1. 5 1 A 12 VDC stand alone Minimum power e CV12 requires a PSN4 4 Power Supply FG423 45 supply required using accessories can increase the power draw requirements e CV15 requires a PSN6 5 Power Supply FG423 41 using accessories can increase the power draw requirements e 64 MB SDRAM upgradable to 256 MB e 64 MB Compact Flash upgradable to 1 GB factory programmed e 12 94 x 14 95 x 11 73 32 87 cm x 37 97 cm x 29 78 cm Fully lowered height 7 45 18 92 cm e Decor faceplate included 14 37 x 15 20 x 3 31 36 50 cm x 38 61 cm x 8 40 cm e Conduit wallbox 13 48 x 14 18 x 3 49 34 24 cm x 36 00 cm x 8 85 cm optional e 10 91 x 12 34 x 12 50 27 70 cm x 31 33 cm x 31 75 cm Fully lowered height 6 77 17 20 cm e Decor faceplate included 12 38 x 12 59 x 3 25 31 43 cm x 31 97 cm x 8 25 cm e Conduit wallbox 11 52 x 11 60 x 3 50 29 27 cm x 29 47 cm x 8 89 cm optional Memory Resolutions e 12 panels 800 x 600 pixels e 15 panels 1024 x 768 pixels Front Panel e Light Sensor Photosensitive light detector for automatic adjustment of the panel brightness e Motion Sensor PIR Proximity Infrared Detector to wake the panel when panel is approached e Sleep Button Pushbutton grey used to either put the panel into a sleep or wake state e Microphone Used for intercom applications e Speakers Frequency response 450 Hz 7 KHz Rear Connectors e PCMCIA Card Slot Provides
2. AMX logo is a trademark of AMX Corporation AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com REV H
3. Breakout Box Supported Audio Sample Rates Included Accessories Optional Accessories Composite S Video Luma S Video Chroma ICSNet to panel Power In front Audio Video Power to panel to panel In Mic Out ICSNet In FIG 2 Connector layouts on the NXA AVB Breakout Box included Connections and Wiring FIG 3 shows the layout of the connectors located on the rear of the base on the NXT and on the left side panel of the NXD panels Audio Video from NXA AVB CAT5 Ethernet CAT5 ICSNet CATS N A ct TO t 4 i i i AUDIO ETHERNET ICSNet PWR VIDEO 10 100 F PCMCIA Cardbus slot Power Stereo Output FIG 3 Connector layout on the CV Touch Panels Power Connection A PSN4 4 or PSN6 5 Power Supply can indirectly supply power to the Modero panels via the NXA AVB Breakout Box FIG 4 shows a sample wiring configuration using both an indirect or direct PSN power connection for a CV Modero Panel ICSNet In Mic Out Line Level out RJ 45 4 pin captive wire to amplifier PSN power Video In Audio In VOL card supply BNC 6 pin captive wire t y front NXA AVB PSN4 4 PSN6 5 r supplied via rear ii ICSNet Ethernet CAT5 CAT5 Audio Video PSN power CAT5 supply 4 Direct Connect NXD T CV12 15 Touch Panels FIG 4 Sample Wiri
4. wireless connectivity with upgrade e Stereo Ouput Connector Stereo output through a 3 5mm mini jack for use with external speakers or headphones e Audio Video Connector RJ 45 connection for A V signals between the NXA AVB Breakout Box and the panel e Ethernet 10 100 Port RJ 45 port for 10 100 Mbps communication e ICSNet Connector RJ 45 connection for ICSNet interface Quick Start Guide 12 and 15 Modero Color Video Touch Panels Firmware version G4 Modero CV Specifications Cont Operating Storage Environments e Operating Temperature 10 C 50 F to 40 C 104 F e Operating Humidity 20 85 RH e Storage Temperature 20 C 4 F to 60 C 140 F e Storage Humidity 5 85 RH NXA AVB A V Breakout Box FG2254 01 FIG 2 e Included accessory with CV12 and CV15 panels e Provides video audio distribution to the A V panel over CAT5 cable up to 200 60 96 m and accepts either Composite or S Video e 48000HZz 44100Hz 32000Hz 24000HZz 22050Hz 16000Hz 12000Hz 11025Hz and 8000Hz e Installation Kit for 12 15 panels KA2250 02 One 2 pin mini Phoenix connector 41 5025 and Three Phillips head screws 4 20 x 0 250 Black 80 0114 08 e Modero Table Top Cable CA2250 50 provided with all NXT panels e CB TP12 Conduit Wallbox FG031 10 e CB TP15 Conduit Wallbox FG032 10 e MB TP12 Universal VESA Mounting Box FG031 50 One strain relief grommet 45 0004 03 One b
