Home

Aiphone MYW-BA User's Manual

image

Contents

1. 83349900 0496 o AIPHONE PanTilt entry security system LONG DISTANCE ADAPTOR mode MYW BA INSTALLATION amp OPERATION MANUAL SYSTEM OUTLINE amp FEATURES PanTilt video system has limited its applications within a distance of 100m 330 MYW BA is capable of expanding wiring distance of PanTilt door station more than 100m and up to 300m 330 to 980 in MY 1CD or MY 2CD monitor station systems Versatile TD H B or LEF systems combined with MY CU monitor may have PanTilt door communication systems using each door video adaptor SYSTEM LAYOUT EXAMPLE Operates on 2 conductors to PanTilt door station O O 300m max w 1 2mm dia PS PS 18D or PS 18C 980 w 16 AWG FEATURES vx Works with the following PanTilt entry security systems MY 1CD Video Sentry PanTilt MY 2CD Video Sentry PanTilt Plus MY CU with TD H B selective call system _ MYH CU with LEF 10 open voice selective call system yx One to max 3 video entries One MYW BA is required per entry yx Powered by a single power supply PS 18D 18C of using MY video system A separate power supply locates MYW BA max 50m 165 away from the monitor station Check the package contents before installation Long distance adaptor MYW BA 1 unit Screws pack 1 set Installation amp Operation Manual NAMES AND FUNCTIONS li Opening for the cable Connector yy A Pa Lift and pull away ra Mounts on single gang box with 83 5mm
2. 4 Hi sag 3 5 16 guide fo iP om iy Ea a To inside monitor E Br j e fey J fi ap I V T To PanTilt door station AJ MYW BA li 9 To PS 18D 18C power supply Front screw ae j Do not cross wire Opening for ace the cable ae e 3 INSTRUCTIONS ON INSTALLATION amp WIRING MYW BA is a video wiring adaptor for indoor use only Its mounting location must be in the same category as described in the Manuals of using video monitor On a specified pair wires audio amp video communication is stable and unaffected and pan and tilting operation of door camera is flexibly smooth at max 300m 980 distant entry The MYW BA performance depends on the cable and distance to PanTilt door station and also to inside monitor s The below specifications must be met for using wires on Insulation with PE Polyethylene MYW BA adaptor Never with er chloride J AA A Impedance 90 ohm AN Permitted closed loop DC resistance O N yee 9 9 ohm or less wee Insulation must not be PVC but PE oe ayaa Bare copper conductor PE or PVC In USA cable type West Penn D990 or equivalent 1 2mm for 300m Installation of non specified cable and or within 100m 330 or over 300m 980 distance may cause inferior imaging or incomplete call While making wire terminations front case may be set aside plugging off connector Refrain from doing so when the
3. 5 10 10S with MYH CU video monitor s MY DC A MYW BA MYW P1L MYH CU Observe polarity LEF 5 PS 18D _ PS 18C lt D m on Au NE l lt x Dmnpo A Ol i if ar I lt Dmowoeo A Bn ay HW ME A i lt Dmaa Bon ji EE TT on I lt Dmeoaawnp aN i K5 KS K5 Terminals L and K1 K4 control are not shown LEF W terminal box is not provided with K1 K5 control terminals Wiring Single pair cable to PanTilt door station It is also suggested to specify the same type for wiring to monitor s which is separated from LEF audio wiring Wiring distance MYW BA to PanTilt door station Diameter 1 0mm 1 2mm AWG 18AWG 16AWG Distance 200m 300m Distance 650 980 MYW BA to MYW P1L monitor s Diameter 1 0 or 1 2mm AWG 18 or 16AWG Distance 50m Distance 165 One power supply PS 18D 18C suffices for one MYW BA connected MYW P1L system with one MYH CU monitor Max distance from MYW P1L to a video monitor farthest is 75m w 1 0mm dia 245 w 18AWG Refer to the MYW P1L Manual for non MYW BA used system examples SPECIFICATIONS Power source MYW BA DC 18V Can be powered by a PS 18D PS 18C in North America of using PanTilt monitor system Replaces PS 18YD A PS 18YC A in MY 1CD system Current consumption 250mA 1mA standby Cable requirements Use specified cable to each PanTilt door station and
4. Monitor station video adaptor Impedance 90 ohm Permitted closed loop DC resistance 9 9 ohm or less Insulation must not be PVC In USA cable type West Penn D990 or equivalent Wiring Total 6 conductors run from MYW BA to video trunkage line 2 conductors to PanTilt door station and 2 to using main monitor MY 1CD MY 2CD or MY CU in TD 6 12 24 H system In LEF 5 10 10S the same 2 conductors to MYW P 1 3 L video adaptor The rest 2 conductors go to the system s power supply PS 18D 18C or its own Wiring Distance MYW BA to PanTilt door with specified cable Diameter 1 0mm 1 2mm AWG 18AWG 16AWG Distance 300m Distance 650 980 MYW BA to video monitor main or MYW P 1 3 L Diameter 1 0 or 1 2mm AWG 180r16AWG Distance 50m Distance 165 MYW BA to power supply Diameter 1 0mm 1 2mm AWG 18AWG 16AWG Distance 7m 10m Distance 23 33 Dimensions H x W x D 190 mm x 80 mm x 42 mm 7 1 2 x 3 x 1 5 8 Weight Approx 210g 0 46 ibs This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful _ interfer
