Alliance Laundry Systems LGS19A User's Manual
Contents
1. gt 43 109 2 cm 23 5 28 59 7 71 1 3 8 NPT GAS CONNECTION WITH LEVELING LEGS TURNED INTO BASE D313IE3A GAS DRYERS 504607 Before You Start Tools For most installations the basic tools you will need are WRENCH SCREWDRIVERS lt gt TEFLON Exhaust Use rigid metal duct and exhaust the dryer to the outside by the shortest route possible D314IE0A NOTE For more detailed information refer to Section on Dryer Exhaust Requirements Electrical e ELECTRIC DRYER Dryer needs a 3 or 4 wire 120 240 Volt 30 Amp 60 Hertz 1 Phase electrical supply e GAS DRYER Dryer needs a 120 Volt 15 Amp 60 Hertz polarized 3 slot effectively grounded receptacle NOTE For more detailed information refer to Section on Electrical Requirements Gas Dryer is equipped for Natural Gas with a 3 8 NPT gas supply connection For more detailed information refer to Section on Gas Requirements Location Place the dryer on a solid floor with an adequate air supply For more detailed information refer to Section on Location Requirements 504607 Installing the Dryer Step 1 Position and Level the Dryer For further assistance refer to Section on Location Requirements Install drye
2. CON LAS PATAS DE NIVELACION ENROSCADAS EN LA BASE SECADORAS A GAS CONEXION DE GAS NPT DE 3 8 plg D3131S3A 26 504607 SP Antes de comenzar Herramientas Estas son las principales herramientas que necesitar en la mayor a de las instalaciones LLAVE DE TUERCAS lt gt CINTA DE TEFL N 00741518 CINTA DUCTOS Ducto de escape Utilice un ducto met lico r gido y use la ruta m s corta posible para el escape de la secadora D314IE0A NOTA Para obtener m s detalles consulte la secci n Requisitos de escape de la secadora 504607 SP Requisitos el ctricos SECADORA EL CTRICA La secadora necesita una fuente de suministro de energ a el ctrica monof sica de 3 6 4 terminales de 120 240 voltios 60 Hz 30 Amperios e SECADORA A GAS Necesita un recept culo de 3 ranuras polarizado debidamente conectado a tierra de 120 voltios 60 Hz 15 Amperios NOTA Para obtener m s detalles consulte la secci n Requisitos el ctricos Requisitos de gas La secadora viene equipada con un tubo de conexi n de gas NPT de 3 8 pulgadas para trabajar con gas natural V ase la secci n Requisitos de gas para obtener m s informaci n Ubicaci n Coloque la secadora sobre un piso firme y en un lugar con ventilaci n adecuada Rem tase a la secci n Requisitos del lu
3. Puede utilizarse una puerta con rejillas de ventilaci n con aberturas de escape equivalentes se muestran los espacios libres m nimos NOTA En el caso de instalaciones nuevas coloque el agujero de la parte superior de la pared a 42 plg 107 cm por encima del piso para facilitar la conexi n del sistema de ventilaci n 40 504607 SP Requisitos del sistema de escape de la secadora ADVERTENCIA Las secadoras de ropa producen pelusas combustibles Para reducir el peligro de incendio y acumulaci n de gases de combusti n la secadora DEBERA contar con una tuber a de escape al exterior Este electrodom stico a gas contiene o produce uno o m s productos qu micos que pueden ser altamente nocivos o incluso letales y que el Estado de California EE UU ha identificado como causantes de c ncer defectos de nacimiento y otros peligros para la reproducci n Para reducir el peligro que representan las sustancias presentes en el combustible o en su combusti n aseg rese de instalar operar y mantener este electrodom stico seg n las instrucciones que aparecen en este manual Para reducir el riesgo de incendio y acumulaci n de gases de la combusti n NO libere el escape de la secadora a trav s de un agujero en una ventana agujero de ventilaci n de gas chimenea o en un rea cerrada sin ventilaci n como por ejemplo tico pared techo espacio vac o de poca altura debajo de un edificio o cualquier
4. a el ctrica Secadoras a gas NOTA El diagrama de cableado se encuentra dentro de la campana de control ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica lesiones graves o letales todo el cableado y las conexiones a tierra DEBERAN satisfacer la edici n m s reciente de las Normas para Instalaciones El ctricas de los Estados Unidos National Electrical Code ANSI NFPA 70 o las Normas para Instalaciones El ctricas de Canad CSA C22 1 as como las normas locales aplicables Es responsabilidad del cliente hacer revisar el cableado y los fusibles por un electricista calificado para asegurarse de que su casa cuenta con la capacidad de energ a el ctrica necesaria para hacer funcionar la secadora NO SOBRECARGUE LOS CIRCUITOS NO UTILICE ADAPTADOR NO UTILICE CORD N DE EXTENSION 00091510 Instrucciones conexi n La secadora deber conectarse a tierra La conexi n a tierra reduce los riesgos de cortocircuitos en caso de mal funcionamiento o aver as el ctricas creando una ruta de menor resistencia para la corriente el ctrica La secadora tiene un cord n con un conductor de tierra del equipo y un enchufe de tierra de tres terminales Este enchufe deber conectarse directamente a un recept culo de 110 120 voltios de C A corriente alterna y 15 amperios de tres ranuras debidamente conectado a tierra ADVERTENCIA La conexi n indebida del
5. BY LOCAL CODES Use Design A G A Certified Connector IL 3 8 GAS CONNECTION BLACK IRON PIPE Shorter than 20 6 1 use 3 8 pipe gt Longer than 20 6 1 m use 1 2 pipe Connect to gas supply pipe Tighten all connections securely Turn on gas and check all pipe connections internal external for gas leaks with a non corrosive leak detection fluid For L P propane gas connection refer to Section on Gas Requirements 1 8 NPT PIPE PLUG For checking inlet gas pressure EQUIPMENT SHUT OFF VALVE Install within 6 1 8 m of dryer D233IE3D 504607 Step 4 ELECTRIC ONLY Connect Electrical Plug For further assistance refer to Section on Electrical Requirements IMPORTANT Use only a new U L listed No 10 copper wire only three conductor power supply cord kit rated 240 Volts minimum 30 Amperes and labeled as suitable for use in a clothes dryer TYPICAL THREE WIRE RECEPTACLE POWER CORD Three Wire STRAIN RELIEF RELIEF il 02751 00 Three Wire TYPICAL FOUR WIRE RECEPTACLE POWER CORD Four Wire STRAIN RELIEF RELIEF Four Wire DOO6IEOA NOTE For more detailed information on connecting three wire or four wire plugs refer to Section on Electrical Plug Connection NOTE Four wire cord is required for mobile homes or where codes do not permit grounding through neutral 504607 GROUND GROUND
6. DE CIERRE DEL EQUIPO Instale a una distancia TUBO DE HIERRO NEGRO m xima de 1 8 m Menos de 6 1 20 pies utilice tubo de 3 8 plg __ gt 6 pies de la secadora M s de 6 1 m 20 pies utilice tubo de 1 2 plg D2331S3B 504607 SP 29 Paso 4 S LO PARA SECADORAS EL CTRICAS Conexi n del enchufe de suministro de energ a el ctrica Rem tase a la secci n Requisitos el ctricos para obtener m s informaci n IMPORTANTE Utilice solamente un cord n de suministro de energ a el ctrica en lista de U L de tres conductores de cobre calibre 10 con capacidad para 240 voltios como m nimo 30 amperios que indique que es apropiado para secadoras de ropa RECEPT CULO NORMAL DE TRES CONDUCTORES CORDON DE SUMINISTRO DE ENERG A EL CTRICA NO VIENE CON LA SECADORA tres conductores TUERCA DE PROTECCI N CONTRA PROTECCI N CONTRA TIRONES Enchufe de tres conductores RECEPT CULO NORMAL DE CUATRO SUMINISTRO DE CONDUCTORES ENERG A EL CTRICA e cuatro conductores D275IS0F CORD N DE TUERCA DE PROTECCION CONTRA TIRONES PROTECCION CONTRA TIRONES Enchufe de cuatro conductores 00061510 NOTA Rem tase a secci n Conexi n del enchufe de suministro de energ a el ctrica para obtener m s informaci n sobre la conexi n de enchufes de tres o cuatro conductores NOTA El cable de cuatro conductores debe utilizarse en el caso de viv
