Aico 160 Series User's Manual
Contents
1. Helpline on 0870 758 4000 or visit u osu our website www aico co uk and download our product information
2. apartments and HMOs e Easi fit technology saves time and money on every installation Fixed cost interconnection Wire free interconnection and zoning capability Fully upgradeable system future proof Reliable interconnection Minimises risk of accidental mis wiring No false alarms from normal electrical transients Range of optional system control devices RadioLINK uses tried tested and proven radio transceiver technology e Use with Fil6ORC Series alarms already proven iN millions of installations nationwide Code Description Ei 168RC RadioLINK Interconnect Base Ei428 RadioLINK Remote Relay Ei411H Wireless Remote Control Switch with Hush Ei407 Wireless Remote Manual Call Point Ei410 Wireless Remote Control Interconnection es SMOKE amp HEAT AAMS The Eil668RC RadioLINK Base Unit At the heart of the RadioLINK system are the Fil68RC base units which are fully compatible with any Fil60RC Series alarm It is from these that radio signals are transmitted and received An Ei168RC base is required for each of the alarms in the system Mains powered with rechargeable 10 year lithium cell back up Radio transceiver 868 499 MHz Unique Easi fit design with integral terminal block Simple and secure house coding system Interference free Wire in each Ei168RC RadioLINK base to the mains electricity supply RadioLINK SYSTEM CONTROL DEVICES Ei411H Wireless Remote Control Switch Wh
3. al alan ns g F pa y ili iF 900mm i MU oma Dead air space P do not install Do not install alarm alarm here within 300mm of any wall corner Siting alarm on a sloping ceiling Siting alarm in a room Siting alarms in hallways and landings Correct ceiling siting position for alarms Do not install alarms here For additional guidance please use the Customer Service Helpline 0870 758 4000 simple Interconnect Wiring for all Mains Powered smoke and Heat Alarms To mains To other power Neutral alarms supply S Le A in the system e g lighting as reguired Circuit or distribution board 140 160RC Series 140 160RC Series Interconnection of alarms is vital to ensure an activated alarm is heard throughout the property by all occupants Interconnecting Ei mains powered alarms has never been simpler using standard 3 core cable Innovative Design amp Quality Features Ei s unique large volume optical smoke smoke Alarms are sophisticated electronic devices chamber amp sophisticated electronics Protection from external contamination is vital to maintain have a proven track record of the fire detecting sensitivity of the product and to minimise reliability and high efficiency gt false alarms A fine mesh insect detection Longevity and resistance sg screen reduces false alarms caused to false alarms as well as reliable by insect contamination and fibres protection from electromagnetic whilst allowing free acce
4. circuitry built into the unit There s no need for extra bases or terminals All units use the standard Aico Easi fit baseplate and are compatible with existing 160 series alarms if no control device is to be introduced Wiring is equally simple With the control and interconnect signals being sent down the same cable the wiring for a typical RC alarm system is exactly the same as a standard interconnect mains alarm system This simplifies the wiring cuts installation time and removes the need for additional wires or cable types X THE NEW Eil 529RC CONTROL SWITCH The New 160 RC series This simple remote smoke alarm control switch offers four vital alarms can be used functions and can be positioned for convenient access similar to effectively in larger and a light switch Supplied with a suface box it can be flush mounted more complex applications using a standard 35mm deep electrical socket box including apartment blocks large houses HMOs TEST Test all alarms from one convenient switch and smaller commercial premises The alarms can HUSH Any nuisance alarm can be quickly and easily silenced be integrated with a number of additional gt LOCATE Allows the source of the alarm to be identified devices such as lighting i ial A be Di te See ot re am beacons sounders break MAINS The Test function will not operate without mains power PA ih INTRA Bila glass units and CO alarms CHECK providing a simple way to test the mains
