Home

Allied Telesis Rapier Switch User's Manual

image

Contents

1. is within the acceptable range Fault Red The switch or management software is malfunctioning 1 flash A switch fan has failed The LEDs will not indicate an RPS fan failure 3 flashes If an RPS is connected the switch s PSU Power Supplv Unit has failed 4 flashes If RPS monitoring is enabled the RPS PSU has tailed 5 flashes If RPS monitoring is enabled an RPS is not connected or is not operational RPS Redundant Green An RPS is connected to the switch Power Supply In use Rear panel Green An NSM is installed is receiving power and is operational The NSM and its PICs are not ready to be hot swapped Off No NSM is installed or the NSM is not installed correctly the switch unit has not recognised the NSM Swap Rear panel Green The NSM and its PICs are ready to be hot swapped Off The Hot Swap button must be pressed before the NSM or PICs can be hot swapped or the software release does not support hot swapping 1 DC models of the Rapier Switch do not have an RPS connector and the RPS LED will not function 2 Not included on the Rapier 48 G6 G6F SX SC G6F LX SC or G6F SX MT RJ 3 Hot swapping is supported by Software Release 2 3 1 or later AT ARO21 S BRI S T AT ARO21 U BRI U AT ARO22 ETH AT ARO23 SYN and AT ARO26 4ETH PICs can be hot swapped The Rapier Switch Hardware Reference has further troubleshooting information including information on Switch Port and Uplink Module LEDs Software Release
2. on Uplink Modules AT TFIP Server for Windows for downloading software releases Adobe Acrobat Reader for viewing online documentation Netscape Communicator Microsoft Internet Explorer
3. the terminals to between 0 6 and 0 8 Nm 0 041 to 0 055 pound force per foot e Ensure that there are no exposed conductor strands f Secure the supply cable to the rack framework or similar object so that the connections are isolated from any forces applied to the cable g Ensure that the circuit breaker is in the Off position h Connect the supply cable wires to the circuit breaker i Energise the circuit breaker Figure 2 DC Power inlet terminals on a Rapier 24 rowercomecron Al i i A resrucreo anea A lt AN AM zi 4 DC INPUT 38 75VDC 2A m NSM 0 0 Swap In Use Hot swap DC Power inlet Software Release 2 3 1 C613 04017 01 REV D 10 11 The Fault LED should flash for approximatelv 10 seconds as the switch runs internal tests If the LED continues to flash or remains lit refer to the Rapier Switch Hardware Reference for troubleshooting information Check that the Power LED on the switch s front panel lights green If the LED fails to light refer to the Rapier Switch Hardware Reference for troubleshooting information Connect the Redundant Power Supply Optional AC models of Rapier Switches have a Redundant Power Supply RPS connector on their rear panel The Switch is designed to operate with the AT PWR8000 RPS which can be purchased separately Contact your authorised Allied Telesyn distributer or reseller for more information Connect the data c
4. 2 3 1 C613 04017 01 REV D Quick Install Guide Software Release 2 3 1 C613 04017 01 REV D 11 Documentation and Tools CD ROM The Documentation and Tools CD ROM bundled with each Rapier Switch contains the complete Documentation Set for Rapier Switches and their expansion options as well as tools for managing the switch This includes m The Rapier Switch Safety Booklet which provides safety and statutory information for the Rapier Switch and its expansion options E The Rapier Switch Hardware Reference which provides detailed information on the hardware features of Rapier Switches This Quick Install guide The Rapier Switch Software Reference which provides detailed information on configuring the switch and its software E The Rapier Switch User Guide which provides an introduction to the switch s Graphical User Interface and its Layer 2 switching features E The Network Service Module Quick Install Guide which outlines the procedure for installing an NSM and the Network Service Module Hardware Reference which provides detailed information on NSMs E The Port Interface Card Quick Install Guide which outlines the procedure for installing PICs and the Port Interface Card Hardware Reference which provides detailed information on PICs E The Uplink Module Quick Install Guide which outlines the procedure for installing an Uplink Module and the Uplink Module Hardware Reference which provides detailed information
5. PS Inlet for NSM BAY NSM Hot Swap Power Inlet AT PWR8000 Button and LEDs 8 Applv DC power to the switch for DC models Read the Safety and Statutory Information booklet before connecting a DC power supply A copy of this booklet is included with each switch It is also included on the Documentation and Tools CD ROM or can be downloaded from wwwaalliedtelesvn co nz support rapier Only trained and qualified personnel should connect a DC power supply Due to exposed terminals DC powered switches should only be installed in Restricted Access Areas DC supply cable specifications e Number of wires cores 3 e Minimum size 2 1mm 14 AWG e Minimum cable rating 600V 90 degrees Celsius DC power supply specifications e 48 V DC 39 60 V DC is acceptable e Either positive grounded or negative grounded Circuit protection e Usea 10 Amp circuit breaker To connect the DC supply a Ensure that the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c Atthe switch connect the ground wire to the ground terminal The terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0 055 pound force per foot Software Release 2 3 1 C613 04017 01 REV D Quick Install Guide d Atthe switch connect the positive feed to the positive terminal and the negative feed to the negative terminal Tighten
