American Dryer Corp. ML-82 III User's Manual

image

Contents

1. gt m S E EE y n a a mm m m UR y M O M J 0 TO IMPE G_GAS INFORMATION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes In the absence of such codes ALL plumbing connections materials and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223 1 LATEST EDITION or in Canada the Canadian Installation Codes CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Liquid Propane L P Gas or LATEST EDITION The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 18 American Dryer Corp 113344 9 1 Gas Supply The gas dryer installation must meet the American National Standard National Fuel Gas Code ANSI Z223 1 LATEST EDITION or in Canada the Canadian Installation Codes CAN CGA B 149 1 M91 Natural Gas or CAN CGA B149 2 M91 Liquid Propane L P Gas or LATEST EDITION as well as local codes and ordinances and must be d
2. ML 82 III Installation Manual Gas DSI Steam Models Phase 7 Fire Suppression System WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Clear the room building or area of all occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 0 American Dryer Corp AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage materiel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ e Ne pas tenter d allumer d appareils e Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le
3. Gas 10 5 Inches 26 1 mb Water Column IMPORTANT There is no regulator provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be added to each dryer 4 Steam Dryers Check to ensure that steam damper is functioning properly The steam damper should not slam open or closed when it reaches the end of piston travel Additionally the steam damper should not bind and or stop during travel If either of these conditions occur the flow control must be adjusted Refer to the illustration on page 25 for air adjustment instructions 5 Make a complete operational check of ALL safety related circuits a Door switch es b Hi Limit thermostats c Sail switch for gas models only 113344 9 www amdry com 29 NOTE Tocheck for proper sail switch operation for gas models only open the main door and while holding main door switch plunger in start dryer Dryer should start but heat circuit should not be activated on Ifthe heat system is activated the sail switch is improperly adjusted and must be adjusted by bending the actuator arm of the sail switch toward the burner box Ifthe actuator arm is bent too far toward the burner box of the dryer the dryer may not have heat when needed After any adjustment to the sail switch the above procedure must be repeated to verify proper operation of the sail switch 6 The dryer should be operated through one 1
4. 113344 9 K PREOPERATIONAL TEST ALL dryers are thoroughly tested and inspected before leaving the factory However a preoperational test should be performed before the dryer is publicly used It is possible that adjustments have changed in transit or due to marginal location installation conditions 1 Turn on electric power to the dryer Open ALL shutoff valves gas models only 2 Refer to the Operating Instructions for starting your particular model dryer 3 Gas Dryers a When a gas dryer is first started during initial start up it has a tendency not to ignite on the first ignition attempt This is because the gas supply piping is filled with air so it may take a few minutes for the air to be purged from the lines NOTE During the purging period check to be sure that ALL gas shutoff valves are open NOTE Gas dryers are equipped with a Direct Spark Ignition DSI system which has internal diagnostics Ifignition is not established within three 3 times the heat circuit in the DSI module will lock out until it is manually reset To reset the DSI system open and close the main door and restart the dryer b A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column W C pressure is correct and consistent NOTE Water column pressure requirements measured at the pressure tap of the gas valve body Natural Gas 3 5 Inches 8 7 mb Water Column Liquid Propane L P
5. 9 www amdry com 31 SECTION IV SERVICE PARTS INFORMATION A SERVICE Service must be performed by a qualified trained technician service agency or gas supplier If service is required contact the reseller from whom the ADC equipment was purchased Ifthe reseller cannot be contacted or is unknown contact the ADC Service Department for a reseller in your area B PARTS Replacement parts should be purchased from the reseller from whom the ADC equipment was purchased If the reseller cannot be contacted or is unknown contact the ADC Parts Department for a reseller in your area Parts may also be purchased directly from the factory by calling the ADC Parts Department at 1 508 678 9000 or you may FAX in your order at 1 508 678 9447 NOTE When ordering replacement parts from the ADC reseller or the ADC factory be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner 32 American Dryer Corp 113344 9 SECTION V WARRANTY INFORMATION A RETURNING WARRANTY CARDS Before any dryer leaves the ADC factory test area a warranty card is placed on the back side of the main door glass These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file a warranty claim If a warranty card did not come with your dryer contact the ADC Warranty Department or th
6. Lint Compartment Area lint screen located behind door Lint Drawer Data Label and Installation Label American Dryer Corp 113344 9 2 Dryer Rear View A Sy Illus No Description Heating Unit 2 1 8 Compressed Air Supply Inlet behind electric service relay box for steam units only Electric Service Relay Box Basket tumbler Bearing Mount Assembly Idler Bearing Mount Assembly Blower Motor Assembly Leveling Leg rear Basket tumbler drive Motor Assembly reversing models only Dryer Exhaust Ww DO D Ia Un Electric service connections for gas models and steam models are made in this box 113344 9 www amdry com SECTION HI INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes In the absence of these codes the installation must conform to applicable American National Standards ANSI Z223 1 LATEST EDITION National Fuel Gas Code or ANSI NFPA NO 70 LATEST EDITION National Electrical Code or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Liquid Propane L P Gas or LATEST EDITION for General Installation and Gas Plumbing or Canadian Electrical Codes Parts 1 amp 2 CSA C22 1 1990 or LATEST EDITION for Electrical Connections A LOCATION REQUIREMENTS Before installing the dryer be sure the location conforms to local codes and
7. Returning Warranty Cards 0 c cccccccssccssecsseceseceeceecseecsececseecsaecsaecnseceaeceseceseseeeeessecsaecasecaecnseeeeeeteeeaaes 33 B Warranty A A A E sanepinee dade a a aka 33 C Retiring Warranty Parts anse net tite snaeyeah lie 33 SECTION VI ROUTINE MAINTENANCE ssstecssssdeaseesctveccentesosdsisanesssenessvacessuascenvstgstavnssadencsostansbesessuecapossssetenuslabesmedssennd 35 Are Clea ine sinistre tb nt tee ent de M ea en tete be 35 Bis Adjustments sans O O NN 36 A cee does nn etant nent ca eva ea bola ca E AEE rent anne enter set LA 36 Dy Lint Drawer Removal timo a de sede stat a nina net re 37 SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS ss 38 SECTION VIII DATA LABEL INFORMATION cccssscssssssssssssscssscsscssssssesescessessonsssssonsesesossesessonsesesonsesessssssessonsesesosees 40 SECTION IX MANUAL RESET BURNER HI LIMIT INSTRUCTIONS oocccncncooccoccccnnnnnnnoniccononnnnonanananincconcnnccnacananoso 41 Ais Phase 7 ait nn Re ne A IER TER oe Al Bes Dual Ter sn OTRA Al SECTION I SAFETY PRECAUTIONS 1 DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 2 Purchaser user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas The instructions should be posted in a prominent location 3 WHAT TO DO IF YOU SMELL GAS a DO NOT try to light a
