Home

Admiral AW-05CR1FHLU User's Manual

image

Contents

1. ATH L e Fig 2 Abertura minima de Ventana 5 3 Es Abertura m xima tomacorriente el ctrico adecuado Utilice un de Ventas E Aseg rese de instalar la unidad cerca de un tomacorriente de 15 amperios con circuito exclusivo Minuta Altura para el aire acondicionado Todos los cables deber n de Ventana cumplir con los c digos el ctricos locales y nacionales O Instrucciones de Instalaci n Pasos para la instalaci n en ventanas 1 Si el aire acondicionado tiene un gabinete de 17 7 de ancho podr colocarse en aberturas de ventanas de 21 a 35 de ancho La altura m nima de abertura es de 14 desde la parte inferior del marco hasta el umbral Fig 1 2 Une el sello del canal al fondo del canal e instala el canal superior al aire acondicionado con los tornillos e inserta las gu as del bastidor de la cortina hasta las gu as de la unidad y despu s sujeta las cortinas a la unidad con los tornillos Vea Fig 2 3 Corte la tira de sello adhesivo del ancho de la ventana Quite el revestimiento de la tira adhesiva y p guela en el interior de la parte inferior de la ventana Fig 3 4 Mida el ancho del interior del umbral de la ventana y defina la linea central tal como se indica en la Fig 4 O Instrucciones de Instalaci n Umbral Externo ji Tornillo de 3 4 Umbral interno 5 Instale los soportes en L en el umbral externo de e el modo que la parte m s corta del soporte apoye contra
2. CAUTION dh DO NOT forget to install the air filter If the air conditioner is left to operate without the air filter dust is not removed from the room and may cause your air conditioner to fail When the air filter air inlet grille and cabinet are dirty wipe with lukewarm water below 40 C Use of mild detergent is recommended Cleanina of Air Fil 1 Remove dust clogged in the filter by tapping it or vacuum clean it 2 Wash the filter well with lukewarm water below 40 C 104 while rubbing lightly To get better results wash it with soapy water or a neutral cleaning agent 3 Rinse the filter well using clean water then dry completely End of Season Care 1 Operate the fan alone for half a day to dry out the inside of the unit 2 Turn off power and remove plug from wall socket 3 Clean filter 4 Store in a dry location Troubleshooting Guide Frequently a problem is minor and a service call may not be necessary use this troubleshooting guide for a possible solution PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will No power to the unit Check connection of power cord to not operate power source Check fuse or circuit breaker Turn the power switch to ON Inefficient or no cooling Dirty air filter Clean or replace air filter Inappropriate capacity Check with dealer to determine proper unit for application capacity for application Blocked air flow Remove ob
3. lt lt Tomillo de 3 4 la parte posterior del umbral interno Instale un soporte en La 7 5 de cada lado de la linea central Vea la Fig 5 del Soporte 6 Levante el aire acondicionado con mucho cuidado y desli celo por la ventana abierta Aseg rese de que la gu a inferior del aire acondicionado se inserte en las ranuras de los soportes en L Cuando el aire acondicionado apoye en los soportes en L quedar centrado en la abertura de la ventana tal como se indica en la Fig 6 Mientras acomoda el aire acondicionado baje el marco de la ventana con mucho cuidado y ap yelo en el canal superior del aire acondicionado tal como se indica en la Fig 7 Primero ajuste ambos lados al umbral de la ventana con dos tornillos de 3 4 y uno de 2 5 que se destornilla de cada lado de la unidad Luego ajuste el canal superior al marco de la ventana con un tornillo de 3 4 y ajuste los marcos de la cortina lateral con cuatro tornillos de 3 4 tal como se indica en la Fig 6 7 Si una ventana resistente a huracanes interfiere adhiera una tabla de madera de 2 de ancho al umbral interno de la ventana a lo largo de todo el ancho del umbral La tabla de madera deber ser lo suficientemente gruesa como para elevar la altura del umbral de la ventana de modo que la unidad pueda instalarse sin que el marco de la ventana resistente a huracanes interfiera tal como se indica en la Fig 8 Para que sea til la parte superior de la tabla d
4. your air conditioner will give you many years of trouble free operation To avoid installation difficulties read instructions completely before starting This manual contains information for the installation and operation of your room air conditioner Part Identification gt for mechanical control model Thermostat Knob Vertical Air Vane Cabinet FanSpeed Switch Interior t Outlet Power Switch Air Filter Front Panel Air Inlet f A Power Cord Interior Air Inlet Grille Note The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Introduction And Parts Identification y Thank you for choosing this room air conditioner to cool your home This Use and Care Manual provides information necessary for the proper care and maintenance of your new room air conditioner If properly maintained your air conditioner will give you many years of trouble free operation To avoid installation difficulties read instructions completely before starting This manual contains information for the installation and operation of your room air conditioner Parts Identification AA A AAA A gt Remote control model Control Panel Vertical Air Vane cal Interior Air Outlet gt Air Filter Front Panel N Air Inlet Interior Air Inlet Grille Note The figures in this manual are based on the external