5. APIA IT S FOUR WORLD TAKE CONTROL For more detailed installation configuration programming file transfer and operating instructions refer to the 72 and 15 Modero Touch Panel Series Instruction Manual available on line at www amx com NXD panel f Wall Mount NXT panel Table Top FIG 1 Sample Wall Mount and Table Top CV Touch Panels ATTENTION Verify you are using the latest NetLinx Master Firmware available from www amx com on your ME260 64 and NI Series Controllers Verity the TPDesign4 program being used is Version 2 4 or higher Overview The 12 NXT NXD CV12 and 15 NXT NXD CV15 Video panels are 4th generation graphics touch panels that provide richer colors and crisper contrast than any panels currently on the market Modero tilt panels now come with an optional NXA BASE B battery base that allows it to function off the collective charge of two internal NXT BP batteries that can be charged either in the base or in an optional NXT CHG charger Specifications Modero CV Specifications Dimensions HWD NXT CV15 FG2252 11 NXD CV15 FG2253 12 CB TP15 FG032 10 Dimensions HWD NXT CV12 FG2250 11 NXD CV12 FG2251 12 CB TP12 FG031 10 Power Requirements Constant current draw 2 04 A 12 VDC stand alone CV12 e Startup current draw 3 0 A 12 VDC stand alone Power Requirements Constant current draw 3 45 A 12 VDC stand alone CV15 e Startup current draw
6. e System Connection button to open the System Connection page FIG 6 Setting up the System Connection Parameters There are two choices for communication with the system Master Ethernet or ICSNet The default method used for Master connection is Ethernet First Setup the Master Connection To configure Ethernet communication 1 Under the Master Connection column toggle the CSNET Ethernet field until the choices cycle to Ethernet 2 Press the Mode button e URL In this mode enter the System Number zero for an unknown System Number and the IP URL of the Master Master Port Number is defaulted to 1319 AMX Corporation reserves the right to alter specifications without notice at any time System Connection iP Settings gt g MEGS r Sani Master s connection information Panel s connection information FIG 6 Sample System Connection page e Listen In this mode add the Modero s IP Address into the URL List of the Master using NetLinx Studio This mode sets the Modero panel to listen for broadcasts from the Master using the panel IP from its URL list e Auto In this mode enter the System Number of the NetLinx Master This mode instructs the Modero to search for a Master that uses the same System Number assigned within the Master Connection section and that resides on the same Subnet To configure ICSNet Communication 1 Under the Master Connection column toggle the CSNET Ethernet fie
7. lack metallic VESA back box 62 0031 50 One black plastic cover with grommet opening 60 0031 50 Four Phillips pan head screws 8 32 x 0 50 Black 80 0146 02 Twelve Phillips head screws 6 32 x 0 500 Black 80 0139 e MB TP15 Universal VESA Mounting Box FG032 50 One strain relief grommet 45 0004 03 One black metallic VESA back box 62 0032 50 One black plastic cover with grommet opening 60 0032 50 Four Phillips pan head screws 8 32 x 0 50 Black 80 0146 02 Twelve Phillips head screws 6 32 x 0 500 Black 80 0139 e NXA BASE B Battery Base Kit FG2255K 1 battery base FG2255 and 2 NXT BP batteries FG2255 10 e NXA RK12 Rackmount kit for 12 Wall Mount panels FG2904 50 e NXA RK15 Rackmount kit for 15 Wall Mount panels FG2904 51 e NXA WC8021 1b 802 11B Wireless Card FG2255 02 e NXT CHG Kit FG2250 50K 1 charger FG2250 50 and 2 NXT BP batteries FG2255 10 e PSN4 4 Power Supply 12 VDC FG423 45 e PSN6 5 Power Supply 12 VDC FG423 41 e Upgrade SDRAM memory NXA EXM128M 128 MB memory card FG079 01 NXA EXM256M 256 MB memory card FG079 02 e Upgrade Compact Flash factory programmed with firmware NXA CFTP128M 128 MB compact flash card FG2116 22 NXA CFTP256M 256 MB compact flash card FG2116 23 NXA CFTP512M 512 MB compact flash card FG2116 24 NXA CFTP1GB 1 GB compact flash card FG2116 25 NXA AVB A V Breakout Box FIG 2 shows the front and rear connectors on the
