administrator should configure the Front Panel Viewer as required and then restrict access to the SecureData directory and its contents to read only for users 1270A450 005 June 2008 Page 45 Element Manager Reference Datacryptor Ethernet User Manual When the directory is set to read only the Front Panel Viewer will disable the Configure button Key Manager As previously stated when the Datacryptor Ethernet unit is supplied from the Manufacturer Thales e Security provides the CA that is loaded When first commissioned the unit may require testing and the Universal CA provided on the Datacryptor Element Manager CD ROM can be used This CA is very insecure as all owners of Datacryptor units will have a copy which means that they all have the Admin2 usr file that can be used to log into any unit that has the Universal CA loaded It is essential for security to change this Universal CA to a Custom CA as soon as possible If the unit owner has a copy of Certificate Manager a trusted member of staff can create the Custom CA if not an external SA can provide one The process of installing the required elements is done via Commission button on the Key Manager dialog The Key Manager dialog is opened via the Key Manager button on the Front Panel Viewer To commission a unit with the Commission button 1 Click the Key Manager bu
22. THROUGH AUTHORIZED RESELLERS OF THALES OPENING OR INSTALLING ANY OF THE CONTENTS OF THIS CD ROM OR OTHER PROVIDED MEDIA PACKAGE INDICATES YOUR ACCEPTANCE OF THE TERMS AND CONDITIONS OF THIS LICENSE IF YOU DO NOT AGREE WITH THE TERMS AND CONDITIONS PROMPTLY RETURN THE PACKAGE THE MACHINE WHICH CONTAINS A COPY OF THE LICENSED FIRMWARE AND ALL OTHER ENCLOSED ITEMS IF ANY TO THE PLACE WHERE YOU OBTAINED THEM AND YOU WILL RECEIVE A REFUND LICENSE GRANT A In consideration of the license fee paid to THALES or to an authorized THALES reseller THALES hereby grants you and you accept a nonexclusive license to use the Software on a single machine if a single license is purchased or multiple machines if an organizational license is purchased owned leased or otherwise controlled by you and to use the Firmware solely on the Machine sold to you by THALES or its dealers if any but only to operate or engage those features and or applications for which a charge appears on your order and invoice under the terms stated in this Agreement Ifa software or Firmware enabling key or other similar access device the Key is provided you agree to use same solely for accessing the Software on a single PC or Firmware on a single Machine Title and ownership of the Software Firmware Documentation and or Key remain in THALES or its suppliers If an organizational license is purchased then you may use the Software or Firmware on multiple Machines in your orga
23. The differences between the two models are mainly in the speed of operation and the physical size of the casing This manual describes how to install the Thales Datacryptor Ethernet unit and the Element Manager software It also describes how to use the Element Manager software to configure and manage the Thales Datacryptor Ethernet device This document is intended for use by network technicians managers and security administrators who are familiar with setting up and maintaining network equipment Some knowledge of network security issues and encryption technologies is assumed This document assumes that its readers have an understanding of the following e Basic principles of network security issues e Basic principles of encryption technologies and terminology e Basic principles of Ethernet technology e Basic principles of TCP IP networking including IP addressing switching and routing e Personal computer PC operation common PC terminology and use of terminal emulation software The following conventions are used in the body text of this document Bold font Indicates a command to be issued or selected by the user e Courier font Indicates information input or output to from the Control PC e Italic font Indicates the name of dialog parameter object etc 1270A450 005 June 2008 Page 11 About This Document Datacryptor Ethernet User Manual This manual is organized into the following sections Overview provides general
24. View Tools Help d x E Datacryptor Datacryptor Datacryptor London Glasgow Liverpool The main window is displayed when the Element Manager application is launched providing access to menus toolbar and a window containing icons representing each of the Datacryptor units added to the system Each of the components of the main window will now be described in more detail Page 34 THALES Datacryptor Ethernet User Manual Element Manager Reference Main Window Pull down Menus The pull down menus are File Edit View Tools and Help File The following options are available from the File pull down menu Menu Option Add a new Datacryptor unit to the window Delete Unit Delete the selected Datacryptor unit from the window Terminate the application closing all sessions that may be open Edit The following options are available from the Edit pull down menu Menu Option Undo Delete Restore the last Datacryptor unit deleted Edit Unit Edit the selected unit s description IP address or connection method View The following options are available from the View pull down menu Menu Option Toolbar A toggle controlling the display of the Toolbar and its buttons Ticked when enabled Status bar A toggle controlling the display of the Status bar which is used for context sensitive message and help Ticked when enabled Large icons The four different ways that Datacryptor details can be shown in the Small
25. appropriate e Close close the Logs Window and return to the Front Panel Viewer The View menu provides e Audit If this option is ticked the all the Audit entries in the log are shown e Error If this option is ticked then all the Error entries in the log are shown e Trace If this option is ticked then all the Trace entries in the log are shown e Key Update If this is ticked then all the Key Update entries are shown e Newest First Oldest First select the order in which entries are displayed by clicking on it The selected order is indicated e Find search through the displayed logs for specified text e Refresh update the display by reading the logs from the unit again e Stop Reading F6 halts the process of reading entries from the audit log The function key F5 Refresh can also be used for the logs window The Help menu provides access to on line help 1270A450 005 June 2008 Page 55 Element Manager Reference Datacryptor Ethernet User Manual Properties Dialog The Properties dialog is displayed when you select the Properties button in the Front Panel Viewer The image shown on the dialog will reflect the model of Ethernet Datacryptor that you are using r Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP Unit Name m 4 Unknown Description i loaded Unit Time 12 33 13 21 02 2008 Change
26. diagnostic tests to be performed by external test equipment The Audit log will record when the host port Private Loopback or network port Public Loopback has loopback enabled or disabled Note The Datacryptor 100 Mb Ethernet does not support loopback of either the Network or Host interface Select one or both of the loopback options e Network Select the Network option to create a loopback between the unit and its peer for troubleshooting purposes e Host The Host option is used to create a loopback between the unit and its local network Loopback functionally is available while the unit is in all encryption modes and all entries and exits will be entered into the units audit log Page 60 Datacryptor Ethernet User Manual Element Manager Reference Note The loopback mode is regarded as a transient feature intended purely as an aid to troubleshooting Therefore when the unit is rebooted the loopback options are set to Disabled The IP Management Tab The properties on the IP Management tab control the IP addressing of the unit C Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP IP Address Net Mask Control Port 1 1 1 1 255 255 255 255 Network 1 2 3 4 255 255 255 255 Ethernet 16 32 48 64 255 255 255 255 BOOTP DHCP Control Port Baud Rate Data Bits H SNMP Config Parity r Stop Bits i IP Route Con
27. icons main window The currently selected method has a bullet next to it List Details Redraw the window updating all details 1270A450 005 June 2008 Page 35 Element Manager Reference Datacryptor Ethernet User Manual Tools The following options are available from the Tools pull down menu View Audit Log Display an audit log of all changes made using the Element Manager Dial Up Networking Launches the operating system s Dial Up Networking application to manage dial up connection details or make a connection Poll Network Units Poll all Datacryptor units connected via the network Proxy Ping Ping test a specified IP address on a network Allows the Time To Live TTL packet size and Timeout to be selected This does not apply to Datacryptor Ethernet units and is grayed out Options Displays the Datacryptor Options dialog to control operation of the management application Options are Save changes to Disk and Poll all units on startup Help The following options are available from the Help pull down menu Menu Option Help Topics The main entry point into the application s on line Help system The application s version information Toolbar Icons The Toolbar displays a number of graphic buttons that provide direct access to key functions Create New Datacryptor icon File New Datacryptor menu option X Delete Selected Datacryptor icon File Delete Datacryptor menu option e Dial Up Net
28. installed Key 2022 622 Informational Red KEK deleted Key 2023 623 Informational Red Key mode started Key 2024 624 Informational Red Key mode stopped Key 2025 625 Informational CA algorithm loaded Key 2026 626 Informational Key exchange algorithm loaded Key 2027 627 Informational KEK algorithm loaded Key 2028 628 Informational DEK algorithm loaded Key 2029 629 Informational Symmetric algorithm loaded Key 2030 630 Informational CA algorithm load failed Key 2031 631 Informational Key exchange algorithm load failed Key 2032 632 Informational KEK algorithm load failed Key 2033 633 Informational DEK algorithm load failed Key 2034 624 Informational Symmetric algorithm load failed Key 2035 635 Informational All KEKs deleted Key 2036 636 Informational Peer s KEKs deleted Key 2037 637 Informational Single KEK deleted Key 2038 638 Informational Initialised access control password Key 2039 639 Minor Tunnel SA added by Peer Key 2040 640 Minor Transport SA added by peer Key 2041 641 Minor Trunk SA added by Peer Trunk Mode not supported by Datacryptor AP Key 2042 642 Minor SA set to Tunnel by Peer Key 2043 643 Minor SA set to Transport by Peer Page 120 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Key 2044 644 Minor SA set
29. is additional background to help understand what has occurred if it is not clear There are a large number of messages that are identical these have different log and trap numbers to help support staff further identify and investigate the actual cause of the log entry There are a number of log trap message numbers usually failures that have the same text this is because the effect the user experiences can be caused by subtly different internal events occurring Logging these events differently can help Thales e Security diagnose complex support issues Standard Traps Message coldStart Issued when the Datacryptor is powered up for the first time or whenever it is power cycled other than by the application warmStart Issued when the Datacryptor is restarted by its application linkDown Issued when either the host or network interfaces is detected as being down This might be due to Loss of Signal LinkUp 3 Issued when either the host or network interfaces is detected as being up authenticationFailure Issued when an attempt is made to access the Datacryptor SNMP interface using an unknown community name or a community name without the correct access level The log messages are detailed on the following pages in this order Log Trap Errors Hardware Log Trap Errors Software Key Errors Audit Errors 1270A450 005 June 2008 Page 105 Appendix Log and SNMP Trap Numbers Log Trap Errors Hardware Data
30. is operating Answer Test incorrectly Key 1056 556 Major Peer has no CA algorithm PEER Failed CA Known loaded or it is operating Answer Test incorrectly Key 1057 557 Minor Peer reported No common Load valid key material Red KEK between this unit into the units check unit and the peer date and time Key 1058 558 Minor Peer reported DEK exchange unsuccessful Key 1059 559 Minor Peer reported DEK exchange unsuccessful Key 1060 560 Minor Peer reported DEK exchange unsuccessful Key 1061 561 Minor Peer reported DEK exchange unsuccessful Key 1062 562 Minor Peer reported DEK exchange unsuccessful Page 118 THALES Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Key 1063 563 Minor Peer reported DEK exchange unsuccessful Key 1064 564 Minor Peer reported DEK exchange unsuccessful Key 1065 565 Minor Peer reported DEK exchange unsuccessful Key 1066 566 Minor Peer reported failed to create DEK Key 1067 567 Minor Peer reported failed to create KEK Key 1068 568 Minor Peer reported failed to encode private network Key 1069 569 Minor Peer reported failed to decode our private network Key 1074 571 Major Peer reported key exchange with peer denied due to ACL Key 2000 600 Informational Line mode changed Key 2001 601 Informat
31. key and other information such as issuer s name and algorithms used in encryption and decryption Certification Authority CA A certificate authority is a trusted organization that accepts certificate applications authenticates applications issues certificates and maintains status information about certificates Cipher block chaining CBC A method of using a block cipher in which two identical plaintext blocks encrypt to different ciphertexts Ciphertext An unintelligible form of data that can only be read if specific operations are performed on it using a key and decrypting algorithm Ciphertext Stealing CTS CTS mode is a Datacryptor mode of operation that minimizes the latency caused by the encryption of the Ethernet packets passing through the Datacryptor unit Command Line Interface CLI The CLI is the text based user interface to the Datacryptor Diffie Hellman A protocol which allows two users to agree a secret key over an insecure medium without any prior secret keys Digital Signature A digital signature must be difficult to repudiate and must protect the integrity of the information being signed By encrypting a digest of a message with the private key authentication can later be performed by applying the public key to an encrypted digest digital signature and comparing the result to the digest of the message Digital Signature Standard DSS A standard for digita
32. properties configuration e Configure This button displays a dialog which allows you to set properties that control how the Front Panel Viewer manages passwords and session timeout e License Management This button is not used in the Datacryptor Ethernet Page 42 Datacryptor Ethernet User Manual Element Manager Reference e Help The Help button launches the help application displaying the help file for the dialog e Close The Close button closes the Front Panel Viewer Configure Dialog This dialog is displayed when you select the Configure button from the Front Panel Viewer It provides configuration of the rules that the Front Panel Viewer will enforce in support of the security policy Configure Legacy File Minimum Password Length 8 to 28 p reject Enable Enhanced Security upgrade Enhanced Security rc Cancel Legacy File To support the enforcement of security policy the format of the User Key Material file has been extended The adminv3 usr file is in this extended format Any existing files and those generated by the Certificate Manager have not been extended The adminv2 usr file is in this original format The FPV may be configured to reject accept or upgrade User Key Material files that do not contain the extended fields e accept Legacy files will be accepted by the Front Panel Viewer even if enhanced security is turned on The enhanced checks will not be made when a legacy fil
33. reso Ve A 18 Installation es 19 Hardware Installation cccccccscccccessecececesseeeeceueceeeceueceeseaeeeeseageeeeseaaees 19 Rack Mounting Instructions 0 eee 19 Cabling Requirements cessisse 20 To Cable the Datacryptor ccccssssccceeeccceeesseeeeeeeeeeeeneesseeeeeeeeessaseeees 21 Power on the Datacryptor sccccccecccceeeesseeceeececeeeeesseeeeeeeesensaaeees 22 Software IistallatiOn vias cuxos ii oor tina iet pr e tke tre eve en eoo rese rk Duty eco vade 23 Requirerntents a ipe hes asta actin fel as SER DR I ERREUR 23 Installation Procedure scccccccssseceeceseceeeeeseceecaseceeseaeeeeeseeeeeeeseaaees 24 Connecting to Datacryptor Ethernet Units 25 LIC Ce L aun eae E ees Agee ane oacelyiec tanec 25 IP Parameter Configuration via a Serial Connection ceeeeeeeeeees 25 Dial Up Networking cccce cece cece eect ceeeeeea aaa aaeaaaaaaaaaaaaaaaaaaaaaaaaea 27 Adding a Unit to Element Manager ceccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 28 Direct Invocation of Front Panel Viewer eeeeeeeee eene nnns 32 Command Line Parameters cccccccssececceesseeeceeseeeccaaseeeeeeaseeeessageeesseaes 32 Element Manager Reference sasssssmsssssssssssssessnsessunescsnsessansessunessnusessnneesnusessaneessaneeenseesee 34 Main Wind OW m 34 Main Window Pull down MenuS ccccccssecceecessceeec
34. setting Movement or Temp alarm status Erase Button Key requirement Audit 7 707 Informational Serial port configuration User has altered one of updated the control port parameters This could be either Baud Rate Data Bits Parity or Stop Bit values Audit 8 708 Informational IP management User has altered the IP configuration updated address Audit 9 709 Informational Comms configuration updated Audit 10 710 Informational T1 configuration updated Audit 11 711 Informational E1 configuration updated Audit 12 712 Informational Line test configuration updated Audit 13 713 Informational Date time before update Unit time at time of time date change with respect to new time Audit 14 714 Informational Date time after update Unit time at time of time date change with respect to old time Audit 15 715 Informational Reboot unit Unit Soft Rebooted Audit 16 716 Informational Initiate diagnostic test Audit 17 717 Informational Standby mode configured Audit 18 718 Informational Plain mode configured 1270A450 005 June 2008 Page 123 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Audit 19 719 Informational Encrypt mode configured Audit 20 720 Informational Standby mode configured by peer Audit 21 721 Info
35. sur le mat riel du Canada European Notice Products with the CE Marking comply with both the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community 1270A450 005 June 2008 Page 97 Appendix E SFP and XFP Interfaces Datacryptor Ethernet User Manual Appendix E SFP and XFP Interfaces The Datacryptor 1 Gig Ethernet unit is supplied with Small Form Factor Pluggable SFP interfaces see above using single mode fiber or multi mode fiber MM SPF as specified at the time of ordering The 10 Gig Ethernet unit is supplied with 10 Gigabit Small Form Factor Pluggable XFP single mode fiber laser devices see below as specified at the time of ordering The following multi rate devices are supported e Copper RJ45 e 1310nm single mode short range e 1310nm single mode intermediate range e 1310nm single mode long range e 1550nm single mode intermediate range e 1550nm single mode long range e 1550nm single mode long range DWDM Page 98 THALES Datacryptor Ethernet User Manual Appendix F Preventing Electrostatic Discharge Appendix F Preventing Electrostatic Discharge Electrostatic discharge ESD can damage electronic components and equipment ESD occurs when electronic components are improperly handled and can result in complete or intermittent failures Always follow ESD prevention procedures when removing and replacing components