5. ES AIR CONDITIONER SAFETY e The portable air conditioner should be connected to a 115 V 60 Hz 15 or 20 amp fused 3 prong grounded outlet e The use of a time delay fuse or time delay circuit breaker is recommended e All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions contact a qualified electrician Electrical Requirements A WARNING y ELECTRIC SHOCK HAZARD Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Power Supply Cord NOTE Your unit s device may differ from the one shown A Reset Button B Test Button This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage currant If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button will trip and pop out 4 Press and release RESET listen for click Reset button will latch and remain in The power supply cord is ready for operation NOTES The Reset button must be pushed in for proper operation T
6. En consecuencia es probable que la forma sea diferente a la del aire acondicionado que usted seleccion Modelo de Remoto controlador Rejilla de Entrada de Aire Interior Aleta de Aire Vertical Tirador Controlado Filtro de Aire Gabinete Entrada de Aire Exterior Control Remoto Rejilla de Ventilacion de Aire Interior Cable de Alimentaci n Nota Las im genes de este manual est n basadas en la vista externa de un modelo est ndar En consecuencia es probable que la forma sea diferente ala del aire acondicionado que usted seleccion Especificaciones el ctricas 1 Todos los cables deben cumplir con los c digos el ctricos locales y nacionales y los debe instalar Peligro de Descarga El ctrica un electricista licenciado Si tiene preguntas Si el r tulo del aire acondicionado indica 115 relacionadas con las siguientes instrucciones voltios y hasta 7 5 amperios la unidad se comun quese con un electricista licenciado puede conectar a un cortacircuito o fusible utilizado por otros dispositivos No obstante i _ la suma de los amperios m ximos de todos 2 Verifique el suministro de energ a disponible y los dispositivos conectados a dicho resuelva cualquier problema con los cables ANTES cortacircuito o fusible no deben exceder los de instalar y hacer funcionar esta unidad amperios del mismo Si el r tulo del aire acondicionado indica 115 voltios y m s de 7 5 amperios debe tener su 3 Para
7. FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER e This warranty is to the original owner for products purchased for home use within the USA Some state do not allow the exclusive or limitation of incidental damages This warranty gives you specific rights and you may also have other rights which may vary from state to state To know what your legal rights are consult your local or state consumers affairs office or your state s Attorney General m wW Introducci n Gracias por elegir este aire acondicionado para enfriar su hogar Este MANUAL DE USO Y MANTENIMIENTO proporciona la informaci n necesaria para cuidar y mantener en forma adecuada su nuevo aire acondicionado Funcionar sin problemas durante muchos a os si le brinda el mantenimiento apropiado Para evitar problemas al instalarlo lea completamente las instrucciones antes de comenzar Este manual contiene informaci n acerca de la instalaci n y el funcionamiento del aire acondicionado para habitaciones gt Identificaci n de las Piezas gt Modelo Mec nico Aleta de Aire Vertical Rejilla de Ventilaci n Gabinete de Aire Interior Termostato Controlado Interruptor de FanSpeed Interruptor de Energra Filtro de Aire en el interior Entrada de Panel Frontal Aire Exterior Rejilla de Ventilacion de Aire Interior Cable de Alimentaci n Nota Las im genes de este manual est n basadas en la vista externa de un modelo est ndar
8. antes de cambiar la temperatura Si la cambia FANSPEED s n demasiado r pido es posible que cause una sobrecarga y BAJO Circular el aire en una velocidad se queme el fusible m nima con refrescarse o no recomendada para el uso de la noche HIGH FAN Ventilador al M ximo har que el aire circule a una velocidad m xima sin enfriar NOTA Despu s de seleccionar un nivel espere 3 minutos antes de pasar a otro Instrucciones de Instalaci n ON Este aire acondicionado se puede operar f cilmente con los botones del panel de control asicomo tambi n con el control remoto OFF Bot n Encendido Apagado Si presiona este bot n encenderiel aire acondicionado Cuando el aire acondicionado esta de calefacci n se per imprentar este bot n 3 minutos despu s BOTON MODE MODE Cada vez que se presiona el bot n MODE el modo de operaci n cambia en estas secuencias COOLING Enfriamiento FAN ONLY S lo ventilador ENERGY SAVING Ahorro de Energia COOLING Enfriamiento NOTA Despu s de seleccionar un nivel espere 3 minutos antes de pasara otro Con el modo de FAN ONLY El recinto de la temperatura Dehabitaci n ser Desde 0 C 32 F hasta 38 C 99 F La temperatura de la habitaci n es superior a32 F la temperatura lucer LO La temperatura de la habitaci n es superior a 99 F la temperatura lucer H1 BOTON FAN SPEED Velocidad del Ventilador Se utiliza para seleccionar la velocidad del v
9. the appropriate setting The thermostat will automatically controls the cooling cycle of the air conditioner to maintain room temperature However the fan motor will continue to operate after the compressor is completed See Fig 9 Fan Speed LOW will circulate the air at a minimum speed with cooling or not Recommended for night time use HI will circulate the air at a maximum speed with cooling or not NOTE After setting the mode allow 3 minutes before switching to another mode Thermostat knob Woit Three Minutes Before Restarting y switch Fig 9 A CAUTION A When using FAN control turn slowly allowing unit to adjust When using THERMOSTAT be sure to allow 3 minutes before changing temperature Adjusting too quickly may cause an overload resulting in a blown fuse Operating Instructions gt Control Panel You can easily operate this air conditioner by press relevant button on the control panel as well as the remote control ON OFF The air conditioner will be started when it is energized or will be stopped when it is in operation if you press this button MODE Each time Mode button is pressed the operation mode is changed in sequence COOLING FAN ONLY gt ENERGY SAVING COOLING NOTE After setting the mode allow 3 minutes before switching to another mode In the FAN ONLY Mode Room Temperature display range is from 0 C 32T to 38 99T Room Temperature below 0 C the Temperatu