5. the air within This causes a small current to flow in the chamber and this will remain constant for the life of the alarm unless smoke particles enter 2 When smoke enters the sensor chamber the balance of the current is disturbed 3 This is detected by the electronics in the alarm circuitry and a signal is sent to the Integrated Circuit IC 4 This causes the alarm sounder to operate How Ei Heat Alarms Work Integrated Circuit i oN Thermistor 2 Sensor Chamber Cover Heat Source 2 1 A thermistor a heat sensitive resistor is sited in the sensor chamber of the alarm 2 When the temperature rises the resistance of the thermistor reduces 3 The IC continuously monitors the resistance of the thermistor When this indicates the temperature is over 54 C the IC sends a signal to the sounder circuit 4 The alarm sounder then operates Average two storey house 7 Loft Conversion 4 Garage Living Room Kitchen K k Optical or onisatlon smol G Optical smoke alarm Smoke or heat PET as est st S ited MG Mlegt alarmi ij a da Bedroom Bathroom Hallway Max of 7 5m Max 3 metres from bedroom doors between each alarm Bedroom Living Room Bedroom ticular circumstances The control switch when used should be fitted at an easy access point preferably in the hall or living area k Do not install smoke orneat
6. Local Authority amp Housing Association Replacement Range COMPREHENSIVE 9 YEAR GUARANTEE surface Mount Kits amp Relays For 150 Series alarms see page 14 x UK and other countries Many of these alarms MAINS POWERED ALARMS WITH 10 YEAR RECHARGEABLE LITHIUM CELL BACK UP Advanced detection technology coupled with superior 10 year rechargeable lithium cell back up has made the 150 Series a market leader and the first choice for specifiers nationwide The 150 Series popularity and reliability over the last 15 years is proven by the fact that several million units have now been specified and installed by Councils and Housing Associations and are currently protecting households throughout the may now be entering the end of their useful life Cycle and should be considered for replacement New 150 Series product will fit the majority of existing installed bases and can therefore offer tne most economical replacement programmes el gt Code Description Ei 156TLH Optical with Hush ENlOITE lonisation with Hush EKSATIS Heat Alarm Surface Mount Kits for 150 Series alarms are also still available from stock Alarm Systems for the Deaf amp Hearing Impaired People with hearing difficulties require a different approach to fire protection as a conventional alarm sounder will not be sufficient for their needs Aico s range of alarms for the deaf and hearing impaired are the only units currently available fr
7. O 3 oO NEW 160RC Series Mains Powered Alarm opecifers F MAINS POWERED ALARM WITH 10 YEAR RECHARGEABLE LITIUM CELL The 160RC Series Egsi fit mains powered smoke and heat alarms are our highest specification range especially so when coupled to the RadioLINK system Designed for the specifier installer and end user demanding the very highest standards of safety performance and reliability you d expect from Europe s leading manufacturer of mains powered fire detection products Almost all practical duty of care provisions are catered for With no risk of casual back up cell removal the power supply is virtually guaranteed against any external threat to the energy supply Risks of false alarms are minimised and installation costs are lower due to ease of installation and the all round quality of the outstanding 160RC Series WHY RECHARGEABLE VANDIUM PENTOXIDE LITHIUM CEES The 10 year technology used in the 160RC Series provides the most effective and reliable back up power available Maintenance requirements are negligible The cells used are the only rechargeable cells with a realistic ten year life expectancy confirmed by manufacturer Panasonic Constantly Topped up by the mains they out perform lithium primary batteries capacitors or rechargeable cells Currently in use in other smoke alarms Environmentally friendly no special disposal requirements A precision charging circuit ensures peak efficiency at all t