6. QUICK INSTALL GUIDE Rapier Switch Quick Install Guide Document Number C613 04017 01 REV D Copvright O 1999 2002 Allied Telesvn International Corp 19800 North Creek Parkwav Suite 200 Bothell WA 98011 USA All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesyn Allied Telesyn International Corp reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesyn has been advised of known or should have known the possibility of such damages All trademarks are the property of their respective owners Quick Install Guide Documentation Roadmap Network Service Modules E NSM Quick Install Guide sena wee wn Uplink Module Uplink Module Quick Install Guide E Uplink Module Hardware Reference Rapier Switch E Safety and Statutory Information Quick Install Guide Hardware Reference E Software Reference E User Guide mil Printed Acrobat PDF WON Website BA NSM Hardware Reference Port Interface Cards PIC Quick Install G
7. ables Make sure that each cable connection is secure The switch will now perform basic Layer 2 switching functions Configuring the switch Some configuration is necessary if you wish to enable the switch s advanced switching capabilities The switch can be configured via the Command Line Interface CLI or Graphical User Interface GUI Using the CLI to configure a switch 1 Connect a terminal or PC to the Terminal Port ASYNO Using the supplied RS 232 DB9 straight through cable connect your terminal or PC to the RS 232 Terminal Port on the switch s front panel Rapier Switch 2 Setthe communication parameters Set the communication parameters on your terminal or terminal emulation program to e Baud rate 9600 e Data bits 8 e Parity None e Stop bits 1 e Flow control Hardware 3 Login After the switch has booted the log in prompt appears If the log in prompt doesn t appear press Enter two or three times When the switch boots for the first time it automatically creates an account with manager privileges The account has the log in name manager and the password is friend At the log in prompt enter the log in name and password Log in manager Password friend The switch s command prompt appears and you can now configure the switch using the command line interface Change the password as soon as possible Leaving the manager account with the default password is a serious sec
8. ble site for the switch Either a flat surface or 19 inch rack Unpack the switch Verify the package contents If any items are damaged or missing contact your sales representative Install expansion options If you purchased optional Uplink Modules a Network Service Module NSM or Port Interface Cards PICs install them now by following their individual installation guides These guides can be found on the Documentation and Tools CD ROM Installation instructions for PACs can be found in the Rapier Switch Hardware Reference Place the switch in its operating locations If installing the switch in a rack e Remove the rubber feet e Attach the rack mounting brackets e Mount the switch in the rack Apply AC power to the switch for AC models Plug the power cord into the AC power connector on the switch s rear panel The Fault LED should flash for approximately 10 seconds as the switch runs internal tests If the LED continues to flash or remains lit refer to the Rapier Switch Hardware Reference for troubleshooting information Rapier Switch Figure 1 Rapier front panel and rear panel with AC power inlet Front panel Rear panel Uplink Module Bavs 10 100 BASE Expansion Bavs Port LEDs Svstem RS 232 Terminal Port A A a gt NSM 0 _ Swap In Use Hot Swap 100 240 VAC R
9. o 40 C 32 to 104 F and a humidity range of 5 to 95 non condensing Has a reliable and earthed grounded preferably dedicated and filtered power supply circuit Does not expose cabling to sources of electrical noise such as radios transmitters broadband amplifiers power lines electric motors and fluorescent fixtures Allows easy access to the switch s power and cable connections Will allow all related network devices to be connected to the switch without exceeding maximum cable length limitations See the Rapier Switch Hardware Reference for cable length specifications Software Release 2 3 1 C613 04017 01 REV D Quick Install Guide Installing the Switch A All AC and DC versions of this equipment must be earthed Follow these steps to install the switch 1 Software Release 2 3 1 C613 04017 01 REV D Before installing the switch read the safety information For safety information see the Safety and Statutory Information booklet A copy of this booklet is supplied with each switch and can also be found on the Documentation and Tools CD ROM or at www alliedtelesyn co nz support rapier Gather the tools and equipment you will need If installing a DC version of the switch you will need a DC power source DC supply cable and wire strippers see step 8 If the switch is to be connected to a redundant power supply you will need a redundant power supply unit and cable see step 10 Choose a suita