8. branch circuit The dryer must be connected with copper wire only DO NOT use aluminum wire it could create a fire hazard The copper conductor wire cable must be of proper ampacity and insulation in accordance with electric codes for making ALL service connections NOTE Theuse of aluminum wire will VOID THE WARRANTY IMPORTANT A separate circuit servicing each dryer must be provided 16 American Dryer Corp 113344 9 2 Electrical Service Specifications Gas and Steam ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT 208 VAC AND 230 240 VAC ARE NOT THE SAME When ordering specify exact voltage NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying either local and or National Electrical Codes to listed appliance amp draw data B Circuit breakers are thermal magnetic industrial motor curve type ONLY For others calculate verify correct breaker size according to appliance amp draw rating and type of breaker used C Circuit breakers for 3 phase 39 dryers must be 3 pole type SERVICE piace WIRE y CIRCUIT VOLTAGE SERVICE MP DRAW BREAKER 208 30 3 144 20 240 30 3 140 159 20 380 400 30 4 64 15 416 30 4 87 15 440 30 4 86 15 460 480 30 3 i 15 Contact factory for 3 wire system 8 4 08 IMPORTANT The dryer
9. complete cycle to assure that no further adjustments are necessary and that ALL components are functioning properly BASKET TUMBLER COATING The basket tumbler is treated with a protective coating We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the basket tumbler to remove this coating 7 Make a complete operational check of ALL operating controls Microprocessor controller computer programs selections Each microprocessor controller computer has been preprogrammed by the factory with the most commonly used parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer 8 Check the electric service phase sequence 3 phase 36 models only While the dryer is operating check to see if the blower wheel impellor fan is rotating in the proper direction Looking from the front the blower wheel impellor fan should spin in the clockwise CW direction Ifit is the phasing is correct If the phasing is incorrect reverse two 2 of the three 3 leads at connections L1 L2 and L3 of the power supply to the dryer 9 Reversing basket tumbler dryers should never be operated with less than a 53 lb 24 04 kg load dry weight since the load s weight affects basket tumbler coast time during a direction reversal command It is important that the basket tumbler come
10. information necessary to process claim Ifreply is not received by the ADC Warranty Department within thirty 30 days from the FAX letter date then no replacements credits or refunds will be issued and the merchandise will be discarded 34 American Dryer Corp 113344 9 SECTION VI ROUTINE MAINTENANCE A CLEANING A program and or schedule should be established for periodic inspection cleaning and removal of lint from various areas of the dryer as well as throughout the ductwork system The frequency of cleaning can best be determined from experience at each location Maximum operating efficiency is dependent upon proper air circulation The accumulation of lint can restrict this airflow If the guidelines in this section are met an ADC dryer will provide many years of efficient trouble free and most importantly safe operation WARNING KEEP DRYER AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hours per day IMPORTANT Dryer produces combustible lint and must be exhausted to the outdoors Every 6 months inspect the exhaust ducting and remove any lint buildup SUGGESTED CLEANING SCHEDULE EVERY THIRD OR FOURTH LOAD Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint screen is located beh
11. must be connected to the electric supply shown on the data label In the case of 208 VAC or 240 VAC the supply voltage must match the electric service specifications of the data label exactly IMPORTANT The wire size must be properly sized to handle the related current WARNING 208 VAC AND 240 VAC ARE NOT THE SAME Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation 3 Electrical Connections NOTE A wire diagram is located in the front electrical control box for connection data NOTE A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED 113344 9 www amdry com 17 For gas and steam dryers manufactured for operation LS at 3 phase 39 the electrical connections are made a at the power distribution block located in the service box at the rear upper left hand corner of the dryer To gain access to the service box and contactor the service box cover must be removed Providing local codes permit power to the dryer can be made by the use of a flexible U L listed cord or pigtail wire size must conform to the rating of the dryer or the dryer can be hard wired directly to the service breaker In ALL cases a strain relief should be used both where the wiring enters the dryer and the service box
12. the T or three way fitting located in the outlet supply side of the water solenoid valve The use and connections of this manual bypass are at the option or discretion of the owner The water connection for the manual bypass is made to the T or three way fitting which has a 3 8 F P T and a coupling must be used to provide the minimum 1 2 supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water lines from freezing fase SOs Re eee ee ay Legh at isa fn A i ii A IN i 1 UN Le e aaa ll WARNING Ifthe water in the supply line or water solenoid valve freezes the fire suppression system will be INOPERATIVE The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it is easily accessible 113344 9 www amdry com 27 c Electrical Requirements No independent external power source or supply connection is necessary The 24 volt power to operate the fire suppression system is accomplished internally in the dryer from the dryer controls WARNING Electrical power must be provided to the dryer at ALL times If the main electrical power supply to the dryer is disconnected the fire suppression system is INOPERATIVE J PREPARATION FOR OPERATION START UP The fol
13. the ductwork can only be increased to an extent When the ductwork approaches the maximum limits noted in this manual a professional heating ventilating and air conditioning HVAC firm should be consulted for proper venting information ALL ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it is to be connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible 3 materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct must be centered within this opening Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the ductwork travels vertically up through the roof it should be protected from the weather by using a 180 turn to point the opening downward In either case allow at least twice the diameter of the duct between the duct opening and the nearest obstruction Multiple Dryer Common Venting If it is not feasible to p
14. the flame is not sensed at the end of the third retry trial inter purge period of 30 seconds the DSI module will LOCK OUT ared L E D diagnostic indicator will flash An unlit red L E D diagnostic indicator indicates normal operation A lit green L E D diagnostic indicator indicates dryer controller is calling for heat and that ALL interlocks have been satisfied 113344 9 www amdry com 39 SECTION VIII DATA LABEL INFORMATION 2 a j N M Wy Ka 3 xo ON EN 4 H Ben 0 NY NS SN 7 ELECTRIC SERVIC 4 MINIMUM GAS SUPPLY PRESSUR MAXIMUM GAS SUPPLY PRESSURE x GAS MANIFOLD PRESSURE 19 FOR USE WITH GASES CLOTHES DRYER VOL FOR CANADIAN INSTALLATIONS WITH ELEVATIONS BETWEEN 2 000 AND 4 500 FT HEAT INPUT ORIFICE SIZE MAN6904 When contacting American Dryer Corporation certain information is required to ensure proper service parts information from ADC This information is on the data label located on the upper left side panel area behind the top control access door When contacting ADC please have the model number and serial number available 1 MODEL NUMBER Describes the size of the dryer and the type of heat gas electric or steam 2 SERIAL NUMBER Allows the manufacturer to gather information on your particular dryer 3 MANUFACTURING CODE NUMBER The number issued by the manufacturer which describes ALL possible options on your particular model 4 TYPE OF HEAT Thi
