Home

American Standard Enfield 2373.920 User's Manual

image

Contents

1. 1 3 16 DIA 3 4 14 MALE N PT INLETS 171 16 DIA SPOUT ASSEMBLY 2 PREPARE TUBE AND TEE ASSEMBLY Pay Ni bie ee urn off hot and cold water Prepare TUBE and TEE ASSEMBLY 1 to fit center to center supplies before beginning VALVE 2 location between 6 1 2 and 12 If necessary cut and or bend TUBING carefully Make sure tube bend is Install RING WASHER 1 into SPOUT BASE recess Check close to the TEE 1 so that it will not effect the compression that O RING 2 on end of SPOUT SHANK 8 is in place Insert joint at the VALVE CONNECTION SPOUT SHANK 3 through SPOUT ESCUTCHEON 4 and into center hole on mounting surface Remove COUPLING NUT 3 and FERRULE 4 from each VALVE 2 and slide onto TUBING 5 Assemble RUBBER WASHER 5 and LOCKNUT 6 onto SPOUT SHANK 1 Align SPOUT ASSEMBLY and from underside of ledge secure SPOUT ASSEMBLY into position with LOCKNUT 6 SPOUT ASSEMBLY SPOUT BASE g RECESS NED ADJ 6 1 2 TO 12 MOUNTING SURFACE MOUNTING SURFACE VALVE ASSEMBLY Install LOCKNUTS 1 and RUBBER WASHERS 2 onto valve shanks MOUNTING Push TUBING 3 ends into VALVE 4 side outlets Insert VALVES 4 SURFACE into mounting holes from underside of ledge Press TEE 5 onto SPOUT SHANK 6 making c
2. O Figure A PS Z SPLINE END DOWN SERVICE To change direction of handle rotation proceed as follows E Turn valve to OFF position Unthread HANDLE BASE 1 from DECK ADAPTER 2 HANDLE ASSEMBLY E Pull HANDLE ASSEMBLY off VALVE STEM 8 m Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 m Find correct position of HANDLE ASSEMBLY by adjusting male teeth on VALVE STEM 3 to female teeth in HANDLE m Thread HANDLE ASSEMBLY onto DECK ADAPTER 2 until snug against mounting surface HANDSHOWER INSTALLATION FOR 2373 901 921 Drop SPRAY ESCUTCHEON 1 through the fourth hole of the tub ledge 12 max from SPOUT center with SPRAY ESCUTCHEON 1 directed towards tub center Be sure RUBBER RING 2 is properly seated in ESCUTCHEON 1 Install RUBBER WASHER 3 and LOCKNUT 4 from underside of ledge Secure SPRAY ESCUTCHEON 1 by tightening LOCKNUT Add SEAL WASHER 5 and connect HOSE 10 to outlet nipple at the bottom of COUPLING 7 on the SPOUT SHANK 6 Tighten firmly Slip SHOWER HOSE 8 with COUPLING NUT through SPRAY ESCUTCHEON 1 Install SEALS 9 and connect both HOSES 8 and 10 Connect HAND SHOWER 11 to SPRAY HOSE 8 AeA When not in use HANDSHOWER should be seated in the HOLDER M968288 Rev 1 1 The flow rate of this Tub Filler exceeds 20 gallons minute at higher water pressure Do not fill bathtub unattended 7 TEST INSTALLED
3. abrasives harsh cleaners or a cloth with a coarse surface HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 8 00 p m EST IN MEXICO 01 800 839 12 00 IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2002 M968288 Rev 1 1
4. Amirim Standard Installation ENFIELD nstructions 2373 900 mitn bverClean Finish 233 920 Congratulations on purchasing your American 5 Le 2 Standard faucet with EverClean finish found only on American Standard faucets EverClean Finish One wipe effortlessly removes spots Eliminates the need for cleaners and scrubbing eee ea ee e Permanent surface protectant remains beautiful M968288 Rev 1 1 for the life of the faucet e EverClean available on Polished Chrome Satin Nickel Stainless Steel Polished Brass or any combination of these finishes To ensure that your installation proceeds smoothly please