36. to Trunk by Peer Trunk Mode not supported by Datacryptor AP Key 2045 645 Minor SA mismatch use Tunnel Key 2046 646 Minor SA mismatch use Transport Key 2047 647 Minor SA mismatch use Trunk Trunk Mode not supported by Datacryptor AP Key 2048 648 Minor Tunnel SA deleted by Peer Key 2049 649 Minor Transport SA deleted by Peer Key 2050 650 Minor Trunk SA deleted by Peer Trunk Mode not supported by Datacryptor AP Key 2051 651 Minor Peer deleting non existent SA Key 2052 798 Informational IP Transport SA with duplicate peer unit name removed Key 2053 800 Informational IP Tunneling SA with duplicate peer unit name removed Key 2054 799 Informational IP Trunk Protocol SA with Trunk Mode not duplicate peer unit name supported by Datacryptor removed AP Key 2055 801 Informational Peers private network information updated Key 2056 656 Minor NUA added by peer Key 2057 657 Minor NUA deleted by peer Key 2058 658 Minor Peer delete Non existent NUA Key 2059 659 Minor Failed to Delete NUA in Peer Unit Key 2060 871 Minor Failed to add SA to Peer Unit Peer has Auto Notify disabled Key 2061 872 Minor Failed to Delete SA from non Auto Notify Peer unit Key 2062 873 Minor Peer Failed to Delete SA Auto Notify is Disabled Key 2063 874 Minor Peer Failed to Add SA add bit not set 1270A450 005 June 2008 Page 121 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual
37. valid for use in passwords they may cause problems with third party scripting tools Note also that ampersands question marks periods and commas are not allowed Selecting this box will enable password format checks in addition to the basic password requirements Those checks require the password to include e At least two upper case alpha characters A Z e At least two lower case alpha characters a z e At least two numeric characters 0 9 e At least two special characters from this list 1 A _ f 15 lt gt Password Lifetime Enter the required maximum lifetime of a password in days The Front Panel Viewer will require the user when logging into a unit to change the password if it has not been changed within this many days A value of zero indicates that the password will not expire Maximum Login Attempts The Front Panel Viewer can block a user from logging into a unit if incorrect passwords are entered Set this field to the number of wrong attempts that are allowed before the user is blocked Once a user has entered the correct password the count of failed attempts is reset Login Block Time As explained in the previous paragraph the Front Panel Viewer can block a user from logging into a unit if incorrect passwords are entered Set this field to the time in seconds that the user should be blocked for Page 44 THALES Datacryptor Ethernet User Manual Element Manager Reference The user will be blo
38. 0 Major RIP password does not match password in oncoming RIP message Key 126 811 Major Expecting an authorisation entry in RIP message Page 114 THALES Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Key 904 895 Informational Key Material erased Key 1000 500 Warning Peer reported no response This may indicate an from us addressing error Key 1001 501 Warning Peer reported no common DEK algorithm Key 1002 502 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1003 503 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1004 504 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1005 505 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1006 506 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1007 507 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1008 50
39. 008 Page 51 Element Manager Reference Datacryptor Ethernet User Manual Commission Datacryptor Wizard The following operations have been configured 1 Install New CA 2 Set Unit Name 3 Install Certificate Press the Finish button to proceed with the commissioning process 1 Click Finish to begin the commissioning process which will take a few seconds Datacryptor 1 1 1 1 C3 Press Y es to confirm that the Datacryptor has validated PK The LEDs on the front of the unit should be flashing 2 When commissioning has completed confirm that the Datacryptor unit s LEDs are flashing which indicates that the unit has been commissioned successfully Check the unit s LEDs or get someone else to do so if the unit is remote and click Yes if they are flashing The new CA and certificate can be seen in the Certificates tab of the Key Manager 4 Once a unit has been commissioned with the correct CA and Certificate it can be used for the transfer of secure information Page 52 THALES Datacryptor Ethernet User Manual Element Manager Reference Login Dialog This dialog is displayed when you select the Login button from the Front Panel Viewer to login to gain access to the unit management facilities Login to Datacryptor Disk Password Change Password Key Material Ic KeyMaterial adminv2 ust Bier Cancel Enter the password into the login dialog and either click the OK button or press Ente
40. 2008 Change Interface Cables detected ETHERNET Configure Unit Settings Save Load Save changes on exit Auto Refresh Unit Name read from the unit Description read from the unit Change click this button to set the unit s clock calendar The clock is used to track the time that Keys are created and to track certificate expirations The unit operates internally on UTC time and the Element Manager attempts to correct when setting and when displaying for the users time zone Note If you set the unit s clock backwards to a date and time in the past reboot it to avoid filling the log files with error messages about the time setting 1270A450 005 June 2008 Page 57 Element Manager Reference Datacryptor Ethernet User Manual Cable detected the types of cable connected to the unit Save stores the current properties in a named file which can then be loaded using the Load button for example to restore the settings after a unit has been reset to factory defaults Load loads saved properties from a named file You can then examine edit or save them or apply them to the current unit by clicking the Apply button Save changes on exit tick this box to save the current properties to a named file when you exit the program Auto Refresh tick this box to re load the current setting from the unit every n seconds where n is set by the adjacent control Warning This may cause large a
41. 3 Critical Internal software error Software Error 8 153 Critical Internal software error Software Page 108 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Error 9 153 Warning Corrupt Log text entries Software Error 11 153 Warning Inconsistent Log error counts Software Error 12 153 Warning Inconsistent Log name Software entries Error 13 153 Warning Blank name entries in Log Software Error 19 839 Major Algorithm version not User has tried to load Software supported by this application incorrect version of version algorithm Error 20 1849 Major Destination selector table Software full Error 21 1850 Major Source selector table full Software Error 22 1851 Major Security Policy table full Software Error 23 153 Critical SRAM Corruption has been Software detected Error 24 153 Critical SHA 1 Known Answer Test Software failed Error 25 153 Critical SHA 1 RNG Known Answer Software Test failed Error 27 153 Warning SNMP Agent Error Software 1270A450 005 June 2008 Page 109 Appendix Log and SNMP Trap Numbers Key Errors Datacryptor Ethernet User Manual Log Type Code Trap No Severity Message Information Key 200 Warning No response from peer No response from peer whe
42. 8 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1009 509 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1010 510 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1011 511 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy 1270A450 005 June 2008 Page 115 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Key 1012 512 Warning Peer reported DEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1013 513 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1014 514 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1015 515 Warning Peer reported KEK exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 1016 516 Warning Peer reported KEK exchange Unexpected time out in
43. Appendices Appendix A Device Maintenance Periodically perform maintenance on your Datacryptor e Keep components free of dust and other particulate matter e Check fans for reduced airflow caused by dust build up and clean as necessary e Examine cables and fiber for damage and ensure that airflow requirements have been met e Consult the Environment tab on the Front Panel Viewer s Properties dialog for readings of the fan speeds and unit temperature Make a note of these readings under normal operating conditions these readings can be used for comparison in the event of a Fan Heat monitor alarm Otherwise no special maintenance is required Physical Inspection The Datacryptor is housed in a tamper evident chassis Periodically check the chassis for evidence of tampering Items to look for include stripped screws and damaged seals 1 Gig Ethernet unit rear view Model Part amp Serial Number Tamper Labels Power Warning Label C li Label ud cnc Tamper Label Position over screw head Tamper Labels 1 Gig and 10 Gig Ethernet units plan view Figure A 1 Location of Tamper Proof and Identification Labels on the units The frequency of a physical inspection depends on the value of the intellectual property being protected and the security of the environment in which the Datacryptor is located For example Page 86 THALES Datacryptor Ethernet User Manual Appendix A Device Maintenance a locked equipment clo
44. COMO and the following serial port parameters Serial Port Parameter Value Baud Speed 115 200 Parity None Data Bits 8 Stop Bits 1 Flow Control None Switch on the Datacryptor unit 4 As the unit boots the message CONFIG STARTUP Y N will be shown and all the units LEDs will be lit 5 Press Y the unit will respond by displaying a short banner and the prompt IPCONFIG gt 6 At the command prompt type Help for a list of commands available HELP Display help for a command HELPKEYS List of keyboard usage in this command interface DEFAULT Return all IP address and net mask settings to defaults DISPLAY Display current IP address and net mask settings IPFORWARD Enable or disable IP forwarding ROUTE Add delete or display IP routing data SET Set an IP address and net mask settings SETTIME Display or set the unit time Un commissioned Datacryptor Ethernet unit SHOWLOG Basic display of log contents VERSIONS Display version numbers of application and bootstrap EXIT Exit the process and reboot the unit if a parameter has been changed or just exit if no changes have been made Note Before setting the Management port s parameters you may want to read the IP Management tab section for some background knowledge on their values Page 26 Datacryptor Ethernet User Manual Connecting to Datacryptor Ethernet Units 7
45. ET SMIv2 compliant MIB file containing Thales e Security enterprise specific trap values for the SONET units Please see the supplied MIB file for specific details Page 102 THALES Datacryptor Ethernet User Manual MIB Name DC2K MIB RFC1 213 DC2K MIB RFC1 317 DC2K MIB RFC1 907 DC2K MIB RFC201 1 Appendix H SNMP MIB Support Description RFC 1213 defines the Management Information Base MIB II for use with network management protocols in TCP IP based internets The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes The Datacryptor does not support TCP communications and EGP operations and as such the device will not support any SNMP operations involving the TCP or EGP groups of RFC 1213 Please see the supplied MIB file for specific details RFC 1317 defines a portion of the Management Information Base MIB II Specifically it defines objects for the management of RS 232 like devices The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes Please see the supplied MIB file for specific details RFC 1907 defines a portion of the Management Information Base MIB II Specifically it defines the new SNMPv2 framework and the associated MIB objects The Datacryptor supports the majority of read write attributes in this MIB as rea
46. Front Panel Viewer will cause a refresh of all displayed settings from the unit User Key Material Adminv2 usr User key material containing public and secret keys of user protected by a default password of PASSWORD Adminv3 usr Alternative user key material containing public and secret keys of user protected by a default password of 11aaBB PASS The Front Panel LEDs The Front Panel LEDs indicate the state of the unit Indicator Light State Indication Power green On Unit is powered on Off No power Network green On Normal operation Fast Flash Link Down Slow Flash Not used Off Loss of Signal Loss of Synchronization Error red On Errors have occurred Fast Flash New errors in log Off No errors 10M 100 Mb Off 100 Mbps operation Ethernet unit only On 10 Mbps operation Loopback yellow Off Normal operation no loopback enabled 1 Gig and 10 Gig Slow flash Host loopback enabled Ethernet units only Fast Flash Network loopback enabled On Host and Network loopback enabled Alarm red On Unit is alarmed Hardware fault Fast flash Unit is not commissioned Off No Alarm Encrypt green On Unit is in Encrypt mode Slow flash Standby Off Unit is not in Encrypt mode Plain red Fast Flash Unit is in Plain mode Off Passthrough mode not selected Host green On Normal operation 1270A450 005 June 2008 Page 41 Element
47. Gig Ethernet units have two SFP or XFP sockets which accept a range of transceiver modules for the encrypting and decrypting of network traffic e Device management access through a 10 100 Ethernet port or an RS 232 craft port Security features e Designed to FIPS 140 2 Level 3 Hardware based encryption processing e Very low latency Maximum Data Transfer Rate e 200 Mbps full duplex 100 Mb Ethernet unit 2 Gbps full duplex 1 Gig Ethernet unit or 20 Gbps full duplex 10 Gig Ethernet unit Network Interfaces e 10 100BaseT User selectable between 10 Mbps and 100 Mbps e 1 Gig Ethernet 1000 Mbps full duplex e 10 Gig Ethernet 10 000 Mbps full duplex e Auto negotiation does not apply to the 10 Gig Ethernet Overview Key management e Diffie Hellman key exchange groups 1 2 and 5 Encryption e Advanced Encryption Standard AES FIPS 197 256 bit keys Management integrity e HMAC SHA 1 96 FIPS PUB 180 1 RFC 2104 2404 e HMAC MD5 96 RFC 2104 2403 1321 Device management e Element Manager e Secure download of software updates e X 509v1 and X509 v3 digital certificate support Power e 100 Mb Ethernet Unit Single fixed AC universal or DC 48 V power supply 15W 51 BTU hr e 1 Gig Ethernet and 10 Gig Ethernet Redundant hot swappable AC universal or DC 48 V power supplies 1 Gig 120 W 410 BTU hr 10 Gig 140 480 BTU hr 1270A450 005 June 2008 Page 15 Overview
48. Interface Cables detected ETHERNET Configure Unit Settings Save Load Save changes on exit Auto Refresh You use the dialog to examine and change the properties of the selected unit These properties are organized into a number of separate tabs To display a different tab click on its name or use Ctrl Tab to display the next tab or Ctrl Shift Tab to display the previous tab If you make changes on a tab they will be written to the unit when you click the Apply button or click the OK button to apply the changes and close the dialog You can also store or retrieve the properties by using the controls in the Unit Settings box on the General tab this provides an easy way to backup and restore settings among other applications Note Press F5 to refresh the displayed properties or tick auto refresh on the General tab to refresh automatically Page 56 THALES Datacryptor Ethernet User Manual Element Manager Reference Each of the tabs will now be described in turn The General Tab The properties on the General tab control the general behavior of the unit The image shown on the General tab will reflect the model of Ethernet Datacryptor that you are using f Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP Unit Name w d Unknown Description Not loaded Unit Time 12 33 13 21 02
49. Manager Reference Datacryptor Ethernet User Manual Fast Flash Link Down Slow Flash Not used Off Loss of Signal Loss of Synchronization The Front Panel Viewer buttons C Front Panel 1 1 1 1 Unit Name Management Version Application Version Bootstrap Version Serial Number CA Datacryptor Ethernet THALES Logout Configure Management w e View Logs 410000153R 4 4 00 10 4 00 1 3 02 5 410000153R Not loaded o ud Ew o o Automatically Poll LEDs Key Manager Properties Ready License Management Help Close The buttons in the Front Panel Viewer are the same for all models of Ethernet Datacryptor they provide access to the management facilities as follows Login This button is only enabled if you have not logged in yet Click on it to display the Login dialog supply your password and you will gain access to the full set of management facilities Once you have logged in the button changes to Logout e Management Click on this button to display the Element Manager main window e View Logs This button displays the Logs Window for you to produce examine and manage error and other logs from the selected unit e Key Manager Displays the Key Manager dialog to manage the units CAs and Certificates e Properties This button displays the Properties dialog box for the unit which allows you to examine and change the unit s
50. Mode Up Laser Mode On Pause Auto Negotiation Frame CheckSum Status e x tot Low Ethernet Comm Tab for the 1 Gigabit Datacryptor The properties are as follows Mode Selects one of two options for the transmission mode Bulk Unit encrypts everything including Ethernet header Tunneling Unit encrypts every thing below Ethernet header When a mode change is made then the following dialog will be shown advising that the unit must be rebooted 1270A450 005 June 2008 Page 75 Element Manager Reference Datacryptor Ethernet User Manual Datacryptor 1 1 1 1 You will need to re boot the Datacryptor for the changes to take effect The unit can be rebooted using the option available on the Diagnostic tab Interface Mode Allows the Host and network interfaces to be switched Up Down Laser Mode Allows the Host and network Lasers to be individually switched On Off Pause The Pause option is a special Ethernet function that provides flow control between Ethernet devices If the switch on the public network is told to enable Pause then a rule has to be configured on the encryption unit to let the Pause frames pass through unencrypted to the switch on the local side A typical rule is Plain public 01 80 c2 00 00 01 This Multicast address corresponds to address reserved in IEEE 802 3 for the Pause functionality Note The Pause tick box is not displayed for the 10Gig Ethernet un
51. Public known unit attempted to be come IP address primary and failed as no response was received from known address on network public port Audit 87 774 Minor Primary attempt succeeded Hot standby Private side Response from Private configuration appears to known IP address work Audit 88 775 Minor Primary attempt succeed Hot standby Public side Response from Public known configuration appears to IP address work Audit 89 776 Informational Operating in Secondary Hot standby unit has mode become Secondary Audit 90 777 Informational Operating in Primary mode Hot standby unit has become Primary Audit 91 778 Major Primary unprotected No Hot standby Primary unit contact from Secondary unit has detected that the on host side secondary unit does not appear to be responding on the host private port Audit 92 779 Major Primary unprotected No Hot standby Primary unit contact from Secondary unit has detected that the on network side secondary unit does not appear to be responding on the network public port Audit 93 780 Major Primary protected Contact Hot standby Primary unit from Secondary unit on host has detected secondary side unit on host private port Audit 94 781 Major Primary protected Contact Hot standby Primary unit from Secondary unit on has detected secondary network side unit on network public port Audit 95 782 Informational Hot Standby configuration updated Audit 96 783 Informational
52. SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM JURISDICTION TO JURISDICTION THALES does not warrant that the functions contained in the Software or Firmware will meet your requirements or that their operation will be uninterrupted or error free LIMITATIONS OF REMEDIES THALES its authorized resellers and or its suppliers entire liability and your exclusive remedies under this Agreement are as follows 1 THALES shall use commercially reasonable efforts to correct any defect in the Software or Firmware which is reported by you during the Warranty Period in writing to THALES provided such defect can be recreated by THALES in an unmodified version of the Software or Firmware However if THALES is unable to correct such defect within a reasonable amount of time you may terminate this Agreement by returning the Software Machine including Firmware Documentation and Key to the place where you obtained them either for replacement or if so elected by THALES a refund of the amount paid by you for the subject item 2 THALES shall replace any media not meeting THALES Limited Warranty and which is returned to THALES with a copy of your receipt invoice or other proof of purchase or if THALES is unable to deliver replacement media which is free from defects in materials or workmanship you may terminate this Agreement by returning the Software Firmware Documentation and Key to the place where you obtaine
53. THALES Datacryptor Ethernet User Manual 1270A450 005 June 2008 Datacryptor Ethernet User Manual Preface Page 2 THALES Datacryptor Ethernet User Manual Contents AAA E ALEE EE EE AE 5 Trademark Acknowledgements ccccccccecceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 5 Revision Status ote dos toa eese een 5 License Agreement and General Information cccccssseesceeeeeeeeeeteeeeees 6 Security ACViSOMy zi iie eset Wied ee e did ed ent elec eive adie ceed 9 Contact Information eiii voc had vete eee aee bye anna a e WV cR va uada 10 About This Document esha 11 This manual is organized into the following sections 12 udi 13 Product Images eie cipe ate praece pe ues de poderes 13 Product Features ERR SEP E 15 Element Manager uusssessssssseseseses esee nnne nnne Auei nn nnn nnns nnns aa a nnns nnns 16 Background Information sssssssssesseessesssseesseesstessosessnessnnessnessnnesseesnnessunesnnessonesoneesass 17 Datacryptor Ethernet Unit c cccsccceeeccceeessssseeeeeeceseueessseeeeeneeeeesaaageeess 17 Gigabit Ethernet Technology Overview esesesssseseeeeeeeeenee 17 Ethernet Layer 2 Services scccceccccceeseseeeeeeeeeceeeaeseeeeeeeeesseasseeeeenes 17 Securty erts tee iier ener hene doen aS RSPR TAPAA EEA DR Pu activa stdedeseande 18 Other TERNS 222 n cu or tet eoe ee iode
54. ace is based upon RFCs 1213 2011 2013 2096 2665 2863 and 3417 All MIB files provided with this product are SMIv2 compliant Because the Datacryptor Ethernet is a security device the SNMPv3 implementation in the Datacryptor Ethernet is more restrictive than specified in the standard RFCs listed above In general we have disabled most of the SET operations in order to protect critical security parameters configuration items and device attributes Where the device SNMPv3 implementation has deviated from a RFC specification we have provided an updated RFC MIB files reflecting those changes Supported MIBs are listed in the table below MIB Name Description DC2K MIB R4 SMIv2 compliant MIB file containing Thales e Security enterprise specific values This MIB is used as the parent for all other MIB files except the RFC MIB files Please see the supplied MIB file for specific details DC2K MIB ETHERNET SMIv2 compliant MIB file containing Thales e Security enterprise specific values for the Ethernet units Please see the supplied MIB file for specific details DC2K TRAP ETHERNET SMIv2 compliant MIB file containing Thales e Security enterprise specific trap values for the Ethernet units Please see the supplied MIB file for specific details DC2K MIB SONET SMIv2 compliant MIB file containing Thales e Security enterprise specific values for the SONET units Please see the supplied MIB file for specific details DC2K TRAP SON
55. ack unstable Make sure that the rack is secured and use the proper mounting hardware to secure the Datacryptor to the rack Circuit Loading Consider the connection of the Datacryptor to the supply circuit and the effect that overloading of circuits might have on over current protection and supply wiring Consult the voltage and amperage ratings on the UL label affixed to the unit s rear panel when addressing this concern As the 1 Gig and 10 Gig Ethernet units are fitted with two hot swappable power supply units consideration could be given to these types of Datacryptors using a different supply phase for each of the power supply units Disconnection Power disconnection is achieved by removal of the plugs from the mains outlet sockets Ensure that the socket outlets are close to the unit and can be easily identified and accessed Grounding Maintain reliable grounding of a rack mounted Datacryptor Pay particular attention to supply connections other than direct connections to the branch circuit such as the use of power Strips Maintenance Allow at least 19 inches 48 3 cm of clearance at the front of the rack for maintenance Use a cable management system to help keep cables organized out of the way and free from kinks or bends that degrade cable performance Connect the Cables Before beginning make sure the necessary cables are available See the Cabling Requirements section below for more information Cabling Requireme
56. al CAUTION Rebooting the device interrupts the data traffic on the Host and Network ports Erase click this button to erase the unit s Key material Basic unit Configuration will not be lost i e the unit can still be managed remotely once the unit has re booted The following confirmation dialog will be shown Click on Yes to continue The unit will delete the key material and reboot this will close any management sessions including dial up networking connections Datacryptor 1 1 1 1 p This operation will also reboot the unit This may terminate the connection to the unit requiring the Management Application to be re started If you are connected to the unit by dial up Networking this too will have to be re started Are you sure you want to continue Loopback The loopback facility is a diagnostics test capability that allows either or both of the ports to loop back any signals that are applied For example if the Host port is placed in loopback then the local signals sent to the Datacryptor for encryption and onward transmission are in fact simply returned back to the Host port Likewise if the Network port is placed in loopback mode any signals received from a remote unit are looped back out to that remote unit An indication of the loopback status of the unit can be obtained from the Loopback LED on the Front panel See The Front Panel LEDs for the details These loopback options allow line
57. cked from further attempts for this time Once the block time has expired the user will again be allowed to attempt to log in Inactivity Time The Front Panel Viewer can automatically log off a user if it has seen no mouse or keyboard activity for a time Set this field to the maximum inactivity time in seconds Password History Length The Front Panel Viewer keeps a record of the last nine passwords for each User Key Material File and will when changing a password reject the new password if it has been used before Set this field to indicate the number of previous passwords that will be included in the check Setting this to one indicates that the new password will only be checked against the existing password and not against any of the previous passwords Setting this to ten indicates that the new password will be checked against the existing password and all nine previous passwords Defaults When the Front Panel Viewer is first installed these fields will default to the values shown here Configure Legacy File Minimum Password Length 8 to 28 18 reject Enable Enhanced Security upgrade Enhanced Security rc Cancel These settings permit the Front Panel Viewer to operate identically to the previous version when using legacy files If the enhanced security enforcement features are not required then legacy User Key Material files including the universal adminv2 usr file may be used without upgrade Securing the
58. cryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Error 120 Critical Random no generator fault Hardware Error 2 120 Critical Real time clock faulty Hardware Error 3 120 Critical RAM faulty Hardware Error 4 120 Critical Encrypt Clock Limit Line clock is too fast for Hardware Exceeded the unit Error 5 120 Critical Decrypt Clock Limit Line clock is too fast for Hardware Exceeded the unit Error 6 120 Critical Encrypt Clock Stopped Hardware Error 7 120 Critical Decrypt Clock Stopped Hardware Error 8 120 Critical Battery may need replacing Battery may be more than Hardware 10 years old or exhibiting symptoms of low voltage Error 9 120 Critical Random Number Generator Hardware diagnostics Failed Error 10 120 Critical Continuous Random Number Hardware Generator test failed Error 11 120 Critical Real Time Clock not set set Hardware or check battery Error 12 120 Critical Hardware Monitor reports This can be due to fan Hardware alarm heat or power failure Note that power failure is reported separately Error 13 120 Critical Power Monitor reports alarm Hardware Page 106 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Error 14 122 Major Alarm condit
59. cryptors The three variations are shown below Page 38 THALES Datacryptor Ethernet User Manual Front Panel 1 1 1 1 Unit Name Management Version Application Version Bootstrap Version Serial Number CA Datacryptor 10 100 Ethernet Element Manager Reference 410000153R 4 4 02 1 4 00 1 3 02 5 410000153R Not loaded x 2 rar m z 5 Configure jw Automatically Poll LEDs View Logs License Management Help Close 100 Mb Ethernet Front Panel Viewer C gt Front Panel 1 1 1 1 Datacryptor Ethernet THALES Logout Management Configure Unit Name Management Version Application Version Bootstrap Version Serial Number CA Network 410000153R 4 4 02 1 4 00 1 3 02 5 410000153R Not loaded Loopback Encrypt Automatically Poll LEDs View Logs License Management Help Close 1 Gig Ethernet Front Panel Viewer 1270A450 005 June 2008 Page 39 Element Manager Reference Front Panel 1 1 1 1 Unit Name Management Version Application Version Bootstrap Version Datacryptor Serial Number 10 Gig Ethemet CA THALES quw Datacryptor Ethernet User Manual 410000153R 4 4 02 1 4 00 1 3 02 5 410000153R Not loaded x o Ew LE o o E Automatically Poll LEDs Logout Management View Logs Ready Configure License Management Help Close 10 Gig Ethernet Front Panel Viewe
60. d Avoid exposure and do not stare into the open apertures Apertures should be covered when not in use Power on the Datacryptor The Datacryptor software is factory installed on the appliance The bootable image is stored on compact flash Applying power to the Datacryptor initializes the system which includes e Initializing the components e Performing hardware diagnostics e Loading the software e Diagnostic Boot sequence To power on the Datacryptor 1 The 1 Gig and 10 Gig Ethernet Datacryptor appliances are supplied with two separate hot swappable power supply units The 100 Mb Ethernet units have a single fixed power supply unit The power supply units for all models of Datacryptor can be either AC or DC 48 V 2 The AC power supplies are auto sensing 100 to 240 Volts 50 to 60 Hz Before applying power to the Datacryptor verify that the voltage shown on the UL label affixed to the unit s back panel is appropriate for your site your site do not apply power to the appliance Contact Customer CAUTION If the voltage of the Datacryptor is inappropriate for A Support immediately Page 22 THALES Datacryptor Ethernet User Manual Installation 4 On the Datacryptor s rear panel plug the power cords into the power receptacles Attach the opposite ends to a power source The power LED illuminates when the unit is powered up The Diagnostic Boot sequence allows the LEDs to be checked and the
61. d only in order to preserve the security of sensitive attributes The Datacryptor does not support the sysOR table entries of this RFC Please see the supplied MIB file for specific details RFC 2011 defines a portion of the Management Information Base MIB II Specifically it updates various MIB II objects for use within a SNMPv2 framework The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes Please see the supplied MIB file for specific details 1270A450 005 June 2008 Page 103 Appendix H SNMP MIB Support MIB Name DC2K MIB RFC2863 DC2K MIB RFC341 3 DC2K MIB RFC3418 DC2K MIB RFC3584 Datacryptor Ethernet User Manual Description RFC 2863 defines a portion of the Management Information Base MIB II Specifically it defines objects for the management of network interfaces The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes Please see the supplied MIB file for specific details RFC 3413 defines a portion of the Management Information Base MIB II Specifically it defines five types of Simple Network Management Protocol SNMP applications which make use of an SNMP engine as described in STD 62 RFC 3411 SNMP target host tables are neither creatable nor modifiable through the SNMP interface Modification of the
62. d them for a refund of the amount paid by you for the subject item IN NO EVENT WILL THALES ITS AUTHORIZED RESELLERS OR ITS SUPPLIERS BE LIABLE FOR INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR TYPE INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS OR REVENUE LOSS OF USE OF THE PRODUCT S OR ANY ASSOCIATED PRODUCT S OR COST OF SUBSTITUTED FACILITIES PRODUCTS OR SERVICES WHICH ARISE OUT OF THALES PERFORMANCE OR FAILURE TO PERFORM ANY OBLIGATION CONTAINED WITHIN THIS AGREEMENT OR WITH USE OR INABILITY TO USE SOFTWARE AND OR FIRMWARE WHETHER THE CLAIM FOR DAMAGES IS BASED IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE EXCEPT FOR CLAIMS FOR PERSONAL INJURY OR FOR DAMAGE TO REAL OR TANGIBLE PROPERTY TO THE EXTENT CAUSED BY THALES FAULT OR NEGLIGENCE THALES MAXIMUM LIABILITY FOR ANY CLAIM FOR DAMAGES RELATING TO THALES PERFORMANCE OR NON PERFORMANCE UNDER THIS AGREEMENT SHALL BE LIMITED TO THE LESSER OF a YOUR ACTUAL DAMAGES OR b THE COST OF THE PRODUCT GIVING RISE TO THE LIABILITY SOME JURISDICTIONS DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU PURCHASES BY OR FOR THE FEDERAL GOVERNMENT The government hereby agrees that this software qualifies as commercial computer software as that term is used in the acquisition regulation applicable to a purchase order or contract This software may n
63. d then click the Delete button Datacryptor 1 1 1 1 2 Click Yes to confirm deletion or No to cancel deletion Note It may take up to 20 seconds to acknowledge the selected action 1270A450 005 June 2008 Page 69 Element Manager Reference Datacryptor Ethernet User Manual IP Route Config Selecting this button on the Properties IP Management tab will display the IP routes dialog detailing the IP routes that have been defined for this unit and providing facilities to maintain the IP routes list IP Routes 1 1 1 1 IP Routes Des P Mask 1 lNetHp v IP Forwarding Default TTL 8 n T Add Route 1 1 1 1 Destination Address Destination Mask Next Hop cne 7 7 Page 70 THALES Datacryptor Ethernet User Manual Element Manager Reference The Security Tab The properties on the Security tab control crucial aspects of the security of the Datacryptor unit C Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP Key Lifetimes Days HH MM KEK 28 00 00 DEK ot 00 00 Time of Day Key Exchange Change KEK with DEK Disable Key Exchanges Retry every minute View SNMP MIB Advanced Settings Force Key Exchange They are as follows e KEK the longest time that the unit will use a KEK for in days hours minutes e DEK the longest time that the unit will use a DEK for
64. de 5 If the status messages that are generated by the Image Loader utility during the session are not to be saved clear the check box marked Save Log of Events 6 Ensure that the Datacryptor is connected to the selected COM port and that the power is on If the Ethernet radio button is selected use a command window to check that the IP address that you have entered responds to Ping requests 7 Click the Start Upgrade button Note The Image Loader utility will operate differently depending on whether you are using a serial or an Ethernet connection Please use one of the next two sections as appropriate to your type of connection Operations during Serial Code Loading If you are using Ethernet loading please refer to the next section 1 The Image Loader will try to initialize communications with the Datacryptor This will take a short time if the Datacryptor has no application loaded the administrator may be prompted to remove the power and re power up the Datacryptor It is best to power down the unit by removing the mains power cable from the Power Supply Unit 2 The message Current Bootstrap version xx xx xxxx Will be displayed in the status window when the Image Loader has successfully started talking to the bootstrap program in the Datacryptor 3 After loading and re initializing the bootstrap a prompt will be given to select the Image Loader file i1 file containing the Datacryptor application image e g dc2k ilf
65. des secure transport over private or public networks s Network B l IT Aust E wey x a I Public Network Network 4 Connection i di n M E Ens a had atacryptor Dat t pu pes i Ethernet Ethernet ee a 4 i i Figure 4 1 An Example of a Site to Site Ethernet Layer 2 connection A site to site VPN application is shown above The Thales Datacryptor Ethernet is deployed on either side of the connection securing the data transmitted across the untrusted public network Data is sent from a web server through to the host network It is then encrypted by the Datacryptor Ethernet for secure transfer over the public network where a second Datacryptor Ethernet decrypts the data at its destination Gigabit Ethernet Technology Overview The Gigabit Ethernet technology used by the 1 Gig and 10 Gig Ethernet units is the latest specification in the IEEE 802 3 Ethernet standard series This standard allows the transmission of data at one or ten Gigabit per second transmission speeds 1 Gbps or 10 Gbps However the speed is usually designated as 1 000 Mbps or 10 000 Mbps as appropriate to comply with the standard method of showing Ethernet network speeds Ethernet Layer 2 Services Ethernet Layer 2 security services include Encryption The Advanced Encryption Standard AES algorithm is a symmetric block cipher capable of using cryptographic keys of 128 192
66. e The Datacryptor 100 Mb Ethernet may be set to 100 Mbps or 10 Mbps full duplex The Host and Network interfaces on encryption units at both ends of the link need to run at the same speed Pause The Pause option is a special Ethernet function that provides flow control between Ethernet devices If the switch on the public network is told to enable Pause then a rule has to be configured on the encryption unit to let the Pause frames pass through unencrypted to the switch on the local side A typical rule is Plain public 01 80 c2 00 00 01 This Multicast address corresponds to address reserved in IEEE 802 3 for the Pause functionality Speed configured Must be set to 10 Meg or 100 Meg as appropriate to the speed of the link Enabling auto negotiation only permits the Datacryptor to tell requesting units what speed it is set to it does not support the auto negotiation of speed Frame Checksum If the FCS box is checked then the checksum is stripped off the incoming frame and added again for outgoing frames When the FCS box is not checked the FCS is treated like normal data will be and encrypted and decrypted like data on the public interface The FPV imposes the following defaults when switching modes When switching from Bulk to Tunneling the Network FCS is checked When switching from Tunneling to Bulk the Network FCS is unchecked It is advised that the user accepts these default settings Status Shows the current status of the Ho