15. to a complete stop prior to starting in opposite direction a Spin and dwell stop times are not adjustable in the Automatic Mode and have been preprogrammed into the microprocessor controller computer for a 120 second spin time in forward direction 120 seconds in the reverse direction and a 5 second dwell stop time b Spin and dwell stop times are adjustable in the Manual timed Mode 10 Check to ensure that ALL setscrews i e basket tumbler drive idler etc are tight 30 American Dryer Corp 113344 9 L PREOPERATIONAL INSTRUCTIONS To start the dryer 1 The light emitting diode L E D display will read REAdY 2 Press the E on the keypad 3 The dryer will start and the display will flash dRYING MANUAL CYCLE E dRY TEMP 180F COOL TEMP 80F 30 REMAIN and dRUM TEMP Refer to the User s Manual for detailed operating instructions M SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown taken out of service for a period of time the following must be performed 1 Discontinue power to the dryer either at the external disconnect switch or the circuit breaker 2 Discontinue the gas or steam supply a GAS MODELS discontinue the gas supply SHUT OFF external gas supply shutoff valve b STEAM MODELS discontinue the steam supply 1 SHUT OFF external location furnished shutoff valve 2 SHUT OFF external steam valves in the supply lines and the return lines 113344
16. 344 9 D LINT DRAWER REMOVAL To remove the lint drawer from the dryer pull drawer out approximately halfway Rotate and move lint drawer stop hinge downward and pull drawer out Refer to the illustration below IMPORTANT After reinstalling the lint drawer back into the dryer be sure to rotate move the hinge back to the upward stop position 113344 9 www amdry com 37 SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1 Microprocessor Controller Computer Board a Upon completing installation of the replacement microprocessor controller computer board reestablish power to the dryer b Start the drying cycle by pressing any of the preset cycles in letters A F GA GA AAA gt gt A B nie J PD xi WS HRK gt als C D SO y TEA A ee NS 7 7 8 9 gt N a aa a CLAS E F AUTO 0 MAN kt Y IA G gt gt G G gt O 1 Al y ue SS J y MC 8 02 01 MANS846 c Verify that the applicable indicator lights on the back side of the microprocessor controller computer board are lit Refer to the illustration below oN SX TN NE EN Ne ASAS n el g A Ce 38 American Dryer Corp 113344 9 2 For Model
17. ABLE 208 460V 3 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 928 lb 420 9 kg APPROXIMATE SHIPPING WEIGHT 978 lb 443 6 kg AIRFLOW 60 Hz 1 700 cfm 48 14 cmm 50 Hz 1 417 cfm 40 12 cmm e STEAM CONSUMPTION 375 lb hr 170 5 kg hr 49 OPERATING STEAM PRESSURE 125 psi max 8 6 bar Q EXHAUST CONNECTION DIAMETER 14 35 56 cm D COMPRESSED AIR CONNECTION 1 8 F N P T COMPRESSED AIR VOLUME 0 75 cfh 0 02 cmh BOILER HORSEPOWER NORMAL LOAD 11 Bhp SUPPLY CONNECTION 1 F N P T RETURN CONNECTION 1 F N P T Shaded areas are stated in metric equivalents 4 7 04 Steam dryers must be provided with a clean dry and regulated 80 psi 10 psi 5 51 bar 0 68 bar air supply NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation 4 American Dryer Corp 113344 9 Specifications NOT EXCEED 0 3 0 74 MB WATER COLUMN ANCE BAR AIR SUPPLY THIMBLE NNECTION IS SHIPPED INSIDE ELECTRICA ERICA OUTSIDE N AMERICA RON STEAM ONLY 04 NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation 113344 9 www amdry com 5 B COMPONENT IDENTIFICATION 1 Dryer Front View Illus No SU BR D Description Controls Control top access Door Assembly Main Door Assembly
18. BIND OR STICK A back draft damper that is sticking partially closed can result in slow drying and shutdown of heat circuit safety switches or thermostats When cleaning the dryer cabinets avoid using harsh abrasives A product intended for the cleaning of appliances is recommended B ADJUSTMENTS 7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER Inspect bolts nuts screws setscrews grounding connections and nonpermanent gas connections unions shutoff valves and orifices Motor and drive belts should be examined Cracked or seriously frayed belts should be replaced Tighten loose V belts when necessary Complete operational check of controls and valves Complete operational check of ALL safety devices door switches lint drawer switch sail switch burner and hi limit thermostats C LUBRICATION The motor bearings and under normal most conditions the basket tumbler and idler bearings are permanently lubricated It is physically possible to relubricate the basket tumbler and idler bearings if you choose to do so even though this practice is not necessary Use Shell Alvania 2 grease or its equivalent The basket tumbler and idler bearings used in the dryer DO NOT have a grease fitting Provisions are made in the bearing housing for the addition of a grease fitting which can be obtained elsewhere or from ADC by ordering kit P N 882159 basket tumbler only which includes two 2 fittings 36 American Dryer Corp 113
19. NOPERATIVE IMPORTANT Appliance is to be connected to the water mains using a new hose set and the old hose set should not be reused b Water Connections The water connection is made to the 3 4 11 5 NH hose adaptor of the electric water solenoid valve located at the rear upper midsection of the dryer refer to the photo The water solenoid valve has a 3 8 M P T connection supplied with a 3 4 11 5 NH hose adaptor to provide the minimum 1 2 inch supply feed line Flexible supply line coupling must be used in an effort to avoid damaging the electric water solenoid valve NOTE The 3 4 11 5 NH is a standard hose coupling screw thread It is not to be confused with 3 4 N P T The sealing of an NH connection is made with a washer opposed to the mating threads of an N P T assembly The two 2 thread designs are not compatible IMPORTANT Flexible supply line coupling must be used Solenoid valve failure due to hard plumbing connections WILL VOID WARRANTY It is recommended that a filter or strainer be installed in the water supply line 26 American Dryer Corp 113344 9 Typical water supply MG 12 3 03 MAN7032 OPTIONAL MANUAL BYPASS Provisions are made in the dryer s fire suppression system for the installation of an optional manual bypass Depending on the model dryer the connections for the manual bypass are made at
20. OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING ADJUSTING INSTALLATION OR TESTING OF ANY EQUIPMENT PER OSHA Occupational Safety and Health Administration STANDARDS 113344 9 www amdry com 3 SECTION II SPECIFICATIONS COMPONENT IDENTIFICATION A SPECIFICATIONS TUMBLER DIAMETER 37 94 cm TUMBLER DEPTH 36 91 5 cm TUMBLER VOLUME 22 4 cu ft 634 29 L TUMBLER DRIVE MOTOR 1 2 hp 0 373 kW BLOWER FAN MOTOR 3 hp 2 2 kW DOOR OPENING DIAMETER 31 3 8 79 7 cm DOOR SILL HEIGHT 25 63 5 cm WATER CONNECTION 3 4 11 5 NH North America 3 4 B S P T Outside North America DRYERS PER 20 40 CONTAINER 10 20 DRYERS PER 487 53 TRUCK 24 26 VOLTAGE AVAILABLE 208 460V 30 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 833 lb 377 8 kg APPROXIMATE SHIPPING WEIGHT 883 lb 400 5 kg AIRFLOW 60 Hz 1 700 cfm 48 14 cmm Y 50 Hz 1 417 cfm 40 12 cmm QG HEAT INPUT 270 000 Btu hr 68 040 kcal hr 0 EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 1 F N P T 1 B S P T CE and Australia Only VOLTAGE AVAILABLE 0 APPROXIMATE NET WEIGHT umm APPROXIMATE SHIPPING WEIGHT AIRFLOW 6 EXHAUST CONNECTION DIAMETER N A COMPRESSED AIR CONNECTION mm COMPRESSED AIR VOLUME LL OVEN SIZE kW Btu hr kcal hr VOLTAGE AVAIL
21. Y OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING ADJUSTING INSTALLATION OR TESTING OF ANY EQUIPMENT PER OSHA Occupational Safety and Health Administration STANDARDS Caution Label all wires prior to Attention Au moment de l entretien des commandes disconnection when servicing tiquetez tous les fils avant de les d brancher Des controls Wiring errors can cause erreurs de c blage peuvent entrainer un fonctionnement improper operation inad quat et dangereux CAUTION DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION WARNING CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER S CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION FOR YOUR SAFETY DO NOT DRY MOP HEADS IN THE DRYER DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES WARNING UNDER NO CIRCUMSTANCES should the dryer door switch lint drawer switch or heat safety circuit ever be disabled WARNING The dryer must never be operated with any of the back guards outer tops or service panels removed PERSONALINJURY OR FIRE COULD RESULT WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER SCREEN IN PLACE EVEN IFAN EXTERNAL LINT COLLECTION SYSTEM IS USED IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and or specified in the installation manual included with the dryer Dryer must not be installed or stored in an ar
