Home
American Standard M968983 User's Manual
Contents
1. Atmtrican Standard ONE CENTRAL THERMOSTAT LESS VOLUME CONTROL TRIM KIT Installation Instructions TO64730 Thank you for selecting American Standard the benchmark of fine quality for over 100 years z Certified to comply with ANSI A112 18 1M To ensure that your installation proceeds smoothly please ass 1016 read these instructions carefully before you begin M968983 ROUGHING IN DIMENSIONS R510 1 2 NPT R530 200mm 3 4 NPT 7 7 8 R510 1 2 NPT R530 3 4 NPT ar 48mm to 68mm 2 to 2 5 8 Recommended Tools lt gt ll 3 Flat Blade Screwdriver Phillips Screwdriver CARE INSTRUCTIONS Remove as much surface dirt and film using clear water and soft cotton cloth as described above E To keep your new faucet looking new please follow these simple care instructions m Use any of the following to remove tough surface DO E Simply rinse the faucet clean with clear water E Dry the faucet with a soft cotton cloth DO NOT E Do not use any abrasive cleaners cloths or paper towels E Do not use any cleaning agents containing acids polish abrasives or harsh cleaners or soaps Regular and routine cleaning will reduce the need for heavy cleaning and polishing If heavy cleaning is required the following procedures are recommended film and build up E Mild liquid detergents E Clear ammonia free liquid glass cleaners m Non
2. CK CLAMP 1 on the SECURING RING 2 to the right pull off KNOB MOUNT 3 and reinstall KNOB MOUNT 3 with arrow B pointing upwards SET HOT LIMIT STOP m The maximum mixed water temperature is set at 109 F at the factory This setting can be changed if desired m Remove the TEMPERATURE LIMIT STOP 4 H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F For 100 F adjustment turn the water supply on Turn KNOB MOUNT 3 until the spout temperature is 100 F Check that arrow marking A on the KNOB MOUNT 3 still points upward after adjusting the thermostat to 100 F If not pull out the RED LOCKING DEVICE 5 Remove KNOB MOUNT 3 without turning by sliding out as indicated by the arrow Reinstall the KNOB MOUNT 3 so that the arrow marking A points upwards Reinstall RED LOCKING DEVICE 5 OPERATING THE VALVE Turn on water supply on and test installed fitting If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed See step 3 for TRANSPOSED SUPPLY PIPING Operate valve from off to cold to hot Check temperature If max mixed water temperature is to hot or to cold see step 4 and re calibrate the valve M968983 A907090 YYYOA US84045 0070A ESCUTCHEON SCREWS HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a
3. acidic non abrasive gentle liquid or fully dissolved powder cleansers mixed according to manufacturers directions E Non abrasive liquid polishers m Once clean rinse faucet again with clear water to thoroughly remove cleaner or polish and blot dry with a soft cotton cloth Failure to follow these care instructions may damage the Faucet s finish TRIM INSTALLATION E Push CAP 1 over the O RING SEAL 2 E Push ESCUTCHEON HOLDER 3 with lightly greased O RING SEAL 4 over CAP 1 Attach with the two SCREWS 5 provided Align pins in back of ESCUTCHEON 5 with holes in ESCUTCHEON HOLDER 8 Push ESCUTCHEON 5 GREASE ESCUTCHEON 4 flush against finished wall O RING SEAL 2 HANDLE INSTALLATION E Align HANDLE 1 as shown and push onto KNOB MOUNT 2 E Tighten HANDLE SCREW 3 with flat blade screwdriver E Push INDEX CAP 4 into HANDLE 2 Should the hot and cold water supply pipes have been transposed making adjustment impossible proceed as follows Shut off water supply CHECK STOP z PP y BLUE TO RED E Remove handle and rim J E Remove check stops and re install them transposed Important note RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left CHECK STOP Turn the water supply back on and perform the temperature adjustment in step 4 RED TO BLUE TEMPERATURE CALIBRATION Check that arrow marking B points vertically upwards If not push the BLA
4. m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 12 00 Product names listed herein are trademarks of American Standard Inc AS America Inc 2007 ONE CENTRAL THERMOSTAT LESS VOLUME CONTROL TRIM KIT MODEL NUMBERS TO64730 M962630 0070A ESCUTCHEON HOLDER M3907612 YYYOA ESCUTCHEON KIT M908594 YYYOA HANDLE BASE M909438 YYYOA HANDLE INSERT M962631 YYYOA HANDLE SCREW AND INDEX BUTTON Replace the YYY with appropriate finish code CHROME 002 SATIN NICKEL 295 M968983
Download Pdf Manuals
Related Search
Related Contents
Calpefina Selladora Installations- und Betriebsanleitung Benutzerhandbuch Navigationssoftware ESTUCOLAN HoMedics FMS-275H Downloadable Instruction Book logique Manual do Utilizador Cisco 15454E-AP-MIC48V= rack accessory Tech Craft BAY3232B User's Manual Copyright © All rights reserved.
Failed to retrieve file