Home

Air King AIK14XL User's Manual

image

Contents

1. 1 Fan Grill Housing Ss 5S7635037 New 10 06 WWW AIRKINGLIMITED COM NOTE Units that include only one collar do not utilize the Y transition Follow the same instructions as in step 1 except connect the one end of the ducting directly to the fan 2 Connect one end of the ducting to the top of the Y transition and the other end to the intake of the fan Figure 11 3 Connect one end of the ducting to the exhaust of the fan and the other end to a wall or ceiling cap Figure 11 Always duct the fan to the outside through a wall or roof cap NOTE When using insulated flexible duct it is recommended that the inner vinyl core be screw clamped or taped to the inlet and outlet and that the vapor barrier surrounding the insulation be taped to the fan housing NOTE When attaching flex duct to the collar damper combination and an immediate elbow is necessary be certain that the elbow is installed with a soft bend to allow damper blades to operate properly SECTION 7 Installing Optional Balancing Damper Some kits include an optional balancing damper to allow for adjustment of the system The damper may be used where the grills will be connected using branches of unequal length or where the flow will need to be balanced for any reason To Install the optional damper 1 The damper must be installed on t
2. fauts de main d uvre et ou de mat riel Cette garantie ne couvre pas de co ts de transport ou de main d uvre ou le co t de remplacement de composantes faisant partie d entretien de routine tels que Filtres graisse des hottes de cuisine filtres au charbon ou combin filtre graisse charbon ampoules lectriques de remplacement dans les hottes de cuisine ou les combin s ventilateur lumi re chaufferette pour salle de bain Aussi tout dommage ou d faillance caus par un abus une mauvaise utilisation une installation fautive ou un entretien incorrect ne sera pas couvert par cette garantie De mani re effectuer une r clamation sous cette garantie vous devez tre l acheteur original du produit Il vous sera exig de pr senter la facture d achat originale Air King qui d montrera La date d achat l endroit de l achat et le mod le achet Le manquement rencontrer ces exigences annulera votre garantie Air King ne sera pas tenu responsable de quelque blessure corporelle ou dommage la propri t ou l immeuble que ce soit caus directement ou indirectement par le produit Certains Etats ne permettent pas de limitation sur la dur e de la garantie implicite ou l exclusion ou la limitation de dommages indirects ou accessoires ainsi ces limitations et exclusions peuvent ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir des droits qui varient d un E
3. Society for Heating Refrigeration 14 Ne pas ins rer les doigts ou tout corps tranger dans le moteur and Air Conditioning Engineers ASHRAE et de celles des autorit s locales du code AVERTISSEMENT NE PAS UTILISER DANS LES CUISINES 10 Peut tre utilis avec r glage de vitesse semi conducteurs 11 Cette unit comprend des parties rotatives Des mesures de s curit devraient donc tre prises pendant son installation son fonctionnement et son entretien 12 Des gardes protectrices doivent tre install es lorsqu il est la port e du personnel ou l int rieur de 2 13 m d un niveau de travail ou lorsque cette mesure s av re n cessaire pour assurer la s curit CONSERVER CES INSTRUCTIONS 5S7635037 New 10 06 WWW AIRKINGLIMITED COM 9 of 16 INSTRUCTIONS D INSTALLATION AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration en pr vision de l installation du ventilateur 1 Lorsque vous choisissez l emplacement pour l installation du ventilateur les crit res suivants doivent tre pris en compte a Installation visant r duire le bruit g n r par le fonctionnement du ventilateur L installation du ventilateur aussi loin que possible du point d entr e emp chera en partie le bruit de son fonctionnement d tre retransmis par le truchement du syst me de conduits S il est utilis comme ventilateur de renfo
4. WARNING DO NOT USE IN KITCHENS SAVE THESE INSTRUCTIONS WWW AIRKINGLIMITED COM 1 of 16 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing for Fan Installation 1 When selecting fan mounting location the following criteria should be considered a Mounting to minimize noise generated by fan operation Mounting the fan as far as possible from the intake point will minimize fan operating noise from being transmitted back through the duct work If the fan is to be used as a booster for moving the air between two rooms a central point along the duct may be optimal Insulated flexible type duct work recommended for all bathroom exhaust applications will result in much quieter operation It is recommended that a minimum 8 of insulated flexible ducting be used between any exhaust grill and fan for low noise level b Service accessibility Fan location should allow sufficient access for service SECTION 2 Installing the Fan 1 Using the 1 wood screws provided attach the fan mounting bracket to a support beam at the selected location Figure 1 V Vertical Mounting Horizontal Mounting ATA NOTE Fan mounting can be at any point along the duct and in any angle however vertical mounting is recommended to reduce condensation buildup in the fan If a horizontal installation is necessary and condensation buildup may pose a pr
