1. Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode E Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G m To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G mw Re install the Cam into the Drain rotating the Cam if necessary to make sure it Is fully inserted Fig J Re install the Gam Cap making sure the guide teeth are facing E outward If the Cam Cap does not snap into ae then rotate the Cam to make sure tt Is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in j Troubling Shooting Guide to complete installation Stopper will be Locked Mode in Locked mode and not be removable Vandal Proof Unlocked Mode 7 Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into m the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if neces
2. STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A m Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B E Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C m Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A S n LIFT KNOB STOPPER REMOVAL PROCEDURE m Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A m Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B E Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D E Remove the Gam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F BE CAM N r REMOVE CAM CAP M968866 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode
3. inlet of left SHANK and COLD water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS COUPLING Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet 1 1 2 PIPE THREAD 3 BULL NOSE COMPRESSION 2 RISERS sie FLEXIBLE 1 FLEXIBLE ence fd 3 8 FERRULE 3 8 COMPRESSION CONNECTION M968866 Rev 1 1 INSTALL HANDLES Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 with a spline is facing up Fig A Find correct position of LEVER HANDLE ASSEMBLY 3 by adjusting male teeth on ADAPTER 1 to female teeth in HANDLE 3 Install LEVER HANDLE ASSEMBLY 38 onto Adapter 1 Insert HANDLE SCREW 4 and tighten Thread INDEX BUTTON 5 into HANDLE ASSEMBLY 4 1 0 TEST INSTALLED FITTING m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks mM Remove AERATOR 3 mM Operate both HANDLES 1 to flush water lines thoroughly E Replace AERATOR 3 zi NE Sw lt A di AP ESF D ms I 1 1 CHECK DRAIN CONNECTIONS KE IV VV E Operate POP UP KNOB 5 and fill lavatory with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Sink If STOPPER 4 does not seal properly please refer to Troubleshooting section in these instructions S WASTE OUTLET E Release POP UP KNOB 5 down and check all drain conn
4. Installation HAMILTON Instructions Widespread Lavatory Faucet with 7028 EverClean Finish amp Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed Connect Drain two features found only on American Standard faucets l Certified to comply with ANSI A112 18 1 EverClean Finish Speed Connect Drain M968866 Rev 1 1 e One wipe effortlessly removes spots e 1 3 of the parts installs in 1 3 of the time e Eliminates the need for cleaners and scrubbing e No tools needed e Permanent surface protectant remains beautiful Never needs adjustment for the life of the faucet e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect Drain Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools SS F Screwdriver Channel Locks Adjustable Wrench Tubing Cutter BB srai spout MEE ippies tekst beginning E Insert SPOUT 1 and CABLE CONNECTOR 14 through center hole making sure the SPOUT ESCUTCHEON 2 and SEAL WASHER 38 are properly seated m Assemble RUBBER WASHER 4 BRASS WASHER 5 and LOCKNUT 6 onto SPOUT SHANK 7 from under side of sink Make sure SPOUT 1 is centered in the mounting hole and th
5. OCKNUT Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up E Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that eae SIDE oF igen WHITE FOAM GASKET 3 is fully compressed GRAY LOCKNUT and not visible Fig B MUST FACE UP D POP UP KNOB E POP UP KNOB 1 must be fully down M968866 Rev 1 1 6 ATTACH CABLE CONNECTOR r CHECK OPERATION OF POP UP m Thread HOSE CONNECTOR 6 6A to VALVE CONNECTIONS 7 7A m Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B NOTE Tailpeice on pop up drain is 1 1 4 OD Fig B Operate LIFT KNOB 1 to verify that STOPPER 2 Opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Thread TEE BODY 4 to SPOUT SHANK 5 SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to
