AMX AXD-IR+ User's Manual

image

Contents

1. eno 1 F 1 GND AXlink connector ayy 2C E 2 AxM _ Central on the AXD IR Axp 3 L F 3 AXP Controller Pwr 4C 14 O APNR FIG 7 AxXlink wiring with an external 12 VDC power supply Note Do not connect the PWR wire to the AXlink connector s PWR terminal on the Central Controller s side AMX Corporation reserves the right to alter specifications without notice at any time Checking IR Data Status Locate the red IR Data LED on the front of the unit Point the system s AMX transmitter towards the sensor and press a button The IR Data LED lights when the unit receives data If the IR Data LED on the unit does not light e Verify that the transmit LED on the transmitter lights when you press a button e Check the wiring to the unit e Verify that the transmitter frequency is properly configured Checking AXlink Status The AXlink LED lights to indicate AXlink power data status as follows e 1 blink per second Indicates power is active and AXlink communication is working Indicates the devices specified in the Master program do not match the devices found e 2 blinks per second e 3 blinks per second Indicates AXlink communication error Indicates the following conditions e There is no AXlink control or activity but power is On e The Axcess program is not loaded e Full On If the LED is on and not flashing disconnect the AXlink connector and
2. recheck all AXlink connections Then reconnect the AXlink connector to the panel and verify the LED is flashing once per second Mounting the AXD IR 1 For wall or podium mounting FIG 8 AMX recommends mounting the AXD IR in a standard 1 gang wallbox with a minimum internal clearance of 1 3 4 W x 2 5 8 H x 1 5 8 D 2 Gently remove the bezel from the wallplate 3 Place the panel in the wallbox and align the screw holes with the mounting holes on the panel 4 Turn the unit over and locate the AXlink connector a Connect the unit to AXlink data power bus b Check the AXlink LED should blink once per second 5 Fasten the panel to the wallbox using the screws supplied with the panel 6 Snap the wallplate back on the bezel 2 93 74 4 MM REF 1 80 45 72 MM i 1 14 i 29 0 mm MAX DEPTH 50 7 7 mm FROM WALI 3 281 83 34 MM ma 4 68 118 87 MM REF z 2 80 71 12 MM L_J A 125 R CUTOU 3 175 MM MAX E Install unit using supplied 6 32 machine screws at these locations FIG 8 AXD IR Mounting Dimensions A bezel wall plate For full warranty information refer to the AMX Instruction Manual s associated with your Product s 042 004 2747 6 05 2005 AMX Corporation All rights reserved The AMX logo is a
3. other set of pins configured for 455 kHz e To receive 455 kHz default setting position both jumpers on pins 1 and 2 away from the edge of the circuit boards e To receive 38 kHz position both jumpers on pins 2 and 3 near the edge of the circuit boards Setting the AXlink Device Number 1 Locate the 8 position Device DIP switch FIG 2 2 Set the DIP switch according to the DIP switch values shown below Switch 12345 6 7 8 Value 1 2 4 8 16 32 64 128 The device number is set by the total value of DIP switch positions that are ON down The Axcess software program in your system typically uses device numbers 128 through 255 for the panels As an example the DIP switch in FIG 4 defines device number 129 1 128 129 Device Number ha HAH a inane FIG 4 Example Device DIP Switch set to 129 Note If you later change the device number remove and reconnect the AXlink connector to enter the new device number into memory Sensor IR Validation Level The IR validation level is set on the receiving device such as an AXC RCVI Setting the IR Validation Level An IR transmitter must send repetitions of data for the receiver to accept it as valid data In some installations a light wall color or other physical condition may interfere with the sensor s or receiver s ability to sense the transmitted signal The signal may reflect or bounce and become distorted The receivers can be set to use either two or th
4. trademark of AMX Corporation AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0913 fax 469 624 7153 technical support 800 932 6993 e www amx com 93 0456 10 REV B AMDA Lr
5. AXlink cable The maximum wiring distance between the Central Controller and the receiver is determined by power consumption supplied voltage and the wire gauge used for the cable The following table lists wire sizes and the maximum lengths allowable between the receiver and the Central Controller The maximum wiring lengths are based on a minimum of 13 5 volts available at the Central Controller s power supply Wiring Specifications 35 mA Maximum Wiring Length If you install the unit farther from the Central Controller than recommended in this table connect an external 12 VDC power supply as shown in the following wiring diagrams Connection and Wiring Wiring the AXD IR or the AXR IRSM to AXlink Install the AXlink data power bus wiring as shown in FIG 6 end ILF 1 GND AXlink connector axm 2C R 2 axm_ Central on the AXD IR axp 3 E A or 3 AXP Controller PWR 4 _ H A 4 PWR FIG 6 AXlink wiring Using the AXlink Connector with an External 12 VDC Power Supply Use a 12 VDC power supply when the distance between the Central Controller and the sensors or receivers exceeds the limits described in the Wiring Specifications table above Make sure to connect only the GND wire on the AXlink connector when using a 12 VDC power supply FIG 7 PWR 12 VDC Power a Supply
6. Baa are IT S YOUR WORLD TAKE CONTROL Overview The AXD IR FIG 1 is a remote IR receiver for use with both AMX Axcess NetLinx Central Controllers and operates via the AXlink bus to remotely control AXlink devices The AXD IR is in a UniMount wall panel that fits into most US style single gang enclosures The AXD IR works with AMX 38 kHz or 455 kHz IR transmitters Note The AXR IRSM swivel mount version is also available for wall or ceiling installations FIG 1 AXD IR UniMount IR receiver AXD IR Specifications Wiring and Installation Set the receive frequency AXlink device number and IR validation level before installing the AXD IR FIG 2 illustrates the location of key components on the AXD IR circuit board IR Validation Jumper Pins 8 position AXlink Device Axlink DIP Switch aos Connector _ lt lt Y gt pK a a Le a gt Receive Frequency Jumper Pins FIG 2 Location of key components on the AXD IR circuit board Setting the Receive Frequency Use the set of jumper pins on the corner of the circuit board to set the receive frequency FIG 3 illustrates the configuration of the jumpers IR SNSR IR SNSR iM 38 455 E A 38455 kHz kHz Setting for 38 kHz Setting for 455 kHz FIG 3 Receive frequency jumper settings Quick Start Guide AXD IR WallMount Remote IR Receiver Note The unit will not operate with one set of pins configured for 38 kHz and the
7. ree repetitions of sequential signals to validate and accept the signal data Perform the following steps to set the receiver s IR level 1 Locate the IR jumper pins J1 FIG 5 on the circuit board FIG 2 2 3 2 3 a amp Jf Ji Setting for 2 validations Setting for 3 validations FIG 5 IR validation jumper pin settings 2 Position the IR validation jumper FIG 5 to select the number of valid IR data repetitions to be accepted e Position the jumper at 2 to have the unit validate 2 sequential signals e Position the jumper at 3 to have the unit validate 3 sequential signals Wiring the IR Sensors and Receivers The AXD IR uses a 4 pin AXlink connector for power and data If the distance between the receiver and Central Controller exceeds power consumption limits you can connect a local 12 VDC power supply to the AXlink connector Preparing Captive Wires You will need a wire stripper and a flat blade screwdriver to prepare the Captive wires 1 Strip 0 25 inch 6 35 mm of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams in this section 3 Turn the flat head screws clockwise to secure the wire in the connector Note Do not over torque the screw Doing so can bend the seating pin Wiring Guidelines The AXD IR requires 12 VDC power to operate properly The power is supplied by the AMX system s