67. e will mean that some log entries will not have associated text Audit 138 836 Informational Passthrough policy added Audit 139 833 Informational Discard policy added Audit 140 837 Informational Passthrough policy deleted Audit 141 834 Informational Discard policy deleted Audit 142 838 Informational Passthrough policy updated Audit 143 835 Informational Discard policy updated Audit 144 813 Informational LMI monitor active Audit 145 814 Informational LMI monitor inactive Audit 146 738 Informational DHCP gateway interface set Audit 148 848 Informational Auto notify add SA denied max SAs reached Audit 150 865 Informational Auto Notify enabled Audit 151 866 Informational Auto Notify disabled Audit 152 867 Informational ToS byte passthrough in tunnel mode enabled 1270A450 005 June 2008 Page 129 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Audit 153 868 Informational ToS byte passthrough in tunnel mode disabled Audit 154 869 Informational SNMP MIB VIEW enabled Audit 155 870 Informational SNMP MIB VIEW disabled Audit 156 881 Informational RIP broadcast of Ethernet management network information enabled Audit 157 882 Informational RIP broadcast of Ethernet management network informat
68. e bootstrap of the unit If a unit is being upgraded to application software greater then 1 07 04 then the user is advised to upgrade the bootstrap software to the latest version as this is required for the algorithm retention feature WARNING Do not power the Datacryptor unit down during a bootstrap upgrade this may cause the unit to enter an unrecoverable state For this A reason it is recommended that the Datacryptor is connected to an UPS Uninterruptible Power Supply during this process 1 Connect the Datacryptor to the COM port of the PC that has access to the Image Loader utility imgload exe and power it on 2 Start the imgload exe application AS Datacryptor Image Upgrade Utility Version 4 4 0 5 T m Communication Settings Upgrade Settings Serial COM 1 defaut w Save Log of events Ethernet 132 158 200 82 Status Messages Datacryptor Image Upgrade utility Version 4 4 0 5 Session started 08 16 25 AM 19 July 2007 Upload Progress Help Start Upgrade Close Page 88 THALES Datacryptor Ethernet User Manual Appendix B Loading Datacryptor Unit Software 3 Select the COM port that the Datacryptor is connected to using the pull down menu This is COMI by default 4 f the Datacryptor application is already running you may choose the Ethernet radio button Enter the IP address in the field next to the Ethernet radio button Ethernet is faster than Serial for loading co
69. e is used e reject Legacy files will be rejected by the Front Panel Viewer even if enhanced security is turned off The user will be warned that the file will not be accepted e upgrade Legacy files will be automatically upgraded to the extended format when a user attempts to use one The user will be required to provide the correct password before the file will be upgraded 1270A450 005 June 2008 Page 43 Element Manager Reference Datacryptor Ethernet User Manual Extended files including those that have been automatically upgraded should not be used in previous versions of the Front Panel Viewer as that could make them unusable in this current version Minimum Password Length The Front Panel Viewer will require that any new password entered is at least this length It will also require existing passwords that are shorter than this to be changed before allowing the user to login to gain access to the unit management facilities Enable Enhanced Security Select this box to enable the enhanced security policy enforcing features If this check box is cleared the Front Panel Viewer will not enforce any of the rules Note however that the Front Panel Viewer will always keep a record of previous passwords if the user file is in the extended format Password Format Check The basic requirements for passwords are that they must be between 8 to 28 case sensitive alphanumeric characters Although certain special characters see below are
70. e purpose for which it is supplied Thales e Security reserves the right to modify or revise all or part of this document without notice and shall not be responsible for any loss cost or damage including consequential damage caused by reliance on these materials Revision Status 1270A450 002 Release 1 1 August 2006 1270A450 003 10 Gig Ethernet unit added and Updates November 2007 for product release 4 00 1270A450 004 100 Mb Ethernet unit added March 2008 1270A450 005 Unsupported features in the 10Gig June 2008 Ethernet unit Auto negotiation Disabling CTS mode Fragmentation 1270A450 005 June 2008 Page 5 Preface Datacryptor Ethernet User Manual License Agreement and General Information THALES e SECURITY LTD THALES COMPUTER PROGRAM LICENSE AGREEMENT YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT the AGREEMENT FOR PURPOSES OF THIS AGREEMENT SOFTWARE IS DEFINED TO INCLUDE COMPUTER PROGRAMS INTENDED TO BE RUN ON A WORK STATION PC OR SIMILAR MACHINE AND INCLUDES THE CD ROM OR OTHER MEDIA ON WHICH THE SOFTWARE IS CONTAINED FIRMWARE IS DEFINED TO INCLUDE COMPUTER PROGRAMS WHICH ARE INTENDED TO BE RUN SOLELY ON OR WITHIN A HARDWARE MACHINE MACHINE PROVIDED BY THALES INCLUDING WITHOUT LIMITATION FPGA BITSTREAMS THE SOFTWARE AND FIRMWARE AND THE ACCOMPANYING USER DOCUMENTATION THE DOCUMENTATION ARE LICENSED NOT SOLD TO YOU BY THALES DIRECTLY OR
71. e set the addresses select OK to add the new rule to the list The apply button will then become active The Edit and Delete functions requires the user to select a rule prior to clicking the appropriate button However if the table contains only one rule and the user presses either the edit or delete button that rule is automatically selected for the operation CAUTION Care must be exercised when creating filter rules in order that the intended traffic and only the intended traffic is allowed VLAN Settings Enter the required VLAN ID a number between 1 and 4094 If this is set to zero then the MAC addresses are used for in band communications Tunneling Settings An optional fragmentation can be enabled with the Fragmentation Size field in tunnel mode Encapsulated frames that become larger than the public networks allow can be fragmented The fragmentation works like this e Outgoing frames including the tunnel header smaller or equal to Fragmentation Size will be sent to the WAN without modification e Outgoing frames including the tunnel header larger than Fragmentation Size will be fragmented and sent to the WAN in two parts e Incoming frames on the local interface which are already larger than Fragmentation Size will be truncated to Fragmentation Size and therefore discarded on the remote side Note The Tunneling Settings section which includes the Fragmentation Size item is not displayed for the 10Gig Eth
72. e unit has two addresses assigned for use between the units at either end of an Ethernet Layer 2 link The Unit MAC Address is displayed The peer MAC address must be obtained and entered in the box provided 1270A450 005 June 2008 Page 81 Element Manager Reference Datacryptor Ethernet User Manual This is entered by selecting the Change button the following dialog is shown C Edit MAC Address SEE Enter hex values e g O0 3F 20 4C 7B 81 BE o ier ifo soe ife Dk Cancel Enter the required address in the boxes shown Movement between the boxes can be achieved by using the mouse or the tab and shift tab key combinations The units MAC address must be inserted in the peer unit address box at the other end of the link Filter Rules Clicking the Display Filter Rules button will display the following dialog f Filter Rules Host To Network Destination MAC Address Source MAC Address ems Plain BO B1 B2 B3 B4 B5 AGAT AZ AZ A4A5 Block BO B2 B3 B5 A1A2 A3 A4 New Rule Edit Rule Delete Rule Network To Host Destination MAC Address Source MAC Address eem Block 04 08 0C 0D 0E 0F AD BO CO DO EO FO Plain DA 0C O0D DE BO CO D0 FO New Rule Edit Rule Delete Rule OK Cancel Page 82 THALES Datacryptor Ethernet User Manual Element Manager Reference This gives the option of setting a maximum of four rules on both the Host to Network and Netw
73. easeceeeeaseeeeesaeseeeeseaeees 35 File ciii oet e RR stn saddens dence EEE EE S 35 Editio edite A niri imi 35 m A ETN 35 Else EE 36 Help ctt ete Re eoe werde e toot ede dee eto canes 36 Toolbar ICONS ses 2 itn E cue aT 36 Datacryptor ICONS 4 e acie rotten ec dee ERE Po Eee ete doe aeneus 36 Front Panel Viewer nlsi AULGnI ABRIR 38 Us r Key Material ie ete oet ente aAa testet ta eoe aided 41 The Front Panel LEDS 2 imi MEDII eves ceed 41 The Front Panel Viewer buttons ccccccssssseeeeeeeeeceeeeesseeeeeeeeeeeeeaseees 42 Preface 1270A450 005 June 2008 Page 3 Preface Datacryptor Ethernet User Manual Configure Dialog 3 n tetro a apre cadet Eee esee p Vasa aE aa aE 43 Key Manageria 46 To commission a unit with the Commission button ss 46 Step 1 Installing a new Certificate Authority CA ee 48 Step 2 Installing the authenticating CA seeeee 49 Step 3 Setting the unit name sssssseeeeeeHHMH 50 Step 4 Generating a Certificate cccccccceeseeenceceeeeeeeeeeeeeneeeeeeeeeees 5 Login Dialog dicite ie ete oe tr EE RE iens 53 Change Password Dialog essssssssssssessseeseeeeer eren 53 togs loser 54 Properties Dialog creer eee a te Eod Roo ERR ne Red aaa 56 The General Tab iet nte ae a e 57 The Diagnostics Tab
74. eceives the data for encryption Encrypted data is then passed through the network port for secure transmission over the public network The Datacryptor Ethernet is designed to operate as a Layer 2 Data Link encryptor The advantage of this is it makes the unit fully transparent to higher protocols The units are housed in a tamper evident chassis with interlock switches that will cause the key material to be erased if the lid is removed Product Images Figure 3 2 Datacryptor 100 Mb Ethernet Rear Panel 1270A450 005 June 2008 Page 13 Overview Datacryptor Ethernet User Manual Datacryptor Gig Ethernet d LEK Oe Figure 3 3 Thales Datacryptor 1 Gig Ethernet Front Panel Control PSU 1 PSU 2 10 100 Mbps Console Ethernet management management port DB9 F port RJ45 Figure 3 4 Datacryptor 1 Gig Ethernet Rear Panel e THALES Datacryptor 10 Gig Ethernet e Ethernet PSU 1 PSU 2 Console 10 100 Mbps Ethernet management management port DB9 F port RJ45 Figure 3 6 Datacryptor 10 Gig Ethernet Rear Panel Note See The Front Panel LEDs in the Element Manager Reference section for full information on the LED indicators Page 14 THALES Datacryptor Ethernet User Manual Product Features Installation e Mount in any standard 19 rack or on a tabletop Interfaces e The 100 Mb Ethernet has two RJ45 sockets for connecting to the Host and Network circuits e The 1 Gig Ethernet and 10
75. ection method and click OK or press Enter Note The type of unit cannot be changed if you want to change the unit type it will have to be deleted and re added There is also a pop up menu for manipulating Datacryptor icons displayed by right clicking on the icon The options are e Open opens a session with that unit like double clicking on it e Edit edit the unit s descriptive name or IP address like the Edit Edit Unit menu option e Delete deletes the icon from the system like the File Delete Unit menu option 1270A450 005 June 2008 Page 37 Element Manager Reference Datacryptor Ethernet User Manual Front Panel Viewer A splash screen is displayed when you attempt to connect to a Datacryptor Ethernet unit This process should normally complete within a few seconds but might take up to one minute You can abort the connection attempt from the splash screen by pressing its Cancel button Note that the text on the splash screen may change from Identifying unit to Fetching unit information during the connection process ph ATMWIW CIC curity com Datacryptor Net Work Securit ty Syst The splash screen closes and the Front Panel Viewer is displayed when you successfully connect to a Datacryptor Ethernet unit to display its status and provide access to the management facilities There are some differences between the Front Panel Viewer for the 100 Mb Ethernet the 1 Gigabit and the 10 Gigabit Ethernet Data
76. eface LIMITED WARRANTY The following limited warranty applies only to the Software and or Firmware licensed hereunder The hardware Machine is warranted pursuant to a separate Warranty set forth in the Machine documentation The Machine documentation is contained on the CD ROM if any During the first 90 days after receipt of the Software and or Firmware by you as evidenced by a copy of your receipt invoice or other proof of purchase the Warranty Period THALES warrants for your benefit alone that the Software and Firmware when properly installed will perform substantially in conformance with the Documentation provided by THALES at the time you obtained the Software and or Firmware from THALES or its authorized resellers and that the media on which the Software and or Firmware is furnished will be free from defects in materials and workmanship under normal use EXCEPT AS SPECIFICALLY PROVIDED ABOVE THE WARRANTIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU WHEREVER SUCH EXCLUSION IS NOT PERMITTED BY LAW ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY PERIOD THIS WARRANTY GIVES YOU
77. ernet unit The 10Gig Ethernet unit does not support Fragmentation Size setting and will never fragment Page 84 THALES Datacryptor Ethernet User Manual Element Manager Reference The permissible range for Fragmentation Size is e Gigabit Ethernet 0 no fragmentation 256 lt Fragmentation Size lt 16300 e 10 100 Mb Ethernet 0 no fragmentation 256 x Fragmentation Size x 2000 The Environment Tab The Environment tab shows the fan speeds along with the unit temperature and power unit condition These readings may be used to check that the Datacryptor environment is satisfactory for normal operation It is recommended that you make a note of these readings during normal operation These readings may be useful for comparison purposes in the event of problems such as overheating If the unit temperature becomes excessive the Alarm LED will be on and an entry will be made in the Error log please refer to Fan Heat Monitor Alarm for more information f Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethemet Comm Ethemet Encryption Environment Expert Fan Speeds Fan 1 2710 RPMs Fan 2 2710 RPMs Fan 3 2685 RPMs Fan 4 2685 RPMs Unit Temperature Temperature 27C 80F Unit Power Power Ok Refresh Note The Datacryptor 100 Mb Ethernet shows only a single fan 1270A450 005 June 2008 Page 85 Appendix A Device Maintenance Datacryptor Ethernet User Manual
78. es esecurity com e mail support thalesesec com Asia Pacific Tel 4852 2815 8633 Fax 852 2815 8141 e mail aisa support thales esecurity com Page 10 Datacryptor Ethernet User Manual About This Document 2 About This Document Viewing this document in Adobe Acrobat PDF Viewer It is recommended that this PDF document is viewed at 100 size with text smoothing adjusted to suit your monitor The viewing size is easily adjusted by the use of the Zoom toolbar you may set 100 size or simply click the Actual Size icon Window Help H gt A J t 100 He Le LJ Actual size icon Viewing at 100 will provide the best appearance of the images in this document To change the appearance of the text select Edit gt Preferences gt Page Display Change the Smooth Text option and click OK Use this option to compare the appearance of the text with and without text smoothing and then select the setting that provides the most comfortable reading experience Introduction to this Manual There are three models in the Datacryptor Ethernet range 100 Mb Ethernet 1 Gig Ethernet and 10 Gig Ethernet Predominantly the information in this manual applies equally to all models and as such the device is referred to simply as the Datacryptor Ethernet Where there are differences the unit being described is referred to either as the 100 Mb Ethernet 1 Gig Ethernet or 10 Gig Ethernet as appropriate
79. ey exchange connection may be lost or units may be busy Key 1025 525 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful key exchange connection may be lost or units may be busy Key 1026 526 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful key exchange connection may be lost or units may be busy Key 1027 527 Minor Peer reported we have no own unit certificates installed Key 1028 528 Major Peer reported Diffie Hellman parameters do not match Key 1029 529 Minor Peer reported it has no own unit certificate installed Key 1030 530 Major Peer reported no common certificates Key 1031 531 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful protocol connection may be lost or units may be busy Key 1032 532 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful protocol connection may be lost or units may be busy Key 1033 533 Warning Peer reported Certificate Unexpected time out in exchange unsuccessful protocol connection may be lost or units may be busy Key 1034 534 Warning Peer reported Certificate View units peer logs for exchange unsuccessful more information Key 1039 539 Warning Peer reported commissioning Unexpected time out in unsuccessful protocol connection may be lost or units may be busy Key 1040 540 Warning Peer reported commissioning Unexpected time out in unsuccessful protocol con
80. fig They are as follows e Control Port the IP address and net mask of the unit s Control Port this value is only used if the PPP does not negotiate another value e Network the IP address and net mask of the unit s Network Port e Ethernet the IP address and net mask of the unit s Ethernet management Port e Control Port these fields show the settings for dial up networking e SNMP Config click this button to configure the SNMP trapping for this unit e IP Route Config click this button to configure the IP Routing table for this unit 1270A450 005 June 2008 Page 61 Element Manager Reference Datacryptor Ethernet User Manual Configuring SNMP Datacryptor units record all significant management and error events in their logs for later examination but can also be configured to report them immediately to a central location by using the SNMP protocol to help centralize and simplify management Events are reported as SNMP Traps V1 v2c or v3 as selected on the Traps tab see below to a central device typically a PC called an SNMP Network Manager This SNMP Network Manager must be compliant with the SNMP agent version support selection on the Agent Configuration tab see below A list of the log and SNMP trap numbers with descriptions is provided as an appendix to this guide To configure SNMP click the SNMP Config button on the unit s P Management tab to display the SNMP Config dialog This dialog has two tab
81. formance and provide event notifications Transform A transform defines the transformation applied to the data to secure it This includes the encryption algorithm security protocols the key sizes and how they are derived and the transformation process X 509 The ITU T X 509 recommendation defines the formats for X 509 certificates Page 134
82. from the drop down list If the security is set to none No Auth No Priv then the user name will be highlighted in red on the SNMPv3 tab as illustrated by the following image 1270A450 005 June 2008 Page 67 Element Manager Reference SNMP Config 1 1 1 1 Agent Configuration Traps SNMP Trap Version Support Enable SNMPv1 Traps Enable SNMPv2 Traps Enable SNMP 3 Traps SNMPv1 Traps 1 SNMPv2 Traps 1 SNMPv3 Traps 3 IP Address 99 10 11 120 12 13 14 15 test_user2 4uth Only 120 130 140 150 test_user3 Auth and Priv Disabled Disabled Engine ID Page 68 Datacryptor Ethernet User Manual Info Waring Minor Major Critical ANTE o Auth No Priv Disabled Enabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Add Edit Delete Datacryptor Ethernet User Manual Element Manager Reference To edit an SNMP trap manager 1 Select the entry to edit by clicking on it and then click the Edit button Edit SNMPv1 Trap Manager 1 1 Trap Address 1 2 3 4 Community private Trap Filters Information V Warning Minor WV Major jw Critical 2 Edit the entries in the Edit Trap Manager dialog as required and then click OK Note It may take up to 20 seconds to acknowledge the selected action To delete an SNMP trap manager 1 Select the entry to delete by clicking on it an