5. aux roulements des moteurs et ou contacter le fabricant des h lices bruyantes ou d s quilibr es emp cher la 3 Avant d effectuer un service ou de nettoyer l unit couper poussi re de cloison s che poussi re de construction etc l alimentation lectrique dans le panneau de distribution et d atteindre l unit de puissance verrouiller le dispositif de d connexion afin d viter que 9 Acceptable pour utilisation au dessus d une baignoire ou l alimentation ne revienne accidentellement Lorsque le d une douche lorsque install dans un circuit prot g par un dispositif ne peut tre verrouill fixer solidement un avis disjoncteur de fuite de terre d avertissement tel qu une tiquette au panneau de distribution 4 Le travail d installation et le c blage lectrique doivent tre effectu s par une des personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies 5 De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles 13 NE JAMAIS placer un interrupteur un endroit qui puisse que celles publi es par la National Fire Protection Association tre atteint de la baignoire ou de la douche NFPA et de la American
6. et un fil de vivant fil noir branch au commutateur Fixez les fils lectriques au bo tier avec un connecteur lectrique approuv Assurez vous de laisser suffisamment de c blage dans le bo tier de raccordement afin de pouvoir effectuer les branchements la plaquette de connexions lectriques pr cabl e du ventilateur 3 Ins rez le fil blanc provenant de la maison dans le port de la plaquette de connexions tiquet N et serrez l aide d un petit tournevis r gulier Ins rez le fil noir partir du commutateur mural dans le port de la plaquette de connexions tiquet L et serrez l aide d un petit tournevis r gulier Etant donn que le moteur est isol au sein d un bo tier de plastique il n est pas n cessaire de proc der une mise la terre Figure 14 5S7635037 New 10 06 WWW AIRKINGLIMITED COM Alimentation provenant de la maison 4 Assurez vous que toutes les connexions de c blage sont fix es de mani re s curitaire la plaquette de connexions et replacez le couvercle du bo tier de raccordement SECTION 9 C blage du ch ssis de la grille de plafond AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE C BLAGE
7. l installation 1a Mod les avec lumi re halog ne Installez la lampe halog ne incluse en l ins rant d licatement dans la douille eten la faisant tourner jusqu ce qu elle soit bien positionn e Figure 17 1b Mod les avec lampe fluorescente Installez la lampe fluorescente quatre tiges en l ins rant d licatement dans le culot et en la poussant vers l int rieur jusqu ce qu elle soit bien positionn e Figure 17 VA a Mat riel du mur plafond Figure 17 REMARQUE La lampe fluorescente est illustr e la Figure 17 2 Installez la grille dans le ch ssis de la grille de plafond en la poussant fermement vers l int rieur vers le ch ssis jusqu ce qu elle soit effleurement du mat riau du mur ou du plafond Figure 17 3 R tablissez le courant et testez votre installation SECTION 11 Utilisation et entretien AVERTISSEMENT ASSUREZ VOUS QUE LE COURANT EST COUPE A PARTIR DU PANNEAU ELECTRIQUE AVANT DE PROCEDER A L ENTRETIEN DE LUNITE 1 Nettoyage de la grille Retirez la grille et nettoyez l l aide d un d tergent doux comme du savon vaisselle et s chez l ensuite avec un chiffon doux NE JAMAIS UTILISER DE TAMPONS ABRASIFS OU DE POUDRES A RECURER Ass chez la grille compl tement avant de la r installer Reportez vous aux instructions l tape 2 de la Section 10 pour r installer la grille 2 Les roulements du ventilateur sont scell s et munis d un mat ri
8. pas besoin d embranchement en Y Suivez les m mes directives qu l tape 1 sauf que vous raccordez l extr mit du conduit directement au ventilateur 2 Raccordez une extr mit du conduit la partie sup rieure de l embranchement en Y et l autre extr mit la prise d entr e du ventilateur Figure 11 3 Raccordez une extr mit du conduit l vacuation du ventilateur et l autre extr mit un capuchon de mur ou de plafond Figure 11 Toujours canaliser le ventilateur vers l ext rieur par le biais d un capuchon de mur ou de plafond REMARQUE Lorsqu un conduit isol flexible est utilis il est recommand de fixer l me de vinyle interne du trou d entr e et de sortie l aide d une vis de serrage ou de ruban adh sif et que le pare vapeur entourant le rev tement isolant soit fix l aide de ruban adh sif au ch ssis du ventilateur REMARQUE Lorsqu il est n cessaire de joindre un conduit flexible l ensemble collet clapet et qu un coude imm diat s av re n cessaire assurez vous qu il s agisse d un coude flexible de sorte assurer le bon fonctionnement des lames du clapet SECTION 7 Installation d un clapet d quilibrage facultatif Certains ensembles incluent un clapet d quilibrage facultatif permettant d ajuster le syst me Le clapet peut tre utilis la o les grilles seront fix es avec des conduits secondaires de longueurs in gales ou l o le d b
