1. Oscillating Motor Shown Non Oscillating Motor Shown Figure 4 CAUTION THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY ar SUPPORT CABLE Figure 5 Loop one end of Cable around the Large Guard Wires of both the Front and Rear Grills gt Attach a Cable Clamp with the U on the tail side of the loop leaving a tail approxi Large Guard mately 1 to 2 inches Tighten Clamp Nuts Make sure no part of the Cable interferes with Wires the Blade 3 Wrap the other end of the Cable around a secure building joist truss or other support near the Fan Take up all excess slack in the Cable CAUTION USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN 4 Attach the remaining Cable Clamp as indicated in Step 2 The excess tail should be trimmed to extend 1 to 2 inches past the Clamp 5 Check the Assembly to assure the Blade is free of all obstructions CAUTION Use of the secondary support cable does not guarantee protection against injury of persons mounting of both the circulator and cable could fail if subjected to abuse neglect or improper installation OPERATING INSTRUCTIONS 1 _TO OPERATE Plug cord into a grounded 120V 60 Hz outlet Select desired operating speed with pull cord on the rear of the motor First pull High Second pull Medium Third pull Low Fourth pull OFF NO
2. For Non Oscillating Motor Slide the Motor Neck Slot over the Motor Mounting Adapter Align the 1 2 diameter hole in the Adapter with the 1 2 diameter holes in the Motor neck Slot Figure 2B 10 Insert the 1 2 X 1 Hex Bolt 8 4 head through the Motor Neck and the Motor Mounting Adapter Place 1 2 diameter Split Lock washer then the 1 2 diameter Hex Nut 8 4 head and tighten fully with 2 adjustable wrenches 11 From the same side of the Motor Neck insert one 1 4 20 X 1 5 8 Carriage Bolt through the Arc Shaped Slot in the Motor Neck and Hole in the Motor Mounting Adapter To Fasten Place one 1 4 Flatwasher one 1 4 Internal Tooth Lockwasher a second 1 4 Flatwasher and then tighten the Adjustable Knob over the remaining threads Oscillating Motor View Motor Mounting ___ Adapter Figure 1 Pipe Mounting __ gt Flange 2 lt a Threaded Pipe SORNE 243 N Application Loctite 243 Ss Set Screw Motor Mounting Adapter Ceiling Mount Assembly Rev A 11 07 2 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL GRILL AND BLADE ASSEMBLY Figures 3 and 4 NOTE The assembly of the blade and grill is identical regardless if the Fan has an oscillating motor or a non oscillating motor One of each is shown in the illustrations below 1 Install the Rear Grill onto the Motor lining up the six holes in the grill with the six threaded holes in the Motor Instal
3. IMPORTANT INSTRUCTIONS OPERATING MANUAL FOR OSCILLATING MODELS OSCILLATION Push down oscillation knob on motor housing to make fan head move from side to side NOTE FOR OSCILLATING MODELS FAN IS SHIPPED WITH 90 OSCILLATION ANGLE FOR 45 OSCILLATION ANGLE CONNECT THE OSCILLATION LINK TO THE INNER MOST HOLE IN THE CAM GEAR Inset A MAINTENANCE WARNING ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING WARNING DO NOT IMMERSE FAN IN WATER CLEANING Use a soft cloth and mild soap solution such as liquid dish washing detergent Dry all parts completely before reconnecting to power supply CAUTION Do not use gasoline benzine thinner harsh cleaners etc as they will damage the Fan NEVER use AL COHOL OR SOLVENTS SERVICING All other servicing with the exception of general user maintenance should be performed by an authorized service repre sentative Call 1 800 233 0268 Monday through Friday between the hours of 8 00 a m and 5 00 p m Eastern for the location of your nearest service center LUBRICATION Precision bearings are sealed at the factory for life and do not require further lubrication STORAGE Store the Fan with these instructions in a clean and dry place LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for one 1 year
4. CILLATING CEILING MOUNT FAN MODEL 9724 9330 9371 9370 GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following 1 Read all instructions before using Fan 2 Make certain that the power source conforms to the electrical requirements of the Fan 3 Use this Fan only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 4 Toreduce the risk of personal injury and electric shock the Fan should not be played with or placed where small children can reach it 5 Unplug power cord before servicing or moving the Fan ARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This Fan must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 7 DO NOT use Fan in or near a window Rain may create an electrical hazard 8 Completely reassemble Fan according to instructions before reconnecting to power supply 9 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances must the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be replaced w
5. MINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 233 0268 Email producthelp laskoproducts com Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 5pm Eastern Please have your model number available as well as the type and style located on the underside of your product Please do not return product to place of purchase Customer Service Dept 820 Lincoln Ave West Chester PA 19380 Please do not send product to this location www laskoproducts com PARTS FOR DISCONTINUED OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE DUE TO SAFETY REASONS MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT Rev A 11 07 4 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products 24 30 OSCILLATING CEILING MOUNT FAN MODEL 9324 9335 9374 9375 24 30 NON OS