7. To reverse door proceed as follows O Remove four hinge attaching screws Pull bottom of door liner out then pull down removing door liner from door panel Remove door strike from door liner and reinstall on opposite side Reinstall nine screws removed in Step 2 10 D271PE1B D268PE1A D276PE1B D270PE1B Reinstall four hinge attaching screws removed in Step 1 Remove all nine screws Rotate door panel 180 degrees as shown Insert liner under flange on bottom of door then push top of door liner into place Using a screwdriver remove two door plugs and reinstall on opposite side of door opening D272PE1A D273PE1C D269PE1C 504607 Manufactured Mobile Home Installation IMPORTANT Installation must conform to the Manufactured Home Construction and Safety Standards Title 24 Part 32 80 Standard CAN CSA Z240 MH The dryer can be installed in a manufactured mobile home by following these instructions 1 IMPORTANT Gas dryers MUST be permanently attached to the floor at the time of installation Order No 526P3 Dryer Installation Kit for a manufactured mobile home installation Follow the instructions supplied with the kit 2 Electrical Connections Electric Dryer Only must be a 4 wire connection refer to page 13 3 Venting Dryer MUST be exhausted to the outdoors To reduce the risk of fire and combustio
8. XIMA EN COLUMNA DE AGUA 0 6 plg 1 5 cm MAN METRO DUCTO D012ISOB DE ESCAPE Medici n de la presi n est tica Codo para espacio reducido Cuando se instala la secadora en un cl set poco profundo puede utilizarse un Codo Pieza No 62688 que es una pulgada m s delgado que el codo para abertura de escape est ndar D319IEOA Codo para espacio reducido 43 Instrucciones de mantenimiento para el usuario Lubricaci n Todas las piezas m viles est n selladas con un suministro permanente de lubricante o est n equipadas con cojinetes autolubricantes No se requiere lubricaci n adicional Cuidado de la secadora Saque las pelusas del filtro despu s de secar cada carga de ropa Si es necesario puede lavar el filtro Cada cierto tiempo saque el filtro de pelusas y limpie el rea que est debajo del filtro Normalmente el cilindro de la secadora no requiere cuidado alguno Lave el gabinete de la secadora seg n sea necesario Si se ha derramado detergente cloro u otro producto de lavado en la secadora l mpielo inmediatamente Algunos productos causan un da o permanente si se derraman sobre el gabinete No apoye objetos punzantes o rugosos contra la secadora ya que podr a da arse el acabado de la secadora Utilice nicamente pa os h medos o jabonosos para limpiar el panel de control A
9. adicionales El sistema de escape de la secadora que se instala a los lados o en la parte inferior puede conectarse utilizando un accesorio conjunto de piezas el sistema de escape direcccional 528P3 que puede obtenerse de manera opcional con un costo adicional l D328IE0A Conjunto para escape direccional 528P3 Cantidad de Tipo de tapa para intemperie codos de 90 Modelo recomendado Use nicamente con instalaciones cortas X Ze cm 4 pl 4 plo 6 35 En 2 1 2 plg 0011162 Longitud m xima del ducto met lico r gido de 4 plg 10 2 cm de di metro 34 pies 10 4 m 26 pies 7 9 m 20 pies 6 1 m 14 pies 4 3 m Longitud m xima del ducto met lico flexible de 4 plg 10 2 cm de di metro 0 44 pies 13 4 m 1 34 pies 10 4 m 2 26 pies 7 9 m 3 20 pies 6 1 m 0 24 pies 7 3 m 1 20 pies 6 1 m 2 16 pies 4 9 m 3 12 pies 3 7 m 20 pies 6 1 m 16 pies 4 9 m 12 pies 3 7 m 8 pies 2 4 m NOTA Reste 6 pies 1 8 m por cada codo adicional 42 504607 SP Mantenimiento del sistema de escape Despu s de utilizar la secadora durante un a o debe inspeccionarse el interior de la misma y el sistema de escape y limpiarlos si es necesario En lo sucesivo revise y limpie el ducto de escape cada uno o dos a os seg n sea necesario La tapa para intemperie debe revisarse frecuentemente para asegurarse de que la ta
10. in an area where it will be exposed to water and or weather The dryer must not rock The dryer needs sufficient clearance and an adequate are shown below Leveling legs can be adjusted from inside the dryer with a 1 4 driver All four legs must rest firmly on the CLOSET DOOR f A cay oor A gt FRONT VIEW w o Closet Door OUTER WALL OF ENCLOSURE SIDE VIEW go air supply for proper operation and ventilation and for easier installation and servicing Minimum clearances f CENTERED AIR O OPENINGS G 2 Openings Minimum FRONT VIEW Closet Door 03171 DESCRIPTION FREE STANDING ALCOVE INSTALLATION See Illustration CLOSET INSTALLATION See Illustration Dryer sides and rear clearance 0 0 cm 0 0 cm Dryer top clearance 12 30 5 cm 12 30 5 cm Dryer front clearance Not Applicable 2 5 1 cm Exhaust duct clearance to combustible material 2 5 1 cm 2 5 1 Weather hood to ground clearance 12 30 5 cm 12 30 5 cm Distance from floor or ceiling to hole edge Not Applicable 3 7 6 cm G Area of centered air openings in closet door Not Applicable 40 sq in open 260 sq cm Louvered door with equivalent air openings is acceptable Minimum clearances are show
11. loading door start the dryer in a heat setting refer to the Operating Instructions supplied with the dryer the dryer will start the igniter will glow red and the main burner will ignite IMPORTANT If all air is not purged out of gas line gas igniter may go off before gas is ignited If this happens after approximately two minutes igniter will again attempt gas ignition After the dryer has operated for approximately five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 8 3 1 mm PIPE PLUG For checking manifold pressure 504607 a Loosen the air shutter lockscrew b Turn the air shutter to the left to get a luminous yellow tipped flame then turn it back slowly to the right to obtain a steady soft blue flame c After the air shutter is adjusted for proper flame tighten the air shutter lockscrew securely d Reinstall the lower front panel For personal safety lower front panel must be in place during normal operation W046 After the dryer has operated for approximately three minutes exhaust air or exhaust pipe should be warm AIR SHUTTER LOCKSCREW APPLIANCE MAIN GAS VALVE SHUTTER 161 Reversing Door Procedure The door on this dryer is completely reversible
12. n de la instalaci n Rem tase a la secci n Revisi n del instalador que aparece en la contraportada de este manual y aseg rese de que la secadora est correctamente instalada 504607 SP 03271 2 0254151 SECADORA GAS Enchufe el cord n en un circuito de 15 amperios con fusible independiente 31 Revisi n de la fuente de calor Secadoras el ctricas Cierre la compuerta de carga y ponga a funcionar la secadora ajustando antes el grado de calor consulte las Instrucciones de operaci n suministradas con la secadora Cuando la secadora haya funcionado durante tres minutos el tubo de escape o de expulsi n de aire debe estar caliente Secadoras a gas Saque el panel frontal inferior de la secadora para ver la llama del quemador Cierre la compuerta de carga ponga a funcionar la secadora ajustando antes el grado de calor consulte las Instrucciones de operaci n suministradas con la secadora La secadora comenzar a funcionar el dispositivo de encendido se pondr al rojo vivo y el quemador principal se encender IMPORTANTE Si no se purga todo el aire de la tuber a de gas el dispositivo de encendido podr a apagarse antes de que se encienda el gas Si esto sucede despu s de dos minutos aproximadamente el dispositivo de encendido intentar encender el gas nuevamente Despu s de que la secadora haya funcionado durante cinco minutos aproximadamente vea la llama del quemad
13. o TO NEUTRAL WIRE NEUTRAL TERMINAL TERMINAL GROUND SCREW CENTER WIRE NEUTRAL STRAIN RELIEF NOT SUPPLIED WITH DRYER D276IE1A Three Wire Connection TRE GROUND TERMINAL WIRE NEUTRAL TERMINAL GROUND SCREW GROUND WIRE NOT SUPPLIED WITH DRYER D1711E1A Four Wire Connection NOTE Dryer is shown with access cover removed for illustration purposes only NEVER operate dryer with access cover removed Step 5 Wipe Out Inside Of Dryer Before using dryer for the first time use an all purpose cleaner or a detergent and water solution and a damp cloth to remove shipping dust from inside dryer drum 03271 2 Step 6 Plug in the Dryer Refer to Section on Electrical Requirements and connect the dryer to an electrical power source 02541 0 ELECTRIC Connect to 30 Amp circuit Plug cord into separately fused 15 Amp circuit Step 7 Check Installation Refer to Installer Check on the back cover of this manual and make sure that dryer is installed correctly 8 504607 Heat Source Check Electric Dryers Close the loading door and start the dryer in a heat setting refer to the Operating Instructions supplied with the dryer After the dryer has operated for three minutes the exhaust air or exhaust pipe should be warm Gas Dryers To view the burner flame remove the lower front panel of the dryer Close the