9. re LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OPERER OU DE R PARER LE PRODUIT D CRIT PROT GEZ VOUS M ME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE S CURIT FAILLIR SE CONFORMER AUX INSTRUCTIONS PEUT R SULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE LA PROPRI T CONSERVER CES INSTRUCTIONS POUR R F RENCES FUTURES INSTRUCTIONS G N RALES DE S CURIT Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lectrique et de blessures corporelles incluant ce qui suit AVERTISSEMENT NE PAS BRANCHER ALIMENTATION AVERTISSEMENT POUR USAGE DE VENTILATION AVANT QUE LE VENTILATEUR NE SOIT COMPLETEMENT GENERALE EXCLUSIVEMENT NE PAS UTILISER POUR EVACUER INSTALLE ASSUREZ VOUS QUE LE SERVICE LECTRIQUE SUR DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES LE VENTILATEUR EST VERROUILLE A LA POSITION ETEINTE 6 Lors de coupe ou de per age des murs et plafonds ne pas 1 Bien lire toutes les instructions avant d installer ou d utiliser endommager le filage lectrique et autres utilit s cach es le ventilateur d vacuation 7 Les ventilateurs avec conduits doivent toujours tre vacu s 2 Utiliser cette unit seulement de la mani re pour laquelle le vers l ext rieur fabricant l a con u Si vous aviez des questions veuillez 8 Pour viter des dommages
10. to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material WWW AIRKINGLIMITED COM 3 of 16 SECTION 6 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE Insulated ducting is required for bathroom exhaust applications where ducting passes through unconditioned space or where noise is a factor Failure to use insulation could result in excessive condensation buildup within the duct and undesirable sound levels within the room Duct runs should have as few bends as possible NOTE Flexible insulated ducting may be used where allowed by local code For the quietest possible installations itis recommended a minimum of 8 of insulated flexduct be used between any exhaust grill and fan When using flexible type duct work duct should be stretched as tight and straight as possible Failure to do so could result in dramatic loss of system performance Flexible duct should be connected to the fan with screw clamps or duct tape All connections should be as airtight as possible to maximize system performance 1 Connect one end of the ducting not included to the room level grill housing and the other end to the Y transition Secure both ends in place using tape or a screw clamp to create as air tight a seal as possible Repeat this step for the other room level grill housing Figure 11 Exhaust to Wall Roof Cap
11. 30 Plaque de finition AIK26YF 5576350 30 Vis 557699021 Vis Vis 5576990 21 557699023 Vis 5576990 23 Support de montage 557635035 Support de montage 5576350 35 Passe c ble 587699020 Passe cable 5576990 20 Vis 557699024 wo co gt B amp B rR gt Vis 5576990 24 Embranchement en Y AIK26YL 587635045 Embranchement en Y AIK26YF 5576350 45 Vis 587699022 N x Vis 5576990 22 Traverses de Montage 557635025 ee x Traverses de Montage 5876350 25 hassis de la grille 587635014 assis de la grille 5576350 14 C Assemblage du socle de lumi re 587635040 C Assemblage du socle de lumi re 5576350 44 557635041 s 5576350 41 Vis Grille 557635019 5876350 18 587635028 Vi Grille Ressorts pour la grille 5576350 28 Ressorts pour la grille Fil de mise la terre 587635042 Fil de mise a la terre 5576350 42 Vis de mise la terre 557635043 is de mise la terre 5576350 43 Not included with Sing Pi ces de remplacement pour la lampe halog ne ND Hy BY cof ro SB Oo OE CO NY Op oy amp Lampe halog ne de l orifice d entr e de la grille e Inlet Kit Single Inlet Kit contains
12. EMARQUE Des conduits isol s flexibles peuvent tre utilis s l o le code local le permet Pour des installations au niveau de sonorit le plus bas possible il est recommand d utiliser au moins 2 44 m de conduit flexible entre toute grille d chappement et ventilateur Lors de l utilisation de syst mes de conduit de type flexible le conduit devrait tre tir aussi serr et droit que possible Le cas contraire pourrait entrainer une baisse dramatique de rendement du syst me Le conduit flexible devrait tre rattach au ventilateur l aide de serre joints ou de ruban conduits Toutes les connexions devraient tre aussi tanches que possible afin de maximiser le rendement du syst me 1 Raccordez une extr mit du conduit non inclus au collet clapet au niveau de la pi ce et l autre extr mit a l embranchement en Y Fixez les deux extr mit s en place en utilisant du ruban ou un serre joint afin de cr er un joint aussi tanche que possible R p tez cette tape pour le ch ssis de la grille de l autre pi ce Figure 11 5S7635037 New 10 06 WWW AIRKINGLIMITED COM Evacuation vers le capuchon du mur plafond 1 Ventilateur TN Embranchement en a Y LLA Ch ssis de la grille N P Conduit Figure 11 REMARQUE Les unit s qui incluent un seul collet n ont
13. IRKINGLIMITED COM Support REMARQUE Le support est muni de passe c bles isol s en caoutchouc pour la vibration afin d emp cher la transmission du son par le truchement de la structure Prenez soin de ne pas trop serrer De plus assurez vous de ne pas d nuder la gaine de plastique Les vis sont autotaraudeuses et ne requi rent pas d avant trous Cependant des avant trous n exc dant pas 1 52 mm peuvent tre utilis s afin de faciliter l installation SECTION 3 Pr paration pour l installation du ch ssis au plafond 1 Choisissez un emplacement pour l orifice d entr e de la grille qui n interf rera pas avec une solive de plafond Le ch ssis de la grille peut tre install directement sur la solive par le truchement des trous de serrure situ s sur le c t du ch ssis ou au milieu des solives 406 4 mm en vous servant des traverses de montage incluses 2 Enlevezle couvercle de l alv ole d fon able lectrique ou l une des autres alv oles d fon ables sur le ch ssis de la grille en vous servant d un tournevis lame plate Figure 3 Couvercle de l alv ole d fon able SECTION 4 Nouvelle construction 1 Installation des traverses de montage Installez les traverses travers le ch ssis de la grille et placez les c t de la solive En vous aidant des onglets de rep re situ s sur le ch ssis alignez les de sorte ce qu ils soient effleurement de la pa
14. LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Retirez les vis de l int rieur du ch ssis qui retiennent le couvercle lectrique en place Figure 15 Couvercle Figure 15 2 Passezle c blage d un calibre appropri partir d un commutateur mural approuv Un fil de connexion de neutre blanc et un fil de vivant fil noir branch au commutateur Fixez les fils lectriques au bo tier avec un connecteur lectrique approuv Assurez vous de laisser suffisamment de c blage dans le bo tier de raccordement afin de pouvoir effectuer les branchements la plaquette de connexions lectriques pr cabl e du bo tier 3 A partir de l endroit d o vous avez acc s l int rieur de la bo te de connexion branchez le fil blanc partir du bo tier au fil blanc du socle de lumi re Branchez le fil noir partir de l interrupteur mural au fil noir du socle de lumi re Connectez le fil de mise la terre provenant de la maison au fil vert la vis de mise la terre Figure 16 Utilisez des m thodes approuv es pour toutes les connexions 13 of 16 ee PS Fil de Masse Fil Chaud Noir Cc Pa o lt provenant de la maison 4 Installez nouveau le couvercle lectrique en vous assurant que tous les fils sont bien rentr s l int rieur du bo tier et qu ils ne seront pas pinc s SECTION 10 Finaliser
15. MITED COM Solution Sugg r e Un fusible peut tre grill ou un disjoncteur peut tre d cle nch 1a Remplacer le fusible ou r initialiser le disjoncteur Couper l alimentation de l unit V rifier que tous les fils sont raccord s Remplacez la moteur rifier pour toute obstruction dans les conduits Les plus courantes sont des s d oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue vacue vers l ext rieur Le r glage de la commande de vitesse n est pas assez lev Si une commande de vitesse est utilis e confirmez le r glage Coupez l alimenta branch s correcte ati uper l alimen unit Retirer la grille et v rifier que toutes les vis sont AE serr es Remettre l alimentation sur l unit ion de l unit Assurez vous que tous les fils sont Les vis pour l installation du ventilateur sont trop serr es Coupez l alimentation de l unit Desserrez les vis des passe c bles en caoutchouc Communiquez avec le vendeur pour un remplacement 14 of 16 GARANTIE LIMIT E Tous les produits fabriqu s par Air King Limited sont garantis pour un an partir de la date d achat contre les d fauts de main d uvre et ou de mat riel De plus tous les ventilateurs vacuateurs chaufferettes combin s ventilateur lumi re et ou les chaufferettes et les hottes de cuisine sont garantis pour cinq ann es partir de la date d achat contre les d
16. Models AIK14XL AIK26YL AIG46HL AIG46F AIK14XF AIK26YF IMPORTANT INSTRUCTIONS OPERATING MANUAL e e Ventilation Products E In Line Exhaust Fan with Light READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following WARNING DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED MAKE SURE ELECTRICAL SERVICE TO THE FAN IS LOCKED IN OFF POSITION 1 2 Read all instructions before installing or using exhaust fan Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standar
17. amp Halogen Lamp Not included with Single Inlet Kit Single Inlet Kit contains half of number listed Halogen Lamp Grill Inlet Replacement Parts Description 557699 Replacement Part 5 2 5 4 0 987635041 9 8 2 3 6 Ground Screw 58763504 00 Screw 557699 Fluorescent Lamp Description 55769900 Not included with Single Inlet Kit Single Inlet Kit contains half of number listed Fluorescent Lamp Grill Inlet Replacement Parts Replacement Part 022 Mounting Rail 557635 Screw 987699022 025 Grill Housing 557635 Mounting Rail 987635025 014 Light Socket Assembly 587635 Grill Housing 987635014 04 Screw 557635 Light Socket Assembly 58763504 04 Grill 5S7635 Screw 98763504 0 Grill Spring 557635 5876350 Ground Wire 557635 ill Spring 98763502 02 04 Ground Screw 557635 Ground Wire 98763504 04 Ny on BR co Nh Slo ess Halogen Lamp 5S7635037 New 10 06 557699 Ground Screw 58763504 00 WWW AIRKINGLIMITED COM 8 Rl Rte Fluorescent Lamp 58769900 8 of 16 INSTRUCTIONS IMPORTANTES MANUEL D OPERATION Mod les AIK14XL AIK26YL HinKing Ventilateur d vacuation en AIG46HL AIG46F AIK14XF AIK26YF herte Boon me s rie avec lumi
18. de If a speed control is being used confirm the setting Turn off power to unit Check that all wires are connected correctly Speed control not set high enough Incorrect wiring 3 Fan is operating louder than normal Motor is loose Turn off power to unit Confirm unit is mounted securely to bracket Restore power to unit Fan mounting screws too tight Turn off power to the unit Loosen screws going through rubber grommets Fan damaged in shipping Contact seller for replacement 5S7635037 New 10 06 WWW AIRKINGLIMITED COM 6 of 16 LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and or material In addition all ventilating exhaust fans heaters combination fan lights and or heaters and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and or material This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as range hood grease filters charcoal filters or combination charcoal grease filters replacement light bulbs in range hoods or bathroom fan light bulb heater combinations As well any damage or failure caused by abuse misuse abnormal usage faulty installation or improper maintenance will not be covered by this warranty In order to make a claim on this warranty you must b