6. TE THIS FAN IS VERY HEAVY Failure to securely hold onto head assembly while adjusting head angle could result in personal injury 2 TO ADJUST HEAD ANGLE While holding head firmly loosen knob under motor turn counterclockwise Tilt head to desired position FIRMLY retighten knob under motor NOTE Motor Head Adjustment Knob and the On Off Pull Cord have the same location on oscillating or non oscillating models Rev A 11 07 3 5084416 Figure 5
7. from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TER
8. ith a properly grounded three prong receptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION USE OF SUCH ADAPTERS ARE NOT PERMITTED IN CANADA 10 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed Never use a single extension cord to operate more than one Fan Rev A 11 07 SAVE THESE INSTRUCTIONS 11 Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner Return Fan to authorized service facility for examination electrical or mechanical adjustment or repair 12 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan in any manner while it is in operation 13 Locate the Power Cord so the Fan or other objects are not resting on it Do not run Power Cord under carpeting Do not cover Power Cord with throw rugs runners or the like Arrange Power Cord away from room traffic and where it will not be tripped over 14 This Fan is not intended for use in wet or damp locations Ne
9. l 6 10 32 X 5 16 Hex Screws through the Rear Grill into the Motor Securely tighten all 6 screws Figure 3 2 Push the Fan Blade onto the Motor Shaft centering the Hub facing away from the motor until it stops against the shaft Inset A Align Square Head Bolt with flat of the Motor Shaft TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH Failure to se curely tighten the Bolt could result in damage to the Fan and or personal injury 3 Hold the Front Grill so that the name in the center is right side up and straight across Starting at the top Fasten Front Grill to Rear Grill by sliding the hooked wires on the Front Grill over the outermost ring on the Rear Grill Figure 4 Detail A The bottom most hooks will require the use of a flathead screwdriver to complete assembly Stand behind the Fan Slip the flat of the screwdriver be tween the Front and Rear Grills next to one of the unfastened hooks Figure 4 Detail B Pull screwdriver handle upwards towards the Rear Grill Slip the Front Grill hook over the Rear Grill outer ring with a push Repeat procedure with remaining hooks CAUTION DO NOT BEND WIRES ON THE FRONT OR THE REAR GRILLS Inset A Detail B Bottom Hooks
10. structure can safely support the installed Fan 2 Open one tube of Loctite 243 by snapping tube neck just below end cap Be Certain to follow all warnings noted on Loctite 243 tube 3 Apply 1 ENTIRE tube of Loctite 243 onto the first 2 threads of one end of the Threaded Pipe that will be screwed into the Motor Mounting Adapter Figure 1 Inset 4 Screw Threaded Pipe into Motor Mounting Adapter The Threaded Pipe MUST BE screwed in at least 4 full revolutions Do not allow Loctite 243 to dry before joining Tighten provided 1 4 Set Screw into Motor Mounting Adapter Figure 1 5 Open second tube of Loctite 243 by snapping tube neck just below end cap Be Certain to follow all warnings noted on Loctite 243 tube 6 Apply 1 ENTIRE tube of Loctite 243 onto the first 2 threads of the opposite end of the Threaded Pipe that is now screwed into the Motor Mounting Adapter Figure 1 Inset 7 Screw Threaded Pipe with Motor Mounting Adapter to the Pipe Mounting Flange TheThreaded Pipe with Motor Mounting Adapter MUST BE screwed in at least 4 full revolutions into the Pipe Mounting Flange Do not allow Loctite 243 to dry before joining Figure 1 Tighten provided 1 4 Set Screw into Pipe Mounting Flange Figure 1 CAUTION FAN IS HEAVY AND MAY REQUIRE TWO PEOPLE TO MOUNT 9 Attach pull string to motor speed switch if desired For Oscillating Motor Place the flat section on the Motor Mounting Adapter next to the Motor Neck Figure 2A
11. ver locate a Fan where it may fall into a bathtub or other water container 15 Do not use Fan outdoors 16 This Fan is not suitable for use in agricultural facilities including areas where livestock poultry or other animals are confined Please refer to National Electric Code NEC Article 547 7 2008 or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547 7 2008 17 This Fan is not suitable for use in hazardous locations Please refer to National Electric Code NEC Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 2008 WARNING REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES CAUTION BECAUSE OF THE SIZE AND WEIGHT OF THIS FAN MAKE SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDING TO INSTRUCTIONS FAILURE TO DO SO COULD RESULT IN FAN COMING APART DURING OPERATION AND OR PERSONAL INJURY 5084416 IMPORTANT INSTRUCTIONS OPERATING MANUAL CEILING MOUNT INSTALLATION Figures 1 and 2 NOTE Distance mounted from the ceiling can be changed by using a length of 1 1 2 NPT pipe Simply substitute your pipe for the provided threaded pipe 1 Locate the Pipe Mounting Flange securely mount to ceiling structure Ensure ceiling