14. otro espacio cerrado Para reducir el riesgo de incendio NO utilice tubos de pl stico ni tubos de pl stico flexibles en el escape de la secadora C D314IS1A CORRECTO 504607 SP Nunca instale el ducto flexible en espacios ocultos como por ejemplo una pared o el techo Materiales del sistema de escape El ducto de escape de la secadora deber tener cuatro pulgadas 10 2 cm de di metro y no tener ning n tipo de obstrucci n Se recomienda un ducto met lico r gido Tambi n puede utilizarse un ducto met lico flexible semirr gido fabricado con un material que no sea combustible No utilice tubos de pl stico ni tubos de pl stico flexibles ya que contribuyen a un funcionamiento deficiente de la secadora y captan pelusas lo que podr a constituir riesgo de incendio NO UTILICE tornillos autorroscantes u otro tipo de piezas de sujeci n que sobresalga por la parte interior del ducto y que pudiera captar pelusas y reducir la eficiencia del sistema de escape Asegure bien todas las conexiones con cinta aislante para ductos Requisitos de aire de reposici n Para un buen funcionamiento de la secadora col quela en un rea con un flujo suficiente de aire de reposici n a fin de sustituir el aire expulsado por el sistema de escape de la secadora Las viviendas eficientes en el consumo de energ a el ctrica por tener niveles bajos de filtraci n de aire deber n equiparse co
15. them This maintenance work should be done by a qualified service person To reduce the risk of electric shock disconnect the electrical service to the dryer before cleaning W043 Exhausting the dryer in hard to reach locations can be accomplished by installing the 521P3 Flexible Metal Vent Kit available as optional equipment at extra cost The kit comes in two halves that can be separately attached to the dryer and wall outlet Once attached the dryer can be slid back into position and the two halves can be connected from the front 03201 521P3 Flexible Metal Vent 20 Dryer Airflow Efficient dryer operation requires proper dryer airflow Proper dryer airflow can be evaluated by measuring the static pressure Static pressure in dryer s exhaust duct should be no greater than that shown in the chart below Check with dryer running and no load NOTE This can be measured with a manometer placed on the exhaust duct approximately two feet 61 cm from the dryer see illustration below MAXIMUM STATIC PRESSURE IN WATER COLUMN 6 INCHES 1 5 MANOMETER EXHAUST DUCT 00121 Measuring Static Pressure Reduced Clearance Elbow Installing the dryer in shallow closets can be accomplished by using an Elbow Part No 62688 which is one inch narro
16. HERTZ O CORTACIRCUITOS CONDUCTOR CONDUCTOR NEUTRO PUEDE OMITIRSE CABLE CON FORRO METALICO O NO METALICO SOLO CONDUCTOR DE COBRE RECEPT CULO CABLE FLEXIBLE DE CONEXI N A LA SECADORA VER NOTA M S ABAJO oe oe CONEXION DE CABLE FLEXIBLE el ctricas Instrucciones para la conexi n a tierra Esta secadora debe conectarse a un sistema de cableado permanente que conecte las piezas met licas a tierra o alternativamente debe tenderse un conductor de tierra con los conductores del circuito que alimentan el equipo y conectarlo al terminal de conexi n de tierra de la secadora SUMINISTRO DE ENERG A EL CTRICA CAJA DEL INTERRUPTOR DE ENTRADA DEL CAJA DE INTERRUPCI N INTERMEDIA PUEDE TENER O NO FUSIBLES TIENE FUSIBLES NEUTRO L1 L2 L1 12 CONEXI N DIRECTA D003IS3F 35 Conexi n del enchufe de suministro de electricidad Enchufe de tres conductores 1 Saque la tapa de d 3 Utilice los tres TERMINAL acceso ubicada en tornillos que 411 NEUTRO la parte trasera de la est n en el sobre secadora ubicado en el cilindro para conectar los conductores del cord n de suministro de energ a el ctrica al bloque de terminales TERMINAL 42 D286IS0A 4 Apriete todos los tornillos y reinstale la tapa de Utilice un protector contra lt acceso que quit en el Paso 1 tirones e inserte el cord n de suministro de energ a a trav s del agujer
17. Installation Instructions Home Laundry Automatic Dryers Electric and Gas Models D3111E3A NOTA El manual en espa ol aparece despu s del manual en ingl s KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE If the dryer changes ownership be sure this manual accompanies the dryer Part No 504607R2 August 1998 FOR YOUR SAFETY the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death W033 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 Copyright 1998 Alliance Laundry Systems LLC All rights reserved No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher 504607 1 P Ta b nt ent Ss Before You Star
18. W STAINLESS STEEL FLEXIBLE CONNECTOR USE ONLY IF ALLOWED BY LOCAL CODES Use Design A G A Certified Connector 3 8 NPT GAS CONNECTION BLACK IRON PIPE Shorter than 20 6 1 m use 3 8 pipe Longer than 20 6 1 m use 1 2 pipe 16 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on nameplate located in the door recess Use a new flexible stainless steel connector Use pipe joint compound insoluble in LP propane Gas or Teflon tape on all pipe threads Purge air and sediment from gas supply line before connecting it to the dryer Before tightening the connection purge remaining air from gas line to dryer until odor of gas is detected This step is required to prevent gas valve contamination Do not use an open flame to check for gas leaks Use a non corrosive leak detection fluid W114R1 Altitude Orifice Size Part Number 503778 m Inches mm 58719 503779 503780 503781 1 8 NPT PIPE PLUG For checking inlet gas pressure Pa EQUIPMENT SHUT OFF a VALVE Installed within 6 1 8 m of dryer 0233 2 504607 Location Requirements floor so the weight of the dryer is evenly distributed Select a location with a solid floor No other fuel burning appliance should be installed in the same closet with the dryer The dryer must not be installed or stored
19. a informaci n anterior y guarde su recibo de compra Los n meros de serial y el modelo aparecen en la placa de identificaci n del electrodom stico 504607 SP 45 Installer Check Lista de comprobaci n del instalador Fast Track for Installing the Dryer Gu a r pida para instalar la secadora Refer to the manual for more detailed information V ase el manual para una informaci n m s detallada e Position and Level the Dryer Colocaci n y nivelaci n de la secadora 7 O LEVEL NIVEL O CHECK REALIZADO Connect Dryer Exhaust System Conexi n del sistema de escape de la secadora CHECK REALIZADO GAS ONLY PARA SECADORAS A GAS SOLAMENTE e Connect Gas Supply Pipe Check for Gas Leaks Conexi n del tubo de suministro de gas Verifique que no haya fuga de gas CHECK REALIZADO ELECTRIC ONLY PARA SECADORAS A EL CTRICAS SOLAMENTE Connect Electrical Cord Conexi n del enchufe de suministro de energ a el ctrica CHECK REALIZADO Wipe Out Inside of Dryer Limpieza de la parte interna de la secadora CHECK REALIZADO e Plugin the Dryer Conexi n el ctrica de la secadora ELECTRIC GAS SECADORA AGAS SECADORA ELECTRICA CHECK REALIZADO 504607
