1. OVERFLOW 63 Gal 239 L MIN OPERATING GAL THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not included e Safe T Heater 9075 120 Tile Bead Kit 751755 100 e Apron Kit see your American Standard Distributor List of Required Components not included e Drain 1583 470 Bath Filler see your American Standard Distributor List of Required Tools and Supplies BATHING WELL AT SUMP BATHING WELL AT RIM FLOOR LOADING PROJECTED AREA PTS 40 x 26 In 1016 x 660 mm 52 x 32 1 2 In 1321 x 826 mm WATER DEPTH TO OVERFLOW ______13 1 4 In 37 Lbs Sq Ft 182 Kgs Sq m 54 Gal 204 L 337 mm 27 8 CUBE FT 45 4 Tools Supplies e Level e Nails e Tape Measure e Putty Pipe Wrench e Caulking waterproof Slip J oint Pliers e 1x3 0r2 x2 e Screw Driver Stringers Standard Drop Cloth Woodworking Tools e 15 amp GFI e Personal Safety Outlet Equipment Cement Plaster WHIRLPOOL ELECTRICAL SPECIFICATIONS SYSTEM PUMP 1 6 HP 9 7 AMPS
2. 120V GENERAL INSTALLATION INFORM ATION e Caulking Gun Grout Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 752501 100 Rev J American Standard Inc 2005 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those sho
3. CADET 5 x 42 HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS 2772 XXXW SERIES American Standard WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS lt 1524mm 7 lt 305 mm gt 60 SE 2 RECOMMENDED FITTING LOCATION ON OFF ets e 76 X 330mm 3 x 13 FOR PIER OR ISLAND 19mm ea INSTALLATIONS ONLY SWITCH A FINISHED SEE FITTING WALL SPECS FOR gt DIMENSIONS f I I gt a zu i 1067mm T 3 lt _4 42 CUTOUT iN FOOR 533mm FOR DRAIN 21 y A 5 J CIL OF sAm 6 JETS 2 AIR VALVES XC OUTLINE OF CUTOUT SUPPLIES H j4 2 1 4 1486mm x 1029mm ALT FITTING LOCATION 58 1 2 X 40 1 2 C L OF DRAIN SHOWER ARM OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN CIL OF 1651 amp 1981mm s VALVES 65 amp 78 E O OVERFLOW 305mm G L OF 38 mim 12 _ SPOUT MLEVELING 1 1 2 A SAFE T HEATER STRINGER 76mm a REMOVABLE NOT FOR 3 1 E BLANK SUPPORT t ii 7s Se Svi 502 mm H 19 3 4 464 mm ROUGH g g 18 1 4 FLOOR INTEGRAL 1 1 2 N P T M SUPPORT THREADS 70 mm E mj FEET 4 4 2 O D TAILPIECE 2 3 4 GENERAL SPECIFICATIONS FOR 2772 WHIRLPOOL INSTALLED SIZE ____ 60 x 42 x 19 3 4 In 1524 x 1067 x 502mm WEIGHT 117 Lbs 53 Kg WEIGHT w WATER 642 Lbs 289 Kg GAL TO
4. and secure installation FIG 1 TILE JF Y ede WALLBOARD TILE SEALANT BEAD WA STRIP SATH ADHESIVE 464mm 18 1 4 LEVELING STRINGER NOTE Tile bead kit not included and must be purchased separately TYPICAL RECESS INSTALLATION TYPICAL PIER TYPE INSTALLATION AS DESIRED NOTCH STINGER AT HEATER BLANK NOTCH STINGER AT 1029mm SEE NOTE 2 ABOVE HEATER BLANK 40 1 2 1486mm a 58 1 2 SEE NOTE 2 ABOVE CUTOUT 464mm 18 1 4 464mm 18 1 4 AS DESIRED LEVELING SURFACE J WATERPROOF 1527mm e SEALANT 60 1 8 LEVELING STRINGERS ACCESS PANEL WHIRLPOOL ONLY UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED WHIRLPOOL ONLY UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 752501 100 Rev J ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for serv
5. icing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752501 100 Rev J 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor 50 100 150 for copper conductors Hi Performance j only Always follow Rating 115V Power Line local and national 1 6 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to
6. the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752501 100 Rev J 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
7. wn Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary Mark the final position of the underside of the deck by tracing a line on to the studs see Figure 1 2 Remove the whirlpool and attach a 2 x 4 stringer to the studs with the top of the stringer touching the traced line It may be necessary to notch stringer near the SAFETY T HEATER blank to avoid interference should heater be installed at a later date 3 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 4 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid
Download Pdf Manuals
Related Search
Related Contents
VHIS 35 Model User Guide - Aurora Multimedia Corp. Pelco C554M-A (5/98) Marine Radio User Manual Ford 2010 F-150 Automobile User Manual B500/B500-S Power Wheelchair Service Manual Page 1 Page 2 一度使うと、 手放せない! ガスファンヒーターが選ばれる Manual de Instalación de Java Intenso Music Dancer - CONRAD Produktinfo. Manual de Instalación, Uso y Mantenimiento Istruzioni asse da stiro «Vapo Tavola III» - Migros Copyright © All rights reserved.