8. aico Product Guide for smoke amp Heat Alarms Ahead on Quality Ahead on Performance di P aij io E m Mf j i d i 1 i 4 j F 1 u h TE j k f TI 4 i j j i i he I i F j Jo d A i gt U i 7 F F d dF Kk 7 y Fa OS a Fra Fj F 7 a i sm a j i j u hk s ma fi Fg i i al i d F F 5 3 gl a l a z s j j si rj i hs h 2 a d F i ao a i iil al a d E A Kk p Professional The Ei Range of Smoke Alarms from Aico offers the complete solution to meeting the new requirements of BS 5839 Pt 6 2004 for Residential Fire Detection Proven and reliable technology is combined with innovative product development to provide the best possible performance available in real fire situations Various options are offered in order that specifiers and end users can select the ideal product for every individual installation with regard to the building and its occupants All options offer value for money unprecedented ease for the installer and aesthetically pleasing designs Our new RadioLINK product is the ultimate solution as it provides for wireless interconnection of the alarms and achieves best practice installations in the easiest and most economical way The UK Market Leader As Europe s leading manufacturer of smoke alarms with over 30 years experience we currently outsell every comparable product on the market Qual
9. ations where the budget is a key consideration and where maintenance is 4 in the hands of ihe owner occupier or there is no requirement for lithium power cell back up The 140 Series provides an alkaline battery back up instead of rechargeable cells Further cost savings are possible through the innovative and totally unique Easi fit technology as there is no need to purchase additional wiring enclosures mounting kits leads or connectors In a field where time is money the fact that Easi fit alarms are simpler and quicker to install ensures even greater savings Now with Easi fit fixing pack suitable for use on plasterboard concrete or wood surfaces E1146 Optical With Hush e More responsive to slow smouldering fires Advanced optical chamber with proven extended life capability Fine mesh insect resistant screen Alkaline battery supplied already connected to reduce installation errors does not draw power until g Pt 2 200 i alarm is fitted to the mounting plate T E Eso m hi some ENSTVE Hush button for false alarm control gt N zast ir M Ok EAR Interconnects with other Ei mains powered Wis oan i m i a E M GUAR RANTEE smoke and heat alarms a DA fe i I separate mains and warning LEDs Time and money saving Egsi fit design Protective dust cover supplied 5 year guarantee i141 lonisation With Hush Responds quickly to fast flaming fires Unique and proven long life ionisation smoke chamber Alkaline battery s
10. current consumption Red or opal lens option For operation via an Fil58R or Ei128R relay 10 year rechargeable lithium cell back up designed to outlast the alarm Replacement sensor module minimum five year life Easy to use test nush button Automatic self diagnostics Distinctive alarm sound easily distinguishable from a smoke alarm Wall or ceiling mounting Pre alarm warning Interconnect feature Can be interconnected with Ei smoke and heat alarms Contact us for details Comprehensive Indicator lights Mains on Fault Alarm on Optional digital display Ei261DEN Quick CO gas test feature lt NOW WITH RC TECHNOLOGY OPTION YO3 Remote Sounder Mains powered Use in areas where a warning is required but a detector isn t For internal or external use Switchable sound outputs from 97 100dB A For operation via an Fil 58R or Ei128R relay MDH230 Magnetic Door Holder Mains powered Will automatically release a fire door in the event of a fire Test Override button feature Low current consumption For operation via an Ei158R or Ei128R relay Eil67 Remote Sounder Interconnects with all mains operated smoke and heat alarms Ideal for use where an alarm but no detection is required AC mains indicator light E ps AR BLE BDTBTUMICELDIS Further details of all the products o V Wf r featured on these pages are VA available from our Customer Service EASY IO 22