20. arse del tubo de suministro de gas durante la realizaci n de pruebas de presi n del sistema cuando se registren presiones de prueba superiores a 1 2 psi 3 45 kPa V ase la ilustraci n de la p gina 10 La secadora debe aislarse de la tuber a de suministro de gas cerrando la v lvula de interrupci n del equipo durante cualquier prueba de presi n del tubo de suministro de gas en caso de aplicarse presiones de prueba iguales o menores a 1 2 psi 3 45 kPa NOTA Cuando se conecte a una tuber a de gas la v lvula de interrupci n del equipo debe instalarse a una distancia no mayor de 6 pies 1 8 m de la secadora Asimismo debe instalarse un tap n de tubo N P T de 1 8 pulgadas tal como se indica en la figura Altitud Tama o del orificio N mero Pies Metros N Pulgadas Mil metros de pieza 0 0890 503778 0 0860 58719 0 0820 503779 0 0810 503780 0 0785 503781 504607 SP incendio o explosi n La secadora deber conectarse al tipo de gas indicado en la placa de identificaci n fijada en la compuerta Utilice un conector flexible nuevo de acero inoxidable Utilice compuesto para uniones de tuber a que sea insoluble en gas propano l quido o en su defecto cinta de tefl n en todas las roscas de uni n de tuber a Purgue el aire y sedimentos de la l nea de suministro de gas antes de conectarla a la secadora Antes de apretar la conexi n purgue
21. at nothing has been set against them Keep dryer area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not obstruct the flow of combustion and ventilation air NOTE Verify proper operation after servicing 21 Information for Handy Reference Alliance Laundry Systems LLC Shepard Street P O Box 990 Ripon WI 54971 0990 Date Purchased Model Number Serial Number Dealer s Name Dealer s Address Phone Number Service Agency Service Agency Address Phone Number NOTE Record the above information and keep your sales slip Model and serial numbers are located on the nameplate 22 504607 Instrucciones para la instalaci n de secadoras autom ticas de uso dom stico el ctricas y a gas D3111E3A GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA EN EL FUTURO Si la secadora cambia de due o aseg rese de que vaya acompa ada de estas instrucciones Pieza No 504607R2 Agosto 1998 ADVERTENCIA PARA SU SEGURIDAD deber seguir la informaci n contenida en el presente manual para minimizar el riesgo de incendio y explosi n y para prevenir da os a la propiedad y lesiones personales incluso letales No almacene o utilice gasolina o ning n otro vapor o l quido inflamable cerca de sta o de cualquier otra m quina QUE HACER SI SIENTE OLOR A GAS No intente en
22. cender ninguna m quina No toque ning n interruptor el ctrico no utilice ning n tel fono del edificio Evacue los ocupantes de la sala el edificio o el rea Llame inmediatamente a la compa a de gas desde el tel fono de un vecino Siga las instrucciones que le d la compa a de gas Si no puede ponerse en contacto con la compa a de gas llame a los bomberos La instalaci n y el mantenimiento deber n ser realizados por un instalador calificado una empresa de servicio o por la compa a de gas Derechos reservados 2000 Alliance Laundry Systems LLC Reservados todos los derechos Ninguna secci n del presente manual puede ser reproducida o transmitida en forma alguna o a trav s de ning n medio sin el expreso consentimiento por escrito del editor 24 504607 SP Piezas de repuesto Dimensiones aproximadas Antes de comenzar Herramientas Ducto de escape Requisitos el ctricos Requisitos de gas Ubicaci n Instalaci n de la secadora PASO 1 Colocaci n y nivelaci n de la secadora PASO 2 Conexi n del sistema de escape de la secadora PASO 3 Conexi n del tubo de suministro de gas PASO 4 Conexi n del enchufe de suministro de energ a electrica PASO 5 Limpieza de la parte interna de la secadora PASO 6 Conexi n el ctrica de la secadora PASO 7 Revisi n de la instalaci n Revisi n de la fuente de calor Procedimiento para invertir la compuerta Instalaci n en viviendas prefabricadas m v
23. conductor de tierra del equipo podr a poner a las personas en riesgo de descarga el ctrica Consulte a un t cnico de mantenimiento o electricista calificado si no est seguro de que la secadora est debidamente conectada a tierra 38 No realice modificaciones en el enchufe que trae la secadora Si el enchufe no entra en el recept culo de pared contrate los servicios de un electricista calificado para que instale el recept culo de pared adecuado ADVERTENCIA Esta secadora est equipada con un enchufe de tres terminales con conexi n a tierra para protegerlo contra posibles descargas el ctricas el cual deber enchufarse directamente a un recept culo de tres terminales debidamente conectado a tierra No corte o anule el terminal de tierra del enchufe CIRCUITO EST NDAR TERMINAL NEUTRO DE TRES CONDUCTORES 4 DE 120 VOLTIOS 60 HERTZ 15 AMPERIOS DEBIDAMENTE CONECTADO A TIERRA LADO 120 12 V C A TERMINAL DE TIERRA DE SECCI N REDONDA 0090151 NOTA Llame a un electricista calificado para que revise la polaridad del recept culo de pared Si la lectura del voltaje es distinta a la que aparece en la ilustraci n el electricista debe solucionar el problema No utilice el mismo circuito para poner a funcionar otros electrodom sticos cuando la secadora est funcionando ADVERTENCIA Para reducir el riesgo de descargas el ctricas o incendio NO utilice un adaptador
24. critos a continuaci n O Retire los cuatro tornillos que fijan la bisagra D271PS1A Tire de la parte inferior del revestimiento de la compuerta Seguidamente tire hacia abajo y saque el revestimiento del panel de la compuerta D268PS1C Retire el gancho de la compuerta del revestimiento y col quelo en el lado contrario D276PS1C Coloque de nuevo los nueve tornillos que sac en el Paso 2 D270PS1C Coloque nuevamente los cuatro tornillos para fijar la bisagra que sac el Paso 1 504607 SP 2 Saque los nueve tornillos D272PS1A Gire el panel de la compuerta 180 grados tal como se indica en el diagrama 6 Inserte el forro debajo del reborde en la parte inferior 1 de la puerta y seguidamente gt empuje la parte superior de la puerta hasta que quede en su lugar D273PS1C D269PS1D Con ayuda de un destornillador saque los dos tapones de la compuerta y col quelos en el lado opuesto al lado por el que abre la compuerta 33 Instalaci n en viviendas prefabricadas m viles IMPORTANTE La instalaci n debe hacerse de acuerdo con las Normas de seguridad y de construcci n de viviendas prefabricadas T tulo 24 CFR Parte 32 80 o con la Norma CAN CSA Z240 MH La secadora puede instalarse en una casa prefabricada m vil siguiendo estas instrucciones 1 IMPORTANTE Las secadoras a gas DEBERAN fijarse al piso
25. de manera permanente durante la instalaci n Pida el Conjunto de instalaci n de secadora N 526P3 para la instalaci n en casas prefabricadas m viles Siga las instrucciones que vienen con el conjunto de instalaci n 2 Los conectores el ctricos nicamente en el caso de las secadoras el ctricas deben ser de 4 conductores v ase la p gina 36 3 Sistema de aberturas de escape El sistema de escape de la secadora DEBERA descargarse hacia el exterior de la vivienda ADVERTENCIA Para reducir el peligro de incendio y acumulaci n de gases de combusti n la secadora DEBERA CONTAR CON UNA TUBER A DE ESCAPE AL EXTERIOR Consulte la secci n acerca de los requisitos de escape de la secadora El sistema de escape de la secadora debe descargarse hacia el exterior de la vivienda a trav s del panel inferior derecho izquierdo o trasero El sistema de escape de las secadoras a gas no puede descargarse por el lado izquierdo debido a que all se encuentra la caja del quemador El ducto del sistema de escape de la secadora debe fijarse a la estructura de la casa m vil Los ductos de escape NO DEBER N conectarse utilizando tornillos o sujetadores de chapa met lica que se extiendan hacia dentro el ducto 34 Los ductos de escape no deber n conectarse a otro ducto abertura de escape o chimenea Los ductos de escape de la secadora NO DEBER N terminar por debajo de la casa m vil Para un funcionamiento adec