83. ful key exchange connection may be lost or units may be busy Key 39 235 Warning Could not delete CA Unexpected time out in key exchange connection may be lost or units may be busy Key 40 236 Warning Commissioning unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 41 237 Warning Commissioning unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 42 238 Warning Commissioning unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 44 239 Informational Management session already Unit busy in progress Key 45 240 Warning Key exchange already in Key exchange process is progress busy the unit must try again later Key 46 241 Warning Key exchange already in Key exchange process is progress busy the unit must try again later Key 47 242 Minor Unknown missing error View units logs for more information Key 49 243 Major Failed to set peer s mode Key 50 244 Major Failed to set peer s mode Key 5 245 Major DEK installation failed A key used to encrypt decrypt manager unit communications keys failed when loading 1270A450 005 June 2008 Page 113 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Key 52 246 Major Failed to set line mode Conditions are not met to en
84. g network configuration etc Page 72 Datacryptor Ethernet User Manual Element Manager Reference The RIP Tab The RIP tab sets up the properties of the Routing Information Protocol RIP and configures the way Rip messages are sent to other routers The Datacryptor Ethernet supports versions RIP 1 and RIP 2 f Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP RIP Compatibility f Off Metric 3 C RIP C RIP 2 Multicast C RIP 2 Broadcast r RIP Password pe RIP Compatibility This set of radio buttons is used to select which version of RIP that the Datacryptor Ethernet is using e Off this switches off compatibility with any version of RIP No RIP messages transmitted on any port e RIP 1 select this if you wish the Datacryptor to be compatible with the first version of RIP This version of RIP only uses broadcasts to pass on information e RIP 2 multicast this sets the Datacryptor to be compatible with RIP version 2 when used in multicast mode The multicast mode was implemented with the more versatile RIP 2 1270A450 005 June 2008 Page 73 Element Manager Reference Datacryptor Ethernet User Manual e RIP 2 broadcast this sets the Datacryptor to be compatible with RIP version 2 but uses the broadcast mode Some networks that are using RIP 1 may want to use RIP 2 but not use multicast transmissio
85. h a non commissioned unit slave unit Key 28 228 Major Diffie Hellman parameters do not match Generated at Unsuccessful attempt to generate a KEK due to no matching Diffie Hellman parameters Key 29 229 Major No own unit certificate installed Generated by slave unit when a master unit is attempting to performa Key Exchange The slave unit does not contain a valid Key set Key 30 230 Major No common certificates Unit does not contain a matching certificate that can be used to authenticate and communicate with remote unit Key 31 231 Minor Certificate exchange unsuccessful Generated by master unit when attempting to perform a Key Exchange with a unit slave which does not contain matching certificate that can be used to authenticate and communicate with remote unit Page 112 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Key 32 232 Minor Certificate exchange Generated by master unit unsuccessful when attempting to perform a Key Exchange with a unit slave which is with an invalid certificate Key 33 233 Minor Certificate exchange Unexpected time out in unsuccessful key exchange connection may be lost or units may be busy Key 34 234 Minor Certificate exchange Unexpected time out in unsuccess
86. hs across the network by the addition of label information to a packet to aid routing etc It is referred to as multi protocol because it supports a number of communication methods such as IP Frame Relay and ATM The Datacryptor Ethernet unit is transparent to this operation as long as the equipment is being deployed in a point to point environment Page 18 THALES Datacryptor Ethernet User Manual Installation 5 Installation This section will detail the installation of the hardware and software Hardware installation is discussed first Hardware Installation There are four steps in installing the unit e Unpack the Shipping Carton e Mount the Unit e Connect the Cables e Power on the Datacryptor Unpack the Shipping Carton Remove all product components from the shipping carton and compare the contents to the packing list Keep all packaging in case it is necessary to return the appliance The Datacryptor is packaged with the following items e Datacryptor Ethernet with the Datacryptor firmware and software factory installed on the appliance e 115v 240v or DC Power Supply cables as appropriate e RS 232 cable e Element Manager CD ROM includes User Manual e Release Notes e Quick Start Guide Note Interface transceivers if ordered will be shipped separately from the Datacryptor unit 1 Gig and 10 Gig Ethernet units only Rack Mounting Instructions The Datacryptor can be mounted in a standard 19 inch rack
87. in 2 aA mA mA AR er naar mie s n on mmm 10 03 12 27 05 2005 There is only one log but it contains data of four different types e Audit A report of all management operations performed on this unit using the Element Manager e Error A report of any faults that have been discovered with unit hardware and keyspace e Key A report of all key update and erasure attempts Page 54 THALES Datacryptor Ethernet User Manual Element Manager Reference e Trace A report of internal software conditions detected by the unit these are not hardware errors but may help support personnel understand unusual operational conditions They appear on the display as Internal Error but when saved to disk as a text file the text is expanded When seen these should be reported to the Support department at Thales e Security for investigation Note New errors will cause the Error LED to flash Once they have been read the Error LED will change to ON and stay on until they have been cleared out of the log A list of all the log and SNMP trap numbers with descriptions is provided as an appendix to this guide The Logs window provides facilities through three pull down menus The Log menu provides e Clear Entries clear all entries from the currently displayed log s typically after saving them first e Save As save the currently displayed log s in a named file You can then keep the file as a backup print it or process as
88. information on the hardware and software Background Information provides a brief introduction to the device and Ethernet Layer 2 technology and terminology Installation describes how to install the Datacryptor Ethernet hardware and Element Manager Software Connecting to Datacryptor Ethernet Units describes the main methods that can be used to connect the PC to the Datacryptor Ethernet unit Element Manager Reference provides an overview of the functions provided by the Element Manager followed by a detailed description of each in turn Appendix A Device Maintenance describes the periodic maintenance required on your Thales Datacryptor Ethernet unit Appendix B Loading Datacryptor Unit Software describes how to load software into your Thales Datacryptor Ethernet unit Your Datacryptor will be supplied pre loaded with software so you will only require the information in this appendix if a re load or upgrade is needed Appendix C Product Specifications gives the system specifications Appendix D Environment and Regulatory Information describes the operating conditions and regulatory certifications Appendix E SFP and XFP Interfaces describes the possible transceiver options Appendix F Preventing Electrostatic Discharge describes how to minimize the risk of ESD Appendix G Troubleshooting describes how to diagnose and repair common problems Appendix H SNMP MIB Support describes the SNMP MIBs
89. ing Peer unit on the Ethernet encryption tab to confirm connectivity Use the loopback mode to test the connections see The Diagnostics Tab on page 59 Fan Heat Monitor Alarm Symptom Explanation and Possible Solutions Fan Heat Monitor Alarm Consult the Environment tab on the Properties dialog for readings of the fan speeds and unit temperature Compare these readings to those recorded during normal operation to determine the nature of the problem Verify that nothing has become inserted in the fan or ventilation holes which could restrict the fan operation or airflow In a normal working environment i e setup in accordance with the rack mounting instructions the unit is able to function correctly with a fan or fans disabled If the condition persists then it could indicate that the temperature is above the level required for reliable operation and the unit should be returned to Thales for investigation Repair 1270A450 005 June 2008 Page 101 Appendix H SNMP MIB Support Datacryptor Ethernet User Manual Appendix H SNMP MIB Support In order to support organizations who utilize SNMP to monitor network devices and status the Datacryptor Ethernet product does provide a Simple Network Management Protocol Version 3 SNMPv3 and Management Information Base II MIB II interface The SNMPv3 implementation is based upon RFCs 1157 1901 1910 2576 2578 2580 and 3411 3418 The MIB II interf
90. inimum requirements for running the following version of Microsoft Windows Microsoft Windows XP Service Pack 2 or higher 32 and 64 bit versions Note The software may install and run on older Windows platforms but due to Microsoft s Support Lifecycle policy we may be unable to support installation and runtime issues on these older platforms Please refer to the Microsoft Support Lifecycle support web page at http support microsoft com gp lifecycle 1270A450 005 June 2008 Page 23 Installation Datacryptor Ethernet User Manual e The PC must have a pointing device mouse a CD ROM drive a free serial port and at least 228 Mb hard disk space for the software and data files If you want to install the Adobe Acrobat reader included on the CD to view the manuals this will require a further 10 MB of hard disk space e The user should ensure that there is at least 5Mb of memory for each copy of the Front Panel Viewer being run concurrently e The PC must be able to reach the Datacryptor on the Ethernet network or alternatively be connected to the unit via a serial cable to the unit s control port Installation Procedure To install the Element Manager on the PC e Insert the CD ROM containing the Element Manager software into your PC e This will auto start the installation page Select the Install the Datacryptor Element Manager Software link OR run the program setup exe from the root directory on the CD e F
91. ion movement Unit recovered from alarm Hardware alarm activated and noted movement alarm had been activated it will be necessary to reboot the unit If alarm persists contact Thales esecurity Support Error 15 122 Major Alarm condition Unit recovered from alarm Hardware temperature alarm activated and noted temperature alarm had been activated it will be necessary to reboot the unit If alarm persists contact Thales esecurity Support Error 16 122 Major Alarm condition erase Unit recovered from alarm Hardware button activated and noted erase button alarm had been activated it will be necessary to reboot the unit If alarm persists contact Thales esecurity Support Error 17 122 Major Alarm condition battery low Unit recovered from alarm Hardware and noted that the battery low alarm had been activated it will be necessary to reboot the unit If alarm persists contact Thales e security support Error 18 122 Major Alarm condition secure Unit recovered from alarm Hardware memory was erased and noted intrusion detection alarm had been activated it will be necessary to reboot unit If alarm persists contact Thales e security support Error 121 Minor Random no gen fault clear Random number Hardware generator fault cleared cleared Error 2 121 Minor Real time clock fault clear Real time clock fault Hardware cleared cleared Error 3 121 Minor RAM fault cleared RAM fault cleared Hardware clea
92. ion disabled Audit 158 883 Informational Add SA denied unsupported mode Audit 159 884 Informational Remote Client Relay configuration updated Audit 160 885 Informational Remote Client Relay configuration update failed Audit 161 886 Informational ACL configuration updated Audit 162 887 Informational ACL configuration update failed Audit 165 890 Informational SA Deleted by ACL Audit 900 891 Informational SONET configuration updated Audit 901 892 Informational SONET path hierarchy updated Audit 902 893 Informational SONET path encryption mode updated Audit 903 894 Informational SONET path overhead mode updated Audit 905 896 Informational Ethernet configuration updated Audit 906 897 Informational Ethernet LAN configuration updated Audit 907 898 Informational Ethernet security configuration updated Audit 908 899 Informational License installed Audit 909 900 Informational Reverted to default license Audit 910 901 Informational Private loopback enabled Audit 911 902 Informational Private loopback disabled Audit 912 903 Informational Public loopback enabled Audit 913 904 Informational Public loopback disabled Page 130 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Audit 914 905 Critical Hardware Monitor report
93. ional DEK installed Key 2002 602 Informational KEK installed Key 2003 603 Informational Installed CA certificate Key 2004 604 Informational Expired CA certificate Key 2005 605 Informational Removed CA certificate Key 2006 606 Informational Installed unit certificate Key 2007 607 Informational Expired unit certificate Key 2008 608 Informational Removed unit certificate Key 2009 609 Informational Installed peer certificate Key 2010 610 Informational Expired peer certificate Key 2011 611 Informational Removed peer certificate Key 2012 612 Informational Standby mode set Key 2013 613 Informational Plain mode set Key 2014 614 Informational Encrypt mode set Key 2015 615 Informational Previous unit name Unit name Changed Previous unit name Key 2016 606 Informational New unit name Unit name Changed New unit name Key 2017 617 Informational New DEK exchanged 1270A450 005 June 2008 Page 119 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Key 2018 618 Minor No Encrypt channel is The maximum number of available encrypt slots has been reached Key 2019 619 Informational DLCI has become Active LMI Key 2020 620 Informational DLCI has become Inactive LMI Key 2021 621 Informational Red KEK
94. it C No l wish to remain under the existing CA want to transfer control to a new may demo KeyM aterial Iniversal cac cy Browse Units are normally delivered under the control of the manufacturer CA DC2K Manufacturer with the Universal CA available on disk this dialog allows you to transfer control to a different custom CA 1 To stay under the control of the manufacturer CA select the No option and click the Next button or press Enter This will take you to step 3 2 To transfer from the manufacturer CA to a new CA select the Yes option Insert the diskette containing the new CA s CAC file and enter the path to the CAC file or use the Browse button to find it Click the Next button to proceed to step 2 Page 48 THALES Datacryptor Ethernet User Manual Element Manager Reference Step 2 Installing the authenticating CA Commission Datacryptor Wizard This process will require a Certificate Authority to authenticate the changes being made Select your Certificate Authority and press the Next gt button to continue Jemo KeyM aterial Universal ca Sy Browse Insert the diskette containing the authenticating CA s CA file and enter the path to the CA file or use the Browse button to find it Click the Next button to proceed to step 3 1270A450 005 June 2008 Page 49 Element Manager Reference Datacryptor Ethernet User Manual Step 3 Setting the unit name Commission Datacryptor Wizard
95. it Pause frames can still be used with the 10Gig Ethernet unit but this will not be auto negotiated and would still require the configuration of a rule to pass pause frames in the plain Auto Negotiation allows the unit to automatically negotiate connection without intervention from the user Note The Datacryptor 1 Gig Ethernet only supports 1000 Mbps full duplex and the 10 Gig Ethernet unit only supports 10 000 Mbps full duplex The 100 Mb unit supports a selection of one 10 Mbps or 100 Mbps Anything else will cause the auto negotiation if selected to fail and report Link Down on the General tab interface status box The Auto Negotiation tick box is not displayed for the 10Gig Ethernet unit since the 10Gig Ethernet unit does not support auto negotiation Frame Checksum If the FCS box is checked then the checksum is stripped off the incoming frame and added again for outgoing frames When the FCS box is not checked the FCS is treated like normal data will be and encrypted and decrypted like data on the public interface The FPV imposes the following defaults when switching modes When switching from Bulk to Tunneling the Network FCS is checked When switching from Tunneling to Bulk the Network FCS is unchecked It is advised that the user accepts these default settings Status Shows the current status of the Host and network interfaces Page 76 THALES Datacryptor Ethernet User Manual Element Manager Reference The Ethernet Co
96. ivered in the United States Latin America or Canada the laws of the State of Virginia YOU ACKNOWLEDGE THAT YOU HAVE READ THIS LICENSE AGREEMENT UNDERSTAND IT AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS YOU FURTHER AGREE THAT IT IS THE COMPLETE AND EXCLUSIVE STATEMENT OF THE AGREEMENT BETWEEN YOU AND THALES WHICH SUPERSEDES ANY PRIOR PROPOSAL REPRESENTATION OR UNDERSTANDING ORAL OR WRITTEN BETWEEN US RELATING TO THE SOFTWARE OR FIRMWARE NOTWITHSTANDING THE ABOVE IF YOU PREVIOUSLY SIGNED A SEPARATE AGREEMENT HAVING A SOFTWARE LICENSE PROVISION APPLICABLE TO THIS PROGRAM WHICH HAS NOT EXPIRED OR BEEN TERMINATED THE TERMS AND CONDITIONS OF SUCH SEPARATE AGREEMENT AND THE SOFTWARE LICENSE CONTAINED THEREIN SHALL TAKE PRECEDENCE OVER ALL CONFLICTING TERMS AND CONDITIONS IF ANY CONTAINED IN THIS LICENSE AGREEMENT OTHERWISE ANY ADDITIONAL TERMS AND CONDITIONS SET FORTH IN THIS LICENSE AGREEMENT SHALL SUPPLEMENT AND BE READ IN CONJUNCTION WITH THE SOFTWARE LICENSE CONTAINED IN ANY SUCH SEPARATE AGREEMENT Hardware Warranty The period of warranty for this product starts on the date of sale to the original purchaser and ends 365 days thereafter Thales e Security will replace any product that fails within 90 days of the date of sale For failures which occur more than 90 days after the date of sale Thales e Security will repair the product if returned postage prepaid to our designated repair center Thales e Security requires a Return
97. l signatures using the DSA public key algorithm and the SHA 1 hash algorithm DSA An abbreviation for Digital Signature Algorithm It is an algorithm used for authentication only DSA public parameters Parameters used to generate and check DSA digital signatures Page 132 Datacryptor Ethernet User Manual Appendix J Glossary of Terms Element Manager EM Application used to manage Datacryptor Ethernet devices and is used to launch the Front Panel Viewer FPV application Encrypted data Transformed plaintext data to ciphertext Encryption Data encryption scrambles and unscrambles data between two communication endpoints The encryption process turns an original plaintext message that anyone can read into an encrypted ciphertext message that can be read only by an authorized recipient Framing Method of distinguishing digital channels that have been multiplexed together Front Panel Viewer FPV Is the application that authenticates the administrator with a Datacryptor Ethernet and allows it to be commissioned and managed Hash Function An algorithm that computes a short digest of a longer message The digest is usually of a fixed size Hash Message Authentication Code A secret key authentication algorithm If only the source and destination know the HMAC key the algorithm provides data origin HMAC authentication and data integrity for packe
98. mm Tab for 100 Mb Datacryptor The properties on the Ethernet Comm tab control the communications settings of the Datacryptor unit E Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethernet Comm Ethernet Encryption Environment Expert General Mode Bulk q NOTE The unit must be rebooted after changing the mode Interface Network Mode Link Mode Speed configured Pause Auto Negotiation Frame CheckSum Status They are as follows Mode Selects one of two options for the transmission mode Bulk Unit encrypts everything including Ethernet header Tunneling Unit encrypts every thing below Ethernet header When a mode change is made then the following dialog will be shown advising that the unit must be rebooted 1270A450 005 June 2008 Page 77 Element Manager Reference Datacryptor Ethernet User Manual Datacryptor 1 1 1 1 You will need to re boot the Datacryptor for the changes to take effect The unit can be rebooted using the option available on the Diagnostic tab Interface Mode Allows the Host and network interfaces to be switched Up Down Link Mode Allows the Host and network connections to be individually switched On Off If the LLCF option is selected the connection is on with link loss carry forward turned on Auto Negotiation allows the unit to automatically negotiate connection without intervention from the user Not