19. ds including fire related construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS 5S7635037 New 10 06 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit Suitable for use with solid state speed control This unit has rotating parts and safety precautions should be exercised during installation operation and maintenance Guards must be installed when fan is within reach of personnel or within seven 7 feet of working level or when deemed advisable for safety NEVER place a switch where it can be reached from a tub or shower Do not insert or allow fingers or foreign objects to enter the motor
20. e the original consumer of the product You will be required to present to Air King the original bill of sale showing date of purchase place of purchase and model purchased Failure to meet these requirements will void your warranty Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of the product when you call For more information please visit our website wwwairkinglimited com Installer Installation Date Place of Purchase Model Number 5S7635037 New 10 06 WWW AIRKINGLIMITED COM 7 of 16 REPLACEMENT PARTS DIAGRAM THTTTT TTTTTT Halogen Lamp Fan Kit Replacement Parts Description ie o V7 Replacement Pa
21. el lubrifiant interne aucune lubrification additionnelle n est requise AVERTISSEMENT LAISSEZ LA LAMPE REFROIDIR AVANT DE LA REMPLACER 3 Remplacement de la lampe Coupez l alimentation de l unit Retirez la grille en tirant vers l ext rieur partir du mur ou du plafond Mod les halog ne Retirez la lampe en la faisant doucement tourner jusqu ce qu elle se lib re de la douille et remplacez la avec une lampe Air King mod le 50WHA ou quivalent de 50 watts MR16 120 volts EXN GU10 Figure 17 Mod les fluorescents Retirez la lampe en la faisant balancer doucement tout en tirant vers l ext rieur jusqu ce qu elle se lib re de la douille et remplacez la exclusivement avec une lampe Air King mod le 14WFW Figure 17 Reportez vous aux instructions de la Section 10 pour finaliser l installation pour changer la lampe ainsi que pour l installation de la grille Guide de d pannage Trouble Cause Possible 1 Le ventilateur ne fonctionne pas lorsque l interrupteur est la position en marche Le c blage n est pas raccord correctement La moteur est terminee 2 Le ventilateur fonctionne mais l air Obstruction dans les conduits d vacuation circule plus lentement que la normale C blage incorrect 3 Le ventilateur fonctionne de mani re Le moteur est l che plus bruyante que la normale Ventilateur endommag au cours de l exp dition 5S7635037 New 10 06 WWW AIRKINGLI
22. g outward from wall or ceiling Halogen Models Remove the lamp by gently rotating until it releases from the socket and replace with Air King model 50WHA or an equivelent 50 watt MR16 120 volt EXN GU10 2 Install the grill into the ceiling grill housing by pushing it firmly inward towards the housing until it fits flush against the ceiling lamp Figure 17 or wall material Figure 17 Fluorescent Models Remove the lamp by gently rocking 3 Restore power and test your installation back and forth while applying outward pressure until it releases from the socket and replace with Air King model 14WFW only Figure 17 Refer to instructions in Section 10 Completing the Installation to complete the lamp change and installation of grill SECTION 11 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT Troubleshooting Guide Probable Cause fuse may be blown or a circuit tripped Wiring is not connected properly Motor has stopped operating Trouble 1 Fan does not operate when the switch is on Suggested Remedy Replace fuse or reset circuit breaker Turn off power to unit Check that all wires are connected Replace motor 2 Fan is operating but air moves slower than normal Obstruction in the exhaust ducting Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outsi
23. half of number listed de remplacement 587699006 Not included with Sing Lampe fluorescente 5576990 e Inlet Kit Single Inlet Kit contains half of number listed Pi ces de remplacement pour la lampe fluorescente de l orifice d entr e de la grille de pi ce 2 D Description de pi de remplacement 05 ce Description Vis 587699022 Vis 5576990 22 Traverses de Montage 557635025 Traverses de Montage 5576350 25 ssis de la grille 557635014 ssis de la grille 5576350 14 C Assemblage du socle de lumi re 5S7635040 C Assemblage du socle de lumi re 5576350 44 S 557635041 S 5876350 41 587635019 5576350 18 essorts pour la grille 587635028 essorts pour la grille 5576350 28 Vi Grille R F de mise la terre 587635042 V Grille R F de mise la terre 5576350 42 Vis de mise la terre 557635043 Vis de mise la terre 5576350 43 557635037 New 10 06 8 9 0 11 2 13 4 15 6 17 Lampe halog ne 587699006 WWW AIRKINGLIMITED COM Rp Ay a Lampe fluorescente 5576990 05 16 of 16