26. dor de 1 4 de continuaci n La secadora no debe instalarse o colocarse en un rea donde est expuesta al agua o a la intemperie PUERTA ells DEL CL SET o f A ABERTURAS A qa Nw DE AIRE te QSENTRADAS G Dos aberturas gt como m nimo D OI A gt 106 7 cm 42 plg KY pan 11 S gt lt A A gt a d lt x C VISTA FRONTAL VISTA LATERAL PARED VISTA FRONTAL Sin la puerta del cl set ORNE O Con la puerta del cl set D317IS3A REA DESCRIPCI N INSTALACI N EN GABINETE LIBRE ver ilustraci n INSTALACI N EN CL SET ver ilustraci n Espacio libre a los lados y por la parte trasera de la secadora 0 plg 0 cm 0 plg 0 cm Espacio libre por arriba 12 plg 30 5 cm 12 plg 30 5 cm Espacio libre por la parte delantera No corresponde 2 plg 5 1 cm D Separaci n entre el ducto de escape y material 2 plg 5 1 cm 2 plg 5 1 cm combustible Espacio entre la tapa para intemperie y la tierra 12 plg 30 5 cm 12 plg 30 5 cm F Distancia entre el piso o techo y el borde No corresponde 3 plg 7 6 cm orificio G Area de los agujeros de entrada de aire No corresponde Orificio de 40 plg 260 cm centrados la puerta del cl set
27. e cylinder to attach the remaining power cord wires to the terminal block as follows a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire removed in Step 2 and attach along with the white wire to the neutral center terminal on the terminal block 6 Tighten all screws and reinstall access cover removed in Step 1 504607 Electrical Requirements Gas Dryers NOTE The wiring diagram is located inside the control hood To reduce the risk of fire electric shock serious injury or death all wiring and grounding MUST conform with the latest edition of the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 and such local regulations as might apply It is the customers responsibility to have the wiring and fuses checked by a qualified electrician to make sure your home has adequate electrical power to operate the dryer DO NOT OVERLOAD CIRCUITS DO USE ADAPTER DO NOT USE AN EXTENSION CORD 00091 Grounding Instructions The dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current The dryer is equipped with a cord having an equipment grounding conductor and a 3 prong grounding plug The three pron
28. e risk of fire electric shock serious injury or death all wiring and grounding MUST conform with the latest edition of the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 and such local regulations as might apply It is the customer s responsibility to have the wiring and fuses checked by a qualified electrician to make sure your home has adequate electrical power to operate the dryer NOTE The power cord pigtail is NOT supplied with the electric dryer Type of pigtail and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optional and subject to local code requirements NOTE Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on the nameplate A typical 30 Amp Three wire Receptacle NEMA Type 10 30R FUSE BOX MAY BE OMITTED IF SERVICE ENTRANCE BOX IS FUSED WALL RECEPTACLE Lee cos VAC 1 VAC 47 NEUTRAL 240 12 NOTE Use COPPER WIRE only Shorter than 15 4 5 m use 10 A W G Longer than 15 4 5 m use 8 A W G A typical 30 Amp Four wire Receptacle 120 12 240 12 120 12 120 12 DOO6IE1F 12 POWER SUPPLY INTERMEDIATE PIGTAIL CONNECTION Grounding Instructions This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and co
29. e to a gas dryer must conform with the local codes and ordinances or in the absence of local codes and ordinances with the latest edition of the National Fuel Gas Code ANSI 7223 1 NFPA 54 or the CAN CGA B149 National Gas Installation Code Natural Gas 1 000 Btu ft 37 3 MJ m service must be supplied at 6 5 1 5 inch water column pressure For proper operation at altitudes above 2 500 feet 760 m the natural gas valve spud orifice size must be reduced to ensure complete combustion See table at right L P Propane Gas 2 500 Btu ft 93 1 MJ m service must be supplied at 10 1 5 inch water column pressure NOTE DO NOT connect dryer to L P Propane Gas Service without converting the gas valve An Sales Accessory L P Propane Gas Conversion Kit 649P3 must be installed NOTE The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 45 kPa See illustration on page 10 The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa NOTE When connecting to a gas line an equipment shutoff valve must be installed within 6 1 8 of the dryer An 1 8 N P T pipe plug must be installed as shown See illustration NE
30. el aire remanente de la l nea de gas a la secadora hasta que se detecte olor a gas Este paso es necesario para evitar la contaminaci n de la v lvula de gas No utilice una llama para comprobar que no hay fugas de gas Utilice un l quido detector de fugas no corrosivo NUEVO CONECTOR FLEXIBLE DE ACERO INOXIDABLE USELO SOLO SILO AUTORIZAN LAS NORMAS LOCALES utilice un conector con dise o certificado por A G A CONEXI N DE GAS NPT DE 3 8 plg TUBO DE HIERRO NEGRO TAP N PARA TUBO NPT DE 1 8 plg para medir la presi n de entrada del gas V LVULA DE CIERRE DEL EQUIPO Instale m xima de 6 pies 1 8 m de la secadora Menos de 20 pies 6 1 m utilice tubo de 3 8 plg M s de 20 pies 6 1 m utilice tubo de 1 2 plg D238Is1C 39 Requisitos del lugar Seleccione un rea donde el piso sea firme pulgada Las cuatro patas deben descansar firmemente sobre el piso de manera que el peso de la secadora quede distribuido uniformemente La secadora no debe quedar coja No debe instalar otro aparato de encendido con combustible en el mismo mueble empotrado donde se encuentra la secadora La secadora necesita un espacio libre y un suministro de aire suficientes para un funcionamiento y ventilaci n id neos y una instalaci n y mantenimiento Las patas de nivelaci n pueden ajustarse desde la parte m s f ciles El espacio libre m nimo aparece a interna de la secadora con un destornilla
31. exible plastic pipe because it contributes to poor drying performance and collects lint which can lead to a fire hazard DO NOT use sheet metal screws on exhaust pipe joints or other fastening means which extend into the duct that could catch lint and reduce the efficiency of the exhaust system Secure all joints with duct tape Make Up Air Requirements For proper operation it is important that you locate the dryer in an area that has an ample amount of make up air to replace the amount exhausted by the dryer Energy efficient homes with low air infiltration rates should be equipped with an air exchanger that can accommodate on demand make up air needs in the home These devices can be obtained through your building contractor or building material suppliers 504607 Exhaust System IMPORTANT Keep exhaust duct as short as possible NOTE Be certain old ducts are cleaned before installing your new dryer For best drying results recommended maximum length of exhaust system is shown below To prevent backdraft when dryer is not in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances may be necessary for installations where heavy snowfall can occur Exhaust Direction The dryer can be exhausted to the outdoors through the back left right or bott
32. g grounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded W038 504607 Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician This dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug W036 STANDARD 120 VOLT 15 AMP 60 HERTZ 3 WIRE EFFECTIVELY GROUNDED CIRCUIT NEUTRAL 2 GROUND ROUND GROUNDING PRONG D090IE1E NOTE Have a qualified electrician check the polarity of the wall receptacle If a voltage reading is measured other than that illustrated the qualified electrician should correct the problem Do not operate other appliances on the same circuit when this appliance is operating To reduce the risk of an electric shock or fire DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source W037 15 Gas Requirements Gas Dryers NOTE The gas servic
33. gar para obtener m s informaci n 27 instalaci n de la secadora Paso 1 Colocaci n y nivelaci n de la secadora Rem tase a la secci n Requisitos del lugar para obtener una mejor orientaci n Instale la secadora antes que la lavadora De esta manera tendr espacio para conectar el ducto de escape Coloque la secadora en la posici n correspondiente y ajuste las patas hasta que quede nivelada BASE DE LA SECADORA PATA DE NIVELACI N 0298151 28 2 la secadora Rem tase a la secci n Requisitos del lugar y Requisitos de escape de la secadora para obtener una mejor orientaci n ADVERTENCIA Las secadoras de ropa producen pelusas combustibles Para reducir el riesgo de incendio y acumulaci n de gases de combusti n la secadora DEBERA contar con una tuber a de escape al exterior e NO UTILICE tubos pl sticos ni tubos flexibles de l mina met lica delgada e Ubique la secadora de tal manera que el ducto de escape tenga la menor longitud posible Aseg rese de que los tubos viejos est n bien limpios antes de instalar su secadora nueva e Utilice un tubo met lico flexible o r gido de 4 plg 10 2 cm e Use la menor cantidad de codos posibles e Utilice cinta aislante para ductos en todas las conexiones o empalmes La garant a queda sin efecto en caso de una instalaci n inapro
