Amana NED4705EW Dimension Guide
Contents
1. Electric Dryer PRODUCT MODEL NUMBERS NED4600Y NED4700Y NED4655E NED4705E Amana Installation clearances The location must be large enough to allow the dryer door to open fully Minimum spacing for recessed area or closet installation Dryer Dimensions Minimum Required Spacing 22 43 1102 mm 96 T 578 mm Te 43 1102 mm Tl 705 mm ait a Ne mL Timm 737 mm B A Recessed area B Side view closet or confined area C Closet door with vents 43h 43 1102 mm 1102 mm AO 99 N 737 mm D Most installations require a minimum 5 2 140 mm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Additional spacing recommended 2PX 705 mm Installation spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed m Additional spacing should be considered for ease of installation and servicing m Additional clearances might be required for wall door and floor moldings m Additional spacing of 1 25 mm on all sides of the dryer is recommended to reduce noise transfer m For closet installation with a door minimum ventilation
2. openings in the top and bottom of the door are required Louvered doors with equivalent ventilation opening are acceptable E Companion appliance spacing should also be considered W10514172A 02 2015 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit VENTING REQUIREMENTS Exhaust venting Exhaust your dryer to the outside 4 102 mm The Vent System Chart provides venting requirements that will diameter vent is required Rigid or flexible metal exhaust vent help achieve best drying performance must be used Do not use plastic or metal foil vet Exhaust hood must be at least 12 805 mm from the ground or any object that Vent System Chart may be in the path of the exhaust Number of Type Box louvered Exhaust hoods 90 turns of vent hoods or elbows Recommended Styles TA a Rigid metal 54 ft 16 5 m 48 ft 14 6 m oao Rigid metal 44 ft 13 4 m 38 ft 11 6 m Louvered Hood Box Hood 8 Rigid metal 35 ft 10 7 m 29 ft 8 8 m Acceptable Style Rigid metal 27 ft 8 2 m 21 ft 6 4 m CRA Vent System Chart Long Vent Models Only Number of Type Box louvered or Angled Hood 90 turns of
3. vent Angled hoods or elbows Determine vent path Rigid metal 120 ft 36 6 m E Select route that will provide straightest and most direct path outdoors Rigid metal 110 ft 33 5 m m Plan installation to use fewest number of elbows and turns pk Rigid metal 100 ft 30 5 m m When using elbows or making turns allow as much room as possible ee Rigid metal 90 ft 27 4 m m Bend vent gradually to avoid kinking m Use as few 90 turns as possible a Rigid metal 80 ft 24 4 m Determine vent length and elbows needed for best oso Rigid metal 70 ft 21 3 m drying performance m Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use NOTE Bottom exhaust installations have a 90 turn inside the dryer To determine maximum exhaust length add one 90 turn to the chart NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will m Shorten life of dryer m Reduce performance resulting in longer drying times and increased energy usage Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice
Download Pdf Manuals
Related Search
Related Contents
LG V909 User's Manual Samsung ST10 User Manual Summer Infant 07030A User's Manual Copyright © All rights reserved.
Failed to retrieve file