Home
AMX Wall Mount Decor IR Sensor IRX-DM+ User's Manual
Contents
1. 200 feet 60 96 m Connections and Wiring Wiring the IRX DM or IRX SM to the AMX IR Receiver Wire the IR sensor to the AMX IR receiver as shown in FIG 4 IRX SM 2 Top view or D 442 voc IRX DM 2 AUX OUT OUT GND To the external sensor input connector _ _ Top view GND D 12 VDC IN AUX OUT AUX OUT PWR GND IRX SM 1 Top view or IRX DM 1 FIG 4 Wiring the IR sensor You can wire up to eight IR sensors in parallel to an AXC RCVI AMX Television Manager MX8 MX16 or NI 700 For additional information refer to the reference guides or instruction manuals for those AMX products Checking IR Data Status Locate the red IR Data LED on the front of the unit Point the system s AMX transmitter towards the sensor and press a button The IR Data LED lights when the unit receives data If the IR Data LED on the unit does not light e Verify that the transmit LED on the transmitter lights when you press a button e Check the wiring to the unit e Verify that the transmitter frequency is properly configured Mounting the IRX DM 1 For wall or podium mounting FIG 5 AMX recommends mounting the IRX DM in a standard 1 gang wallbox with a minimum internal clear ance of 1 3 4 W x 2 5 8 H x 1 5 8 D Gently remove the bezel from the wallplate Place the panel in the wallbox and align the screw holes with the mounting holes on the panel Turn the unit over and locate the Phoeni
2. BPD IT S YOUR WORLD TAKE CONTROL Overview The IRX DM FIG 1 is a remote IR sensor that works with the Axcess AXC RCVI card AMX Television Managers and MX8 MX16 Relay Receivers to remotely control IR devices The IRX DM FG458 10 11 is ina UniMount enclosure that fits into most US style single gang enclosures The IRX DM works with AMX 38 kHz or 455 kHz IR transmitters Note The IRX SM swivel mount version is also available for wall or ceiling installations ___ R Sensor Sf IR Data LED T NL FIG 1 IRX DM unimount IR sensor IRX DM Specifications 4 68 x 2 93 x 1 14 118 70 mm x 74 40 mm x 29 00 mm 0 30 7 70 mm depth from wall surface Dimensions HWD Available Colors White FG458 10 and Black FG458 11 Receive Frequencies 38 455 kHz user selectable Mounting Mounts into most US style single gang enclosures Weight 6 8 oz 190 4 grams 25 mA Power Consumption Wiring and Installation Set the receive frequency device number and IR validation level before installing the sensor FIG 2 illustrates the location of key components on the IRX DM circuit board a BY 4 pin Phoenix PS Aara Connector P Set Jumper JP1 to Position 1 2 for 38 kHz Position 2 3 for 455 kHz q Receive Frequency Jumper Pin JP1 FIG 2 Location of key components on the IRX DM circuit board Setting the Receive Frequency Use the jumper pin on the corner of the circuit bo
3. ard to set the receive frequency FIG 3 illustrates the configuration of the jumper 38 kHz KE Pin 1 1 ke Pin 2 3 ae Pin3 FIG 3 Receive frequency jumper settings 455 kHz Quick Start Guide IRX DM waltMount Remote IR Sensor Note The unit will not operate until JP1 is configured for either 38 kHz or 455 kHz e To receive 38 kHz position the JP1 jumper on pins 1 and 2 closer to the Phoenix connector e To receive 455 kHz default setting position the JP1 jumper on pins 2 and 3 away from the Phoenix connector Wiring the IR Sensors The IRX DM uses a 4 pin Phoenix connector for power and data If the distance between the receiver and Central Controller exceeds power consumption limits you can connect a local 12 VDC power supply to the Phoenix connector Preparing captive wires You will need a wire stripper and a flat blade screwdriver to prepare the captive wires 1 Strip 0 25 inch 6 35 mm of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams in this section 3 Turn the flat head screws clockwise to secure the wire in the connector Note Do not over torque the screw Doing so can bend the seating pin Wiring Guidelines The IRX DM requires 12 VDC power to operate properly The power is supplied by the AMX system s connection cable The maximum wiring distance between the Central Controller and the receiver is
4. x connector Fasten the panel to the wallbox using the screws supplied with the panel Snap the wallplate back on the bezel bezel wall plate FIG 5 IRX DM Mounting Dimensions AMX Corporation reserves the right to alter specifications without notice at any time For full warranty information refer to the AMX Instruction Manual s associated with your Product s 042 004 2749 11 04 2004 AMX Corporation All rights reserved The AMX logo is a trademark of AMX Corporation AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 e 800 222 0193 fax 469 624 7153 technical support 800 932 6993 e www amx com 93 0458 10 REV B Amar 7
Download Pdf Manuals
Related Search
Related Contents
Projet owners manual ST-NVR4CH ST-NVR8CH ST-NVR16CH USER`S MANUAL Garmin Forerunner® 910XT, le summum de l`expérience sportive User`s Manual TRATAMIENTO DE LOS CONDILOMAS DURANTE LA GESTACIóN Sony VPL-PX10 User's Manual Garmin affordable car navigation GPS Receiver User Manual Haier slim3 User's Manual Copyright © All rights reserved.
Failed to retrieve file