34. iendas m viles o en reas en las que los c digos no permitan una conexi n a tierra a trav s del conductor neutro 30 CONDUCTOR DE TIERRA AL TERMINAL NEUTRO CONDUCTOR DE TIERRA TERMINAL TERMINAL NEUTRO 14 TORNI x Sn 4 CONEXI N lt CONDUCTOR DEL CENTRO NEUTRO PROTECCI N CONTRA TIRONES NO VIENE CON LA SECADORA 0276818 Conexi n de tres conductores TERMINAL CONDUCTOR 11 DE TIERRA TERMINAL NEUTRO TORNILLO DE TIERRA TERMINAL 9 CONDUCTOR 7 DE CONEXI N Ll e STAM A TIERRA CONDUCTOR BLANCO NEUTRO PROTECCI N CONTRA o oR TIRONES NO VIENE CON LA SECADORA D1711S1B Conexi n de cuatro conductores NOTA En este diagrama la secadora aparece sin la tapa de acceso para fines de ilustraci n nicamente NUNCA ponga a funcionar la secadora sin la tapa de acceso 504607 SP 5 Limpieza de la parte interna de la secadora Antes de utilizar la secadora por primera vez aplique un limpiador para todo uso o una soluci n de agua y detergente con un pa o h medo a fin de eliminar el polvo que pueda haber ca do en el tambor de la secadora durante el embarque Paso 6 Conexi n el ctrica de la secadora V ase la secci n Requisitos el ctricos y conecte la secadora a un enchufe 0275161 SECADORA EL CTRICA Conecte la secadora a un circuito de 30 Amperios Paso 7 Revisi
35. iles Requisitos de energ a el ctrica secadoras el ctricas Conexi n del enchufe de suministro de electricidad Requisitos de energ a el ctrica secadoras a gas Requisitos del suministro de gas Requisitos del lugar Requisitos del sistema de escape de la secadora Materiales del sistema de escape Requisitos de aire de reposici n Sistema de escape Direcci n del escape Mantenimiento del sistema de escape Flujo de aire de la secadora Codo de espacio reducido Instrucciones de mantenimiento para el usuario Lubricaci n Cuidado de la secadora Sistema de escape Informaci n de referencia a la mano Lista de comprobaci n del instalador Piezas de repuesto Si se necesitan piezas de repuesto comun quese con el Alliance Laundry Systems LLC vendedor o con Shepard Street P O Box 990 Ripon WI 54971 0990 Tel fono 920 748 3950 para obtener el nombre y la direcci n del distribuidor autorizado de piezas de repuesto 504607 SP 25 Dimensiones aproximadas 10 2 cm D 65 2 i 1 1 71 1 4 plg 68 3 26 9 plg 23 5 plg 28 plg 91 4 cm 36 plg gt 109 2 cm 43 CON LAS PATAS DE NIVELACI N ENROSCADAS EN LA BASE SECADORAS EL CTRICAS 109 2 cm 43 91 4 36 3 A lt Hi 59 7 cm 71 1 A 23 5 28
36. lgunos productos de prelavado en aerosol pueden da ar el acabado del panel de control NOTA El diagrama del cableado se encuentra dentro del panel de control 44 CUIDADO Coloque etiquetas a todos los conductores antes de desconectarlos cuando est dando mantenimiento a los controles Un error en el cableado puede ocasionar un funcionamiento inadecuado y peligroso Sistema de escape El ducto de escape debe inspeccionarse al a o de uso de la secadora y limpiarse de ser necesario En lo sucesivo revise y limpie el ducto de escape cada uno o dos a os seg n sea necesario La tapa para intemperie debe revisarse frecuentemente para asegurarse de que la tapa del mecanismo articulado se mueva sin problemas no est hundida y no tenga pegado nada que impida su movimiento Mantenga el rea donde se encuentra la secadora limpia y sin materiales combustibles gasolina u otros l quidos o gases inflamables No obstruya el flujo de aire de ventilaci n y de combusti n NOTA Verifique su buen funcionamiento despu s del mantenimiento 504607 SP Informacion de referencia alamano Alliance Laundry Systems LLC Shepard Street P O Box 990 Ripon WI 54971 0990 Fecha de la compra Modelo N de serie Nombre del vendedor Direcci n del vendedor Tel fono del vendedor Agente de servicio Direcci n del agente de servicio Tel fono del agente de servicio NOTA Anote l
37. n NOTE For new installations locate top of wall vent 42 inches above floor to make venting easier to connect 504607 17 Dryer Exhaust Requirements A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors W116 This gas appliance contains or produces a chemical or chemicals which can cause death or serious illness and which are known to the State of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained according to the instructions in this manual W115 To reduce the risk of fire and the accumulation of combustion gases DO NOT exhaust dryer air into a window well gas vent chimney or enclosed unventilated area such as an attic wall ceiling crawl space under a building or concealed space of a building W045 To reduce the risk of fire DO NOT use plastic pipe or flexible plastic pipe to exhaust the dryer 18 Never install flexible duct in concealed spaces such as a wall or ceiling Exhaust System Materials Exhaust duct must be four inches 10 2 cm in diameter having no obstructions Rigid metal duct is recommended Non combustible semi rigid flexible metal duct is acceptable Do not use plastic pipe or fl
38. n gas accumulation the dryer MUST BE EXHAUSTED TO THE OUTDOORS Refer to Section on Dryer Exhaust Requirements W047 The dryer can be exhausted to the outdoors through the back left right or bottom panel Gas dryers cannot be exhausted out the left side because of the burner housing The dryer exhaust duct must be secured to the mobile home structure Exhaust ducts MUST NOT be connected with sheet metal screws or fasteners which extend into the duct Exhaust duct must not be connected to any other duct vent or chimney 504607 Dryer exhaust duct MUST NOT terminate under the mobile home For proper operation it is important that the dryer has an ample amount of outside make up air The free area of any opening for the introduction of outside air must be at least 25 in 163 cm2 When exhausting the dryer to the outdoors the dryer can be installed with 0 inch clearance at the sides and rear Clearance of the duct from combustible construction must be a minimum of 2 inches 5 08 cm Venting materials are not supplied with the dryer obtain locally To reduce the risk of fire the exhaust duct and weather hood MUST be fabricated of a material that will not support combustion Rigid or flexible metal pipe is recommended for a clothes dryer W048 11 Electrical Requirements Electric Dryers NOTE The wiring diagram is located inside the control hood To reduce th
39. n un intercambiador de aire que pueda adaptarse a las necesidades de aire de reposici n en el hogar Estos dispositivos pueden adquirirse a trav s del contratista de construcci n del inmuebles o proveedores de materiales de construcci n INCORRECTO 41 Sistema de escape IMPORTANTE Mantenga el ducto de escape lo m s corto posible NOTA Aseg rese de que los ductos viejos est n limpios antes de instalar su secadora nueva Para un mejor secado se recomienda no sobrepasar la longitud m xima especificada en el diagrama para el sistema de escape A fin de evitar la entrada de part culas cuando la secadora no est funcionando el extremo exterior del tubo de escape debe tener una tapa articulada para intemperie equipada con resorte se adquiere localmente NOTA La tapa para intemperie debe instalarse por lo menos 12 plg 30 5 cm por encima de la tierra En instalaciones donde es posible la ca da de una gran cantidad de nieve se requerir n alturas mayores Direcci n del escape El sistema de escape de la secadora puede descargarse hacia el exterior por la parte trasera izquierda derecha o inferior de la secadora EXCEPCI N Las secadoras a gas no pueden tener aberturas de escape en la parte izquierda debido a que all se encuentra la caja del quemador La secadora sale de la f brica lista para que se le instale el sistema de escape en la parte trasera No requiere piezas