11. e up terminals Slide the alarm into The alarm is removed by plate supplied with the on the mounting place There s no releasing the tamper resistant alarm to the ceiling plate and clip on need to wire up a clip with a screwdriver and during first fix the protective separate lead and sliding it off The protective Cover No separate enclosure cover connector ensures that the mains cables is required are never exposed Multiple cable entries and surface wiring knockouts Large clearly marked wiring connections Heat alarms feature fixed temperature fast response thermistor sensor ideal for protecting kitchens amp garages Precision fin design allows fast access of smoke to the sensor Multi purpose fixings supplied for use in either plasterboard concrete or wood High performance corrosion resistant ionisation chamber responds quickly to flaming fires and is proven in millions of applications Exceptional reliability in a real fire situation Control option I60RC Series allow Test Hush and Fire Locate from an accessible switch position Product specifications SS Remote Control System Option lonisation Sensor Optical Sensor Heat Sensor Mains Supply Lithium Rechargeable Cell Back up Alkaline Battery Back up Lithium Battery Interconnectable 85dB A 3m Sound Output Easi fit System Test Hush Feature Test Hush and Fire Locate Feature Radio Frequency Interconnec
12. en used in conjunction with RC alarms with the Ei168RC RadioLINK base the switch offers three vital remote control functions TEST Provides a full system test equivalent to pressing the Test button on all units simultaneously HUSH Allows the silencing of LOCATE TEST NUSH any possible nuisance alarms SEEN eee IOU g alija 3 LOCATE Allows the source Of e mira ian the alarms to be identified This information is also held in the product memory 2 REMOTE CONTROL F E a ini OFF EIA28 Remote Relay Module Mains powered with rechargeable 10 year lithium cell back up to ensure the relay operates even during a mains failure e Interfaces with other systems e g warden call and other signal devices Ei407 Wireless Manual Call Point Allows manual testing of the system Allows manual alarm to warn other residents Ei410 Wireless Remote Control Hand Held e All the same features and functions as the Ei411H above but built into a small key fob for personal use e Fitted with lithium button cell Slide a 160RC Series House code alarm on to the each alarm in Ei168RC base which the system will automatically activate the rechargeable back up cells and then repeat this procedure for all the alarms in the system 140 Series Ihe Contractor s First Choice For New Build amp Owner Occupied Properties MAINS POWERED ALARMS WITH ALKALINE BATTERY BACK UP Designed for applic
13. i184 10 30VDC Heat Alarm E1186 10 30VDC Optical Smoke Alarm Ei 100R I2VDC lonisation Smoke Alarm Ei103R I2VDC Heat Alarm Ei1OSR I2VDC Optical Smoke Alarm For applications where the budget will not permit the installation of mains powered smoke alarms or there is a need to quickly provide safe and reliable protection to a large i number of properties the cy solution is to specify Ei smoke alarms powered by 10 year 4 battery cells Ura u if l dr dl Wi U i a Tiha Code Description Ei 1OOTYC lonisation Smoke Alarm Ei3105TYCH Optical Smoke Alarm surface Mount Kits enable easier installation of the alarms Relays Warden Call Systems Strobes provide the option of signalling to almost any other device Relays Sounders Door Closers can be used to signal to Smoke Vents Other Fire Alarm Systems Surface Mounting Kit for use on uneven ceilings or where complicated wiring is used As Ei127 with integral relay Not compatible with RC Models As Ei128R with 10yr rechargeable cell back up supply Cover to enable Fi128R Ei128RBU to be remotely sited Remote relay module for use with RadioLINK system only see page 11 Carbon Monoxide Devices CO Alarms ANCILLARY PRODUCTS NO ALARM NO CHANCE MCP401RC Manual Call Point amp Supplied complete with surface mount box Testing key supplied Supplied with non b
14. imes 6 month back up even without mains power Cells supplied fully charged providing 6 months initial standby capacity before mains powering Proven 10 year life expectancy Cells are soldered for reliable long term connection Terminals are laser welded for reliability Wide temperature range 20 C 10 60 C No battery replacement requirement EiIT66RC Optical With Hush More responsive to slow smouldering fires e Large volume high performance optical chamber with proven extended life capability Fine mesh insect resistant screen EIT61RC lonisation With Hush Responds quickly to fast flaming fires Unique and proven long life ionisation smoke chamber EI164RRC Heat With Hush e ideal for protecting kitchens and garages and other areas prone to false alarms Fixed temperature fast resoonse thermistor sensor range 54 62 C e BS 5446 Pt 2 2003 Class Al jes NOW ew 160 Series ko REMOT E CONT ROL functionality RADIOLINK COMPATIBLE FEATURES U EASI FIT DESIGN TECHNOLOGY HARDWIRED Without E11529RC HITAN tii f Cie WT Ae ead Eav Pal OVS ti i fie i Ree HARDWIRED a To vea IS With E1525RC Elite With 10 Year Rechargeable Lithium Cells irst Choice TESI HUSH AND FIRE LOCATE EROM AN ACCESSIBLE SWITCH POSITION New Aico RC Series smoke alarms are quick simple and economical to install with all the control