10. view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Electrical Specifications 1 All wiring must comply with local and national electrical codes and must be installed by a qualified electrician If you have any questions regarding the following instructions contact a qualified electrician 2 Check available power supply and resolve any wiring problems BEFORE installing and operating this unit 3 For your safety and protection This unit is grounded through the power cord when plugged into a matching wall outlet f you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 4 The wall outlet must match the plug on the service cord supplied with the unit DO NOT use plug adapters or extension cord 5 The rating plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit y Electric Shock Hazard If the air conditioner has a serial plate rating up to and including 7 5 amps the unit maybe on a fuse or circuit breaker with other devices However the maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse of circuit breaker If the air conditioner has a serial plate rating greater than 7 5 amps it must have its own fuse or circuit breaker and no other device or unit should be operated on the fuse or circuit br
11. 5 opening Min Window 14 height Installation Instructions Window installation step 1 If your air conditioner cabinet 17 7 wide it will fit window openings 21 to 35 in wide Minimum opening height is 14 from bottom of sash to sill See Fig 1 2 Attach the channel seal to the channel bottom and install the top channel to the air conditioner with screws and insert the guides of the curtain frame into the guides of the unit then fasten the curtains to the unit with screws See Fig 2 If the guide of the curtain frame presents interference with the base pan cut the guide to proper length 3 Cut the adhesive backed seal strip the window width Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window See Fig 3 4 Measure the inside window sill width and find the center line as shown in Fig 4 Installation Instructions 5 Install the L brackets on the outer sill with the short side of the bracket against the back of the inner sill Install one L bracket 7 5 to each side of center line See Fig 5 Inner Sill 4 Screw Center Line 6 Carefully lift the air conditioner and slide it into the open window Make sure the bottom guide 5 of the unit drops into the notches of the L brackets When the air conditioner drops into the L brackets y the air conditioner will be centered in window opening Sq as show
12. ANT AS EXPRESADAS O IMPLICADAS DURAN POR 3 A OS A PARTIR DE LA FECHA DE LA COMPRA ORIGINAL ESTA GARANT A NO CUBRE LA RESPONSABILIDAD POR LOS DA OS FORTUITOS O CONSECUENTES PARA CUALQUIER CAUSA O Esta garant a est al due o original para los productos comprados para el uso casero dentro de USA e Un cierto estado no permite la exclusiva o la limitaci n de da os fortuitos Esta garant a le da los derechos espec ficas y usted puede tambi n tener otros derechos que puedan variar de estado al estado Para saber cu les son consultan sus derechos legales a su oficina de los consumidores de los asuntos o general local o del estado del abogado de su estado O Admiral 2006 Admiral Kelon Air Conditioner Co Ltd and Kelon USA Inc All rights reserved Kelon Air Conditioner Co Ltd Kelon USA Inc No 12 Qiaodong Road 17005 Evergreen Place Blag A Ronggui Shunde Guangdong China 528303 City of Industry CA 91745 Printed in China Version No 819043291 01
13. Admiral ROOM AIR CONDITIONER Use and Care Manual AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento Y Remote control AW 05CR1FHLU y 4 l i Mechanical control AW 05CM1FLU Thank you for purchasing an Admiral room air conditioner Please read this Use and Care Manual carefully before installing and using this appliance Keep this manual for future reference Muchase gracias por comprar un aire acondicionado Admiral Lea atentamente el Manual de Uso y Mantenimiento antes de instalar y utilizar este producto Conserve este manual para consultario en el futuro For Service Call 1 877 465 3566 Para obtener servicio t cnico llame al 1877 465 3566 TABLE OF CONTENTS Page E a ei 2 3 Introduction and Parts Identification 4 5 ENMGCHIGE SOBUITICOATODS src AAA AA 6 MICRA IMM ercer a RNA AAA 7 IA rra 8 10 Operate IICA pizarra ieee See AA 11 14 A ASAS cee 15 MAN oc A Rd iaghated 16 MERO ELIANA AA ee 17 INDICE Page MOGUCEM secous CREAS AAA 18 IIONUTICACION de PPAR oia cra 18 19 Especificaciones A Nrern een 20 Consejos Antes COI inStniggign izar 21 INSUUECIONOS DO MODOD rr rra 22 24 RICE OC DAMA arras quaint 25 28 A A AAA a eee ae Pee ea 29 Gula Dara la SOCION GS PIODIGWIAS AR 30 AS wane eee 31 AIR CONDITIONER SAFETY What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this man
14. E This unit is NOT designed for vertical slider type windows To avoid installation operating difficulties _ read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of hardware kit against the corresponding model check list prior to installation of the unit See lists below Installation Hardware 3 4 Screws 7 Seal 1 me 2 5 Screws 11 Foam 1 gt Top Channel 1 Side Curtain RH 1 Channel Seal 1 Side Curtain LH 1 lt gt L Bracket 2 NOTE Surplus screw s for spare use Tools Needed for Window Installation Screw drivers Both Philips and flat head Power drill 1 8 inch diameter drill bit Pencil Measuring tape Scissors Cutter Carpenters level Installation Instructions A CAUTION dh Because the compressor is located on the controls side of the unit this side will be heavier and more awkward to manipulate Inadequate support on control side of the unit can result in personal injury and damage to your unit and property Therefore itis recommended to have someone assist you during the installation of this unit Select the Best Location A Your room air conditioner was designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure wi