22. ation a Model number and serial number of the dryer from which part was removed b Nature of failure be specific c Date of dryer installation d Date of part failure e Specify whether the part s being returned is for a replacement a credit or a refund NOTE Ifapart is marked for a credit or a refund the invoice number covering the purchase of the replacement part must be provided NOTE Warranty tags ADC P N 450064 are available at no charge from ADC upon request 3 The company returning the part s must clearly note the complete company name and address on the outside of the package 4 ALL returns must be properly packaged to ensure that they are not damaged in transit Damage claims are the responsibility of the shipper IMPORTANT No replacements credits or refunds will be issued for merchandise damaged in transit 5 ALL returns should be shipped to the ADC factory in such a manner that they are ensured and a proof of delivery can be obtained by the sender 6 Shipping charges are not the responsibility of ADC ALL returns should be prepaid to the factory Any C O D or COLLECT returns will not be accepted IMPORTANT No replacements credits or refunds will be issued if the claim cannot be processed due to insufficient information The party filing the claim will be notified in writing either by FAX or CERTIFIED MAIL Return Receipt Requested as to the
23. b timent e vacuez la pi ce le b timent ou la zone e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur e Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies Linstallation et l entretien doivent tre assures par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 USA Telephone 1 508 678 9000 Fax 1 508 678 9447 e mail techsupport amdry com www amdry com ADC Part No 113344 9 Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering design and safety If this product is properly maintained it will provide many years of safe efficient and trouble free operation ONLY qualified technicians should service this equipment OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer The following FOR YOUR SAFETY caution must be posted near the dryer in a prominent location FOR YOUR SAFETY POUR VOTRE SECURITE Do not store or use gasoline Ne pas entreposer ni utiliser d essence or other flammable vapors ni d autres vapeurs ou liquides and liquids in the vicinity of inflammables proximit de cet this or any other appliance appareil ou de tout autre apparei
24. ches 8 7 mb for natural gas and 10 5 inches 26 1 mb for L P dryers is required at the gas valve pressure tap of each dryer for proper and safe operation 20 American Dryer Corp 113344 9 A 1 8 N P T plugged tap accessible for a test gauge connection must be installed in the main gas supply line immediately upstream of each dryer IMPORTANT The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa NOTE The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa TYPICAL NATURAL GAS INSTALLATION GAS SERVICE LINE TAP 113344 9 www amdry com 21 H STEAM INFORMATION Itis your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that the installation is adequate and conforms to local and state regulations or codes IMPORTANT Failure to comply with the requirements stipulated in this manual can result in component failure which will VOID THE WARRANTY NOTE The dryer is manufactured with a pneumatic piston damper system which requires an external supply of clean dry and regulated air of 0 74 cfh a
25. ctwork is not critical as long as the minimum cross section area is provided IMPORTANT For a dryer that is vented horizontally the minimum duct size for a gas dryer is 14 inches 35 56 cm for a round duct or 12 1 2 31 75 cm for a square duct THE DUCT SIZE MUST NOT BE REDUCED ANYWHERE DOWNSTREAM OF THE DRYER IMPORTANT Exhaust back pressure measured by a manometer at each basket tumbler exhaust duct area must be no less than 0 and must not exceed 0 3 inches 0 74 mb of water column W C It is suggested that the ductwork from each dryer not exceed 15 feet 4 57 meters with no more than two 2 elbows excluding dryer connections and outside exhaust outlets If the ductwork exceeds 15 feet 4 57 meters or has numerous elbows the cross section area of the ductwork must be increased in proportion to the length and number of elbows in it In calculating duct size the cross section area of a square or rectangular duct must be increased by twenty percent 20 for each additional 15 feet 4 57 meters The diameter of a round exhaust duct should be increased ten percent 10 for each additional 15 feet 4 57 meters Each 90 elbow is equivalent to an additional 30 feet 9 14 meters and each 45 elbow is equivalent to an additional 15 feet 4 57 meters 113344 9 www amdry com 13 Va ia 1 HORIZONTAL DUCTING Pra 2 x D CLEARANCE L 4 A IMPORTANT For extended ductwork runs the cross section area of
26. e drying time and drying efficiency will be adversely affected Ignition problems and sail switch fluttering problems may result as well as premature motor failure from overheating Air supply make up air must be given careful consideration to assure proper performance of each dryer An unrestricted source of air is necessary for each dryer An airflow of 1 700 cfm 48 14 cmm must be supplied to each dryer As a general rule an unrestricted air entrance from the outdoors atmosphere of a minimum of 2 1 2 square feet 0 23 square meters is required for each dryer The dryer must be installed with provisions for adequate combustion and make up air supply me To compensate for the use of registers or louvers used over the openings the area must be increased by approximately thirty three percent 33 Make up air openings should not be located in an area directly near where exhaust vents exit the building It is not necessary to have separate make up air openings for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up air is distributed equally to ALL the dryers EXAMPLE For a bank of four 4 dryers two 2 unrestricted openings measuring 2 1 2 feet by 2 feet 0 76 meters by 0 61 meters are acceptable Allowances must be made for remote or constricting passagewa
27. e ADC Service Department at 1 508 678 9000 IMPORTANT A separate warranty card must be completed and returned for each individual dryer NOTE Be sure to include the installation date when returning the warranty card s B WARRANTY For a copy of the ADC commercial warranty covering your particular dryer s contact the ADC reseller from whom you purchased the equipment and request a dryer warranty form If the reseller cannot be contacted or is unknown warranty information can be obtained from the factory by contacting the ADC Warranty Department at 1 508 678 9000 NOTE Whenever contacting the ADC factory for warranty information be sure to have the dryer s model number and serial number available so that your inquiry can be handled in an expeditious manner C RETURNING WARRANTY PARTS ALL dryer or parts warranty claims or inquires should be addressed to the ADC Warranty Parts Department To expedite processing the following procedures must be followed 1 No parts are to be returned to ADC without prior written authorization Return Material Authorization R M A from the factory NOTE AnR M A is valid for only thirty 30 days from date of issue The R M A issued by the factory as well as any other correspondence pertaining to the returned part s must be included inside the package with the failed merchandise 113344 9 www amdry com 33 2 Each part must be tagged with the following inform
28. e that must be installed on the outlet of the exhaust before any further venting is connected To do this follow the procedures listed below a Remove the exhaust transition piece from the basket tumbler and place it on the exhaust outlet b Using the screws provided secure the exhaust transition piece to the dryer NOTE It is recommended that this joint be taped as well as ALL other duct joints to prevent moisture and lint from escaping into the building WARNING An exhaust duct transition piece is shipped inside of the dryer s tumbler and must be installed on the dryer s exhaust duct with the hardware provided BEFORE location venting is connected to the dryer THIS EXHAUST DUCT TRANSITION PIECE MUST BE INSTALLED FIRST Failure to observe this installation requirement may result in damage to the dryer create a FIRE HAZARD and will VOID the manufacturer s warranty 012999JEV GS cj P N 114092 2 Leveling Dryer The dryer is equipped with four 4 leveling legs one 1 at each comer of the dryer base Two 2 are located at the rear of the dryer base and two 2 are located in the lint chamber To increase bearing life and improve efficiency the dryer should be tilted slightly to the rear 113344 9 www amdry com 9 C DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible material NOTE Allowances must be made for o