15. ity in our life saving products is never compromised We have a record of industry firsts including the first BSI Kitemarked range the first rechargeable back up power supply in a smoke alarm the first mains powered heat alarm the first with hush technology across the range and the only Easi fit design Ei now offer another first with the RadioLINK wireless interconnect system BS Gi G N QOY This is the definitive code of practice to which Architects Building Professionals Enforcing Authorities Landlords and Installers should refer for recommendations on the design installation and use of smoke and heat alarms in the majority of domestic dwellings Landlords in both the public and private sector are considered to have a duty of care to fit compliant smoke and heat alarms One to three storeys Grade D LD2 Mains alarms with battery back up Optical smoke alarms in circulation spaces hallways amp landings e g Ei146 or EI166RC with or without RadioLINK Heat alarm in the kitchen e g Ei144 or Eil64RC with or without RadioLINK Smoke alarm or heat alarm as best suited for the particular Circumstance see page 4 for definitions and usage in the main living room All alarms should be interconnected The sound pressure level of the alarm signal measured at the doorway of each bedroom with the door open should be at least 85dB A Two and three storey Grade D LD3 Mains alarms with battery back up Optical alarms in circula
16. neral optical alarms are recommended e g Ei146 Ei 66RC Heat alarm to be installed in the kitchen where there is no door separating the kitchen from the circulation space e g Fil44 Fil64RC amp Building extensions and room conversions above ground floor level require a Grade D LD2 system to be installed in the property amp Smoke and heat alarms should be interconnected Mains powered smoke and heat alarms may be interconnected using radio links r GD i _ T i iy U Wh M Ny a scotland Building Standards Technical Handbook No 2 Fire requiremenis are currently Grade D LD3 Mains smoke alarms with battery back up amp Smoke alarms are required in the circulation spaces hallways amp landings amp Smoke alarms should be interconnected Alarms may be interconnected using radio links Northern Ireland Building Regulations Northern Ireland Technical Booklet E Fire Safety requirements were amended in June 2005 to Grade D LD2 Mains Smoke alarms with a battery back up Smoke alarms are required in the circulation spaces hallways amp landings Na e A smoke alarm is required in the principe e g living room e O e e APPAOY JOCUMENT i par ri ae dii SECEDE tent ad ae bp asl fl murgui tral fee prati iwtruciur nai Brp eel i grd Pacililigra Pot Tie ation To The Importance of Type ALARM SENSOR TYPES Optical Alarms where should they be
17. ns powered alarms with no stand by power supply Battery powered alarms Three different categories of life protection systems are defined Briefly these are starting at the highest Alarms in all circulation soaces that form part of escape routes and all areas where a fire might start but not bathrooms shower rooms or toilets Alarms in all circulation spaces that form part of escape routes and rooms or areas that present a high fire risk Alarms in circulation spaces that form part of escape routes he Code emphasises that no one type of alarm is most suitable for all applications Consideration must be given to the most suitable type of defection optical ionisation and heat see page 4 for definitions Residential Fire Detection amp Regulations how do they affect me What do Building Regulations Demand in New Build and Materially Altered Dwellings Architects builders and installers must comply with Building Regulations and install mains powered smoke alarms in new and materially altered dwellings England amp Wales Building Regulations Approved Document B Fire Safety minimum requirements are currently Grade D LD3 but also defines that installation should be to BS 5839 Pt 6 and therefore Grade D LD2 is recommended Grade D LD2 Mains alarms with battery back up wired to a lighting circuit or a dedicated circuit Smoke alarms are required in the circulation spaces such as hallways and landings In ge