40. nnected to the equipment grounding terminal or lead on the dryer POWER SUPPLY 3 WIRE GROUNDED NEUTRAL 120 240 VOLT 60 HERTZ AC 1 PHASE SERVICE ENTRANCE SWITCH BOX lt SEE NOTE BELOW _ gt CIRCUIT BREAKER NEUTRAL WIRE NEUTRAL WIRE INTERMEDIATE SHUT OFF BOX MAY OR MAY NOT BE FUSED METALLIC OR NON METALLIC SHEATHED CABLE COPPER WIRE ONLY PIGTAIL TO DRYER SEE NOTE BELOW NEUTRAL TERMINAL BLOCK ee IN DRYER L1 L2 L1 L2 DIRECT CONNECTION D003IE3A 504607 Electrical Plug Connection Three Wire Plug 1 Remove access cover from rear of dryer 2 Use a strain relief and insert end of power cord through power supply hole 504607 L14 NEUTRAL 3 Use the three TERMINAL TERMINAL screws from the envelope located in the cylinder to attach the power cord wires to the terminal block TERMINAL 02861 0 4 Tighten all screws and reinstall access cover removed in Step 1 D285IE0D 13 Four Wire Plug 1 Remove access cover from rear of dryer 2 Remove ground screw and save for use in Step 4 Remove wire and use in Step 5 Use a strain relief and insert end of power cord through power supply hole 14 02841 0 GROUND SCREW 4 Attach power cord ground green wire to rear bulkhead using ground screw removed in Step 2 TERMINAL 02891 5 Use three screws from envelope located in th
41. o cord n de extensi n para conectar la secadora a la fuente de energ a el ctrica 504607 SP Requisitos del suministro de gas Secadoras a gas ADVERTENCIA Para reducir el peligro de fugas de gas NOTA El servicio de gas para las secadoras a gas debe cumplir con las estipulaciones de los c digos y ordenanzas locales y en ausencia de los mismos deber suministrarse de acuerdo con la edici n m s reciente del C digo nacional sobre gas combustible ANSI Z223 1 NFPA 54 o el C digo nacional para la instalaci n de gas combustible CAN CGA B149 Gas natural 1000 Btu pie 37 3 MJ m El servicio de gas deber suministrarse a una presi n de columna de agua de 6 5 1 5 pulgadas Para un funcionamiento apropiado a altitudes superiores a los 2 500 pies 760 m el tama o del orificio del mechero de la v lvula de gas debe reducirse a fin de garantizar una combusti n completa V ase el cuadro de la derecha Gas propano l quido 2500 Btu pie 93 1 MJ m El servicio de gas deber suministrarse a una presi n de columna de agua de 10 1 5 pulgadas NOTA NO conecte la secadora al servicio de gas propano l quido sin la previa conversi n de la v lvula de gas Deber hacer que el concesionario o distribuidor autorizado por el fabricante o personal de servicio local instale un conjunto de conversi n a gas propano l quido N 458P3 NOTA La secadora y su v lvula de gas principal deben desconect
42. o de suministro de energ a el ctrica D285IE0D 36 504607 SP Enchufe de cuatro conductores 4 Conecte el conductor de tierra verde al tabique trasero utilizando los tornillos de tierra que retir 1 Saque la tapa de en el Paso 2 acceso ubicada en la parte trasera de la secadora BLANCO TORNILLO Saque el tornillo de tierra y DE TIERRA gu rdelo para utilizarlo en el Paso 4 Retire el conductor y gt D289ISOA selo en el Paso 5 Utilice los tres tornillos de tierra en el sobre ubicado en el cilindro para conectar el resto de los conductores del cord n de suministro de energ a el ctrica al bloque del terminales como se indica a continuaci n a Conductor rojo al terminal L1 b Conductor negro al terminal L2 Use un protector c Conductor blanco al terminal neutro contra tirones e inserte el extremo del cord n de CONDUCTOR RNY ES NOTA Cuando instale el conductor blanco suministro de DE TIERRA W enlace el extremo del ojete libre del conductor de energ a a trav s del DON DE tierra que sac el Paso 2 y con ctelo junto con orificio de ALIMENTACI N AY el conductor blanco al terminal neutro centro en suministro de Ge el bloque de terminales energ a el ctrica Y 6 Apriete todos los tornillos y coloque nuevamente D288IS0A la tapa de acceso que sac el Paso 1 504607 SP 37 Requisitos de energ
43. om of the dryer EXCEPTION Gas dryers cannot be vented out the left side because of the burner housing Dryer is shipped from factory ready for rear exhaust no kits required Exhausting the dryer through sides or bottom can be accomplished by installing a DK1 Sales Accessory Directional Exhaust Kit 528P3 available as optional equipment at extra cost 03281 528P3 Directional Exhaust Kit Number of Weather Hood Type 90 Elbows Recommended Use only for short run installations A 10 16 2 1 2 6 35 1 0 16 001 1 2 Maximum length of 4 10 2 cm diameter rigid metal duct 0 44 feet 13 4 m 34 feet 10 4 m 1 34 feet 10 4 m 26 feet 7 9 m 2 26 feet 7 9 m 20 feet 6 1 m 3 20 feet 6 1 m 14 feet 4 3 m Maximum length of 4 10 2 cm diameter flexible metal duct 0 24 feet 7 3 m 20 feet 6 1 m 1 20 feet 6 1 m 16 feet 4 9 m 2 16 feet 4 9 12 feet 3 7 m 3 12 feet 3 7 m 8 feet 2 4 m NOTE Deduct 6 feet 1 8 m for each additional elbow 504607 19 Exhaust System Maintenance The dryer interior and the complete exhaust system should be inspected after one year of use and cleaned if necessary Inspect and clean exhaust duct every one to two years as required thereafter The weather hood should be checked frequently to make sure the dampers move freely dampers are not pushed in and that nothing has been set against
44. or a trav s del panel frontal inferior Ajuste el TAP N DE TUBO DE 1 8 PULGADAS 3 1 mm para medir la presi n del distribuidor obturador de aire para lograr una llama azul suave y uniforme Una llama d bil y amarillenta es indicio de falta de aire Una llama azul ruidosa y muy fuerte revela que hay demasiado aire Ajuste el obturador de aire de la manera siguiente a Afloje el tornillo de fijaci n del obturador de aire b Gire el obturador de aire hacia la izquierda para lograr una llama luminosa con las puntas amarillas A continuaci n gire lentamente el obturador hacia la derecha hasta tener una llama azul suave y estable Despu s de ajustar el obturador de aire para lograr una llama adecuada apriete el tornillo de fijaci n hasta que quede bien asegurado d Coloque nuevamente el panel delantero inferior ADVERTENCIA Por razones de seguridad personal el panel delantero inferior deber mantenerse instalado en su lugar mientras la m quina est funcionando Despu s de que la secadora haya funcionado durante tres minutos aproximadamente el tubo de escape o de expulsi n de aire debe estar caliente TORNILLO DE FIJACI N DEL OBTURADOR DE AIRE V LVULA DE GAS PRINCIPAL DE LA SECADORA OBTURADOR DE AIRE 0316153 32 504607 SP Procedimiento para invertir la compuerta La compuerta de la secadora es totalmente reversible Para invertir la compuerta siga los pasos des
45. pa del mecanismo articulado no est bloqueada o hundida y que no se haya pegado nada al mismo Este mantenimiento debe ser realizado por personal calificado ADVERTENCIA Para reducir el peligro de descarga el ctrica desconecte el suministro el ctrico a la secadora antes de limpiarla Para verter el producto del sistema de escape hacia un lugar de dif cil acceso puede instalarse el Conjunto de ducto de escape met lico flexible 521P3 disponible como equipo opcional con un costo adicional El conjunto consta de dos piezas que pueden conectarse por separado a la secadora y a la toma de pared Una vez fijadas ambas piezas puede colocarse la secadora nuevamente en la posici n adecuada y dichas piezas pueden conectarse desde la parte delantera de la secadora Conjunto de ducto de escape met lico flexible 521P3 504607 SP Flujo de aire de la secadora Para funcionar adecuadamente la secadora debe contar con el flujo de aire apropiado Puede determinar si el flujo de aire es adecuado midiendo la presi n est tica La presi n est tica del ducto de escape de la secadora no debe ser mayor a la que se indica en el diagrama Revise la presi n con la secadora funcionando sin carga de ropa NOTA La presi n puede medirse colocando un man metro en el ducto de escape a aproximadamente dos pies 61 cm de la secadora V ase la ilustraci n siguiente PRESI N EST TICA M