29. ea where it will be exposed to water or weather The wiring diagram for the dryer is located in the front electrical control box area IMPORTANT Dryer must be installed in a location environment which the ambient temperature remains between 40 F 4 44 C and 130 F 54 44 C Table of Contents SECTION I SAFETY PRECATLION Sii A net red ends 2 SECTION II SPECIFICATIONS COMPONENT IDENTIFICATION sssssmnnnennennesnenennenee 4 SSPCCHPICATIONS 5 ie rte sheds nn ee Ne nn sansudbguadens ent ten mn le een Ne Ref int ie E dnd 4 B Component Identifica aiii tica drid ad Tada da dla test e 6 SECTION III INSTALLATION PROCEDURE Sois 8 A Location Requirements ii taa 8 B Wnpacking Settitig Wp inci a di iia 9 C Dryer Enclosure Requirement sise 10 D Fresh Air Supply Requirement sise 11 E Exhatist R quirements sanre e mn nest ai A le ele nates 12 F Electrical Information a 16 Gas InformMaAtON tibios Ina are dinde iaa idad 18 SIS A E ORO 22 I Fire Suppression System suisses 25 J Preparation for Operation Start Up sise 28 Ke Pre operational Test sn cial idas 29 E Preoperational Instruct OMs oeeie rs d pendent dune dd odeurs svt a EE E eE ET 31 M Shutdown Instructions ntsc en nn ne Te nt art et ets ner das ct 31 SECTION IV SERVICE PARTS INFORMATION csscscvsscsivessssssscsettiecenvensn cid ini adi Anido 32 A IS CLVIC CR A A A at ardid is 32 Bi Parita ia 32 SECTION V WARRANTY INFORMATION scsi decidi 33 A
30. equirements in Section E IMPORTANT Dryer should be located where a minimum amount of exhaust duct will be necessary 9 The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 months inspect the exhaust ducting and remove any lint buildup 8 American Dryer Corp 113344 9 B UNPACKING SETTING UP Remove protective shipping material 1 e plastic wrap and optional shipping box from dryer IMPORTANT Dryer must be transported and handled in an upright position at ALL times The dryer can be moved to its final location with or without the skid attached To unskid the dryer locate and remove the four 4 bolts securing the base of the dryer to the wooden skid Two 2 are located at the rear base remove the back panel for access and two 2 are located in the bottom of the lint chamber To remove the two 2 bolts located in the lint chamber area remove lint drawer completely Refer to page 37 for lint drawer removal instructions Once the bolts are removed and the lint drawer is reinserted slide the dryer off of the skid With the skid removed to make it easier to slide the dryer into its final position slightly lower ALL four 4 leveling legs so that the dryer will slide on the legs instead of the base frame 1 Inside the basket tumbler of this dryer is an exhaust transition piec
31. erials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct must be centered within this opening IMPORTANT It is recommended that exhaust or booster fans not be used in the exhaust ductwork system NOTE As per the National Fuel Gas Code Exhaust ducts for Type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge 0 0195 inches 0 5 mm thick 12 American Dryer Corp 113344 9 Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the ductwork travels vertically up through the roof it should be protected from the weather by using a 180 turn to point the opening downward In either case allow at least twice the diameter of the duct opening and the nearest obstruction MAN4 706 2 Single Dryer Venting When possible it is suggested to provide a separate exhaust duct for each dryer The exhaust duct should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible It is suggested that the use of 90 turns in the ducting be avoided use 30 and or 45 angles instead The shape of the exhaust du
32. ind the lint door in the base of the dryer Open the lint drawer brush the lint off of the lint screen and remove the lint Inspect the lint screen and replace if torn NOTE The frequency of cleaning the lint screens can best be determined from experience at each location WEEKLY Clean lint accumulation from the lint chamber thermostat and microprocessor temperature sensor sensor bracket area WARNING TOAVOID HAZARD OF ELECTRICAL SHOCK DISCONTINUE ELECTRICAL POWER SUPPLY TO THE DRYER STEAM DRYERS Clean the steam coil fins Suggest using compressed air and a vacuum cleaner with brush attachment 113344 9 www amdry com 35 NOTE When cleaning steam coil fins be careful not to bend the fins Ifthe fins are bent straighten by using a fin comb which is available from any local air conditioning supply house 90 DAYS 1 Remove lint from around basket tumbler drive motors and surrounding areas 2 Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment 3 Clean any lint accumulation in and around both the blower and drive motor casing openings EVERY 6 MONTHS Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer s internal exhaust ducting NOTE DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST DUCTWORK INSPECT AND REMOVE ANY LINT ACCUMULATION WHICH CAN CAUSE THE DAMPER TO
33. l We have tried to make this manual as complete as possible and hope you will find it useful ADC reserves the right to make changes from time to time without notice or obligation in prices specifications colors and material and to change or discontinue models The illustrations included in this manual may not depict your particular dryer exactly Important For your convenience log the following information DATE OF PURCHASE MODEL NO M L 82 RESELLER S NAME Serial Number s Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone your order directly to the ADC Parts Department at 1 508 678 9000 Please specify the dryer model number and serial number in addition to the description and part number so that your order is processed accurately and promptly IMPORTANT NOTE TO PURCHASER Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas These instructions must be posted ina prominent location near the dryer A WARNING Proposition 65 Use of this product could expose you to substances from fuel combustion that contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPL
34. lowing items should be checked before attempting to operate the dryer 1 2 10 11 12 13 14 28 Read ALL CAUTION WARNING and DIRECTION labels attached to the dryer Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label In the case of 208 VAC or 240 VAC the supply voltage must match the electric service exactly GAS MODELS Check to assure that the dryer is connected to the type of heat gas indicated on the dryer data label GAS MODELS The sail switch damper assembly was installed and adjusted at the factory prior to shipping However each sail switch adjustment must be checked to assure that this important safety control is functioning Refer to page 30 for Sail Switch Adjustment GAS MODELS Be sure that ALL gas shutoff valves are in the open position Be sure ALL side and base panels are on the dryer Check ALL service doors to ensure that they are closed and secure Be sure the lint drawer door is securely in place Rotate the basket tumbler drum by hand to be sure it moves freely Check bolts nuts screws terminals and fittings for security STEAM MODELS Check to ensure air supply 80 psi 5 51 bar is connected to the dryers STEAM MODELS Check to ensure ALL steam shutoff valves are open STEAM MODELS Check steam damper operation Check basket tumbler bearing setscrews to ensure they are ALL tight American Dryer Corp