6. e slot in the BRASS WASHER 5 faces toward the rear of the sink m Tighten LOCKNUT 6 firmly Fig A 1 A INSTALL VALVE BODY m Place RUBBER RING 9 into VALVE ESCUTCHEON 10 m Install LOCKNUT 411 and RUBBER WASHER 12 onto VALVE BODY 13 From under side of mounting surface install VALVE BODY 13 through valve mounting hole Threads of VALVE BODY 13 should extent at least 5 16 of a inch above mounting surface top Fig B Important Thread ESCUTCHEON 10 onto VALVE BODY 13 until snug against internal stop This is key to the installation If not done the faucet handles won t work correctly If necessary adjust LOCKNUT 11 1 E Lys tt LOCKNUT 41 with WRENCH 8 supplied to secure VALVE BODY 13 Repeat above steps for opposite VALVE BODY 13A MOUNTING SURFACE 5 16 MIN INSTALL POP UP DRAIN REAR OF Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A E Drop DRAIN BODY 4 through sink drain hole Make sure WHITE FOAM GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required m The CABLE ATTACHMENT POINT 6 must face towards the rear of the SINK Fig B INSTALL BLACK GASKET Install BLACK CONE GASKET 1 onto DRAIN BODY 2 from below Note The flat side of the BLACK CONE GASKET 1 must face down FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY L
7. ections and P trap for leaks Tighten if necessary VVVVYVYNYNYNYNNNYISS Ss i Sas NF 2 HOT EverClean Finish Care Instructions American Standard s EverClean E To change direction of handle rotation finish will wipe clean with a soft proceed as follows dry cloth Turn valve to OFF position Unthread INDEX A soft cloth with cl t BUTTON 1 Remove HANDLE SCREW 2 SUIS GIOUN WIGI CEANUWALEE Pull HANDLE 3 off VALVE STEM 48 may also be used if desired Remove SPRING CLIP 5 Lift STOP WASHER 6 No additional cleaning products turn 90 and replace Replace SPRING CLIP 5 are required Find correct position of HANDLE 3 by adjusting male teeth ao STEM 4 to female teeth e in HANDLE l DO NOT USE Soaps acid Re install HANDLE 3 SCREW 2 and INDEX polish abrasives harsh BUTTON 1 cleaners or a cloth with a If soout drips operate handles several times from OFF coarse surface to ON position Do not force handles turn only 9O M968866 Rev 1 1 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow
8. ll go Push Drain Body up into Sink and unthread Flange from Drain Body Remove Drain Body from below sink For Drains that are removed from above Sink E Unthread Tailpiece from Drain Body E Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks Suggest spraying nut with spray lubricant to loosen any corrosion or debris that may have built up Push Drain Body up into the Sink and remove Note If Drain body rotates while loosening Mounting Nut insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed Required tools mane Channel Locks Adjustable Wrench Phillips Screwdriver WHEN DRAIN IS REMOVED WHEN DRAIN IS REMOVED FROM ABOVE SINK FROM BELOW SINK METAL OR PLASTIC TWO PIECE METAL DRAIN BODY WITH PLASTIC DRAIN BODY DRAIN BODY PLASTIC TAILPIECE WITH PLASTIC TAILPIECE mN STOPPE 4 STOPPE STOPPER PLASTIC UNTHREAD DRAIN BODY l FLANGE SINK METAL OR PLASTIC P aS DRAIN BODY ROD NUT TT NUT and ROD NUT TO NUT and TF MOUNTING GASKET GASKET PLASTIC PLASTIC TAILPIECE TAILPIECE FINISHED WALL M968866 Rev 1 1
9. sary m to make sure tt is fully inserted Fig J LOOP TOWARD Re install the Gam Cap making sure the guide teeth are facing FRONT OF SINK g outward If the Cam Cap does not snap into pe then rotate Cor the Cam to make sure It is fully inserted Fig K DRAIN Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation Stopper will be Unlocked Mode in Unlocked mode and removable INSTALL CAM CAP M968866 Rev 1 1 TIPS FOR REMOVING YOUR OLD DRAIN Most existing drains can be removed quickly and easily with only a pair of channel lock pliers or a wrench However there may be situations where it is difficult to remove your old drain or determine how the drain is disassembled Depending upon the existing Drain in your sink it is either removed from above or below the sink The illustrations below show some typical drain installations and how they are disassembled from the sink The following tips can help with some of the more common challenges in drain removal mM Loosen nuts on P Trap using channel locks Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up Remove P Trap half from Tailpiece Use bucket to catch any residual water in P trap E Unthread Pivot Rod Nut from Drain Body and remove Pull Stopper out from Drain Body For Drains that are removed from below Sink m Loosen Mounting Nut as far down as it wi