10. ter ADD IP ROUTE PC ipaddress INTERFACE vlanl NEXTHOP switch ipaddress Connect the PC to a switch port The PC can be connected directly or through a LAN The PC should be running Internet Explorer 5 x or Netscape 6 2 with JavaScript enabled A copv of Internet Explorer can be found on the Documentation and Tools CD ROM that is bundled with vour switch If you access the Internet through a proxy server set your browser to bypass the proxy for the IP address you just assigned to the VLAN1 interface Point your web browser at the IP address of the VLAN interface Log in At the log in prompt enter the log in name and password User Name manager Password friend The system status page appears and you can now use the GUI to configure the switch LE To ensure that configuration settings are saved correctly use the GUI pages menus and buttons to navigate not your browser s buttons A As a security precaution change the password as soon as possible Software Release 2 3 1 C613 04017 01 REV D To change the password select Management gt Users from the sidebar menu Select the Manager account and click Modify To access context sensitive help Click on the GUI Assistant Button on each page 10 Rapier Switch Svstem LEDs and What Thev Mean Svstem LEDs on its front panel indicate the switch s operational status Svstem LEDs LED State Function Power Green The switch is receiving power and the voltage
11. uide E PIC Hardware Reference General Customer Support I y O Visit www alliedtelesyn co nz for the latest documentation FAQ and support information Models Covered By This Guide This Quick Install Guide includes information on the following models Rapier G6 Rapier G6F LX SC Rapier G6F SX SC Rapier G6F SX MT RJ Rapier 8 8MT Rapier 8 8SC Rapier 16F FX MT Rapier 16F FX SC Rapier 24 Rapier 241 Rapier 48 Rapier 481 Quick Install Guide updates can be downloaded from www alliedtelesvn co nz support rapier Software Release 2 3 1 C613 04017 01 REV D Rapier Switch Package Contents The following items are included with each Rapier Switch Contact vour sales representative if anv items are damaged or missing One Rapier Switch One AC power cord AC models only One serial cable for connecting the switch to a terminal or PC One 19 inch rack mount kit One Rapier Switch Quick Install Guide One Safety and Statutory Information booklet One Rapier Switch Documentation and Tools CD ROM which includes the complete Rapier Document Set and utilities One warranty card Selecting a Site The switch can be installed in a standard 19 inch rack or on a level surface such as a desktop or bench When installing the switch choose a site that Allows adequate airflow around the switch and its vents Is free of dust and moisture Will allow the switch to operate within a temperature range of 0 t
12. urity risk Make sure that you remember the new password as there 1s no way to retrieve tt if it is lost Use the following command to change the account password set password 4 Load help files To access help enter set help help filename where heip filename is the name of a help file stored in flash To see a list of files stored in flash enter show file Help files have an HLP extension To displav a list of help topics enter help To display help on a specific topic enter help topic Alternatively type a question mark at the end of a partially completed command to see a list of valid options See the Rapier Switch Software Reference for more information on configuring the switch Software Release 2 3 1 C613 04017 01 REV D Quick Install Guide Using the GUI to configure a switch The GUI can be accessed through the switch s default VLAN VLAN1 To set up the GUI the first time it is used you must first access the CLI Access the CLI Follow the instructions in the previous section Using the CLI to configure a switch Enable IP At the CLI enter the command ENABLE IP Assign an IP address to VLAN1 Assign the VLANI interface an IP address in the required subnet using the command SET IP INTERFACE vlanl IP ipaddress MASK mask Define a route if required If the PC from which you will access the GUI is on a different subnet to the switch add a route from the PC to the switch En

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SES-Q40 User Manual  DC 入力セットモデル・ドライバ  Mostrar - Service, Support  Intenso Memory Space, 1TB  Paxar Monarch 9805 Thermal Label Printer  Mode d`emploi : Additif de rinçage L`additif MICROSTOP  LST AO-55000-620 User's Manual  Réunion d`information Admission postbac Réunion d`information  Liebherr HC-1060 Premium Plus Series 24" Built-in Fully  overview of subworkflow sketches  