read these instructions carefully before you begin IMPORTANT NOTICE TO INSTALLER Please check with local Code Authority for the installation requirements of this product Some codes require an additional temperature mixing valve to limit the maximum hot water temperature and vacuum breaker for products with hand spray to be installed with this product Required Tools lt Soe TS y Flat Blade Screwdriver Adiuctable Wench Hex key Wrench i Channel Locks Supplied with Fitting ROUGHING IN DIMENSIONS CROSS LEVER m ADJ 6 1 2 TO 12 HANDLE HANDLE 5 3 16 MOUNTING SURFACE 1 1 2 MAX
5. FAUCET Turn VALVES 1 to off position With handles in off position turn on water supplies and check all connections for leaks Operate both handles and flush water lines thoroughly Check SPOUT 2 mounting for leaks Lift HAND SHOWER 3 from holder direct spray into tub lift TRANSFER KNOB 4 to check HAND SHOWER 3 and HOSES for leaks Turn VALVES off If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 Before the bathroom is completely finished you may want to remove spout hand shower and handles To remove handles reverse steps in section 4 To remove SPOUT 1 proceed as follows Lift TRANSFER ROD 8 and unscrew KNOB 2 Remove PLUG BUTTON 3 and remove SET SCREW 4 using 5mm hex Hex wench supplied wrench supplied Lift SPOUT 1 off SHANK 5 carefully and remove RUBBER RING 6 ras Unscrew SHANK SLEEVE 7 and lift TRANSFER ROD 8 from 8 SHANK 5 Reverse sequence to re install SPOUT 1 Be sure RUBBER 7 RING 6 is properly seated in its recess at the base of SPOUT 1 Make certain SET SCREW 5 is properly aligned and tight so that SPOUT 1 is locked in place YS EverClean Finish Care Instructions American Standard s EverClean finish will wipe clean with a soft dry cloth A soft cloth with clean water may also be used if desired No additional cleaning products are required DO NOT USE Soaps acid polish
6. ertain that the O RING 7 is properly seated on SHANK 6 Push COUPLING 8 or 8a into TEE 5 and attach to SPOUT SHANK 6 and tighten Note For product with Hand Shower COUPLING 8 is tightened using a 10mm 3 8 Hex Wrench Thread of VALVE BODY 4 should extend at least 5 16 inch above MOUNTING SURFACE 11 If necessary adjust LOCKNUT 1 Place RUBBER RING 10 into ESCUTCHEON ADAPTERS 9 and thread onto valves until snug against internal stop Tighten LOCKNUT 1 to secure VALVE 4 position Slide FERRULE 12 and COUPLING NUT 13 to outlet of VALVE 4 and tighten COUPLING NUT 13 firmly Connect HOT water supply to inlet of left VALVE and COLD water supply to aL 9 inlet of right VALVE using appropriate 4o connector 5 16 MIN 1 AR MOUNTING SURFACE A ZZA FOR FITTING a LESS SPRAY M968288 Rev 1 1 INSTALL HANDLES HM Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 without a spline is facing up See figure A Tighten STEM SCREW 3 to secure ADAPTER 1 Find correct position of LEVER HANDLE ASSEMBLY 4 or CROSS wo Be ero HANDLE ASSEMBLY 5 by adjusting male teeth on ADAPTER 1 to ADAPTER female teeth in HANDLE 4 5 Thread LEVER HANDLE ASSEMBLY 4 or CROSS HANDE ASSEMBLY 5 onto DECK ADAPTER 6 until snug against mounting surface

Download Pdf Manuals

image

Related Search

Related Contents

  米(PDF:1677KB)  Manuale monitor Vigileo - Terapia Intensiva NOCSAE  Targus Notebook Case 15.4"  2 - Sulky Burel  KM-300 取扱説明書ダウンロード(1.31MB  Oasys LS-DYNA Environment Software    

Copyright © All rights reserved.
Failed to retrieve file