46. piada del sistema de escape de la secadora D3141S1B CORRECTO INCORRECTO NOTA Los materiales del sistema de ventilaci n no vienen con la secadora pueden adquirirse localmente 504607 SP Paso 3 S LO para secadoras gas Conexi n del tubo de suministro de gas Rem tase a la secci n Requisitos de gas para obtener 3 Conecte el tubo de suministro de gas m s informaci n 2 4 bien todas las conexiones Abra la llave del 1 Aseg rese de que la secadora est equipada para gas y revise todas las conexiones del tubo internas utilizar el tipo de gas disponible en el rea de y externas para ver si hay fuga de gas utilizando lavander a La secadora viene equipada de f brica con l quido no corrosivo para detectar fugas con una conexi n de gas NPT de 3 8 pulgadas para trabajar con gas natural 5 En el caso de instalaciones de gas propano l quido v ase la secci n Requisitos de gas 2 Retire la tapa utilizada para fines de embarque de la conexi n de gas que se encuentra en la parte trasera de la secadora Tenga cuidado de no da ar la rosca del tubo cuando saque la tapa CONECTOR FLEXIBLE NUEVO DE ACERO INOXIDABLE SOLO SI LO AUTORIZAN CONECTOR DE TUBO LAS NORMAS LOCALES NPT DE 1 8 plg para medir la utilice un conector presi n de entrada del gas con dise o certificado por A G A CONEXI N DE GAS NPT DE 9 5 mm 3 8 plg V LVULA
47. r before washer This allows room for attaching exhaust duct Place the dryer in position and adjust the legs until the dryer is level LEVELING LEG 02981 Step 2 Connect Dryer Exhaust System For further assistance refer to Sections on Location Requirements and Dryer Exhaust Requirements A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors e DO NOT use plastic or thin foil flexible ducting 03141 0 e Locate dryer so exhaust duct is as short as possible Be certain old ducts are cleaned before installing your new dryer NOTE Venting materials are not supplied with the e Use 4 10 2 cm diameter rigid or flexible metal dryer obtain locally duct e Use as few elbows as possible Use duct tape on all joints Failure to exhaust dryer properly will void 504607 5 Step 3 Gas Dryer ONLY Connect Gas Supply Pipe For further assistance refer to Section on Gas Requirements 1 Make certain your dryer is equipped for use with 3 the type of gas in your laundry room Dryer is equipped at the factory for Natural Gas with a 3 8 s NPT gas connection 2 Remove the shipping cap from the gas connection 5 at the rear of the dryer Make sure you do not damage the pipe threads when removing the cap NEW STAINLESS STEEL FLEXIBLE CONNECTOR USE ONLY IF ALLOWED
48. s normas locales aplicables Es responsabilidad del cliente hacer revisar el cableado y los fusibles por un electricista calificado para asegurarse de que su casa cuenta con la capacidad de energ a el ctrica necesaria para hacer funcionar la secadora SUMINISTRO DE ENERG A EL CTRICA NOTA El cable de energ a el ctrica cable flexible de conexi n NO se suministra con la secadora el ctrica El tipo y calibre del cable flexible de conexi n deber n cumplir con las especificaciones de los c digos locales y las instrucciones El m todo de cableado para la secadora es opcional y depende de las estipulaciones locales NOTA Conecte la secadora al enchufe que indique el VOLTAJE MAXIMO especificado en la placa de identificaci n del equipo Recept culo normal de 30 amperios de tres conductores tipo NEMA 10 30R NOTE Utilice INTERMEDIA solamente CONDUCTOR DE COBRE Para una longitud menor a 15 pies 4 5 m use conductores calibre 10 AWG SILA CAJA DE ENTRADA DEL SERVICIO DE PARED V C A 240 12 V C A 120 12 3S Ws Para una longitud mayor a 15 pies 4 5 m use conductores calibre 8 AWG V C A Recept culo normal de 30 amperios de cuatro conductores 120 12 V C A 120 12 V C A DOO6IS1E 504607 SP CAJA DE FUSIBLES SERVICIO DE TRES CONDUCTORES CON NEUTRO CONECTADO A TIERRA lt lt MONOFASICO 120 240 gt VOLTIOS DE C A 60
49. t Installing the Dryer STEP 1 Position and Level the Dryer STEP 2 Connect Dryer Exhaust System STEP 3 Connect Gas Supply Pipe STEP 4 Connect Electrical Plug STEP 5 Wipe Out Inside of Dryer STEP 6 Plug in the Dryer STEP 7 Check Installation Heat Source Check Reversing Door Procedure Manufactured Mobile Home Installation Electrical Requirements Electric Dryers Electrical Plug Connection Electrical Requirements Gas Dryers Gas Requirements Location Requirements Dryer Exhaust Requirements Exhaust System Materials Make Up Air Requirements Exhaust System Exhaust Direction Exhaust System Maintenance Dryer Airflow Reduced Clearance Elbow User Maintenance Instructions Lubrication Care of Your Dryer Exhaust System Information for Handy Reference Installer Check Replacement Parts If replacement parts are required contact the source where you purchased your dryer or contact Alliance Laundry Systems LLC Shepard Street P O Box 990 Ripon WI 54971 0990 Phone 920 748 3950 for the name and address of the nearest authorized parts distributor 504607 Roughing In Dimensions k 43 109 2 36 91 4 cm A 23 5 28 1 1 26 9 71 1 cm 68 3 cm 59 7 cm 03121 WITH LEVELING LEGS TURNED INTO BASE ELECTRIC DRYERS 36 91 4 cm
50. uado la secadora debe contar con suficiente aire de reposici n proveniente del exterior El espacio libre de cualquier agujero hecho para la entrada de aire del exterior debe ser de por lo menos 25 ple 163 Cuando el sistema de escape de una secadora se descarga hacia el exterior dicha secadora puede instalarse dejando un rea de despeje a los lados y en la parte trasera de O plg El rea de despeje o espacio libre del ducto de escape con respecto a la construcci n donde se encuentra el combustible debe ser por lo menos de 2 plg 5 08 cm El material del sistema de aberturas de escape no se suministra con la secadora puede adquirirse localmente ADVERTENCIA Para reducir el riesgo de incendio el ducto de escape y la tapa para intemperie DEBERAN estar fabricadas de un material que no favorezca la combusti n Para las secadoras de ropa se recomienda utilizar tubo met lico ya sea r gido o flexible 504607 SP Requisitos de energ a el ctrica secadoras NOTA El diagrama de cableado se encuentra dentro de la campana de control ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica lesiones graves o letales todo el cableado y las conexiones a tierra DEBERAN satisfacer la edici n m s reciente de las Normas para Instalaciones El ctricas de los Estados Unidos National Electrical Code ANSI NFPA 70 o las Normas para Instalaciones El ctricas de Canad CSA C22 1 as como la
51. wer than a standard venting elbow D319IE0A Reduced Clearance Elbow 504607 User Maintenance Instructions Lubrication All moving parts are sealed in a permanent supply of lubricant or are equipped with oilless bearings Additional lubrication will not be necessary Care of Your Dryer Clean the lint filter after drying each load The lint filter may be washed if needed Occasionally remove lint filter and vacuum the area under it Ordinarily the dryer cylinder will need no care Wipe the dryer cabinet as needed If detergent bleach or other washing products have been spilled on the dryer wipe immediately Some products will cause permanent damage if spilled on the cabinet Do not allow sharp or rough objects to lean against the dryer The finish could be damaged Use only a damp or sudsy cloth for cleaning the control panel Some spray prewash products may harm the finish on the control panel NOTE The wiring diagram is located inside the control panel CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation W049 504607 Exhaust System The exhaust duct should be inspected after one year of use and cleaned if necessary Inspect and clean exhaust duct every one to two years as required thereafter The weather hood should be checked frequently to make sure the dampers move freely dampers are not pushed in and th