Home
American Standard 2425.XXXW-LHO User's Manual
Contents
1. Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 753456 100 REV A 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
2. E BOTTOM We recommend the use of mortar as bedding material sand is not recommended Apply enough bedding to support the complete bottom of the bath After the bedding has been poured and before it sets position whirlpool or bath within recess until the rim is leveled against the leveling stringers see Typical Recess Installation shown below The rim of the bath MUST NOT support weight Allow the bedding material to completey harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath FIG 1 SUGGESTED WHIRLPOOL BATH INSTALLATION METHOD WOOD STUDS WATERPROOF DRYWALL OR CEMENT BOARD 1 x 3 25 x 76mm WOOD TYPICAL RECESS INSTALLATION STRINGER FULL LENGTH STEEL STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE x SEALANT N ss 4 102mm a 4 DRYWALL 21 1 4 540mm o oe y 3 aes 60 1 8 w 3 gw 1527mm SCREW PN iow 1 x 3 25 x 76mm WOOD STRINGER FULL LENGTH ALLOW OPEN FRAMING ON PUMP MOTOR END OF WHIRLPOOL FOR PUMP CLEARANCE 753456 100 REV A 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observe
3. HAMPTON 5 x 32 INTEGRAL APRON WITH REMOVABLE ACCESS PANEL HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS American Standard 2425 XXXW LHO 2425 XXXW RHO WHIRLPOOL INSTALLATION INSTRUCTIONS ON OFF SWITCH lt 60 eg ge 1524mm 305mm WATER 10 1 4 ee RETENTION 260mm FLANGE 1gmm ES 8 JETS 3 SIDES A FINISHED see Fitting WALL SPECS FOR gt S a DIMENSIONS Ad n 406mm id ae emm jra ZA ee f l ae he PUMP Qu 813mm NL cuTOUT IN FLOOR FOR DRAIN ou O 1 A C L OF 3 2 AIR VALVES Na ACCESS TO PUMP MOTOR SUPPLIES remm THROUGH REMOVABLE FRONT ACCESS PANEL G L OF DRAIN G L OF SHOWER ARM FINISHED OPTIONAL TO WALLIN SAFE T HEATER 1 WATER REMOVABLE RETENTION_ BLANK FLANGE 7 NES 3 SIDES i C L OF OVERFLOW 3 1 2 FINISHED FLOOR USUALLY BETWEEN 65 amp 78 1651 amp 1981mm 12 305mm OPT C L OF VALVES CIL OF SPOUT TILING 4 A 89mm F fen FLANGE es papra oe re LEVELING STRINGER NOT FOR SUPPORT THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection the whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximu
4. d including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential Heater equipped models require a separate 15 amp maximum GFCI circuit SAFE T HEATER EQUIPPED MODELS REQUIRE A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 15 GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 753456 100 REV A 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this Motor chart are recommendations Hi Performance for copper conductors Rating only Always follow 120V Power Line local and national 1 6 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight
5. llation and before enclosing with wallboard tile etc water test the unit and check for leaks Do not make WATER DEPTH TO OVERFLOW FLOOR LOADING PROJECTED AREA PTS 15 381m 43 Lbs Sq Ft 208 Kgs Sq m CUBE FT PUMP WHIRLPOOL ELECTRICAL SPECIFICATIONS 1 6 HP 9 7 AMPS 120V 45 Gal 171 L 20 8 35 3 m General Installation Information Bath may only be installed in a recess type installation modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others IMPORTANT Water test unit before installation and enclosure Locate studs as required insure rough dimensions are proper plumb and square For whirlpools access to pump motor may be made through access opening in apron panel The following procedure must be used for all installations leveling support stringer should be as indicated this bath is not self supporting and must be supported along it s entire bottom Support with mortar or grout Position bathtub whirlpool within the recess check level front to back side to side and shim as necessary To secure the tub to wo
6. m performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e Safe T Heater 9075 120 List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Dealer List of Required Tools and Supplies TOP OF L UNDERSIDE DECK PFT E 21 1 4 OF DECK E iomim 546mm m REF ROUGH 5 DIM FLOOR BATH SUPPORT MATERIAL 1 1 2 N P T M THREADS 1 1 2 O D TAILPIECE 4 5 8 117mm Left hand version shown GENERAL SPECIFICATIONS FOR 2425 WHIRLPOOL INSTALLED SIZE 60 x 32 x 21 1 2 1524 x 813 x 546mm WEIGHT 115 Lbs 52 Kg WEIGHT w WATER 574 Lbs 258 Kg GAL TO OVERFLOW 55 Gal 208 L WHIRLPOOL MIN OPERATING VOL BATHING WELL AT SUMP BATHING WELL AT RIM 16 1 4 x 38 1 4 413 x 972mm 26 1 4 x 52 1 2 667 x 1334mm Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 1x3or 2x2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 15 amp GFI e Personal Safety Outlet Equipment e Cement Plaster e Caulking Gun Grout General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage Before insta
7. od studs use drywall screws w washers or roofing nails immediately above the flange of the tub To secure the tub to steel studs use 4 drywall screws and flatwashers See page 2 for complete installation information Caution Take extra care when driving nails or screws to avoid damaging the tub The tile or similar finished floor will be butted against the bottom of the tub apron also holding the tub in place FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 753456 100 REV A American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS Locate studs as required Ensure roughing in dimensions are proper plumb and square Access to Pump Motor may be made through the access opening in the apron panel It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron may be used as the primary access opening 1 As shown in Fig 1 mark the position of the underside of the deck by tracing a line onto the studs using a level or other suitable straight edge 2 With the top of the stringer touching the traced line attach the stringer to the studs 3 Install drain components to the whirlpool or bath following the manufacturers instructions See the roughing in drawing for suggested opening size and location dimensions 4 THIS BATH MUST BE SUPPORTED ALONG ITS ENTIR
Download Pdf Manuals
Related Search
Related Contents
Diamond PCA46/47 Notebook User Guide User Manual - Voltage Stabilizer Anais da XVI Semana de Geografia da UEPG Optimus 32-1162 Karaoke Machine User Manual Untitled A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 B1 B2 C1 C2 A1 Quellen - Service CITROEN oui - Groupe GMI CC2543-CC2544 Development Kit User`s Guide Copyright © All rights reserved.
Failed to retrieve file