15. a ambiente en modo COOLING o para programar la hora en modo TIMER Pero la marca del T odel F que no puedes cambiar Generalmente esos modelos se utilizan con 220v 50Hz marcado con C otros modelos se marcan con F NOTA el rango de temperaturas oscila entre 19 y 66 9F y 31 C 88 F Instrucciones de Operaci n gt Control remoto pe Power el Mode Timer Power Savar i o DB gt Temp Time Bot n Power Encendido Apagado El aparato se encender si ests apagado o apagar cuando est en operaci n si oprime este bot n a Bot n Mode Modo Utilice este bot n para seleccionar el modo de operaci n Bot n Botones de ajuste de temperatura oprima para ajustarla temepratura del cuarto oprima para programar la hora Bot n High Para ajustar el modo alta velocidad de ventilador Bot n Mid Para ajustar el modo mediana al mismo baja velocidad de ventilador Bot n Low Para ajustar el modo baja velocidad de ventilador Bot n Auto Para ajustar el modo auto velocidad de ventilador Bot n Timer Temporizador Para ponero cancelarla operaci n de timer Bot n Power Saver Para ajustar el modo de energia ahorro EA Despu s de seleccionar un nivel espere 3 minutos antes de pasar a otro Espere 3 minutos antes de recomenzar el aparato Instrucciones de Operaci n gt Control remoto e Colocai n de las p
16. a unidad Olores Formaci n de moho u hongos Quite el tap n de drenaje y la bandeja sobre las superficies base h medas Cambie el tap n de drenaje Limpie la unidad en forma completa Es normal la descarga de Gotea agua afuera condensaci n cuando el Utilice tuberias flexibles para desviar el clima es lido y h medo flujo de agua La unidad debe instalarse con un ligero Gotea agua adentro La unidad no est bien inclina desnivel para permitir una descarga da como para permitir el adecuada de la condensaci n Verifique desague externo la unidad y realice los ajustes necesarios k Cuando la temperatura exterior sea inferior a Se forma hielo o Baja temperatura exterior los 65 F es posible que se forme escarcha si escarcha la unidad funciona en modo de enfriamiento Cambie el funcionamiento de la unidad a FAN solamente hasta que la escarcha se derrita El filtro de aire de la unidad Quite el filtro y li mpielo est sucio NOTA Si el cortacircuito interrumpe la corriente varias veces o el fusible se quema m s de una vez comun quese con un t cnico licenciado O GARANTIA 1 Garantia completa de un a o Por un a o a partir de la fecha en de compra del due o original cualquier parte que falle materiales o ejecuci n bajo el uso normal de la unidad ser substituida Durante este per odo todas las piezas y servicio ser n proporcionados gratuitamente siempre y cuando el acondicionador
17. ber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad de aire exterior o interior C mo Quitar el Filtro de Aire El filtro de aire de los modelos anteriormente mencionados se encuentra detr s de la rejilla de entrada de aire delantera Para quitarlo tome el mango del filtro lengueta ubicado en la parte superior centro de la rejilla de entrada de aire y deslicelo hacia arriba Para volver a instalarlo realice los procedimientos anteriores a la inversa NO olvide instalar el filtro de aire Si el alre acondicionado funciona sin el filtro de aire el polvo no se puede eliminar de la habitaci n y es posible que la unidad se descomponga CAUTION NO olvide instalar el filtro de aire Si el aire acondicionado funciona sin el filtro de aire el polvo no se puede eliminar de la habitaci n y es posible que la unidad se descomponga Cuando la rejilla de entrada de aire y el gabinete est n sucios li mpielos con agua templada por debaj de los 104 F Se recomienda el uso de un detergente suave Limpieza del Filtro de Aire 1 Elimine el polvo acumulado en el filtro Para ello apli quele unos golpes suaves o una aspiradora dom stica 2 Lave bien el filtro con agua templada de temperatura inferior a los 40 C 104 F mientras lo frota suavemente Para obtener mejores resultados l velo con agua jabonosa o con un producto de limpieza neutro 3 Enjuague b
18. de aire ha estado instalado y funcionado de acuerdo con las instrucciones escritas en este manual Incluye de la garant a en el servicio casero 2 Limitada segunda a garant a de tercer a o Para el segundo con el tercer a o a partir de la fecha de la compra original esta garant a proporcionar un compresor del reemplazo gratuitamente debido a producir una falta El cliente va a ser responsable para el cargo relatado del labuor de cambiar el compresor de dos a tres a os El consumidor es responsable de los gastos del trabajo y de posible gasto de servicio para embarcar las unidades El gasto para mover el acondicionador de aire a los servisiadores hace compras y de nuevo a los usuarios a casa como puede ser requerido y es la responsabilidad de los usuarios 3 Qu no se cubre O Esta garant a no aplica da o si ocurrido debido a accidente la direcci n o la operaci n incorrecta el da o de env o el abuso el uso err neo desautorizados reparada o procurada o el uso comercial del producto o ning n otro uso para el cual no fuera pensado O Esta garant a no aplica da o al producto causado por accidente fuego y las inundaciones o los actos de la guerra del terrorismo o del acto de dios O Esta garant a no cubre viajes del servicio a su hogar para educarle en el uso del producto p rdida de alimento y bebida debido a los desperdicios que esta garant a no se aplica fuera del continente los Estados Unidos TODAS LAS GAR