8. ld until the choices cycle to ICSNET 2 All other settings are disabled and do not apply Second Setup the IP Settings Panel Communication Toggle the on screen DHCP Static field to select the appropriate setting for your system e DHCP With this setting other settings are greyed out and do not apply Typically the Host Name can be left blank These fields pulled from the Ethernet connection are filled in by the panel after the unit is rebooted e Static IP With this setting you must enter the network information as provided by your Network Administrator Remaining System Connection Parameters 1 Set the speed of the Ethernet connection to the panel by selecting from either Auto default 10 Half Duplex 10 Full Duplex 100 Half Duplex or 100 Full Duplex 2 Enter a valid username and or password if the target Master is secured 3 Press the Back button and then press the on screen Reboot button to save the changes and cycle power NOTE Press the on screen Reboot button after any changes are made to the touch panel s Communication Parameters Setting up a Modero Wireless Connection Refer to the 72 and 15 Modero Touch Panel Series Instruction Manual for detailed wireless connectivity setup and configuration information 93 2252 For full warranty information refer to the AMX Instruction Manual s associated with your Product s 036 004 2682 4 05 2005 AMX Corporation All rights reserved The
9. ng configuration on CV Modero Panels RJ 45 Connections Use a standard CAT5 Ethernet cable to provide communication between the touch panel NXA AVB and the NetLinx Master Ethernet 10 100 Base T Connector The Ethernet cable connected to the rear of the Table Top Panels or to the side of the Wall Panel provides 10 100 network connectivity between the panel and the NetLinx Master A Activity LED yellow blinks when receiving Ethernet data packets L Link LED green blinks when the Ethernet cables are connected and terminated correctly FIG 5 Layout of Ethernet LEDs Modero Setup and System Connection 1 Carefully remove the panel from the shipping box peel the protective plastic cover from the LCD and apply power to the panel 2 From below the LCD press the grey Front Setup Access button for 6 seconds passing over the Setup page to access the Calibration setup page and follow the on screen instructions 3 Press the grey Firmware Setup Access button for 3 seconds to open the Setup page and touch the on screen Protected Setup button 4 Enter the panel password into the keypad Factory default is 1988 5 Press the Device Number field to open the on screen Device Number keypad and enter a value for the panel default is 10007 6 Press Done when finished and press the on screen Reboot button to cycle power to the panel 7 Repeat step 3 to access the Protected Setup page and touch th
Download Pdf Manuals
Related Search
Related Contents
Hybrid Manual - Reface Industries User Manual 分別45ℓダストボックス ハイタイプ 組立・取扱説明書 tion est expressément fabriqué pour sa récupération en tant que Recruter sans se tromper - Stéphane Haefliger Sociologue Guide d'utilisation User's guide Manual de instrucciones 取扱説明書 LG Electronics 50PY2DR Flat Panel Television User Manual Presto EverSharp POUR - TobecOnline Copyright © All rights reserved.