24. he branch with the least restriction This is generally the duct that is shortest or has the fewest bends 2 Drill a 5 16 hole approximately 1 1 2 from the edge on the flat side of the Y transition 3 Insert the shaft of the damper into the hole drilled in step 2 Place the washer handle then wing nut onto the shaft Figure 12 Wing Nut Washer anale Y Transition _ Figure 12 4 Adjust the damper to balance airflow and tighten the wing nut to secure SECTION 8 Wiring the Fan CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION 4 of 16 CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the screws securing the terminal box cover plate located on the side of the motor Figure 13 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral white and one hot black lead connected to the switch Secure the electrical wires to the housing with an approved electrical connector Make sure you leave enough wiring in the terminal box to make the connections to the fan s pre wired electrical terminal strip 3 Insert the white wire from the house into the terminal strip portlabeled N and tighten using a small regular sc
25. it devra tre quilibr pour une raison ou une autre Pour installer le clapet en option 1 Le clapet doit tre install sur la branche secondaire la plus facilement accessible Il s agit habituellement du conduit le plus court ou de celui avec le moins de coudes 2 Percez un trou de 7 94 mm environ 38 1 mm du bord sur le c t plat de l embranchement en Y 12 of 16 3 Ins rez l arbre du clapet dans le trou perfor l tape 2 Placez la rondelle la poign e et ensuite l crou oreille dans l arbre Figure 12 Ecrou c oreille Poign e Rondelle_ 9 Embranchement en si Y mw Figure 12 4 Ajustez le clapet de sorte a quilibrer le d bit d air et serrez l crou a oreille pour le fixer en place SECTION 8 Cablage du ventilateur AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Retirez les vis de la plaque du couvercle de la bo te de raccordement situ e sur le c t du moteur Figure 13 Bo te de raccordement 2 Passez le c blage d un calibre appropri partir d un commutateur mural approuv Un fil de connexion de neutre blanc
26. light socket Connect the black wire from the wall switch to the black wire from the light socket Connect the ground wire from the house to the green wire from the grounding screw Figure 16 Use approved methods for all connections Ground Hot Black 4 Re install the electrical cover making sure all wires are tucked inside the box and are not being pinched SECTION 10 Completing the Installation 1a Halogen Light Models Install the included halogen lamp by gently inserting into the socket and turning the lamp until it is properly seated within the socket Figure 17 1b Fluorescent Light Models Install the included 4 pin fluorescent lamp by gently inserting into the socket and pushing inward until the lamp is properly seated within the socket Figure 17 WWW AIRKINGLIMITED COM 5 of 16 Ceiling Wall Lamp Figure 17 QD a NOTE Fluorescent lamp is shown in Figure 17 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 10 Completing the Installation to reinstall grill The fan s bearings are sealed and provided with an internal lubricating material no additional lubrication is necessary CAUTION ALLOW LAMP TO COOL BEFORE REPLACING 3 Changing the Lamp Disconnect power to the unit Remove the grill by pullin
27. nto the final position Figure 4 WWW AIRKINGLIMITED COM 2 of 16 A L lt gt Housing l 7 Locating Tabs p B Mountin Figure 4 NOTE If drywall or ceiling material will be thicker than 5 8 the height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material 2a Keyhole Installation Using a straight bladed screw drive punch out the two keyhole slot knockouts on the side of the housing that will be attached to the joist Figure 5 I Keyhole Knockouts 2b Using the locator tabs on the grill housing line up housing so that it will be flush with the finished ceiling Position the housing so that the tabs rest flat against the joist and secure with the included 1 screws through the two keyhole slots Figure 6 Zan Joist Housing Housing Dy TN Locating Tab Keyholes Figure 6 NOTE If drywall or ceiling material will be thicker than 5 8 the height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material SECTION 5 Existing Construction 1 Mounting Rail Installation Determine where the grill will be moun
28. oblem wrap insulation around the fan to minimize buildup 2 Attach fan to the mounting bracket with the three 7 16 sheet metal screws provided making sure the wiring box is positioned for easy access Figure 2 587635037 New 10 06 NOTE Bracket is provided with rubber vibration isolation grommets to prevent the transmission of sound through the structure Be careful not to over tighten Also care should be taken not to strip the plastic housing Screws are self tapping and do not require pilot holes Pilot holes no larger than 1 16 can be used to ease the installation however SECTION 3 Preparing for Ceiling Housing Installation 1 Choose a location for the inlet grill that will not interfere with a ceiling joist The grill housing can be mounted directly to the joist through the keyholes on the side of the housing or between 16 on center joists using the provided mounting rails 2 Remove the electrical knockout cover or one of the other electrical knockouts on the grill housing using a straight blade screw driver Figure 3 Knockout Cover SECTION 4 New Construction 1 Mounting Rail Installation Install the rails through the grill housing and position next to the joist Using the locator tabs on the housing line up tabs so that they are flush with the bottom of the joist Secure the ends of the rails with the provided 1 screws to the joists and slide the housing i