35. mit is open prior to the start of the drying cycle or during the cycle the dryer will not recognize the open state of the burner hi limit and will start or continue through the drying cycle with no heat Manual reset hi limit must be reset manually This hi temperature condition may be caused due to a restricted exhaust poor airflow or improper burner operation The location of the burner hi limit is on the right side of the burner box looking at the burner from the back of the dryer IMPORTANT IMPORTANT IMPORTANTE HEATING UNIT IS EQUIPPED WITH A HI LIMIT THERMOSTAT WHICH MUST BE RESET MANUALLY WARNING DISCONTINUE POWER TO DRYER BEFORE ATTEMPTING TO RESET HI LIMIT L ELEMENT CHAUFFANT EST EQUIPE D UN THERMOSTAT A LIMITE MAXIMALE QUI DOIT TRE REGLE MANUELLEMENT MISE EN GARDE COUPER LE COURANT D ALIMENTATION DU SECHE LINGE AVANT DE REGLER LA LIMITE MAXIMALE LA UNIDAD DE CALENTAMIENTO ESTA EQUIPADA CON UN TERMOSTATO DE LIMITE SUPERIOR QUE DEBE REINICIALIZARSE MANUALMENTE ADVERTENCIA DESCONECTE LA ALIMENTACION ELECTRICA ALA SECADORA ANTES DE REINICIALIZAR EL LIMITE SUPERIOR ADC P N 114076 113344 9 www amdry com 41 American Dryer Corp ADC Part No 113344 9 09 04 08 15
36. must be centered within this opening Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the exhaust ductwork travels vertically up through the roof it should be protected from the weather by using a 180 turn to point the opening downward In either case allow at least twice the diameter of the duct between the duct opening and nearest obstruction 113344 9 www amdry com 15 HORIZONTAL DUCTING F ELECTRICAL INFORMATION 1 Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes In the absence of such codes ALL electrical connections materials and workmanship must conform to the applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Electrical Codes Parts 1 amp 2 CSA C22 1 1990 or LATEST EDITION IMPORTANT Failure to comply with these codes or ordinances and or the requirements stipulated in this manual can result in personal injury or component failure NOTE Component failure due to improper installation will VOID THE WARRANTY Each dryer should be connected to an independently protected
37. ny appliance b DO NOT touch any electrical switch c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f Ifyou cannot reach your gas supplier call the fire department 4 Installation and service must be performed by a qualified installer service agency or gas supplier 5 Dryer s must be exhausted to the outdoors 6 Although ADC produces a very versatile dryer there are some articles that due to fabric composition or cleaning method should not be dried in it WARNING Dry only water washed fabrics DO NOT dry articles spotted or washed in dry cleaning solvents a combustible detergent or all purpose cleaner EXPLOSION COULD RESULT WARNING DO NOT dry rags or articles coated or contaminated with gasoline kerosene oil paint or wax EXPLOSION COULD RESULT WARNING DO NOT dry mop heads Contamination by wax or flammable solvents will create a fire hazard WARNING DO NOT use heat for drying articles that contain plastic foam sponge rubber or similarly textured rubber materials Drying ina heated basket tumbler may damage plastics or rubber and may be a fire hazard 2 American Dryer Corp 113344 9 7 A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The f
38. ompany or the proper municipal authority for information regarding local codes IMPORTANT Itis your responsibility to have ALL plumbing connections made by a qualified professional to assure that the plumbing installation is adequate and conforms to local state and federal regulations or codes IMPORTANT It is the installer s or owner s responsibility to see that the necessary or required water water pressure pipe size or connections are provided Manufacturer assumes no responsibility if the fire suppression system is not connected installed or maintained properly 113344 9 www amdry com 25 1 Installation a Requirements The fire suppression system must be supplied with a minimum water pipe size of 1 2 and be provided with 40 psi 20 psi 2 75 bar 1 37 bar of pressure For use of optional manual bypass a second source with the same piping and pressure requirements is required Flexible 1 2 feeds must be provided to avoid damage to electric water solenoid valve by vibration IMPORTANT Flexible supply line coupling must be used Solenoid valve failure due to hard plumbing connections WILL VOID WARRANTY If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water lines from freezing WARNING Ifthe water in the supply line or water solenoid valve freezes the fire suppression system will be I
39. onal 15 feet 4 57 meters Each 90 elbow is equivalent to an additional 30 feet 9 14 meters and each 45 elbow is equivalent to an additional 15 feet 4 57 meters IMPORTANT For extended ductwork runs the cross section area of the ductwork can only be increased to an extent Maximum proportional ductwork runs cannot exceed 15 feet 4 57 meters more than the original limitations of 15 feet 4 57 meters with two 2 elbows When the ductwork approaches the maximum limits as noted in this manual a professional heating ventilating and air conditioning HVAC firm should be consulted for proper venting information IMPORTANT Exhaust back pressure measured by a manometer at each dryer exhaust duct area must be no less than 0 and must not exceed 0 3 inches 0 74 mb of water column W C The ductwork should be smooth inside with projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it is to be connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct
40. one by a qualified professional NOTE Undersized gas piping will result in ignition problems slow drying increased use of energy and can create a safety hazard The dryer must be connected to the type of heat or gas indicated on the dryer data label If this information does not agree with the type of gas available DO NOT operate dryer Contact the reseller who sold the dryer or contact the ADC factory IMPORTANT Any burner changes or conversions must be made by a qualified professional The input rating shown on the dryer data label is for elevations of up to 2 000 feet 609 6 meters unless elevation requirements of over 2 000 feet 609 6 meters were specified at the time the dryer order was placed with the factory The adjustment or conversion of dryers in the field for elevations over 2 000 feet 609 6 meters is made by changing each burner orifice If this conversion is necessary contact the reseller who sold the dryer or contact the ADC factory IMPORTANT THIS GAS DRYER IS NOT PROVIDED WITHAN INTERNAL GAS SUPPLY SHUTOFF AND AN EXTERNAL GAS SUPPLY SHUTOFF MUST BE PROVIDED 2 Technical Gas Data a Gas Specifications TYPE OF GAS NATURAL LIQUID PROPANE Manifold Pressure 3 5 inches W C 8 7 mb 10 5 inches W C 26 1 mb In Line Pressure 6 0 12 0 inches W C 14 92 29 9 mb 11 0 inches W C 27 4 mb Shaded areas are stated in metric equivalents Measured at gas valve pre
41. ordinances In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI Z223 1 LATEST EDITION or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing 1 The dryer must be installed on a sound level floor capable of supporting its weight Carpeting must be removed from the floor area that the dryer is to rest on IMPORTANT The dryer must be installed on noncombustible floors only 2 The dryer must not be installed or stored in an area where it will be exposed to water and or weather 3 The dryer is for use in noncombustible locations 4 Provisions for adequate air supply must be provided as noted in this manual refer to Fresh Air Supply Requirements in Section D 5 Clearance provisions must be made from combustible construction as noted in this manual refer to Dryer Enclosure Requirements in Section C 6 Provisions must be made for adequate clearances for servicing and for operation as noted in this manual refer to Dryer Enclosure Requirements in Section C 7 The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual refer to Exhaust Requirements in Section E 8 Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust R
