Home
Amtrol RP-15HP User's Manual
Contents
1. WATER PRESSURE BOOSTER SYSTEM AMTROL PRESSURISER WITH GUARDIAN CP CONTROL INSTALLATION amp OPERATION INSTRUCTIONS AMTROL PRESSURISER PRESSURISER Models RP 10HP RP 15HP and RP 25HP NOTE Inspect for shipping damage Notify freight carrier or store where purchased immediately if damage is present To avoid risk of personal injury and property damage if the product appears to be malfunctioning or shows signs of corrosion call a qualified professional immediately Current copies of the product manual can be viewed at www amtrol com Use proper safety equipment when installing HAZARDS OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL A THIS IS THE SAFETY ALERT SYMBOL IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER INJURY AS WELL AS PROPERTY DAMAGE A WARNING USE ONLY WITH POTABLE WATER SYSTEMS Do not operate in a setting with freezing temperatures or where the temperature can exceed 200 F and do not exceed the maximum working pressure specified for this Product READ CAREFULLY THE PRODUCT WARNING INSTALLATION amp OPERATION INSTRUCTIONS FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS MAY RESULT IN SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS IN THE ABSENCE OF SUCH CODES FOLLOW THE CURRENT EDITI
2. When number appears tap or to change cut in setting 3 Press m again When HI appears tap or to change cut out setting This will determine the pressure at which the pump shuts off 4 Press a third time The last Error Code in memory will display see Error Code table in Troubleshooting section If no errors have occurred the display will show 5 After approximately 10 seconds Pr will appear indicating the settings are programmed Display will then revert to the line pressure NOTE The settings will now be stored until changed manually even in the event of power failure NOTE If pump cannot reach cut out setting within 5 minutes with no water running lower the pressure settings to fall within the pump s pressure capabilities Operation ENSURE THE SWITCH IS OPERATING PROPERLY AFTER MAKING ANY ADJUSTMENTS OBSERVE AT LEAST ONE PUMP CYCLE TO VERIFY PROPER PUMP SHUT OFF Please contact AMTROL Technical Support at 401 535 1216 or an AMTROL representative if further assistance is required Winterizing To drain disconnect the pump from power and open a faucet to bleed off water pressure Lay the tank on its side to disconnect the piping between the pump and tank to completely drain the unit Ensure exposed piping conected to unit is also drained NOT ADJUST PRESSURE OR DO AWARNING RE PRESSURIZE THIS PRODUCT EXCEPT FOR ANY ADJUSTMENTS MADE AT THE TIME OF INITIAL INSTALLATION WHEN THE UNIT IS NEW RE
3. PRESSURIZATION OF A WEAKENED DAMAGED OR CORRODED UNIT CAN CAUSE AN EXPLOSION POSSIBLY CAUSING SERIOUS OR FATAL PERSONAL INJURY AND OR PROPERTY DAMAGE If pressure adjustments are necessary because of changes in inlet pressure check the condition of the unit first to make sure there is no corrosion of the tank or any connected lines or fittings Take appropriate precautions Never adjust the pressure if water is leaking from the air stem Replace any damaged or corroded tank Also air loss is an indication that damage corrosion or weakening of the unit may have occurred and it should not be re pressurized Maintenance Your AMTROL Pressuriser unit including the pump must be periodically inspected by an experienced professional for signs of damage corrosion and leaking The pump should be checked to ensure it is turning on and off at the appropriate cut in and cut out points At a minimum after installation a thorough inspection of all components should take place annually However note that units in settings with frequent use where corrosion high humidity or aggressive water is more likely to occur and as the unit ages should be inspected more frequently Warranty Two 2 Year Limited Warranty Visit www amtrol com for complete warranty details Troubleshooting The Guardian CP incorporates built in diagnostics If the AMTROL Pressuriser is not functioning properly or is inoperable look for a error code example E1
4. ATER SYSTEMS e DO NOT RE PRESSURIZED TANK AFTER INSTALLATION e DO NOT PIPE EXCEPT WITH METAL PIPING AT INLET AND OUTLETS The system must be placed indoors only on a solid level surface with a drip pan piped to a drain with adequate capacity for large volumes of water in the event the system ruptures or fails Consider the risks posed by tanks under pressure and the potential for leaking and or flooding damage in selecting the location The unit must not be placed in an environment that would expose the water in the tank to temperatures below freezing or in excess of 100 F Figure 1 INITIAL Be sure to leave a minimal clearance of 12 around the unit for access should field adjustments be necessary in the future and to permit maintenance and inspection Figure 1 Amtrol Pressuriser ADANGER Before attempting any service and disassembly shut off power to the pump Ensure power is disconnected prior to removing motor Ensure power is disconnected before cleaning is attempted DANGER Grounding of the pump is essential for your protection and the protection of the motor All wiring should be completed by a licensed electrician and in accordance with local codes or in their absence the National Electrical Code Before starting the wiring installation disconnect all power to the circuit to be used for the AMTROL Pressuriser The AMTROL Pressuriser should only be A WARNING connected to a municipal cold wat
5. ONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE AS APPLICABLE A WARNING This Product like most Products under pressure may over time corrode weaken and burst or explode causing serious or fatal injury leaking or flooding and or property damage To minimize risk a licensed professional must install and periodically inspect and service the Product A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage Do not locate in an area where leaking could cause property damage to the area adjacent to the appliance or to lower floors of the structure CALIFORNIA PROPOSITION 65 WARNING This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm California Installer Contractor California law requires that this notice be given to consumer end user of this product For more information www amtrol com prop65 html AWARNING RUPTURE OR EXPLOSION HAZARD Do not expose Product to freezing temperatures or temperatures in excess of 200 F Do not adjust the pre charge or re pressure this Product except during installation or regular inspection Replace the Product and do not adjust the precharge if corroded damaged or with diminished integrity Adjustments to pre charge must be done at ambient temperature only Failure to properly size the Product or follow these instructions may result in excessive strain on t
6. after the shut off valve to the suction side of the pump as shown 8 Connect the house supply line using a 100 psig maximum relief valve as shown Figure 2 It is important that the pressure relief valve be installed on the pump discharge prior to any shut off valves ELECTROCUTION HAZARD DISCONNECT ADANGER ALL ELECTRICAL POWER BEFORE SERVICING THE GUARDIAN CP MUST BE ELECTRICALLY GROUNDED The Guardian CP will operate on 115 vac amp 230 vac systems 9 Disconnect power and verify with a volt meter 10 Determine the pump electrical requirements If unknown contact the pump manufacturer 11 Select the appropriate wire gauge per local codes and the pump manufacturers recommendation All pumps are 1 2 horsepower and are rated at 10 6 amps for 115 volts and 5 3 amps for 230 volts 12 Loosen the captive fastener on the top of the controller and remove the plastic cover exposing the wire leads When reassembling cover do not over tighten fastener 13 Following all electrical codes wire the Guardian CP Figure 3 The Guardian CP has openings to accept standard conduit terminations DO NOT INSTALL ON ELECTRICAL SERVICE A WARNING RATED ABOVE 20 AMPS 14 Close the bypass valve Figure 3 A BASIC GUARDIAN CP WIRING Factory wiring to pump 15 Open the city water supply line valve and a faucet and check the system for leaks repair any leaks before proceeding 16 Shut off the fauc
7. er supply and in systems with a minimum pressure of 10 psig at all times measured under flow at the tap closest to the location of the AMTROL Pressuriser installation Installation 1 Remove protective air valve cap 2 Check pre charge pressure pressure should be or 10 of the factory setting Factory pre charge is 38 psig 3 Release or add air as necessary to make the pre charge pressure 2 psig below the pressure switch pump cut in setting 4 Replace protective air valve cap Remove air valve label replace protective air valve cap peel off backing of label and apply on air valve cap MINIMUM SUPPLY LINE AND METER SIZE FOR IMPORTANT THE RP 10HP IS THE RP 15HP IS 1 AND THE RP 25HP IS 1 4 THIS APPLIES TO ALL LINES INCLUDING THOSE USED WITH THE WATER METER OR FITTINGS BEFORE THE PUMP CONTACT FACTORY IF MINIMUM FITTING LINE SIZE IS BELOW THE ABOVE NUMBERS 5 Install a SPRING LOADED CHECK VALVE in the city supply line on the suction side of the pump along with a shut off valve Failure to do so will result in premature failure of the AMTROL Pressuriser due to excessive pump cycling 6 Install a by pass loop Figure 2 Figure 2 BYPASS LOOP DS RP 10HP RP 15HP RP 25HP TO SYSTEM SHUT OFF 7 a t FLOW VALVES PRESSURE A RELIEF CITY WATER SUPPLY SPRING CHECK VALVE 7 Pipe the city supply
8. et and check the system for leaks Repair any leaks before proceeding IF THE CONTROL SWITCH IS SET TOO HIGH OR IMPORTANT THE PUMP IS RUNNING WHEN THE WATER SUPPLY IS SHUT OFF AND THERE IS NO DEMAND ON THE SYSTEM THE PUMP WILL POTENTIALLY RUN CONTINUOUSLY CAN OVERHEAT AND CAUSE DAMAGE RESULTING IN PRODUCT FAILURE LEAKING AND OR RUPTURE TO REDUCE THIS RISK NEVER EXCEED 80 PSIG CUTOUT Start Up BEFORE CONTINUING ENSURE THAT ALL A WARNING WIRING IS COMPLETED AND THE UNIT IS GROUNDED CHECK FOR OPEN DRAIN VALVES OR OTHER SOURCES OF FLOODING BEFORE STARTING UNIT 1 Prime pump if necessary and adjust tank precharge to manufacturer s recommendation for intended pressure range The factory Guardian CP setting is 40 psi cut in and 60 psi cut out 2 Turn on power and ensure Guardian CP display illuminates Display will blank momentarily and the pump will start If not check installation The display will now read the current line pressure Allow the pump to reach the factory cut off setting of 60 psi IF THE PUMP CANNOT REACH THIS SETTING DISCONNECT POWER AND SEE THE TROUBLESHOOTING SECTION 5 Check for leaks and repair as necessary Pe Programming the Guardian CP Differential pressure should be adjusted to no greater than 35 psi nor lower than 10 psi The 20 psi factory differential is recommended 1 Press and hold m When LO appears release This will determine the pressure at which the pump activates 2