99. mounts of data to be transferred from the unit under management and may degrade system performance The Save and Load buttons provide a convenient way to set up a number of similar units as well as a convenient way to keep backups of unit settings Page 58 THALES Datacryptor Ethernet User Manual Element Manager Reference The Diagnostics Tab The Diagnostics tab will provide a range of diagnostic aids f Properties 1 1 1 1 Ethernet Comm Ethernet Encryption Environment Expert General Security Diagnostics IP Management RIP Reboots the Datacryptor If the Reboot management application uses Dialup Networking it will need to be re started Instructs the Datacryptor to erase its key Erase material The Datacryptor should then be rebooted Loopback Creates a line loop back between this unit Network and its peer used to troubleshoot the link Host Creates a line loop back between this unit and its local network Currently it provides two diagnostic facilities Reboot click this button to reboot the unit as if it had been turned off and on again This operation takes several minutes Rebooting halts all operations on the device and starts the boot process in the same manner as when the power is cycled Save any configuration changes prior to rebooting the unit Unsaved changes will be lost 1270A450 005 June 2008 Page 59 Element Manager Reference Datacryptor Ethernet User Manu
100. n key exchange connection may be lost or units may be busy Key 20 220 Major No common KEK algorithm Units do not have common KEK algorithm and so do not continue negotiation Key 21 221 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 22 222 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy 1270A450 005 June 2008 Page 111 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap No Severity Message Information Key 23 223 Minor Certificate exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 24 224 Minor Certificate exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 25 225 Minor Certificate exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 26 226 Minor Certificate exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 27 227 Major Peer has no own unit certificates installed Generated by master unit when attempting to perform a Key Exchange wit
101. n waiting for Key exchange request connection may be lost or units may be busy Key Key 201 Major No common DEK algorithm Units do not have common symmetric encryption algorithm and so do not continue negotiation Key 202 Warning DEK exchange unsuccessful DEK response did not match challenge Diffie Hellman parameters may be mismatched Key 203 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 204 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 205 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 206 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 207 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 208 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 209 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 10 210 Minor DEK exchange unsuccessful Unex
102. nection may be lost or units may be busy Key 1041 541 Warning Peer reported commissioning Unexpected time out in unsuccessful protocol connection may be lost or units may be busy 1270A450 005 June 2008 Page 117 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Key 1042 542 Warning Peer reported commissioning Unexpected time out in unsuccessful protocol connection may be lost or units may be busy Key 1044 544 Minor Management Session already in progress Key 1045 545 Major Peer reported key exchange Key exchange process is already in progress busy the unit must try again later Key 1046 546 Minor Peer reported key exchange Key exchange process is already in progress busy the unit must try again later Key 1047 547 Major Peer reported an View unit logs for more unknown missing error information Key 1049 549 Warning Failed to set peer s mode Key 1050 550 Warning Failed to set peer s mode Key 1051 55 Major PEER DEK installation failed Key 1052 552 Major PEER Failed to set line mode Key 1053 553 Major PEER Receive and transmit keys are identical Key 1054 554 Major Peer has no KEK algorithm PEER Failed KEK Known loaded or it is operating Answer Test incorrectly Key 1055 555 Major Peer has no DEK algorithm PEER Failed DEK Known loaded or it
103. nit to reboot to attempt to recover Audit 80 767 Major Hot Standby reboot Failed to Hot Standby unit change IP address changing of an IP address appears to have failed and has caused the unit to reboot to attempt to recover Audit 81 768 Major Detected Primary failure No Secondary unit has response from Public virtual detected Primary unit IP address failure on Network public port side Audit 82 769 Major Detected primary failure No Secondary unit has response from Private virtual detected Primary unit IP address failure on Host private port side Audit 83 770 Major Primary Response back from Hot standby primary unit Public virtual IP address has detected itself probable configuration error on public side Page 126 THALES Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap Severity Message Information No Audit 84 771 Major Primary Response back from Hot standby primary unit Private virtual IP address has detected itself probable configuration error on private side Audit 85 772 Major Primary attempt failed No Hot standby Secondary response from Private known unit attempted to be come IP address primary and failed as no response was received from known address on host private port Audit 86 773 Major Primary attempt failed No Hot standby Secondary response from
104. nization regardless of quantity provided all Machines are located within a single country A separate single or organizational license will be required in each country B You may not decompile reverse engineer modify or copy the Software Firmware or Documentation for any purpose except you may copy the Software into machine readable or printed form for backup purposes in the event the CD ROM or other provided media is damaged or destroyed You may combine the Software with other programs Any portion of the Software merged into or used in conjunction with another program will continue to be the property of THALES and is subject to the terms and conditions of this Agreement C The Software Firmware and the Documentation are copyrighted by THALES and or its suppliers You agree to respect and not to remove or conceal from view any copyright or trademark notice appearing on the Software Firmware or Documentation and to reproduce any such copyright or trademark notice on all copies of the Software Firmware and Documentation or any portion thereof made by you as permitted hereunder and on all portions contained in or merged into other programs and documentation D You may transfer the Software Firmware and this license to another party if the other party agrees to accept the terms and conditions of this Agreement If you transfer the Software and or Firmware you must at the same time either transfer all copies whether in printed or machine
105. ns This will ensure that RIP responses are not addressed to multicast address 224 0 0 9 Note IGMP is not needed since these are inter route messages that are not forwarded Metric This sets the metric or cost that is associated to each route that is advertised in RIP responses sent out by the Datacryptor unit Generate Authentication Entries RIP 2 can implement an authentication entry in the first part of its response that contains a password If a router matches its own RIP password with that of the RIP response authentication entry it will accept the routing information in the RIP response Tick this check box to enable the inclusion of authentication entries in RIP 2 messages sent from the Datacryptor Ethernet Password This field contains the password to be associated with the authentication entry Page 74 THALES Datacryptor Ethernet User Manual Element Manager Reference The Ethernet Comm Tab for 1 and 10 Gigabit Datacryptors The properties on the Ethernet Comm tab control the communications settings of the Datacryptor unit The Comm tab illustrated in this section applies to the 1 Gig Ethernet unit Differences between the 1 Gig and 10 Gig units will be stated where relevant Ir Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethernet Comm Ethemet Encryption Environment Expert General Mode Bulk q NOTE The unit must be rebooted after changing the mode Interface
106. nts The following table outlines the cabling requirements for each port on the Datacryptor Ethernet The connector type listed indicates only what is required to connect to the Datacryptor s port and may or may not be the same connector type required for the other end of the cable Page 20 Datacryptor Ethernet User Manual Installation Port Cabling Supplied By Network and Host For the 100 Mb Ethernet unit Category 5 or above Customer Port RJ 45 connector For the 1 Gig and 10 Gig Ethernet units Dependant on the SFPs or XFPs ordered with the unit The options are Category 5 or above RJ 45 connector 850nm Multi mode fiber 1310nm or 1550nm Single mode fiber 10 100 Ethernet Shielded Category 5 straight through cable STP RJ 45 Customer Management Port connector Used when connecting through a LAN Category 5 crossover cable with RJ 45 connector Customer Required for a direct connection between the management station and the Datacryptor RS 232 Craft Port Shielded copper serial cable RS 232 DB9 connector Thales female to male Power receptacles Power supply cables Thales To meet the requirements of FCC Part 15 and the Directive 89 336 EEEU EMC C use only shielded cables DB 9 null modem cables and Category 5 STP cables To Cable the Datacryptor The Host and Network interface transceivers that are used with the 1 Gig and 10 Gig Ethernet units are shipped separately from the Datacrypt
107. o be secure and need to be authenticated using secure methods Certificates are loaded into the Datacryptor Ethernet units that have keys used to sign messages between the PC used for configuration and the units themselves The AES keys used to encrypt and decrypt the data being passed between Datacryptor units are automatically generated using Diffie Hellman and the supplied Diffie Hellman parameters When first installing the Datacryptor use the default password Thales strongly recommends that the Administrator changes the password before the unit is put in service and changes from the Universal CA to their own custom CA to ensure maximum security see the Change Password dialog section Passwords are case sensitive IP Parameter Configuration via a Serial Connection When shipped a Datacryptor Ethernet device has the following port settings Port IP address Net Mask Control 2 2 2 2 255 0 0 0 Ethernet management 255 0 0 0 255 255 255 255 Network n n n 255 0 0 0 To change the parameters follow the steps below 1 Connect the Datacryptor s RS 232 craft port directly to the terminal s serial port using the supplied DB 9 serial cable 1270A450 005 June 2008 Page 25 Connecting to Datacryptor Ethernet Units Datacryptor Ethernet User Manual 2 Open a terminal session through a VT 100 terminal emulation program such as HyperTerminal Enter the connection name the appropriate serial port usually COMI or
108. o delete by clicking on it and then click the Delete button Datacryptor 1 1 1 1 SNMPv3 Users SNMP Version 3 supports an access control model based upon users and views Management of these users and views is controlled using native SNMPv3 commands Please utilize your existing SNMPv3 management tools to manage user and view based access control Management of the SNMPv3 users is a time consuming task and you should set your command timeout values to at least 120 seconds per transaction Default SNMPv3 user information is displayed in the table below Type Value User Name initial Authentication Password authentic Privacy Password private8 Page 64 THALES Datacryptor Ethernet User Manual Element Manager Reference Traps Tab The Traps tab lists the details of each SNMP trap that has been defined for this unit and provides facilities to maintain the list SNMP Config 1 1 1 1 Agent Configuration Traps SNMP Trap Version Support Enable SNMP 1 Traps Enable SNMPv2 Traps Enable SNMPv3 Traps SNMPv1 Traps 1 SNMPv2 Traps 1 SNMPv3 Traps 3 IP Address Community Info Waring Min Major Critical private Disabled Enabled Disabled Enabled Enabled To enable or disable SNMP traps for this unit use the appropriate Enable checkboxes for the each version of SNMP When defining an SNMP Trap that is not on a local network connection the Datacryptor Ethernet
109. ollow the instructions displayed by the installation manager Page 24 THALES Datacryptor Ethernet User Manual Connecting to Datacryptor Ethernet Units 6 Connecting to Datacryptor Ethernet Units There are three methods of connecting to the Datacryptor Ethernet units Element Manager serial connection to CLI and SNMP The Element Manager GUI application is used to manage and configure the Datacryptor Ethernet device s It connects to the Datacryptor via the 10 100 Ethernet Management port A serial connection can be made to the Datacryptor Ethernet to interface to a text based Command Line Interface CLI This serial interface can also be used to access the element manager software A third party SNMP Version 1 Version 2c or Version 3 compliant network management application can collect and display performance monitoring data but may not alter any system level parameters The only supported configuration tasks are those associated with SNMPv3 user and view based access control SNMP traps are issued as Version 3 and authentication and encryption are supported Users The Datacryptor Ethernet will encrypt everything passed to it from the host network and place it onto the public network Because of this there is no need to create secure users for the Datacryptor Ethernet as anyone sending information will automatically use the Datacryptor Ethernet unit The people who administrate and configure the Datacryptor Ethernet do need t
110. onstructs an exact sequence of network events or device operations The audit log configuration determines the types of events that it records The Logs Window which is displayed by clicking on the View Logs button in the Front Panel View allows you to view search save or clear the log recorded by the selected unit C Logs 1 1 1 1 Log View Help No Time Date Er type _ Evert ovde Use Deeured 10 03 12 27 05 2005 Viewed logs Admin 2 10 03 01 27 05 2005 DEK installed ae 437210000008 10 02 51 27 05 2005 New DEK exchanged 2017 437210000008 10 02 31 27 05 2005 i Session started 1 Admin 2 10 02 31 27 05 2005 DEK installed 2001 Admin 2 10 02 31 27 05 2005 KEK installed 2002 Admin 2 10 01 59 27 05 2005 DEK installed 2001 437210000008 10 01 49 27 05 2005 New DEK exchanged 2017 437210000008 10 00 57 27 05 2005 DEK installed 2001 437210000008 10 00 47 27 05 2005 New DEK exchanged 2017 437210000008 09 59 57 27 05 2005 Encrypt mode set 2014 437210000008 09 59 57 27 05 2005 DEK installed 2001 437210000008 09 59 45 27 05 2005 New DEK exchanged 2017 437210000008 09 59 44 27 05 2005 KEK installed 2002 437210000008 09 59 11 27 05 2005 i System startup 23 System 17 01 02 25 05 2005 i Session stopped 2 Admin 2 17 00 54 25 05 2005 DEK installed 2001 437210000008 17 00 45 25 05 2005 New DEK exchanged 2017 437210000008 17 00 43 25 05 2005 DEK installed 2001 Admin 2 13 56 33 25 05 2005 KEK installed 2002 Adm
111. or unit and therefore must be inserted before proceeding with the cabling operation The connections are the same when using any of the three types of Ethernet unit The illustration below shows a 1 Gig Ethernet unit please note that the management ports of the 100 Mb Ethernet unit are on its front panel e Either connect the RS 232 craft port directly to a PC or workstation using the supplied DB 9 null modem cable or e Connect the 10 100 Ethernet management port for management access If connecting to a LAN use a Category 5 STP straight through cable with an RJ 45 connector If connecting directly to a PC use a shielded Category 5 crossover cable and make sure that the PC and management port IP addresses are on the same subnet 1270A450 005 June 2008 Page 21 Installation Datacryptor Ethernet User Manual pa Host port connected J to a trusted network jj Network port connected B Switch to a peer unit Datacryptor Gig Ethernet THALES Network ryp g S s S emu SE Ss uv CS amp SS SS S FP SF QUE H Management workstation on RS 232 connection Management workstation 7 C AY on Ethernet connection 7 NS N Figure 5 1 Datacryptor Panel Connectors The 100 Mb Ethernet unit s management ports are located on the front panel WARNING 1 Gig and 10 Gig Ethernet units only Infra red radiation is emitted from aperture ports of single mode or multi mode transceivers when no cable is connecte
112. ork to Host ports Selecting the New Rule button will open the Filter Rule dialog When setting a rule the first step is to select a rule type E Filter Rule Rule Fields Type 7 Block Wer S eft Destinator Mac SOEs Source MAC Address Hi B Zz wildcard value OK Cancel Rule Type e Plain this allows the Datacryptor unit to pass information from the specified addresses in plain and is used to allow network specific traffic To ensure compatibility and operation of equipment within the public network e Block this option identifies individual addresses or a range of addresses which are to be denied access by the Datacryptor unit The second step is then to set the destination and source MAC addresses LI Filter Rule Rule Fields Type Destination MAC Address B0 B1 B2 B3 B4 B5 Source MAC Address a0 jal a2 a3 a4 a5 wildcard value OK Cancel 1270A450 005 June 2008 Page 83 Element Manager Reference Datacryptor Ethernet User Manual MAC Address The destination and source addresses are standard MAC addresses with the added option of using the wildcard character see below to enable a range of addresses to be identified Filter Rule Rule Fields Type Destination MAC Address B0 3 i B2 2 B3 B5 Source MAC Address jal a2 a3 ad m wildcard value DK Cancel When you hav
113. ot be acquired by the government in a contract incorporating clauses prescribed by DFARS Subpart 227 4 OCT 1988 in which case the government hereby agrees to return the software unused in exchange for refund of the full purchase price 1270A450 005 June 2008 Page 7 Preface Datacryptor Ethernet User Manual The government agrees that it shall be bound by the terms and conditions of this license agreement to the maximum extent possible under federal law This license agreement and the governments assent hereto supersedes any contrary terms or conditions in other contract documents such as any statement of work EXPORT AUTHORIZATIONS You shall assume all responsibility for obtaining any required export authorizations necessary to export any Software and or Firmware and Documentation purchased hereunder You shall not re export Software and or Documentation directly or through others or the product of such data to the prescribed countries for which such prohibition exists pursuant to the U S or U K export regulations unless properly authorized by the appropriate government GENERAL You may not sublicense assign or transfer this license Software Firmware Documentation or Key except as expressly provided in this Agreement Any attempt otherwise to sublicense assign or transfer any of the rights duties or obligations hereunder is void This Agreement will be governed by the laws of England or the event that the Product was del