42. pening the control door Yaw TT SSNS y Y A B L C N XC 40 inches 101 6 cm for optimum opening of load door The maximum thickness of the bulkhead is 4 inches 10 16 cm For electric dryers the maximum thickness of the bulkhead is 1 inch 2 54 cm within 3 inches 7 62 cm from the top of the control door For gas and electric dryers a minimum overhead clearance of 12 inches 30 48 cm is required providing no sprinkler is located above the dryer For steam dryers or if a sprinkler is located above the dryer 18 inches 45 72 cm is required Dryer should be positioned 12 inches 30 48 cm away from the nearest obstruction and 24 inches 60 96 cm is recommended for ease of installation maintenance and service 2 inch 5 08 cm minimum is required for opening the control door Flooring should be level or below dryer cabinet for ease of removing panels during maintenance Dryers may be positioned sidewall to sidewall however a 1 16 1 5875 mm minimum allowance must be made for the opening and closing of the control door along with the removal of panels during maintenance American Dryer Corp 113344 9 D FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating it draws in room air heats it passes this air through the basket tumbler and exhausts it out of the building Therefore the room air must be continually replenished from the outdoors Ifthe make up air is inadequat
43. requency of inspection and cleaning can best be determined from experience at each location WARNING The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard 8 For personal safety the dryer must be electrically grounded in accordance with local codes and or the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Electrical Codes Parts 1 amp 2 CSA C22 1 1990 or LATEST EDITION NOTE Failure to electrically ground the dryer properly will VOID THE WARRANTY 9 UNDER NO CIRCUMSTANCES should the dryer door switch lint drawer switch or heat safety circuit ever be disabled WARNING PERSONAL INJURY OR FIRE COULD RESULT SHOULD THE DRYER DOOR SWITCH LINT DRAWER SWITCH OR HEAT SAFETY CIRCUIT EVER BE DISABLED 10 This dryer is not to be used in the presence of dry cleaning solvents or fumes 11 Remove articles from the dryer as soon as the drying cycle has been completed WARNING Articles left in the dryer after the drying and cooling cycles have been completed can create a fire hazard 12 READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE DRYER 13 For safety proper operation and optimum performance the dryer must not be operated with a load less than sixty six percent 66 53 lb 24 04 kg of its rated capacity WARNING YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS
44. rovide separate exhaust ducts for each dryer ducts from individual dryers may be channeled into a common main duct The individual ducts should enter the bottom or side of the main duct at an angle not more than 45 in the direction of airflow and should be spaced at least 38 1 4 97 15 cm apart The main duct should be tapered with the diameter increasing before each individual duct 14 inch 35 56 cm minimum for gas models and 16 inch 40 64 cm minimum for steam models is added American Dryer Corp 113344 9 IMPORTANT No more than four 4 dryers should be connected to one 1 main common duct The main duct may be any shape so long as the minimum cross sectional area is provided The illustration on page 16 shows the minimum cross section area for multiple dryer round or square venting These figures must be increased 10 square inches 64 52 squares centimeters when rectangular main ducting is used and the ratio of duct width to depth should not be greater than 3 1 2 to 1 These figures must be increased in proportion if the main duct run to the last dryer to where it exhausts to the outdoors is unusually long over 15 feet 4 57 meters or has numerous more than two 2 elbows init In calculating ductwork size the cross section area of a square or rectangular duct must be increased twenty percent 20 for each additional 15 feet 4 57 meters The diameter of a round exhaust must be increased ten percent 10 for each additi
45. s describes the type of heat for your particular dryer gas either natural gas or liquid propane L P gas electric or steam 5 HEAT INPUT for GAS DRYERS This describes the heat input in British thermal units per hour Btu hr 6 ORIFICE SIZE for GAS DRYERS Gives the number drill size used 7 ELECTRIC SERVICE This describes the electric service for your particular model 8 GAS MANIFOLD PRESSURE for GAS DRYERS This describes the manifold pressure taken at the gas valve tap 40 American Dryer Corp 113344 9 SECTION IX MANUAL RESET BURNER HI LIMIT INSTRUCTIONS A PHASE 7 This dryer was manufactured with a manual reset burner hi limit thermostat which is monitored by the Phase 7 computer Ifthe burner hi limit is open prior to the start of the drying cycle the dryer will start momentarily and then shut down the Phase 7 computer will display BURNER HIGH LIMIT FAULT with an audio indication If the burner hi limit opens during a drying cycle the Phase 7 computer will also display the same error code described above along with an audio indication If the drum temperature is above 100 F 38 C the dryer will continue to run with no heat for 3 minutes or until the drum temperature has dropped below 100 F 38 C The clear stop button on the Phase 7 keypad must be pressed to clear the error condition B DUAL TIMER This dryer was manufactured with a manual reset burner hi limit thermostat If the burner hi li
46. s ductwork must be at least 14 inches 35 56 cm In the case of multiple common dryer venting the distance from the last dryer to the outside exhaust outlet must not exceed 15 feet 4 57 meters The shape of the ductwork is not critical as long as the minimum cross sectional area is provided It is suggested that the use of 90 turns be avoided use 30 and or 45 angles instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct Including basket tumbler and dryer elbow connections or elbows used for outside protection from the weather no more than two 2 elbows should be used in the exhaust duct run If more than two 2 elbows are used the cross sectional area of the ductwork must be increased ALL ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it is to be connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork IMPORTANT Exhaust back pressure measured by a manometer in the exhaust duct must be no less than 0 and must not exceed 0 3 inches 0 74 mb of water column W C NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible mat
47. s in the supply line caused by low points will provide wet steam to the coil possibly causing coil damage ALL horizontal runs of steam supply piping should be pitched 1 4 inch 6 35 mm for every 1 foot 0 30 meters back toward the steam supply header causing any condensate in the line to drain to the header Install a bypass trap in any low point to eliminate wet steam 3 Steam Damper Air System Connections The dryer is manufactured with a pneumatic piston damper system which requires an external supply of compressed air The air connection is made to the steam damper solenoid valve which is located at the rear inner top area of the dryer just above the electric service relay box 113344 9 www amdry com 23 a Air Requirements PE Air Pressure Normal 80 psi 5 51 bar Minimum Supply 70 psi 4 82 bar Maximum Supply 90 psi 6 21 bar Shaded areas are stated in metric equivalents b Air Connection Air connection to system 1 8 N P T c Air Regulation No air regulation or filtration is provided with the dryer External regulation and filtration of 0 75 cfh at 80 psi 0 02 cmh at 5 51 bar must be provided It is suggested that a regulator or filter gauge arrangement be added to the compressed air line just before the dryer connection This is necessary to ensure that correct and clean air pressure is achieved 4 Steam Damper System Operation The steam damper as shown in the ill
48. s materials must conform to National Fuel Gas Code Specifications ANSI Z223 1 LATEST EDITION or in Canada CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing as well as local codes and ordinances and must be done by a qualified professional It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of ALL the appliance Btu being supplied The dryer is provided with a 1 N P T inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 diameter For ease of servicing the gas supply line of each dryer must have its own shutoff valve The size of the main gas supply line header will vary depending on the distance this line travels from the gas meter or in the case of L P gas the supply tank other gas operated appliances on the same supply line etc Specific information regarding supply line size should be determined by the gas supplier Consistent gas pressure is essential at ALL gas connections It is recommended that a 1 inch 2 54 cm pipe gas loop be installed in the supply line servicing a bank of dryers An in line pressure regulator must be installed in the gas supply line header if the natural gas pressure exceeds 12 0 inches 29 9 mb of W C pressure IMPORTANT Aconsistent W C pressure of 3 5 in