19. e air conditioner has been installed and operated in accordance with the written instructions in this manual This warranty includes in home service 2 Limited second through third year warranty For the second through the third year from date of original purchase this warranty will provide a replacement compressor free of charge due to product failure The customer will be responsible for the labor charges related to replacing the compressor in years two through three The consumer is responsible for the service labor and possible freight charges for shipping the unit Cost to move the air conditioner to the servicers shop and back to the user s home may be required and are the user s responsibility 3 What is not covered e This warranty does not apply if damage occurs because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted commercial use of the product or any other use for which it was not intended e This warranty does not apply to damage to the product caused by accident fire floods acts of war terrorism or acts of God This warranty does not cover service trips to your home to educate you on the use of the product or loss of food and drink due to spoilage e This warranty does not apply outside the continental United States e ALL WARRANTIES EXPRESSED OR IMPLIED LAST FOR 3 YEARS FROM THE DATE OF ORIGINAL PURCHASE THIS WARRANTY DOES NOT COVER LIABILITY
20. e madera deber estar aproximadamente 3 4 m s arriba que el marco de la ventana resistente a huracanes para sumidero Instale una segunda tabla de madera de aproximadamente Espacio de 3 4 6 de largo por 1 1 2 de ancho y el mismo grosor de la primera tabla en el centro del umbral externo contra la parte posterior del umbral interno Atornille los soportes en L a esta tabla Esto elevar el soporte en L tal como se indica en la Fig 8 Fig 7 Fig 8 24 Instrucciones de Instalaci n Control de MODE Modo Termostato ON Va a empezar el aire acondiciondo OFF Apagado apaga la unidad completamente VENTILADOR SOLO Rota el dial de la perilla a la marca del ventilador solo la unidad circular el aire sin refrescarse Vea Fig 9 REFRIGERADOR Rota el dial de la perilla a las marcas del refrigerador la unidad circular el aire Before Heaterting con refrescarse Para fijar la temperatura refresca que desea rota simplemente la perilla al ajuste apropiado El termostato Interruptor Fig 9 controlar autom ticamente el ciclo refresco del aire acondicionado para mantener la temperatura ambiente Sin embargo el motor del ventilador A PRECAUCI N A continuar a si io despu s de que Cuando utilice la perilla de control de ventilador se termine el compresor Vea Fig 9 h gala girar lentamente para permitir que la unidad se adapte al nivel Cuando utilice THERMOSTAT aseg rese de esperar tres minutos
21. eaker To avoid the possibility of personal injury disconnect power to the unit before installing or servicing RECEPTACLE AND FUSE TYPES COOLING CAPACITY 5K RATED VOLTS AMPS 125 WALL OUTLET FUSE SIZE 15 Time Delay Fuse or circuit breaker Plug type Table 1 Tips before Installation Your Room Air Conditioner unit is designed to be highly efficient and save energy Follow these recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting 2 The filter is very efficient in removing airborne particles Keep air filter clean Normally filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality 3 Use drapes curtains or shades to keep direct sunlight from heating your room but DO NOT obstruct the air conditioner Allow three 3 inches around unit to circulate 4 Start your air conditioner before outdoor air becomes hot and uncomfortable This avoids an initial period of discomfort while the unit is cooling off the room 5 When outdoor temperature is cool enough use HI or LOW FAN ONLY This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting Your Room Air Conditioner was designed for easy installation in a single or double hung window NOT
22. enarla o transportarla en el futuro Antes de instalar la unidad compare el contenido del juego de herrajes con la lista de control del modelo correspondiente Consulte las siguientes listas Fig 1 Herrajes de Instalaci n gt Tornillos de 3 4 7 Sello 1 f Tornillos de 2 5 11 Espuma 1 Canal Superior 1 gt Sello del canal 1 Soporte en L 2 Cortina Lateral Derecha 1 Cortina Lateral Izquierda 1 Fig 1 Nota Tornillo Excedente Para d Uso de Reserva Herramientas Necesarias para la Instalaci n en Ventana Destornilladores Philips y de cabeza plana Taladro el ctrico broca de 1 8 pulgada de di metro L piz Cinta m trica Tijeras Nivel de carpintero Instrucciones de Instalaci n PRECAUCI N A F La unidad est dise ada para evaporar la condensaci n bajo condiciones normales No obstante bajo condiciones Debido a que el compresor se encuentra del lado de extrema humedad es probable que la condensaci n de los controles a la derecha de la unidad este excesiva haga que la bandeja base se desborde hacia el lado ser m s pesado y m s dificil de manipular exterior Por lo tanto la unidad deber instalarse en un lugar Si la unidad no se sostiene bien de dicho lado donde la descarga de la condensaci n no gotee sobre el pueden producirse lesiones f sicas y da os a la paso de peatones ni en las propiedades vecinas unidad y a su propiedad Por lo tanto le recomendamos que para instalar