5. system power supply is turned on amp Wiring on MYW BA must be strictly in accordance with diagrams on page 3 4 amp 5 Incorrect connection of PS 18D 18C power supply causes damage to the unit System possibilities According to system size amp station capacity required select a best suited from the followings MY 1CD MY 2CD Basic one entry PanTilt system can be an important entry check MY 2CD monitor station control entry at 2 PanTilt door stations system MYW BA MY DC A MY 2CD MYH 2CD MY DC A MY CU with TD 6 12 24 H B One PanTilt door one monitor or two and multiple TD H phone stations MYH CU with LEF 5 10 10S One Pantiit door one monitor or two and multiple LEF open voice stations PanTilt MYH CU 3 camera system with LEF 10 MYW PSL adaptor provides LEF 10 with PanTilt door communication capabilities including visual checking of 3 entries and selected entry listening with its image eucricad viewing cam nals Si D The above example illustrates 2 PanTilt door stations and an overhead viewing camera MY CA in MYW CA are connected to 7 call LEF 10 system MOUNTING LEF 10 LEF 10 Loosen a front bottom screw and open the front case sliding front case upward from me chassis Unplug the connector from the chassis and set aside the front main unit The chassis mounts to wall with 83 5mm 3 5 16 pitched Make wire terminations on
6. 4 screw terminals then DC18V wires from power supply Reconnect and attach the front case to chassis and tighten the bottom screw gt WIRING MY 1CD long distance application MY 1CD is basic 1 door 1 monitor PanTilt system With an MYW BA added MY 1CD now communicates with PanTilt door station at gate which is 300m 980 away PantTilt door station gt MY DC A S 300m 1 2mm dia 980 16AWG 1 l Observe polarity Ea Ln PS S 18D 18C MY 2CD 2 PanTilt door long distance application MY 2CD matches for the system with 2 PanTilt doors One MYH 2CD sub monitor max 2 may be added featuring same operations as on main monitor and audio video monitoring independently operable Pan tilt door station MY DC A 300m 1 2mm dia 980 16AWG Main monitor Sub monitor MYW BA MY 2CD MYH 2CD Observe polarity i Saat B1 A1 Bi Tee 1A1 1A2 B2 1A2 E PS 18D 18C I t l Swi a l G mae i SW1 2A2 l Total of 6 conductors w 2 each wires on terminals TD H A one PanTfilt entry long distance application TD 6H B TD 6H B TD 6H B ae aaa ia MY CU amp DE UR TD 6HIB PantTilt door station MY DC A TD H Communication i f i TD H trunkage line 3 common No of FD H PanTilt M
7. Y video door stations 2 to MY CU PS 18D or PS 18C PS12 PS 12A or PS 12C TD H A multiple station is capable of connecting PanTilt door station in conjunction with DE UR adaptor For long distance application locate MYW BA adaptor between PanTilt door station and MY CU monitor me ei i i a u MY CU amp PanTilt door station MY DC A e m mm oe i TD 6H B TD 6H 8 TD 6H B TD 6H 8 l i l E Wiring Single pair conductors to PanTilt door station Single pair conductors to MY CU main monitor MYW BA powered by PS 18D 18C power supply of MY CU video system Wiring distance MYW BA to PanTilt door station Diameter 1 0mm 1 2mm AWG 18AWG 16AWG Distance 200m 300m Distance 650 980 A separate power supply locates MYW BA within max 50m 165 distance to MY CU monitor with 1 0 or 1 2mm dia 18 or 16AWG while it must be power sourced separately LEF 5 one PanTfilt entry long distance application MYH CU amp MYCIN 0 FS See Se E R MYW BA MYW P1L o PS12 20 terminals LEFAUDIO gt i LEF trunkage line SSH AE NE and 5 common No of LEF master PanTilt door i stations i Y PS18 PS 18D or PS 18C VIDEO CONTROL A 7 A PS12 P8 12A or PS 12C H A1 A2 01 U2 B1 B2 8 terminals MYW P1L connects one PanTilt door to LEF
8. ence to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the __useris encouraged to try to correct the interference by one or more of the following measures baer a cr ee Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver is _ connected Increase the separation between the equipment and receiver Consult the dealer or an experienced radio TV technician forhelp ae a ae T 4 A ee hat sit ele ele she fe ole ole je ofe oje oje ole ofe oje ote elo lo ofo ofo ofe ofo ole ele ofe ofe ofe ols oie sfe oje se ole ofa ofo afe ofe sta ofe ofe oje ole oje ope ofe ole ole efo ofo sgo aje afe afe afe ofe aja ate ofe afe ope ofe ope ofa fo afe Aiphone Co Ltd Nagoya Japan Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a P epr ppr EEE EEE et she eje oje oje ejo she ole eje ejo of oje oje ojo ole oje oje ojo ofe ole sfe ole ofe ole ofe ole ole ele ofe ole ate efe ofe eje efe sfo tfe ole oto ofe ste ole sfe sfo oje ole ofo ole sfe ejo ole ole ote ote oto ofo oje ele ele ofe ofe ofe ote WARRANTY period of two years after delivery to the ultimate user and will repai
9. r free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls PEPEEEEAEEE EEE EE EES Aiphone Corporation Bellevue WA USA MYW BA I E 0496G gt COMMUNICATION SYSTEMS HOME BUSINESS INDUSTRY Printed in Japan E

Download Pdf Manuals

image

Related Search

Related Contents

BWO 155 SL Manual de instrucciones original  18 EXPLICACIÓN DE SÍMBOLOS Advertencias de seguridad para  Miele FN 14827 S ed  HP WX408AA mice  Samsung P2250 Uživatelská přiručka  - CONRAD Produktinfo.  SOYO SY-6BA+ User's Manual  VC 40 S 9111 D-GB:VLG45 Entwurf.QXD.qxd  IC Intracom 506540 KVM switch  EECS Navigation System Manual  