49. s with Direct Spark Ignition DSI Module Type I Theory of Operation Start the drying cycle When the gas burner ignites within the chosen trial for ignition time 6 seconds the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat The DSI module will LOCKOUT if the gas burner flame is not sensed at the end of the trial for ignition period The trial for ignition period will be repeated for a total of three 3 retries trials the initial try and two 2 more retries trials If the flame is not sensed at the end of the third retry trial inter purge period of 30 seconds the DSI module will LOCKOUT light emitting diode L E D diagnostic indicator flashes A steady L E D indicator indicates normal operation No L E D indicator indicates a power or an internal failure has occurred 3 For Models with DSI Module Type II Theory of Operation Start the drying cycle When the gas burner ignites within the chosen trial for ignition time 8 seconds the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat The DSI module will LOCK OUT if the gas burner flame is not sensed at the end of the trial for ignition period The trial for ignition period will be repeated for a total of three 3 retries trials the initial try and two 2 more retries trials If
50. ssure tap when gas valve is on b Gas Connections Inlet connection 1 N P T Inlet supply size 1 Diameter Pipe minimum Btu hr input 270 000 68 040 kcal hr 113344 9 www amdry com 19 1 Natural Gas Regulation is controlled by the dryer s gas valve s internal regulator Incoming supply pressure must be consistent between a minimum of 6 0 inches 14 92 mb and a maximum of 12 0 inches 29 9 mb water column W C pressure 2 Liquid Propane L P Gas Dryers made for use with L P gas have the gas valve s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer The pressure measured at each gas valve pressure tap must be a consistent 10 5 inches 26 1 mb W C There is no regulator or regulation provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be added to each dryer TYPE OF GAS Liquid a Propane Btu hr kcal hr Natural Liquid Propane Conversion Kit Rating Rating Qty D M S PartNo Qty D M S PartNo Part Number 270 000 68 040 4 23 140856 4 41 140811 882119 Shaded area is stated in metric equivalent Drill Measurement Size D M S equivalents are as follows Natural Gas 23 0 154 3 9116 mm Liquid Propane Gas 41 0 096 2 4384 mm 3 Piping and Connections ALL component
51. t 80 psi 10 psi 0 02 cmh at 5 51 bar 0 68 bar Refer to Steam Damper Air System Connections Section H item 3 IMPORTANT STEAM pH LEVEL The normal pH level for copper type steam coils must be maintained between a value of 8 5 to 9 5 For steel type steam coils the pH level must be maintained between a value of 9 5 and 10 5 These limits are set to limit the acid attack of the steam coils NOTE Coil failure due to improper pH level will VOID THE WARRANTY 1 Steam Requirements High Pressure a Inlet 1 supply line connection qty one 1 at top manifold b Return 1 return line connection qty one 1 at bottom manifold Operating Steam Pressure Maximum 125 psig 861 84 kPa Heat Input Normal Load 11 Bhp Consumption Approximate 375 lbs hr 170 5 kg hr Shaded areas are stated in metric equivalents The minimum operating pressure for optimum results is 100 psig 689 47 kPa 2 Installation Instructions To ensure an adequate supply of steam is provided be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure Clean dry and regulated steam must be provided to the dryer a The pressure of the condensate in the steam supply will cause water hammer and subseq
52. uent heat exchanger steam coil failure The steam supply connection into the main supply line must be made with a minimum 12 inch 30 48 cm riser This will prevent any condensate from draining towards the dryer b The steam supply line to the dryer must include a 12 inch 30 48 cm riser along with a drip trap and check valve This will prevent any condensate from entering the steam coil 22 American Dryer Corp 113344 9 c Flexible hoses or couplings must be used The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains d Shutoff valves for each dryer should be installed in the supply return and drip trap return lines This will allow the dryer to be isolated from the supply and return mains if the dryer needs maintenance work e Install an inverted bucket steam trap and check valve for each unit at least 12 inches 30 48 cm below steam coil as close to the coil as possible a trap with a capacity of 1 000 lb 454 kg of condensate per hour at 125 psi 8 62 bar is needed for each unit f A 3 4 inch 19 05 mm vacuum breaker should be installed for each unit in the piping This will prevent the condensing steam from causing a vacuum inside the coil and possibly damaging the coil g The supply and return lines should be insulated This will save energy and provide for the safety of the operator and maintenance personnel h Water pocket
53. ustration below allows the coil to stay constantly charged eliminating repeated expansion and contraction When the damper is opened the air immediately passes through the already hot coil providing instant heat to start the drying process When the damper is closed ambient air is drawn directly into the basket tumbler allowing a rapid cool down Diagram 1 shows the damper in the heating open mode allowing heat into the basket tumbler Diagram 2 shows the damper in the cool down closed mode pulling ambient air directly into the basket tumbler without passing through the coils we N Diagram 1 LAC NS Airflow Diagram 2 Heating Mode Airflow Airflow MANO595 Cool Down Mode 24 American Dryer Corp 113344 9 5 Steam Damper Air Piston Flow Control Operation Adjustment Although the damper operation was tested and adjusted prior to shipping at 80 psi 5 51 bar steam damper operation must be checked before the dryer is put into operation Refer to page 29 for instructions to check steam damper operation If damper air adjustment is necessary locate flow control valve and make necessary adjustments as noted below MAN5223 I FIRE SUPPRESSION SYSTEM BEFORE YOU START CHECK LOCAL CODES AND PERMITS Call your local water c
54. ys or where dryers are located at excessive altitudes or predominantly low pressure areas IMPORTANT Make up air must be provided from a source free of dry cleaning solvent fumes Make up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components NOTE Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY 113344 9 www amdry com 11 E EXHAUST REQUIREMENTS 1 General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional Improperly sized ductwork will create excessive back pressure which results in slow drying increased use of energy overheating of the dryer and shut down of the burner by the airflow sail switches burner hi limits or basket tumbler hi heat thermostats The dryer must be installed with a proper exhaust duct connection to the outside CAUTION This dryer produces combustible lint and must be exhausted to the outdoors CAUTION IMPROPERLY SIZED OR INSTALLED EXHAUST DUCTWORK CAN CREATE A POTENTIAL FIRE HAZARD The ductwork should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible Single or independent dryer venting is recommended When single dryer venting is used the length of ductwork from the dryer to the outside exhaust outlet must not exceed 15 feet 4 57 meters The minimum diameter of thi

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com 3 ft DVI to VGA Display Monitor Cable  Hyundai D460ML  030072_Manual Combinado Eletronico Programável.cdr  Alpatronix HX100 User's Manual  SERIE SJ700B - Hitachi Industrial Components & Equipment Group  BENDIX BW1442 User's Manual  Questions du questionnaire à l`intention des répartiteurs    FRE - Carel  Massive Spot light 54080/11/10  