23. entilador en secuencia autom tica baja media y alta baja y media son dela misma velocidad de ventilador BOTON TIMER Tem orizador Este botton no est disponible en el panel de control Se utiliza para programar o cancelar el funcionamiento del temporizador Cuando la unidad est en funcionamiento puede seleccionar OFF TIMER Apagar Temporizador Cuando la unidad est apagada puede seleccionar ON TIMER Encender Temporizador El rango de horas para programar el temporizador es de 0 a 24 horas Si selecciona OFF TIMER la pantalla del temporizador indicar durante 12 se gundos el tiempo restante para el apagado de la unidad y luego indicar la temperatura fijada Si presiona el bot n TIMER dentro de esos 12 segundos sedesactivar la funci n OFF TIMER Si selecciona ON TIMER la pantalla del temporizador indicar el tiempo restante para el encendido de la unidad Si desea cancelar la funci n ON TIMER presione el bot n TIMER O E Simbolos del indicador del panel del control Ventilador en He Enfriamiento velocidad autom tica A Ventilador en J Solo ventilador velocidad baja Ep Ventilador en Temporizador velocidad media gt Ahorro de energ a P Ventilador en velocidad alta Os Las luces del indicador LED anteriormente mencionadas se encienden cuando se usan los modos correspondientes Mostrar temperatura fijada Mostrar hora programada BOTON Av Se utiliza para fijarla temperatur
24. es muy eficiente a la hora de eliminar part culas que se desplazan por el aire Mantenga limpio el filtro de aire Por lo general el filtro deber limpiarse una vez al mes Es probable que sea necesario limpiarlo con m s frecuencia dependiendo de la calidad del aire exterior o interior 3 Puede utilizar tapices cortinas o pantallas para evitar que la luz directa del sol caliente su habitaci n pero NO obstruya el aire acondicionado Permita que el aire circule alrededor de la unidad sin obstrucciones 4 Encienda el aire acondicionado antes de que la temperatura exterior sea demasiado elevada y desagradable De esta manera evitar sufrir calor mientras la unidad enfr a la habitaci n 5 Cuando la temperatura exterior es lo suficientemente fresca utilice s lo HIGH FAN ventilador al m ximo o LOW FAN ventilador al m nimo Esto hace que el aire interior circule a una temperatura agradable y consume menos energ a el ctrica que si hiciera funcionar la unidad como enfriador de aire El Aire Acondicionado para Habitaciones se ha dise ado de modo tal que resulte f cil su instalaci n en ventanas armadas sencillas o dobles NOTA esta unidad NO se ha dise ado para ventanas verticales de tipo deslizante A PRECAUCI N A Para evitar problemas durante la instalaci n o el funcionamiento de la unidad lea completamente las instrucciones NOTA conserve la caja de la unidad y los materiales de empaque para almac
25. esta unidad solicite ayuda a otras personas 1 Seleccione la Mejor Ubicaci n A El aire acondicionado para habitaciones tiene un dise o que facilita su colocaci n en ventanas armadas sencillas o dobles No obstante debido a que los dise os de ventana son tan variados es probable que sea necesario realizar algunas modificaciones para lograr una instalaci n segura y adecuada B Aseg rese de que la ventana y el marco tengan una estructura firme y que la madera no est rajada ni podrida C Para lograr el m ximo rendimiento instale el aire 4 acondicionado del lado de la casa o edificio donde pared u haya mds sombra que sol Si la unidad se encontrara Obstrucci n otro expuesta a la luz del sol es aconsejable colocarle un lateral obst culo toldo encima D Deje suficiente espacio alrededor del gabinete para permitir una amplia circulaci n de aire a trav s de la unidad Vea Fig 2 La parte posterior de la unidad deber dar al aire libre y no a un garaje ni al interior de Requisitos para las aberturas de ventanas un edificio Mantenga la unidad lo m s lejos posible de consulte la siguiente tabla obst culos que puedan causar obstrucciones y por lo menos a 30 del nivel del piso o del suelo Deber n Modelo tomarse precauciones para evitar que las cortinas o paria p pa 5 S Tama o AW 05CM1FLU cualquier otro objeto dentro de una habitaci n r5 a 3 Tamano del gabinete 17 7 11 4 43 obstruyan el flujo de aire
26. he power supply cord must be replaced if it fails to trip when the test button is pressed or fails to rest Do not use the power supply cord as as an off on switch The power supply cord is designed as a protective device A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired The power supply cord contains no use serviceable parts Opening the tamper resistant case voids all warranty and performance claims INSTALLATION INSTRUCTIONS Unpack the Air Conditioner AWARNING EXCESSIVE WEIGHT HAZARD Use two or more people to move and install air conditioner Failure to do so can result in back or other injury Remove packaging materials Remove and properly dispose of packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fiuids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle air conditioner with care Introduction And Parts Identification Thank you for choosing this room air conditioner to cool your home This Use and Care Manual provides information necessary for the proper care and maintenance of your new room air conditioner If properly maintained
27. ien el filtro con agua limpia y luego s quelo completamente Cuidado de Fin de Temporada 1 Haga funcionar el ventilador durante medio d a para que se seque el interior de la unidad 2 Ap guelo y desench felo del tomacorriente de pared 3 Limpie el filtro 4 Almac nelo en un lugar seco Gu para la Soluci n de Problemas Generalmente los problemas son sencillos y es probable que nosea necesario llamar a un t cnico Esta gu a puede ayudarlo aresolverlos PROBLEMA CAUSA POSIBLE SOLUCI N SUGERIDA El aire acondicionado La unidad no recibe Verifique si el cable de alimentaci n e no funciona suministro el ctrico st conectado al tomacorriente Verifique el fusible o el cortacircuito Fije el FAN CONTROL control del ventilador en una posici n que no sea OFF Enfr a poco o nada Filtro de aire sucio Limpie o reemplace el filtro de aire Capacidad inadecuada Hable con el representante para para la aplicaci n determinar cu l es la capacidad E a i adecuada para la aplicaci n Flujo de aire obstruido Quite toda obstrucci n de la rejila o de Corte de energ a el ctrica las persianas exteriores se cambi de nivel H f tilad demasiado r pido o se aga funcionar el ventilador para dispar el interruptor por reiniciar el compresor en sobrecarga del compresor aproximadamente 10 minutos Unidad ruidosa Piezas sueltas Ajuste las piezas sueltas Soporte inadecuado Proporcione soporte adicional a l