29. rewdriver Insert the black wire from the wall switch into the terminal strip port labeled L and tighten using a small regular screwdriver Since the motor is isolated within a plastic housing grounding is not necessary Figure 14 Supply from house poy joe g 4 Check to make sure all wire connections are securely fastened to the terminal strip and replace the fan terminal box cover SECTION 9 Wiring the Ceiling Grill Housing CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION 5S7635037 New 10 06 CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the screws inside the housing securing the electrical cover in place Figure 15 Housing 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral white and one hot black lead connected to the switch Secure the electrical wires to the housing with an approved electrical connector Make sure you leave enough wiring in the terminal box to make the connections to the housing s pre wired electrical terminal strip 3 From where you have access to inside the housings junction box connect the white wire from the house to the white wire from the
30. rt Motor AIK14XL 987635038 o T OR O Di Description Fluorescent Lamp Fan Kit Replacement Parts Replacement Part Motor AIK26YL 987635002 Motor AIK14XF 987635038 Cover Plate AIK14XL 987635029 Motor AIK26YF 987635002 Cover Plate AIK26YL 987635030 Cover Plate AIK14XF 987635029 Screw 987699021 Cover Plate AIK26YF 587635030 Screw 987699023 Screw 987699021 Mounting Bracket 587635035 Screw 987699023 Grommet 987699020 Mounting Bracket 987635035 Screw 987699024 Grommet 587699020 Y Transition AIK26YL 58763504 wluw R nol Screw 987699024 Screw 557699 Y Transition AIK26YF 587635045 02 Mounting Rail 55763502 N x Screw 987699022 Grill Housing 9876350 ee Mounting Rail 987635025 Light Socket Assembly 98763504 Grill Housing 587635014 Screw Light Socket Assembly 98763504 9876350 Screw 98763504 Grill Spring 98763502 Grill 9876350 Ground Wire 58763504 Grill Spring 98763502 Ground Screw 58763504 Ground Wire 58763504 QD HB cI Slo Ole N Ojo
31. rt pour assurer la distribution d air entre deux pi ces un point central au long du syst me de conduit pourrait s av rer optimal Un syst me de conduit flexible isol recommand pour toutes les installations de ventilateurs dans les salles de bain procurera un fonctionnement beaucoup plus silencieux Il est recommand d utiliser au moins 2 44 m de gaine flexible entre toute grille d chappement etle ventilateur pour minimiser le niveau de bruit b Accessibilit pour l entretien L emplacement du ventilateur devrait pr voir un acc s suffisant pour l entretien SECTION 2 Installation du ventilateur 1 En vous servant des vis bois de 25 mm incluses fixez le support de montage un montant de support l emplacement choisi Figure 1 Installation verticale Installation horizontale REMARQUE Le ventilateur peut tre install l emplacement de votre choix le long du conduit cependant une installation verticale est recommand e afin de minimiser l accumulation de condensation dans l unit Dans le cas o une installation horizontale s av re n cessaire et que l accumulation de condensation pourrait occasionner un probl me enveloppez le ventilateur d isolant afin d en minimiser l accumulation 2 Fixezle ventilateur au support de montage en utilisant les trois vis t le de 1 11 mm incluses en vous assurant que la bo te de c blage soit facilement accessible Figure 2 5S7635037 New 10 06 WWW A
32. rtie inf rieure de la solive Fixez l extr mit des traverses aux solives en vous servant des vis de 25 4 mm incluses et faites glisser le ch ssis en position finale Figure 4 10 of 16 Onglets de localisation Figure 4 raverses de montage Ly REMARQUE Si l paisseur de la paroi s che ou du mat riel du plafond est de plus de 15 88 mm la hauteur du ch ssis devra tre ajust e pour compenser et les onglets de rep re pli s galit du ch ssis de sorte que le collet de la grille soit effleurement du mat riel de plafond final 2a Installation l aide des trous de serrure En vous servant d un tournevis lame plate perforez les deux trous de serrure des alv oles d fon ables du ch ssis qui seront fix es la solive Figure 5 Trous de serrure des lt alv oles d fon ables 2b En vous servant des onglets de rep re situ s sur le ch ssis de la grille alignez ce dernier de sorte qu il soit effleurement du plafond final Placez le ch ssis de sorte ce que les onglets reposent plat sur la solive et fixez les vis de 25 4 mm incluses dans les deux trous de serrure Figure 6 TT Solive Ch ssis Ch ssis gt N gt Onglets de localisation Figure 6 Trous de serrure REMARQUE Si l paisseur de la paroi s che ou du mat riel du plafond es
