Contents

1. power supply e Operating Environment 10 C 50 F to 35 C 95 F e Storage Temperature 20 C 4 F to 60 C 140 F NXT BP Features e Battery Usage 4 to 8 hours time is usage dependent e Charge Capacity 6300mAh e Operating Environment 10 C 50 F to 35 C 95 F e Storage Discharge Temperature 20 C 4 F to 60 C 140 F e NXT CHG Kit FG2250 50kK 1 charger FG2250 50 and 2 NXT BP batteries FG2255 10 e NXT BP batteries FG2255 10 e NXT CHG charger FG2250 50 Optional Accessories ATTENTION Before beginning the installation of the battery base to a CV series touch panel NXDT CV7 CV10 or CV17 verify that the firmware on the panel is Build 27 or higher This build incorporates the necessary updates for using the Modero with the NXA BASE B This does not apply to other Modero touch panels Refer to the touch panel s instruction manual for detailed firmware update procedures Installing the NXT BASE B to an NXT Modero Panel 1 Power Off the panel before attempting to use the NXA BASE B 2 Place the empty battery base onto a flat level surface 3 Verify the alignment of the Panel Interface connectors between the panel male connector and base female connector FIG 2 Installation Guide NXA BASE B Battery Base and Accessories Captive fasteners secure base to panel Battery Compartment pulls outwards ps Back Front Alignment pegs Pan
2. an F For more detailed installation and operating instructions refer to the touch panel s instruction manual available on line at www amx com mocdero Te NXT BP Modero Power Pack NXA BASE B Battery Base FIG 1 NXA BASE B and NXT BP Overview of the NXA BASE B The NXA BASE B Battery Base is a Modero accessory that allows a touch panel to function off the collective charge of two internally connected NXT BP batteries FG2255 10 The base provides both power and battery information to the panel via the panel interface connector FIG 2 This base is also sold as part of an NXA BASE B Kit FG2255K that contains one 1 battery base and two 2 batteries The accompanying batteries can be charged through either the base or optional NXT CHG Modero Power Station FG2250 50 Refer to the 12 and 15 Modero Touch Panel Series Owner Reference Manual for more information Specifications Specifications Dimensions HWD NXA BASE B FG2255 NXT BP FG2255 10 e 1 13 x 8 63 x 11 81 2 86 cm x 21 91 cm x 30 00 cm e 0 69 x 3 50 x 5 81 1 75 cm x 8 89 cm x 14 76 cm e NXA BASE B 2 7 A 12 VDC max power draw while charging e NXT BP Voltage 11 1 Volts Weight e Base unit 1 25 Ibs 0 567 kg e Base and 2 batteries 3 23 Ibs 1 47 kg NXA BASE B e Charge current 2 5A 12 VDC Features e Charge time for two depleted batteries 5 8 hours e The Modero unit plus battery base requires a PSN6 5
3. anel using the Full Clean Download to Panel feature in TPD4 Refer to the manual for more detailed information This step updates the Setup pages more specifically the Battery Base page on your Modero panel 7 Press and hold the Front Setup Access button FIG 7 for 3 seconds to access the on screen Setup page simulated image Front Setup Access button FIG 7 NXA BASE B and Modero panel combo 8 Press the on screen Protected Setup button and press the on screen Reboot button to restart the panel and incorporate the new changes 9 After startup repeat step 7 to access the Setup page 10 Press the on screen BATTERY BASE button to access the Battery Base page This page allows you to both confirm communication between the two units panel and battery base and the charging discharging status of the batteries within the battery base Charging the NXT BPs using the NXA BASE B 1 Insert the two 2 batteries into the battery compartment shown in FIG 6 2 Insert a 2 pin connector from a PSN6 5 power supply to the rear PWR connector on the NXT Modero panel 93 2255 REV E 2008 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com Aa R
4. el Interface connector female FIG 2 NXA BASE B showing Panel Interface and connector locations 4 Carefully place the Modero panel over the base alignment pegs FIG 3 These pegs assist in aligning the panel to the base Top view Bottom view Interface connector Panel Interface connector female Alignment pegs Captive fasteners FIG 3 NXA BASE B shown aligning with NXT panel 5 Gently apply downward pressure until the panel is securely mounted to the battery base 6 Firmly grip both the panel from side and battery base from below ATTENTION The battery base CANNOT be hot swapped A panel receiving power through a connected PSN6 5 cannot have a Panel Interface connector from the battery base inserted into the bottom of the panel POWER OFF the panel before installing the NXA BASE B 7 Gently place the touch panel LCD facedown onto a soft cloth This prevents scratching of the LCD while the battery base is secured 8 Locate the captive fastners on the underside of the battery base FIG 4 by angling the base combo slightly forwards 9 Push down on each fastener head by using a flat head screwdriver to turn them clockwise until the NXA BASE B is securely attached to the underside of the NXT Modero touch panel 10 After securing is complete firmly grip both the panel LCD base combo and gently place the unit back onto a flat surface Captive fasteners secure base to pane
5. l FIG 4 NXT BASE B showing underside fastener locations Checking the NXT BP Charge 1 Press the Battery Life Indicator button FIG 5 once to illuminate the Battery Life LEDs and display the percent charge remaining on the battery this indication lasts for a few seconds moclero Battery Life Charge POWER PACK Battery Life Indicator button It s recommended to fully charge the batteries before their initial use FIG 5 NXT BP Modero Power Pack showing Battery Life Indicator and button 2 Repeat the above step for the remaining NXT BP battery 3 Charge the batteries by inserting them within the battery base It is recommended to fully charge the batteries before they are initially inserted into the base Refer to the following section for more detailed information on this process ATTENTION If the 25 LED indicator is blinking this indicates that the battery has less than 5 of a charge remaining Installation of an NXT BP into the NXA BASE B The base does not directly connect to a power supply but rather receives the power necessary to charge the batteries from the Modero panel through the Panel Interface connector 1 With the panel atop the base open the battery compartment FIG 6 by pulling the handle outwards This compartment is capable of housing two 2 NXT BP batteries NXT BP Battery 2 Battery Connectors Interface connector Battery Connector Port Battery Com
6. partment NXT BP Battery 1 FIG 6 Battery installation procedure 2 Install the NXT BP battery with the label side facing down For full warranty information refer to the AMX Instruction Manual s associated with your Product s 12 08 3 Align the battery connectors with their corresponding battery connector ports located on the battery slot inside the battery compartment FIG 6 4 Insert the NXT BP battery until the connectors securely fit into the battery connector port within the slot 5 Repeat steps 3 and 4 for the remaining battery 6 Apply a small amount of pressure to close the battery compartment until the compartment latches ATTENTION The AMX logo will appear to indicate that the panel is receiving power Updating Firmware and Setup pages 1 Download the latest Modero firmware from the AMX com website 2 Update the latest firmware to the Modero panel Refer to the instruction manual for detailed download and update instructions NOTE With older panels such as the NXDT CV7 CV10 or CV17 touch panels the Modero firmware must be Build 27 or higher 3 Download the TPDesign4 setup patch from the AMX com website to update the current release of TPD4 for use with the NXA BASE B 4 Launch the patch TPD4 Patch EXE to update your TPD4 program 5 After rebooting your machine create a new TPD4 project that consists of a single blank NXT Modero touch panel page and button 6 Download this page to the p