28. ilas Retire la tapa de las en el sentido de la flecha Introduzca las pilas nuevas con cuidado de que coincidan los polos y Vuelva a instalar la tapa desliz ndola otra vez a su posici n Nota Utilice pilas 2LR6 AA 1 5V No utilice pilas recargables Sustituya las pilas por otras nuevas del mismo tipo cuando la pantalla aparezca atenuada Si la sustituci n se realiza en el plazo de 1 minuto el mando a distancia conservar los valores prefijados oridinales Este funci n es s lo para controlador remoto de LCD C c mo use Para operarel aire acondicionado apunte el controlador remoto la se ar del receptor El controlador remoto sera a operar el aire acondiciondo con una diatancia hasta 23 pies cuando apunta a lase ar del receptor de la unidad Receptor de se al Cuidado y Mantenimiento Cuando repare el aire acondicionado aseg rese de colocar la perilla de modo en OFF y luego desconectar el cable de alimentaci n del tomacorriente el ctrico 1 NO utilice gasolina bencina disolvente u otros productos qu micos en el aire acondicionado ya que estas sustancias pueden danar el acabado de pintura y deformar las piezas de pl stico 2 Nunca derrame agua directamente en el frente de la unidad ya que danaria el aislamiento el ctrico Limpieza del Filtro de Aire Si el filtro de aire se obstruye con polvo el flujo de aire queda obstruido y reduce el rendimiento de la unidad El filtro de aire de
29. n in Fig 6 While steadying the air conditioner carefully bring the window sash down behind the top channel of the unit as shown in Fig 7 Fix top channel to window sash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 7 If storm window presents interference fasten a 2 wide wood strip to the inner window sill across the full width of the sill The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference from the storm window frame as show in Fig 8 Top of wood strip should be approximately 3 4 higher than the storm window frame to help condensation to drain properly to the outside Install a second wood strip approximately 17 long by 11 2 wide and same thickness as first strip in the center of the outer sill flush against the back of the inner sill Screw the L brackets into this strip this will raise the L bracket as shown in Fig 8 Fig 8 Operating Instructions gt Mechanical control model Power ON will star the air conditioner OFF will completely shut off the unit See Fig 9 Fan Only Rotate the knob dial to the Fan Only mark the unit will circulate the air without cooling See Fig 9 Cooler Rotate the knob dial to the Cooler marks the unit will circulate the air with cooling To set desired cooling temperature simply rotate the knob to
30. n speed Timer High fan speed Above LED lights on when the relevant mode is in used Operating Instructions Remote control The remote control transmits signals to the system Temp Time 902 909279090 9 9 G ES Power button The appliance will be started when it is ener gized or will be stopped when it is in operati on if you press this button Timer button Used to set or cancel timer operation Mode button Used to select the operation mode Power Saver button Used to select the Energy saving mode Auto button Used to select the Auto fan speed mode Mid button Used to select the Mid fan speed mode High button Used to select the high fan speed mode Low button Used to select the Low fan speed mode buttons Used to set room temperature in COOLING mode or used to set time in TIMER mode NOTE 1 Changing modes during operation sometimes the unit does not response at once Wait 3 minutes 2 Wait 3 minutes before restarting the appliance Operating Instructions gt Remote control How to Insert Batteries Remove the battery cover according to the arrow direction Insert new batteries making sure that the and of battery are matched correctly Reattach the cover by sliding it back into position Note Use 2 LR6 AA 1 5volt batteries Do not use rechargeable batteries Re place batteries with new ones of the same type when the display beco mes dim Do not mi
31. ndow and frame is structurally sound and free from dry and rotted wood C For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight itis advisable to provide an awning over the unit D Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit The rear of the unit should be outdoors and neither in a garage nor inside of a building Keep unit as far away as possible from obstacles and obstructions and at least 30 above the floor or ground See right figure Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F Your unit was designed to evaporate condensation under normal conditions However under extreme humidity conditions excess condensation may cause base pan to overflow to the outside The unit should be installed where condensation run off cannot drip on pedestrians or neighboring properties Awning 20 Min es A A a E Fence wall or Side other Fig 2 see table below Size Model AW 05CM1FLU Re AW 05CR1FHLU MD 47 7 41 4 13 Min Window 24 Opening Max Window 3