9. he system and may lead to Product failure serious or fatal personal injury leakage and or property damage A relief valve must be installed to prevent pressure A WARNING in excess of local code requirement or maximum working pressure designated in the Product Manual whichever is less At least once every 3 years or if discharge is present a licensed contractor should inspect the temperature and pressure relief valve and replace if corrosion is evident or the valve does not function FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD UP WHICH CAN RESULT IN PRODUCT FAILURE SERIOUS INJURY OR DEATH AND OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY A WARNING Chlorine amp Aggressive Water The water quality can significantly influence the life of this Product You should test for corrosive elements acidity total solids and other relevant contaminants including chlorine and treat your water appropriately to insure satisfactory performance and prevent premature failure PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY IMPORTANT GENERAL SAFETY INFORMATION ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS If the control is set too high or the pump is running A WARNING when the water supply is shut off and there is no demand on the system the pump will run continuously can overheat and become damaged potentially resulting in product failure leaking and o
10. le pump is off and gauge If water emerges from tank air stem when depressed replace tank pressure is zero To reset control at any time press a m w buttons simultaneously for 5 seconds To invert the display for easier viewing press a together for 3 seconds E1 Rapid cycle Switch continues to operate See Pump Starts Too Often above Excessive amp draw Have pump checked for proper operation E2 Low suction Shuts off pump Auto restart 1 Determine cause of low suction running pressure after 60 min 2 Check Wiring below 10 PSI 3 Inspect pump E3 Improper voltage Shuts off pump Restore voltage to proper range Pump automatically restarts with proper voltage THE GUARDIAN CP CONTROL CONTAINS NO SERVICEABLE PARTS REMOVAL OF MAIN CIRCUIT BOARD COVER WILL VOID WARRANTY A ANTIMICROBIAL PROTECTION NSF ANSI 61 2014 AMTROL Inc AMITROL 1400 Division Road West Warwick RI USA 02893 T 800 426 8765 F 800 293 1519 www amtrol com ha o Mark of the Originator PHCC O68 MADE IN USA Part 9040B140 07 14
11. on the digital readout before proceeding Error codes are listed in the table at the bottom of this page Pump will not start Pump runs but will not build pressure Pump builds pressure but will not shut off 1 No Power Faulty wiring Damaged motor Damaged control Supply closed blocked 2 Bypass loop open 3 Pump plumbed backwards 4 Bad internal parts 1 Operating pressure set too high Bad internal parts Control line blocked 1 2 2 Close bypass valve Reverse inlet outlet 1 Reduce control setting as necessary If display illuminates with no error code but pump will not start If power is present at L1 L2 but display is blank replace control Open all supply valves ensure check valve is not sticking clean Check for bad seals or broken impeller Repair or replace as Check for bad seals or broken impeller Repair or replace as Remove control line and blow compressed air to clear Check circuit breaker and fuses tighten connections Check wiring per installation diagram in this booklet If pump hums but will not start check pump motor wiring 115 230V replace pump any filters necessary necessary Pump starts too often cycles under 30 sec 1 Control differential too narrow Tank precharge incorrect Waterlogged pressure tank 1 Set cut in and cut out 20 psi apart Set air pressure 2 psi below cut in whi
12. r rupture AWARNING All wire and fuse sizings are preliminary recommendations only For your safety local codes and in their absence national codes must be followed to minimize the risk of electric shock property damage or personal injury The pump motor is designed for use with single WARNING phase 60Hz ac Use with any other type of power will cause damage to the motor The pump models RP 10HP RP 15HP and RP25 HP are pre wired for 115 vac however they can be rewired to be used with 230 vac Consult motor nameplate for the wiring diagram The power for your pump must be on a dedicated CAUTION circuit In addition a shut off switch should be visible and near the pump Use a 20 amp circuit Water Meter Sizing Chart Minimum Flow Rate From City Supply Minimum Flow Pressure From City Supply Minimum Incoming Pipe Size Amtrol Pressuriser Metal piping must be used for all inlet and outlet lines to the unit Do not oversize pump Inadequate water supply will result in poor performance and pump damages Pre Installation e DO NOT USE FOR PRE HEATED WATER SUPPLIES e DO NOT USE FOR ANYTHING EXCEPT COLD WATER AMBIENT TEMPERATURE NOT TO EXCEED 100 F e DO NOT USE IN SYSTEMS WHERE LOW PRESSURE IS DUE TO LEAKS OR WHERE LEAKS IN THE PLUMBING SYSTEM MAY EXIST e DO NOT USE IN SYSTEMS WHERE THE WATER SUPPLY CAN DROP BELOW 10 PSIG e DO NOT USE IN SERIES WITH ANOTHER PUMP SUCH AS IN PRIVATE WELL W