18. om an experienced smoke alarm manufacturer They are also available with RadioLINK for ease of installation system Features and Benefits of all models Mains powered control panel with rechargeable battery back up High intensity integral strobe light Auxiliary socket for connection of additional optional s trobe lights Vibrating pad for placing under a pillow or mattress Supplied with plug in or hard wired option Capability for interconnection of up to 12 alarms Test button on control panel for testing the system Connections are monitored to check integrity of system Alarm clock input facility Remote trigger option Pager output facility Compatible with RadioLINK system Eil69RE Eil Z6RP e systems available for mains or LV operated smoke alarms AN RadioLINK Code Description Ei169 Mains Deaf Alarm Kit for 150 Series Ei169 160 Mains Deaf Alarm kit for 160RC Series Ei169RF RadioLINK Mains Deaf Alarm Kit for 160RC Series EI 79 Complete with LV lonisation Smoke Alarm Bill ie Complete with LV Optical Smoke Alarm Ei Z6RF RadioLINK LV Optical Smoke Alarm Kit Ei178 Additional Strobe Ei174 Additional Vibration Pad Ei3 1O5RF Additional RadioLINK LV Optical Smoke alarm In properties where there is a requirement to connect smoke and heat alarms to a low voltage security system or Warden Call System the Ei180 Series alarms can provide the ideal solution Code Description Ei181 10 30VDC lonisation Smoke Alarm E
19. reakable operating element LPC approved conforms to BS EN 54 11 Can be used with 140 150 160RC Models Carbon Monoxide or CO is a particularly insidious gas It is a killer The naked eye can t see it it does not smell it has no taste The need for a reliable mains powered alarm that will operate even in the event of a mains failure is obvious The Ei professional range includes fully featured product usually specified by Local Authorities amp Landlords and less sophisticated product where duty of care is not so much of an issue and where the mains supply is more likely to be continuous and or regular battery maintenance is known to be reliably carried out SAB300 Remote Strobe Xenon Beacon Mains powered e For internal or external use Flash energy of 3 watts and flash frequency of 9Hz e Clear or red lens options e For operation via an EI158R or Eil28R relay The Ei261EN is the top of the range product Current sensor technology used by all manufacturers of CO alarms has a limited life cycle the sensors cannot be relied upon after a period of 5 6 years The Ei261EN offers a replacement sensor feature thereby increasing the life cycle of the product to ten years EI2Z61EN Mains Powered CO Alarm with Rechargeable Lithium Cells and Replaceable CO Sensor SABV4 High Intensity Strobe Xenon Beacon Mains powered Ideal for use where standard strobes may not be sufficiently visible 5 joule high intensity flash Low
20. rms Work Integrated Circuit Zi Pulsed Infra Red B Light Receptor Insect Screen Light Proof Chamber 1 A light beam is pulsed in the sensor chamber every 10 seconds to look for smoke Any smoke present has to be visible to the naked eye so that the receptor can see it If no smoke is detected the alarm will remain in a standby state 2 When large particle smoke is detected the light beam will be scattered onto the light receptor 3 This will then send an electrical signal to the IC Integrated Circuit 4 f two consecutive signals are received by the IC the alarm will sound Heat Alarms where should they be used Heat alarms are less likely to cause false alarm problems as they are not responsive to any type of smoke or fumes only heat Because of the potential for a slower response than smoke alarms they should only be used in a fire alarm system that also includes smoke alarms and all of the alarms must be interconnected The BS 5839 Pt 6 2004 recommends that heat alarms should be used in kitchens It goes on to suggest that they may also have a role to play in the main living room but they should not be installed in circulation spaces or areas where fast response to fire is required How Ei lonisation Smoke Alarms Work Integrated Circuit Ei Ox Electrodes E Radioactive Source 2 etana Cover 1 Inside the sensor chamber is a minute safe radioactive element that ionises