114. own possible disconnection IP address from private network Audit 74 761 Major Primary Mode Failure No Hot standby unit detected response from Public known possible disconnection IP address from public network 1270A450 005 June 2008 Page 125 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Audit 75 762 Critical Primary mode reboot KAT The encryption algorithm test failure failed a Known Answer Test KAT and has caused the unit to reboot to attempt to recover Audit 76 763 Critical Secondary mode reboot KAT The encryption algorithm test failure failed a Known Answer Test KAT and has caused the unit to reboot to attempt to recover Audit 77 764 Major Hot Standby reboot FPGA Hot standby unit has stats mismatch detected a possible problem with the encryption device and has caused the unit to reboot to attempt to recover Audit 78 765 Major Hot Standby reboot No Hot standby unit may response from Private CR have detected problem with Host Private port Ethernet interface which appears to have stopped responding and has caused the unit to reboot to attempt to recover Audit 79 766 Major Hot Standby reboot No Hot standby unit may response from Public CR have detected problem with Network Public port Ethernet interface which appears to have stopped responding and has caused the u
115. ox provided on the relevant property tab Frame Checksum FCS FCS is an error detection system based on the numerical value of the number of set bits in the Frame packet This value is transmitted alongside the message and the receiving device then applies the same criteria and compares the two values Auto negotiation Auto negotiation was devised to address the need for multi speed devices on a network to operate at the optimum settings It achieves this by taking control of the connection medium and detecting the various mode options available in the device on the other end while also advertising its own capabilities Thus it enables the connection to configure the highest performance mode of interoperation Note The Datacryptor 1 Gig Ethernet only supports 1000 Mbps full duplex and the 10 Gig Ethernet unit only supports 10 000 Mbps full duplex The 100 Mb Ethernet unit can be set to run at speeds of IO Mbps and 100 Mbps The 10 Gig Ethernet unit does not support Auto negotiation Jumbo frames Jumbo frame is the name given to frames larger than the standard Ethernet MTU of 1500 bytes The Datacryptor Ethernet encryptor does not have an MTU limit and will therefore allow Jumbo frames Frame size is only limited if fragmentation is enabled Multiprotocol Label Switching MPLS is a solution to the question of many of the earlier network problems such as speed scalability and quality of service This is achieved by the defining of pat
116. pected time out in key exchange connection may be lost or units may be busy Page 110 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Log Type Code Trap No Severity Message Information Key 11 211 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 12 212 Minor DEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 13 213 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 14 214 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 15 215 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 16 216 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 17 217 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 18 218 Minor KEK exchange unsuccessful Unexpected time out in key exchange connection may be lost or units may be busy Key 19 219 Minor KEK exchange unsuccessful Unexpected time out i
117. pgrade Settings Serial COM 1 default ee Ethernet 192 158 200 52 Status Messages Datacryptor Image Upgrade utility Version 4 4 0 5 Session started 10 35 14 AM 19 July 2007 Read Loading de2k sig Upload Progress 5o Help Start Upgrade Close 1270A450 005 June 2008 Page 93 Appendix B Loading Datacryptor Unit Software Datacryptor Ethernet User Manual Completing the Upload 1 Progress of the load is shown via the Upload Progress bar and you will be notified when this is finished If Save Log Events was selected a dialog will now prompt you for the file name and location for saving the log file Save Log File Note Look in 5 1 11 1810 B My Recent Documents My Documents My Computer My Network Places Files of type bet text v Upload of the application is complete click Close to shut down the application or connect another Datacryptor for loading After the application has been loaded and the unit reboots the algorithm will need to be loaded into the unit See the section Commissioning for more information Some algorithms may have to be loaded at the factory or under secure conditions Page 94 Datacryptor Ethernet User Manual Appendix C Product Specifications Appendix C Product Specifications System Specifications Interfaces Host and network ports see Appendix E for transceiver detail
118. r You can also use the Change Password button to change your password providing you know the original password Change Password Dialog This dialog is displayed when you select the Change Password button from the Login dialog Change Login Password Old Password New Password XXXXXXXXNXNXXX Re type New Password Ser Key Material o KeyMaterialNadminv2 usr E gt Browse Type the current password in the Old Password text box and enter the new password in the New Password and Re type New Password text boxes The basic password requirement is that it must be 8 to 28 case sensitive alphanumeric characters However to determine the full requirements that must be met when choosing a password you should refer to the Password Format Check section in Configure Dialog 1270A450 005 June 2008 Page 53 Element Manager Reference Datacryptor Ethernet User Manual CAUTION If the password is lost all Administrator functionality is lost including the ability to assign a new password The only means of resetting the A password is to the restore the factory settings on the device please call Customer Service for support This operation overwrites all previously saved configurations policies and keys with factory defaults Logs Window The Datacryptor Ethernet monitors network operations and records information in an audit log about network events or operations specific to a device The audit log rec
119. r The management facilities are provided by the View Logs and Properties buttons If View Logs or the Properties buttons are grayed out they are inaccessible because you haven t logged in yet use the Login button to do so Once you have logged in the Login button changes to Logout The Front Panel Viewer displays the following information e The IP address of the unit management port in the title bar e The model description e Unit Name read from the unit Management Version read from the application e Application Version read from the unit e Bootstrap Version Firmware number e Serial Number Unit unique serial number e In the blue rectangle a diagram of the unit s front panel shows the state of the LEDs which can be examined to check the state of the unit see the Front Panel LEDs section In addition if you move the mouse pointer to an LED after a few seconds a description of its current state will be displayed next to it in a yellow box e Beneath the blue rectangle is the Automatically Poll LEDs checkbox Tick this to update the display of the LED status every 10 seconds or clear it to stop the polling and reduce the network traffic Page 40 Datacryptor Ethernet User Manual Element Manager Reference e Beneath the front panel diagram are five large buttons that provide direct access to management facilities see the Front Panel Viewer buttons section below Note Pressing F5 while using the
120. ram via the serial Control port using Dial up Networking 1 Ensure a serial cable is connected between your PC and the Datacryptor Ethernet unit 2 Use the Networking wizard for your operating system to generate a Dial up connection the following parameters should be used for the settings Set up an advanced connection Connect directly to another computer Guest Connection Name Select the Com port to which you have connected the serial cable All users User Name and Password 3 Select the option for Desktop shortcut 4 Select Finish 1270A450 005 June 2008 Page 27 Connecting to Datacryptor Ethernet Units Datacryptor Ethernet User Manual Click on the shortcut to launch the connection Select the Properties button On the General tab confirm correct connection aN oro Click Configure button and use the menu to set the maximum connection speed of 115200 bps Set the flow control to none the Ethernet and SONET do not support flow control 9 On the Network tab select TCP IP and click Properties enter the address 2 2 2 1 10 Close down the Properties and click Connect 11 A connection with the Datacryptor Ethernet will be made Ensure the connection is made then disconnect Adding a Unit to Element Manager Once the Management or Dial up connection is set up you can connect to each Datacryptor Ethernet unit by adding an icon in the Element Manager The Dial Up connection created earlier
121. readable form and the Machine if any on which the Firmware is licensed for use to the same party or destroy any copies not transferred this includes all modifications and portions of the Software and or contained or merged into other programs YOU MAY NOT USE COPY MODIFY OR TRANSFER THE SOFTWARE FIRMWARE DOCUMENTATION OR KEY OR ANY COPY MODIFICATION OR MERGED PORTION IN WHOLE OR IN PART EXCEPT AS EXPRESSLY PROVIDED FOR IN THIS LICENSE IF YOU TRANSFER POSSESSION OF ANY COPY MODIFICATION OR MERGED PORTION OF THE SOFTWARE FIRMWARE OR DOCUMENTATION OR KEY TO ANOTHER PARTY EXCEPT AS PROVIDED IN THIS SECTION D YOUR LICENSE IS AUTOMATICALLY TERMINATED TERM This Agreement is effective upon your acceptance as set forth above and shall continue until terminated You may terminate this license at any time by destroying the Software Key and Documentation along with all copies modifications and merged portions in any form and return the Machine including Firmware to THALES or its authorized resellers It will also terminate upon conditions set forth elsewhere in this Agreement if you fail to comply with any term or condition of this Agreement You agree upon such termination to destroy the Software Documentation and Key together with all copies modifications and merged portions in any form and to return the Machine including Firmware to THALES or its authorized resellers Page 6 THALES Datacryptor Ethernet User Manual Pr
122. red Error 4 121 Minor Encrypt Clock Now in Range Encrypt clock fault cleared Hardware cleared 1270A450 005 June 2008 Page 107 Appendix Log and SNMP Trap Numbers Datacryptor Ethernet User Manual Log Type Code Trap Severity Message Information No Error 5 121 Minor Decrypt Clock Now in Range Decrypt clock fault cleared Hardware cleared Error 6 121 Minor Encrypt Clock Restarted Encrypt clock fault cleared Hardware cleared Error 7 121 Minor Decrypt Clock Restarted Decrypt clock fault cleared Hardware cleared Error 8 121 Minor Battery state is OK Battery fault cleared Hardware cleared Error 9 121 Critical Random Number Generator Hardware diagnostics cleared cleared Error 10 121 Critical Continuous Random Number Hardware Generator test cleared cleared Error Hardware 12 121 Critical Hardware Monitor reports all cleared clear Error Hardware 13 121 Critical Power Monitor reports all cleared clear Log Trap Errors Software Log Type Code Trap Severity Message Information No Error 153 Critical Trace error Software Error 2 153 Critical Exec failure Software Error 3 153 Critical System panic Software Error 4 153 Critical Internal software error Software Error 5 153 Critical Internal software error Software Error 6 153 Critical Internal software error Software Error 7 15
123. ress and if successful display the unit s Unit Name by way of confirmation as above Type a descriptive name for the connection in the edit box this will be shown in the main window below its icon 7 Click Finish or press Enter to finish adding the new connection and Datacryptor icon which will be displayed as a new icon in the main window like this Element Manager File Edit Yiew Tools Help 9 x BD Nn Datacryptor Ethernet 1 Page 30 Datacryptor Ethernet User Manual Connecting to Datacryptor Ethernet Units 8 Now double click on the new Datacryptor icon to connect to it A splash screen will be displayed whilst connecting to the unit and within a minute this should display the Front Panel Viewer for the unit an example for the 100 Mb Ethernet Datacryptor is given below It is possible to abort the connection attempt at the splash screen by pressing its Cancel button Identifying unit To quit Front Panel Viewer hit Cancel Datacryptor Network Security Systen y Copyright 1998 to 2007 all righ f C Front Panel 1 1 1 1 Unit Name 410000153R i Management Version 4 4 00 18 m a Application Version 4 00 1 Bootstrap Version 3 02 5 Datacryptor Serial Number 410000153R 10 100 Ethernet L Not loaded THALES Automatically Poll LEDs J Management View Logs Configure License Management Ready 9 You can now check the unit details at the top of the window
124. rmational Plain mode configured by peer Audit 22 722 Informational Encrypt mode configured by peer Audit 23 723 Major System startup Audit 24 724 Informational Logs cleared Audit 25 725 Informational DLCI configuration updated Audit 26 726 Informational DCLI target configuration updated Audit 27 727 Informational El timeslot configuration updated Audit 28 728 Informational T1 timeslot configuration updated Audit 29 729 Major Failed to confirm setting peer encrypt mode Audit 30 730 Major Failed to confirm setting peer plain mode Audit 31 731 Major Failed to confirm setting peer standby mode Audit 32 732 Informational Timeslot to Bundle assignment changed Audit 33 816 Minor Unknown NUA Logged Audit 34 817 Minor X 25 DTE Link Restart Audit 35 818 Minor X 25 DCE Link Restart Audit 36 819 Minor X 25 DTE Link Up Audit 37 820 Minor X 25 DCE Link Up Audit 38 821 Minor X 25 DTE Link Down Audit 39 822 Minor X 25 DCE Link Down Audit 40 823 Minor Peer NUA Added Audit 41 824 Informational Peer NUA Deleted Audit 42 825 Informational Units own NUA Set Audit 43 826 Informational Bar Unknown NUA s Audit 44 827 Informational Accept Unknown NUA s Audit 45 828 Informational Units own NUA learnt Page 124 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers
125. s In addition this operation will require you to reboot the unit for the changes to take effect Please utilize this option with caution Are you sure you want to continue SNMP Communities SNMP Version 1 and Version 2c support an access control model based upon community names An SNMP community defines a name and a set of permissions for that community name each SNMP request received by a Datacryptor unit is labeled with the originator s community name so the unit can decide whether to permit or deny the request These community strings will be utilized by the device to determine whether or not to allow SNMPv1 and SNMPv2c requests To disable SNMPv1 and SNMPv2c requests deselect the Enable SNMP tick boxes located above the communities list To add a new SNMP community 1 Select the Communities tab 2 Click the Add button the Add Community dialog is shown Add Community 1 1 1 1 Mame f Access Read Only Y 3 Enter the Name for this community 4 Select the type of Access for the members of this community Read Only Write Only or Read Write 1270A450 005 June 2008 Page 63 Element Manager Reference Datacryptor Ethernet User Manual 5 Click OK to add the community To edit an SNMP community Select the entry to edit by clicking on it and then click the Edit button Edit Community 1 1 1 1 Name The first one Access Read Only To delete an SNMP community Select the entry t
126. s Verify the IP address using the Element Manager see The IP Management tab section above Correct the IP address if necessary save the configuration and then reboot the Datacryptor The management workstation can t communicate with the Datacryptor Verify that the network connection to the management port is in place see the Connect the Cables section above Check the management interface default gateway configuration Assign a default gateway if the management workstation is on a different subnet than the Datacryptor s management port Datacryptor is not sending SNMP objects to the management workstation Ensure that SNMP traps are enabled Verify that the management workstation s IP address is configured as the SNMP trap host address See the Configuring SNMP section Page 100 Datacryptor Ethernet User Manual Appendix G Troubleshooting Cannot establish a link Check physical connectivity to ensure proper signal path If using a 1 Gig or 10 Gig Ethernet Datacryptor verify that compatible SFPs and fiber type is being used for connectivity Use the loopback mode to test the connections see The Diagnostics Tab on page 59 Traffic Flow Symptom Explanation and Possible Solutions Traffic is not being passed Verify that the Host and Network port transceivers 1 Gig and 10 Gig Ethernet Datacryptors only and the cables are properly seated Use the P
127. s the Agent Configuration tab and the Traps tab Agent Configuration Tab The Agent Configuration tab lists the SNMP communities defined for this unit and provides facilities to maintain the list SNMP Config 1 1 1 1 Agent Configuration Traps General Information SNMP Version Support iw Enable SNMP 1 Location Head Office Enable SNMPv2 Contact 44 555 350 792 Enable SNMPv3 Reset SNMP Settings Resets the SNMP system back to factory default settings SNMP 1 and SNMP v2 Communities Community Name Access The first one Read only The second one Write only The third one Read Write Page 62 THALES Datacryptor Ethernet User Manual Element Manager Reference Enter the Location and Contact information for this unit Both edit boxes accept Spaces and alphanumeric characters There is a limit of 255 characters for each field Select which versions of SNMP are to be supported using the Enable SNMP tick boxes Note Clicking on the Reset SNMP Settings button will result in a caution being shown before the factory defaults are applied see the following image Datacryptor 1 1 1 1 CAUTION This operation will remove all current SNMP 1 v2c communities and SNMP v3 VACM entries and replace them with the default entries All traps issued by this device as well as all agent requests will be utilizig the default configuration items and therefore will not conform to your current SNMP network setting
128. s used with the 1 Gig and 10 Gig Ethernet Datacryptors 10 100 Mbps auto sensing LAN port RS 232C port Electrical Mechanical 19 inch rack mount design Dimensions 100 240 VAC 10A 50 60 Hz or 48 VDC 100 Mb Ethernet unit 100M 44 mm H x 483 mm W including mounting brackets x 240 mm D including connectors 3 0 Kg 15 Watts power dissipation typical 1 Gig Ethernet unit 44 mm H x 483 mm W including mounting brackets x 388 mm D including PSU fixed connector 8 6 Kg 120 Watts power dissipation typical 10 Gig Ethernet unit 88 mm H x 483 mm W including mounting brackets x 420 mm D including PSU fixed connector 10 3 Kg 140 Watts power dissipation typical Environmental 5 to 40 degrees C 40 to 104 degrees F 10 to 90 at 25 C 77 F non condensing failing to 50 maximum at 40 C 100 F Regulatory See Appendix D Certifications Designed to FIPS 140 2 Level 3 compliance 1270A450 005 June 2008 Page 95 Appendix D Environmental amp Regulatory Datacryptor Ethernet User Manual Appendix D Environmental amp Regulatory Environmental Specifications 5 40 degrees C 40 to 104 degrees F Humidity 10 to 90 at 25 C 77 F non condensing failing to 50 maximum at 40 C 100 F 200 10 000 feet AMSL operating altitude Regulatory Safety Emissions Immunity IEC 60950 3 Edition 1999 CSA C22 2 No 60950 00 EN 60950 EN55022 1998 ANSI C63 4 1992
129. s This can be due to fan alarm heat or power failure Note that power failure is also reported separately Deprecated MIB provided for backwards compatibility only Audit 915 906 Informational Hardware Monitor reports all Deprecated MIB provided clear for backwards compatibility only Audit 916 907 Informational Power Monitor reports alarm Deprecated MIB provided for backwards compatibility only Audit 917 908 Informational Power Monitor reports all Deprecated MIB provided clear for backwards compatibility only Audit 918 910 Informational Ethernet extended configuration updated 1270A450 005 June 2008 Page 131 Appendix J Glossary of Terms Datacryptor Ethernet User Manual Appendix J Glossary of Terms Advanced Encryption Standard AES A symmetric algorithm same key for encryption and decryption using block encryption of 128 bits in size supporting key sizes of 128 192 and 256 bits Bits per Sec bps The number of bits passing a point every second the transmission rate for digital information Block cipher A type of symmetric secret key encryption algorithm that encrypts a fixed length block of plaintext at a time With a block cipher the same plaintext block always encrypts to the same ciphertext block under the same key Certificate A digital document which helps to prevent someone impersonating someone else Each certificate contains a certified public