32. re display LO Room Temperature above 38 C the Temperature display H1 FAN SPEED Used to select fan speed in sequence AUTO LOW MEDIUM and HIGH TIMER this button is not available on the control panel Used to set or cancel timer operation When the unit is in operation you can set OFF TIMER When the unit is off you can set ON TIMER Timer setting range is 0 to 24 hours If the OFF TIMER is set the timer LED displays the remaining time to turn off the unit for only 12 seconds then LED shifts to display set temperature If you press TIMER button within the 12 seconds OFF TIMER will be canceled If the ON TIMER is set the timer LED displays the remaining time to turn on the unit If you want to cancel ON TIMER press TIMER button AY Used to set room temperature in COOLING mode or used to set time in TIMER mode If the two keys are pressed at the same time the temperature LED display will alternate between T and F But the mark of C or F you can not change Usually those models used 220V 50Hz marked with C other models marked with F NOTE Temperature setting range is from 19 C 66F to 31 C 88F Control Panel TN CASO 4 18842 7 BEBE i i 4 JONO F FAN Gp SPEED MODE Indication symbols of LED on control panel F HR Display set temp Display set timer amp Cooling amp Auto fan speed 4 Fan only B Low fan speed Energy saving Medium fa
33. struction from grille or outdoor louvers Power interruption settings Let fan run to restart compressor change too quickly or in approximately 10 minutes compressor overload tripped Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Remove drain plug and drain base pan algae on wet surfaces Replace drain plug Clean unit thoroughly E A Y i Water dripping outside Condensation run off is normal Add flexible tubing to redirect water flow during hot and humid weather Water dripping inside Unit is not properly angled to Unit must be installed on an angle for proper allow water to drain outside condensation run off Check the unit and make adjustments Ice or frost build up _ Low outside temperature When outdoor temperature is approximately 65 F or below frost may form when unit is in cooling mode Switch unit to FAN ONLY operation until frost melts Unit air filter is dirty Remove and clean filter NOTE If circuit breaker is tripped repeatedly or fuse is blown more than once contact a qualified technician WARRANTY 1 One year full warranty For one year from the date of purchase by the original owner any part which fails in materials or workmanship under normal use the part will be replaced During this period all parts and service will be provided free of charge so long as th
34. su seguridad y protecci n esta unidad est iaa borda bd no se po h i E gt conectar ning n otro dispositivo o unidad a dicho conectada a tierra a trav s del cable de alimentaci n faible y coracirullo EEA IA DA ENE Dae Para evitar lesiones f sicas desconecte el provisto de conexi n a tierra Si no est seguro de suministro de energ a de la unidad que el tomacorriente de pared cuenta con la antes de instalarla o repararla conexi n a tierra apropiada consulte con un electricista licenciado 4 El tomacorriente de pared de 3 clavijas debe coincidir con el enchufe de 3 clavijas del cable de Tipos de Recepticulos y Fusibles alimentaci n suministrado con la unidad NO utilice 5K adaptadores de enchufe ni cables de extensi n Capacidad de Voltios Consulte la Tabla 1 para obtener informaci n acerca de recept culos y fusibles Amperios 5 El r tulo de la unidad contiene datos el ctricos y Tomacorriente de Pared t cnicos Dicho r tulo se encuentra en el lado derecho de la unidad Tama o del Fusible Fusible con Retardo o Cortacircuito Upa da enchula Tabla 1 Consejos antes de la instalaci n Su unidad de Aire Acondicionado para Habitaciones se ha dise ado para lograr un alto rendimiento y ahorrar energ a el ctrica Siga las siguientes sugerencias para lograr un mayor rendimiento 1 Ajuste el termostato a un nivel que le resulte agradable y d jelo en el nivel seleccionado 2 El filtro de aire
35. ual are not meant to cover all possible conditions and situations that may occur Common sense caution and care must be exercised when operating or cleaning tools and equipment Always contact your dealer distributor service agent or manufacturer about problems or conditions you do not understand A This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death D AN GER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury C AUTI ON CAUTION indicated a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicated a CAUTION potentially hazardous situation which if not avoided may result in property damage IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire electrical shock or injury when using your air 44 WARNING conditioner follow these basic precautions e Plug into a grounded e Do not use an extension cord 3 prong outlet e Do not remove e Unplug air conditioning ground prong before servicing Do not use Use two or more people to move an adapter and install air conditioner SAVE THESE INSTRUCTIONS Po
36. x old batteries with new ones Dispose of one old batteries properly If the replacement is done within 1 minute the remote control will keep original presetting How to Use To operate the room air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a dis tance of up to 23 feet when pointing at signal receptor of indoor unit Signal receptor Care and Maintenance When servicing the air conditioner be sure to turn the power switch to the OFF position and disconnect the power cord from the electrical outlet ACAUTION 1 DO NOT use gasoline benzine thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts 2 Never attempt to pour water directly on the front of the unit as this will cause deterioration of the electrical insulation Cleaning the Air Filter If the air filter becomes clogged with dust air flow is obstructed and reduces efficiency The air filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality Air Filter Removal The air filter on the above models is located behind the Air Inlet Grille To remove the air filter grasp the filter handle located on the up side of the Air Inlet Grille and slide the air filter to the up To reinstall the air filter reverse the above procedure dh