21. ss of smoke interference has also been proven over to the sensor chamber A dust cover is the last 15 years also provided for protection on site and prior fo occupancy At 85dB A at 3 metres our alarms are loud Unique encased horn assembly has the piezo disc securely held with silicone mastic to The hush button prevent creepage and premature horn failure provides for false alarm Additionally soldered contacts prevent failures control on all Easi fit due to corrosion and arcing associated with models Also provides more commonly used pressure contacts manual test function om Self monitoring and indicating LEDs amp audible warning signals Each alarm self tests every 40 seconds Iwo separate LED indicators are used to indicate healthy mains supply fault battery fault alarm status and low cell pattery warning Ultra high performance vanadium pentoxide lithium rechargeable cells are used on the 160RC Series 150 Series and RadioLINK bases These cells offer the best back up possible and are designed to outlast the alarms e A precision charging circuit ensures peak cell efficiency at all times M e Cells provide up to six months back up even without mains power e Alkaline battery in the 140 Series designed to last up to 4 years in standby THE FASTEST SIMPLEST INSTALLATION POSSIBLE Fitting an Easi fit mains powered alarm really is this simple eds REMOVAL Screw the mounting Wir
22. supply aka as part of a comprehensive alarm system mE MANUAL CALL POINT MCP401RC Manual Call Point Surface Mount for use with all Ei mains alarms PadioLINK Wireless For use with T60RC Ser THE COMPLETE SOLUTION TO THE NEW BS 5839 Pt 6 2004 REQUIREMENTS Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire Fire statistics show that the quicker occupants are alerted to a fire the less risk of death or injury there is Furthermore property damage is also reduced With RadioLINK mains powered smoke alarms are interconnected by wireless signals rather than cabling It s so much simpler more convenient and easier to change or extend as and when required The new Fi168RC RadioLINK base is now set as a multi level repeater as standard This means it can now receive transmit and re iransmit to achieve multiple signal paths The result Increased coverage in houses of a larger floor area and with up To 30 alarms in the system The multiple path capability allows the system to manage many RF impenetrable structures in the property which may have previously blocked signals House coding and commissioning has been simplified and is now a faster operation i It s an upgrade which makes RadioLINK even better suited to more comprehensive alarm systems offering greater coverage and protection The Benefits of RadioLINK e Best Practice for single family dwellings
23. t High Performance lonisation Chamber Large Volume Optical Chamber Insect Screen on Optical Chamber 54 62 C Thermistor Temperature Range Fast Access Smoke Finning LED Power Indicator LED Auto Circuit Test Indicator LED Hush Mode Indicator LED Alarm State Indicator LED Transmission Reception Indicator LED House Coding Indicator Audible Fault Warning Audible Low Battery Warning Automatic Hush Mode Reset Connection with Battery Missing Prevented Non Reversible Mains Connector Lead Unit Activation Upon Connection Tamper proof Rechargeable Cells Soldered Horn Contacts Easi see Easi connect Wiring Terminals Mains Wiring Cable Cover Multiple Cable Entries Removable Mini Trunking Entry Foam Sealing Gasket Anti tamper Locking Catch Multiple Fixing Holes Date Code Identification BS Kitemarked CE Marked EMC Conformance BS amp Building Reg Grade D Compliance BS amp Building Reg Grade E Compliance Class II Double Insulated UV Stabilised Moulding Installer Instructions User Instructions Combined Installer User Instructions Dust Cover Supplied Distribution Board Label Supplied Multi Purpose Fixings Included Typical Footprint Dimensions mm N KOJ D U O S Modifire RF Modifire Hard wired System Control Devices System Control RadioLINK Base 160RC Series 150 Series KIS Ns Nu 5 S i p u S S S i N ar u o ASST SEES ES Sst ST st sty S Bi a oO 3 o