130. s only USE OF THE DEVICE AS INITIALLY CONFIGURED IN AN OPERATIONAL ENVIRONMENT IS NOT RECOMMENDED THALES e SECURITY EXPRESSLY DISCLAIMS ANY AND ALL LIABILITY FOR DAMAGES INCLUDING BUT NOT LIMITED TO CONSEQUENTIAL DAMAGES RESULTING FROM USE OF THE UNIVERSAL CERTIFICATE OR ANY OTHER CERTIFICATE SUPPLIED BY THALES e SECURITY Prior to use in an operational environment please change the certificate authority following the procedure s described in the Key Manager section 1270A450 005 June 2008 Page 9 Preface Datacryptor Ethernet User Manual Contact Information SALES OFFICES Americas Europe Middle East Africa THALES e Security I NC THALES e Security LTD 2200 North Commerce Parkway Meadow View House Suite 200 Long Crendon Weston Florida 33326 Aylesbury U S A Buckinghamshire HP18 9EQ Tel 1 954 888 6200 England Fax 1 954 888 6211 Tel 44 0 1844 201800 Toll free within USA Fax 444 0 1844 208550 1 888 744 4976 e mail e mail emea sales Gthales esecurity com sales thalesesec com Asia Pacific THALES e Security ASI A LTD Units 2205 06 22 F Vicwood Plaza 199 Des Voeux Road Central Hong Kong Tel 4852 2815 8633 Fax 852 2815 8141 e mail asia sales thales esecurity com PRODUCT SUPPORT CENTERS Americas Europe Middle East Africa Tel 1 954 888 6277 Tel 44 0 1844 202566 Toll free within USA Fax 444 0 1844 208356 1 800 521 6261 e mail Fax 1 d 6233 emea support thal
131. se attributes is only supported through the Datacryptor Front Panel Viewer FPV application Please see the supplied MIB file for specific details RFC 2863 defines a portion of the Structure of Management Information SMIv2 The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes Please see the supplied MIB file for specific details RFC 3584 defines objects to support compatibility between SNMPv1 v2 and v3 The Datacryptor supports the majority of read write attributes in this MIB as read only in order to preserve the security of sensitive attributes Additionally we removed references to snmpTargetAddrExtTable and associated objects as they are not supported in the Datacryptor product Please see the supplied MIB file for specific details Page 104 Datacryptor Ethernet User Manual Appendix Log and SNMP Trap Numbers Appendix I Log and SNMP Trap Numbers The following table lists the log messages that may be viewed in the Datacryptor log and the corresponding SNMP trap messages that may be generated The log trap messages are listed in the Log type order Error Key followed by Audit The log number is the log number of the message when viewed in the logs by the Front Panel Viewer The Trap number is the number of the trap reported to SNMP network managers The message is the actual string seen in the log file The information
132. set provides a more secure environment than an open server room At a minimum we recommended that the unit s physical integrity be checked monthly The units also have interlock switches that will cause the key material to be erased if the lid is removed Power Supplies Failure of one of the power supply units will cause a high pitched continuous note to sound allowing a replacement to be planned Note There is only one power supply in the Datacryptor 100 Mb Ethernet and so no audible signal will be generated for power failure in that unit Lithium Battery The Datacryptor contains a lithium battery which has a typical life expectancy of 10 years dependant on usage The Datacryptor must be returned to Thales for battery replacement WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions 1270A450 005 June 2008 Page 87 Appendix B Loading Datacryptor Unit Software Datacryptor Ethernet User Manual Appendix B Loading Datacryptor Unit Software Datacryptors are factory pre loaded with the required application software and protocol data However if a new version of software needs to be loaded into a Datacryptor the following procedure describes how to carry out the operation using the Image Loader utility which will be provided with the new version of software Note The process of application upgrade can also be used to upgrade th
133. st and network interfaces Page 78 THALES Datacryptor Ethernet User Manual Element Manager Reference The Ethernet Encryption Tab Ir Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethemet Comm Ethemet Encryption Environment Expert Current Encryption Mode Standby Target Encryption Mode Standby v Peer Details Name IP Address Data Algorithm Next DEK Update Ping Peer Unit This button will ping the connected peer in order to obtain its peer information The Ethernet Encryption tab shows the Current Encryption mode in use by the unit Target Encryption mode This allows you to select the target or required encryption mode using the drop down menu The three options are Standby Encrypt or Plain Peer Details The Peer unit s details Name IP Address etc are shown on the tab Ping Peer Unit button This button may be clicked to shows additional Peer information if required 1270A450 005 June 2008 Page 79 Element Manager Reference Datacryptor Ethernet User Manual The Expert Tab The Ethernet Expert tab allows to Enable CTS Mode The Ethernet Expert tab is not shown when using the 10Gig Ethernet unit since CTS mode is always enabled for the 10Gig Ethernet unit Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethemet Comm Ethernet Encryption Environment Expert Enable CTS Mode Iv The CipherText S
134. supported by the device and the location of them Appendix Log and SNMP Trap Numbers provides a list of all the log and trap numbers together with descriptions of their purpose Appendix J Glossary defines terms used in this document Page 12 THALES Datacryptor Ethernet User Manual Overview 3 Overview The Thales Datacryptor Ethernet is a high speed high bandwidth integrated security appliance The three models provide different transfer speeds the 100 Mb Ethernet provides 100 Mbps while the 1 Gig and 10 Gig Ethernet units offer encryption at Gigabit Ethernet Layer 2 transfer rates The Datacryptor Ethernet units come in different case styles the 100 Mb Ethernet and the 1 Gig Ethernet models are housed in a single unit height 19 inch rack case for transmission speeds up to 100 Mbps and 1000 Mbps respectively while the 10 Gig Ethernet model uses a double height unit for 10 000 Mbps transmission speeds The 100 Mb Ethernet unit may have its rack mounting brackets removed so that it can be used as a desktop unit The 100 Mb Ethernet units have standard RJ45 sockets on the front panel for Host and Network connections while the 1 Gig and 10 Gig Ethernet units have two Small Form Factor sockets on the front panel these accept a range of transmit receive interfaces The 1 Gig Ethernet unit uses SFP type sockets and the 10 Gig Ethernet unit uses the XFP type sockets The host port is connected to the private network and r
135. tealing mode minimizes the latency caused by the encryption of the Ethernet packets By default this mode is enabled and disabling the mode is only recommended when connecting this unit to a legacy Ethernet Datacryptor which does not support the CTS mode The Enable CTS Mode checkbox is greyed out when the Current Encryption Mode is Encrypt The CTS mode may only be changed when in Plain or Standby mode that includes during the time that Target Encryption Mode is Encrypt but the Current Encryption Mode is still Plain or Standby Page 80 THALES Datacryptor Ethernet User Manual Element Manager Reference The Ethernet Tunneling Tab The Ethernet Tunneling tab will only be present when Tunneling mode is selected on the Ethernet Comm tab Note The Tunneling Settings section which includes the Fragmentation Size item is not displayed for the 10Gig Ethernet unit The 10Gig Ethernet unit does not support fragmentation C Properties 1 1 1 1 General Security Diagnostics IP Management RIP Ethernet Comm Ethernet Encryption Ethemet Tunneling Environment Expert MAC Settings Unit MAC Address 00 01 02 03 04 05 Peer MAC Address Filter Rules Display Filter Rules VLAN Settings VLAN ID fo Tunneling Settings Fragmentation Size 256 Help OK Cancel Apply MAC Settings Operating at the Layer 2 level the in band communications between the units will be controlled by using MAC Addresses Th
136. ter encryption mode Key 53 247 Major Receive and transmit keys Receive and transmit keys are identical are identical Key 54 254 Major No KEK algorithm loaded or Failed KEK Known Answer it is operating incorrectly Test Key 55 255 Major No DEK algorithm loaded or Failed DEK Known Answer it is operating incorrectly Test Key 56 256 Major No CA algorithm loaded or Failed CA Known Answer it is operating incorrectly Test Key 57 257 Major No common Red KEK Load valid key material between this unit and the into the units check unit peer date and time Key 58 258 Minor DEK exchange unsuccessful Key 59 259 Minor DEK exchange unsuccessful Key 60 260 Minor DEK exchange unsuccessful Key 61 261 Minor DEK exchange unsuccessful Key 62 262 Minor DEK exchange unsuccessful Key 63 263 Minor DEK exchange unsuccessful Key 64 264 Minor DEK exchange unsuccessful Key 65 265 Minor DEK exchange unsuccessful Key 66 266 Minor Failed to create DEK Key 67 267 Minor Failed to create KEK Key 68 268 Minor Failed to encode private network Key 69 269 Minor Failed to decode peer s private network Key 70 270 Major Failed to store selector Key 71 849 Major Destination selector table full Key 72 850 Major Source selector table full Key 73 851 Major Security Policy table full Key 74 271 Major Key exchange with peer denied due to ACL Key 125 81
137. to make sure that the unit is connected correctly and proceed to configure the unit 1270A450 005 June 2008 Page 31 Connecting to Datacryptor Ethernet Units Datacryptor Ethernet User Manual 10 You can login to it by using the Login button and manage it by using the View Logs Properties and License Management buttons The management facilities are described in Element Manager Reference section below To configure the unit for your network setup select the Properties button to display the unit s properties and select the appropriate tabs Note If you are going to add a number of similar Datacryptor Ethernet units the easiest method is to create a virtual unit and then use this virtual unit to configure them Direct Invocation of Front Panel Viewer It may be advantageous to start the Front Panel Viewer directly from Windows instead of going through the element manager This may be achieved by 1 Using Windows Explorer navigate to the location of the DC2k exe file create a shortcut and place on your desktop pc Shortcut to dc2k exe 3 The Element Manager Supply IP Address will be displayed 2 Click on the shortcut Supply IP Address You have not specified an IP address for the Management Application to connect to Please specify an IP address below L o Cancel Enter the IP address of the Datacryptor Ethernet unit and press Enter or OK to continue After a few seconds this should display the
138. ts sent between the two parties If the HMAC is correct it proves that it must have been added by the source Integrity Integrity assures that the content of a message has not been altered IP Internet Protocol this is the protocol that is used to transport data across the Internet Key Secret information used to decrypt or encrypt data MAC An abbreviation for Message Authentication Code a digital signature used to authenticate individual messages MAC address Media Access Control This is the hardware address of an interface card built in during manufacture Message Digest 5 A message digest algorithm that computes a secure irreversible MD 5 cryptographically strong 128 bit hash value for a document Netmask Used in combination with an IP address to define the network portion of an IP address Peer The Datacryptor device that participates in a connection Plaintext The opposite of encrypted Plaintext is an intelligible form of data such as the text on this page Private Key See Public Key Public Key A key that is available to anyone It is usually the other key toa pair which consists of a public key and a private key Public Key Algorithm An algorithm that is used in conjunction with a public key set to encrypt and decrypt data 1270A450 005 June 2008 Page 133 Appendix J Glossary of Terms Datacryptor Ethernet User Manual Public Key Cryptography In public ke
139. tton on the Front Panel Viewer the Key Manager dialog opens Ir Key Manager 1 1 1 1 Commission b xo Unit Name Unknown Change Certificates Algorithms KEKs Name Issuer Type Version 38991BC8 Universal Own Cert V1 Universal Datacryptor CA V3 Datacryptor Datacryptor CA V3 Page 46 THALES Datacryptor Ethernet User Manual Element Manager Reference 2 Click the Commission button at the top of the dialog This will start the Commissioning Wizard which begins by displaying an overview of the process as shown below Commission Datacryptor Wizard This wizard will help you commission your Datacryptor The commissioning process consists of the following steps I Installing a Certificate Authority CA 2 Install an Authenticating CA 3 Setting the Unit Name 4 Generating a Certificate Press the Next gt button to continue e ce The first item in the list will be Installing a Certificate Authority CA as shown above 3 Click the Next button to proceed to step 1 below The first page of the wizard asks if a new CA is to be installed in the unit 1270A450 005 June 2008 Page 47 Element Manager Reference Datacryptor Ethernet User Manual Step 1 Installing a new Certificate Authority CA Commission Datacryptor Wizard Do you wish to install a new Certificate Authority on to this unit This Certificate Authority will be used to authorise all secure transactions with the un
140. unit type to be verified The sequence follows this pattern All LEDs on for one second A pattern which indicates the unit type for one second All LEDs on for one second amp x rs E E E ES E o ia c w t 3 e 2 S z 5 E 2 z m 3 lt Ww a 100 Mb Ethernet X X X x 1 Gig Ethernet X E X 2 a 10 Gig Ethernet X X 2 X Where X is LED on and _ is LED off During the boot process the Datacryptor discards all traffic on its data ports If the boot process fails the Error LED illuminates and the Datacryptor generates a critical Error trap If you experience a problem during the system initialization see the troubleshooting information in Appendix G Troubleshooting Software Installation There are two software programs the firmware resident in the Datacryptor Ethernet unit and the Element manager software The firmware provides the units functionality and is pre installed The unit has the ability to upgrade with new firmware offering new features without the requirement of returning the unit to Thales Instructions on the Firmware Upgrade ability will be provided with any upgrade The Element Manager software is provided on the supplied CD ROM and must be installed as directed below Requirements The PC to be used for running the Element Manager must meet these minimum requirements e The PC must be an IBM PC or compatible that meets the m
141. using the front mounting brackets or simply placed on a rack shelf or solid surface Preparation Before installing the Datacryptor in a 19 inch rack consider the following rack mounting guidelines Ambient temperature Install the Datacryptor in an environment compatible with the 105 F 40 C maximum recommended ambient temperature Extra clearance above or below the unit on the rack is not required however be aware that equipment placed in the rack beneath the Datacryptor can add to the heat load Therefore avoid installing in an overly congested rack Air flowing to or from other equipment in the rack might interfere with the normal flow of cooling air through the Datacryptor increasing the potential for overheating 1270A450 005 June 2008 Page 19 Installation Datacryptor Ethernet User Manual Airflow Make sure that there is sufficient flow of air around the Datacryptor so that safe operation is not compromised Maintain a clearance of at least 3 inches 7 62 cm at the sides of the Datacryptor to ensure adequate air intake and exhaust If installing in an enclosed rack make sure the rack has adequate ventilation or an exhaust fan An enclosed rack with a ventilation system that is too powerful can prevent proper cooling by creating negative air pressure around the Datacryptor Mechanical Loading Keep the center of gravity in the rack as low as possible This ensures that the weight of the Datacryptor will not make the r
142. working Connect Dial Up Networking menu option J Help Index Help Index menu option Visibility of the Toolbar is controlled by the View gt Toolbar menu option Datacryptor Icons Each Datacryptor icon in the main window represents a real or virtual Datacryptor unit e Grey means a Datacryptor unit that is not connected e Blue means a Datacryptor unit that is connected e White means a virtual Datacryptor used as a template to add similar units Page 36 THALES Datacryptor Ethernet User Manual Element Manager Reference To connect to a Datacryptor unit 1 Double click its icon 2 Once the connection has been made the Front Panel Viewer will be displayed showing information read from the unit This dialog provides access to all the Datacryptor unit management facilities described throughout this guide 3 To disconnect from the Datacryptor unit click the Close button in its Front Panel Viewer To delete a Datacryptor unit from the system select its icon and press Del or select the File Delete Unit menu option or click on the Delete button on the Toolbar This displays a confirmation dialog first To change an icon s description IP address or connection method 1 Select the icon and select the Edit Edit Unit menu option or press F2 This displays the Edit Unit dialog Edit Unit Descriptive name Datacryptor 1 IP Address 2 2 2 2 Yia Network v so _ toe 2 Edit the name IP address or conn
143. y cryptography different keys are used for encryption and decryption The public key is public but the private key is known only to its owner Anyone that possesses the public key can encrypt a message so that only a single recipient the owner of the private key can decrypt it The two parties do not need to share any secret information Public Key Data Consists of a public key algorithm a public key and a private key Public Key encryption The process of encrypting data using public key data Public Key Set A pair of keys a public key and a private key Replay Prevention Prevents the replaying of a message or part of a message to produce an unauthorized effect such as the capture and replay a sequence of authentication messages to masquerade as a legitimate user Secret Key The key used in symmetric encryption Both participants must share the same key and this key must remain secret to protect the communication Secure Hash Algorithm SHA A US standard for a cryptographically strong hash algorithm designed by the National Security Agency and defined by the National Institute of Standards and Technology NIST SFP The Small Form Factor Pluggable device is a compact transceiver used in data communication applications where fiber optic or twisted pair networking cable is to be employed SNMP Simple Network Management Protocol is an Internet standard used to allow monitoring of per

Download Pdf Manuals

image

Related Search

Related Contents

MPS 409 Setup Guide - Extron Electronics  SMART CUT 2 - Locations et prestations pour l`audiovisuel  取扱説明書  Sun 10-Gigabit Ethernet PCI-X Adapter Installation and Userճ Guide    KOG5-3シリーズ - Promano Gripper  Manuel d`utilisation  LFC23760 - Appliance Factory Parts  GE JT5000DFWW Use and Care Manual  Instrucciones de operación PT-VX500U PT  

Copyright © All rights reserved.
Failed to retrieve file