33. stall e au long de la solive en commen ant 3 17 mm de la solive d coupez une ouverture circulaire de 152 4 mm en faisant attention de ne pas couper ou endommager des composantes lectriques ou tout autre mat riel dissimul Figure 9 Placez le collet du ch ssis de la grille dans l ouverture d coup e de sorte qu elle soit effleurement du plafond final Figure 10 Fixez le ch ssis de la grille la solive en ins rant les vis de 25 4 mm incluses dans les deux trous de serrure Figure 6 11 of 16 REMARQUE Si l paisseur de la paroi s che ou du mat riel du plafond est de plus de 15 88 mm la hauteur du ch ssis devra tre ajust e pour compenser et les onglets de rep re pli s galit du ch ssis de sorte que le collet de la grille soit effleurement du mat riel de plafond final SECTION 6 Conduit AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AVEC LES CODES DU BATIMENT LOCAUX ET NATIONAUX REMARQUE Un conduit isol est requis pour les installations d vacuations de salles de bain lorsque le conduit passe par un emplacement non climatis ou dans un emplacement o le bruit repr sente un facteur important Le fait de ne pas utiliser d isolant pourrait entra ner une accumulation excessive de condensation au sein du conduit de m me qu un niveau de sonorit ind sirable dans la pi ce Les courses de conduits devraient pr senter aussi peu de coudes que possible R
34. t de plus de 15 88 mm la hauteur du ch ssis devra tre ajust e pour compenser et les onglets de rep re pli s galit du ch ssis de sorte que le collet de la grille soit effleurement du mat riel de plafond final 5S7635037 New 10 06 WWW AIRKINGLIMITED COM SECTION 5 Construction Existante 1 Installation des traverses de montage D terminez l emplacement de la grille et d coupez une ouverture circulaire de 152 4 mm en faisant attention de ne pas couper ou endommager des composantes lectriques ou tout ou autre mat riel dissimul Figure 7 Installez les traverses sur le ch ssis et placezle collet du ch ssis de la grille dans l ouverture d coup e de sorte qu elle soit effleurement du plafond final Figure 8 Fixez les extr mit s des traverses aux solives Figure 4 Traverses de montage Figure 8 Ch ssis de la grille REMARQUE Si l paisseur de la paroi s che ou du mat riel du plafond est de plus de 15 88 mm la hauteur du ch ssis devra tre ajust e pour compenser et les onglets de rep re pli s galit du ch ssis de sorte que le collet de la grille soit effleurement du mat riel de plafond final 2a Installation l aide des trous de serrure En vous servant d un tournevis lame plate perforez les deux trous de serrure des alv oles d fon ables du ch ssis qui seront fix es la solive Figure 5 2b D terminez l emplacement o la grille sera in
35. tat l autre et d une province l autre POUR DES PIECES OU DE L ASSISTANCE TECHNIQUE Veuillez appeler au 1 800 465 7300 DU LUNDI AU VENDREDI ENTRE 8 00 HRE ET 16 00 HRE HNE VEUILLEZ NE PAS RETOURNER CE PRODUIT A LENDROIT DE L ACHAT D ORIGINE R f rencer le type et le style du produit localis sur l tiquette l int rieur du produit lorsque vous appelez Pour plus d information veuillez visiter le site Web de Air King au www airkinglimited com Installateur Date d installation Endroit de l achat Num ro de mod le 5S7635037 New 10 06 WWW AIRKINGLIMITED COM 15 of 16 DIAGRAMME DES PI CES DE REMPLACEMENT THTTTT TTTTTT 8 Pi ces de remplacement pour ensemble de ventilateur lumi re halog ne Description de remplacement ie o V7 de pi ce q T OR O ES Description Pi ces de remplacement pour ensemble de ventilateur lampe fluorescente de pi de remplacement ce Moteur AIK14XL 557635038 Moteur AIK26YL Moteur AIK14XF 5876350 38 987635002 Moteur AIK26YF 5876350 02 Plaque de finition AIK14XL 5S7635029 Plaque de finition AIK26YL Plaque de finition AIK14XF 5576350 29 5876350
36. ted and cut a 6 round opening being careful not to cut or damage any electrical or other hidden utilities Figure 7 5S7635037 New 10 06 Install the rails on the housing and position the housing grill collar in the previously cut hole so that it is flush with the finished ceiling Figure 8 Secure the ends of the rails to the joists Figure 4 Housing Grill Collar Figure 8 NOTE If drywall or ceiling material will be thicker than 5 8 the height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material 2a Keyhole Installation Using a straight bladed screw drive punch out the two keyhole slot knockouts on the side of the housing that will be attached to the joist Figure 5 2b Determine where along the joist the grill will be mounted and starting 1 8 away from the joist cut a 6 round opening being careful not to cut or damage any electrical or other hidden utilities Figure 9 Position the housing grill collar in the previously cut hole so that it is flush with the finished ceiling Figure 10 Secure the grill housing to the joist using the provided 1 screws through the two keyhole slots Figure 6 NOTE If drywall or ceiling material is thicker than 5 8 the height of the housing will need to be adjusted to compensate and the locator tabs will need

Download Pdf Manuals

image

Related Search

Related Contents

OmniChaPE 188  1050 Series of HPLC Modules Service Handbook  Samsung BF62TCST Uživatelská přiručka  Manuel de l`opérateur  Koji Manual  USER FONT MAKE    取扱説明書  362k PDF - Theoretical Biophysics Group  The Delivery Hub health, safety and environment Raising the bar 3  

Copyright © All rights reserved.
Failed to retrieve file