24. tion spaces hallways amp landings e g Ei146 or Ei1166RC with or without RadioLINK If a fire risk assessment shows the property or occupier to be a high fire risk increase the number of alarms gt installed to meet the risk e g follow new build F recommendations for an LD2 installation F a All alarms should be interconnected i The sound pressure level of the alarm signal measured at the doorway of each bedroom with the door open should be at least 85dB A Single storey Grade F LD3 Battery powered with a minimum battery life of 5 years e g Ei 10 year alarm Optical smoke alarm in circulation spaces hallway e g ris JOSTYCH If a fire risk assessment identifies a concern that the occupier cannot or may not replace a battery use mains alarms or mains with battery back up If a fire risk assessment shows the property or occupier to be a high fire risk increase the number of alarms installed to meet the risk e g follow new build recommendations for an LD2 installation Six different grades of fire detection systems are defined and generally speaking the greater the fire risk the more comprehensive the system should be Briefly the Grades are as follows A full system with control and indicating equipment installed to BS 5839 Part Detectors and sounders using simpler specified equipment Detectors and sounders or alarms with central control Mains powered alarms with an integral stand by power supply Mai
25. upplied already connected to reduce installation errors does not draw power until alarm is fitted to the mounting plate Hush button for false alarm control Interconnects with other Ei mains powered smoke and heat alarms aii separate mains and warning LEDs Time and money saving Easi fit design RADIOLINK Protective dust cover supplied oc SOMPATIBLE 5 year guarantee WIIH E1168 HO Compatible WifhETGBRG EI144 Heat With Hush Ideal for protecting kitchens and garages and other areas subject to false alarms e Fixed temperature fast response thermistor sensor range 54 62 C wa e Alkaline battery supplied already connected to reduce s installation errors does not draw power until alarm is fitted to the mounting plate 980090000 082007 0600006 880 Surface Mount Kits amp Relays For 140 Series alarms see page 14 amp Hush button for false alarm control amp Interconnects with other Ei mains powered smoke and heat alarms e Separate mains and warning LEDs e ime and money saving Easi fit design Code Description Protective dust cover supplied Ei146 Optical with Hush amp Mounting Plate e 5 year guarantee Ei141 lonisation with Hush amp Mounting Plate BS 5446 Pt 2 2003 Class Al O O Ei144 Heat Alarm with Hush amp Mounting Plate E27 Surface Mount Kit SO SI LJ I Ei128R Surface Mount Kit with 5 amp Relay Ei128RBU Surface Mount Kit with 5 amp Relay and 10Yr Rechargeable Lithium Cells meee ee o 150 Series
26. used Optical sensors are more responsive to smouldering fires producing large particle smoke typical of fires involving furniture and bedding They are more immune to invisible smoke produced by burning the toast and similar cooking fumes This makes them ideal for siting in hallways close to kitchens where false alarms from ionisation alarms may be a particular problem The BS 5839 Pt 6 2004 Standard recommends the use of optical alarms in circulation spaces of a dwelling such as hallways and landings Optical alarms are prone to false alarm if exposed to steam and should not be located too close to poorly ventilated bathrooms or shower rooms amp Interconnection of lonisation Alarms where should they be used lonisation type sensors are particularly sensitive to the almost invisible smoke produced by fast flaming fires This makes them more liable to false alarm due to cooking fumes if sited in a hallway close to a kitchen lonisation alarms are less vulnerable to false alarms caused by dense Tobacco smoke excessive dust and insect ingress The BS 5839 Pt 6 2004 Standard recommends that ionisation alarms should not be used in hallways and landings where there is a risk of false alarms caused by cooking fumes Note Either type of sensor is generally suitable The choice of sensor type should if possible take into account the type of fire that might be expected and the need to avoid false alarms How Ei Optical Smoke Ala
Download Pdf Manuals
Related Search
Related Contents
IP48Win Service Manual Manual del propietario del panel de control Valley Pro2 Canon Office All-In-One All in One Printer User Manual USER MANUAL FOR MINT NB - HCL Customer Support Division User`s Manual Gebruiksaanwijzing Manuel d`utilisation NL GUV-I 8553 - Freie Universität Berlin CL1Y2-TE1D2S CC-Link/LT Remote I/O Module User`s Manual Récepteur Stéréo HK 3370 Neff U14M62 Copyright © All rights reserved.