Home
Addonics Technologies RT3DAHEU3 User's Manual
Contents
1. Once raid array is verified you can set the buzzer either ON or OFF 6 Phone 408 453 6212 Email www addonics com support query Default factory DIP Switch setting SW1 RAID Setting DIP Switch BZS Error buzzer function EZ Automatic rebuilding to spare drive one of the drives on the raid is set as a spare If EZ is ENABLED anda drive failure occurs the spare will automatically act as a drive replacement and rebuilding will automatically start M2 RAID mode 2 M1 RAID mode 1 MO RAID mode 0 BZS EZ M2 M1 MO T Error buzzer function is ENABLED BZS when dip switch is in OFF position 2 Auto rebuilding to spare drive is DISABLED EZ 3 Individual drive mode is ENABLED MO M2 Note When the default factory RAID setting is used independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124 Sil3132 chip set or controllers that are Port Multiplier PM compatible Simultaneous DVD writing was tested using the Nero Burning Rom LED Pin Header J3 J P5 PO P1 P2 P3 P4 P5 PO P1 P2 P3 P4 Error LED Activity LED J1 Drive Activity LED P5 Activity LED for eSATA host port lights up when it is connected to a SATA controller card PO P1 P2 P3 amp P4 Activity LEDs for port 0 1 2 3 4 amp 5 light up when a drive is connected and blinks when there s drive activity J3 Error LED P5 error LED for eSATA host port P
2. Notes on Spare Drives using the Easy RAID Setting EZ When EZ is function is ENABLED the auto rebuilding to spare drive is automatic The degraded RAID group will start rebuilding automatically by using the existing spare drive Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required A Which port acts as a spare drive The last drive will automatically become the spare drive For a 3 drive RAID5 with spare Drives connected to SATA ports 1 3 belong to the active RAID5 array and drive connected to port 4 is the spare For a 4 drive RAID10 with spare Drives connected to SATA ports 1 4 belong to the active RAID10 array and drive connected to port 5 is the spare For a 2 drive RAID1 with spare Drives connected to SATA ports 1 amp 4 belong to the active RAID1 array and drive connected to port 5 is the spare When will rebuild action start When the raid fails and EZ is enabled the HPM XA will automatically rebuild the RAID group using the spare When the raid fails and EZ is disabled the HPM XA will NOT rebuild the raid group unless you install a good drive to replace the failed drive www addonics com Phone 408 573 8580 Fax 408 573 8588 Email http www addonics com sales query TECHNOLOGIES User Guide RAID Tower III RT3DAHEU3 www addonics com v8 1 11 Technical Support If
3. O P1 P2 P3 amp P4 error LED for port 0 1 2 3 4 amp 5 3 www addonics com Technical Support M F 8 30am 6 00pm PST Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program li For Windows users install the JMicron HW RAID Manager located on the SATA Controller CD In the CD go to Configuration Utilities gt JMB393 This manager can be use to create and monitor the status of the RAID volume It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager 2 Modify the RAID mode on the 5 port HPM XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux Mac amp Solaris Windows users can also use the procedure below Note Steps A to D need to be performed each time the raid mode is modified a Set the DIP switch to factory default setting BZS EZ M2 M1 MO b Press the RAID setting button with a ball point pen 9 While pressing the RAID setting button turn on the system power where the HPM is connected The buzzer will sound while holding the RAID setting button Release it after at least 5 seconds for hardware initialization A single beep will be heard to indicate initialization is completed The above steps act as a reset d Power off the system power 4 Phone 408 453 6212 Email www addonics com support query e On the DIP switch change MO to M2 setting
4. PST SW1 RAID Setting Notes When 2 drives are RAID 1 amp RAIRIO Mode connected to the HPM XA la and DIP switch is set to this setting the 2 drives will be configured as a 2 drive RAID1 array BZS EZ M2 Mi MO When 4 drives are connected to the HPM XA the 4 drives will be configured as a 4 drive RAID10 array Clone s action is similar to RAID1 However all of the hard drives will be mirrored Clone mode is useful especially when users like to copy data from a source hard drive to the drives connected to the HPM XA BZS EZ M2 Mi MO Press the RAID setting button with a ball point pen While pressing the RAID setting button turn on the system power where the HPM is connected The buzzer will sound while holding the RAID setting button Release it after at least 5 seconds for hardware initialization A single beep will be heard to indicate initialization is completed Verify if the RAID array is detected by the system If the 5 port HPM XA is connected to the motherboard onboard SATA on the CMOS setup utility the raid array will display as Addonics H W RAIDS if setup as a RAIDS array If the 5 port HPM XA is connected to an eSATA host controller card on the RAID BIOS the raid array will display as Addonics H W RAIDO if setup as a RAIDO array If booted into Windows in Disk Drives under Device Manager the raid array will display as Addonics HAW LARGE if setup as a LARGE array
5. to the desired RAID mode using the diagram below All settings on the diagram shows Error buzzer function is ENABLED EZ function is DISABLED RAID 0 Mode Clone Mode t E z z O 0 620 O SW1 BZS EZ M2 Mi MO BZS EZ M2 M1 MO RAID 1 amp RAID 10 Mode Large Mode 666 6 6 6 6 6 6 SW1 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 3 Mode Individual Drives Mode TE WE E Es E E i Ke 2 E E W E EE E O O O O O O O O O O SW1 BZS EZ M2 Mi MO BZS EZ M2 Mi MO RAID 5 Mode LE LE Le LE rs LL rs Zz LE O O O O O SW1 BZS EZ M2 Mi MO www addonics com Technical Support M F 8 30am 6 00pm PST SATA Ports Buzzer Error Alarm and Drive Activity Floppy LEDs Power Connector USB 3 0 2 0 Host Port Dip Switch eSATA Host Port Port 5 RAID Setting Button Dip Switch Settings Raid Mode Individual Drive Factory Default OFF i OFF 0 OFF OFF 1 and 10 OHF OFF 3 OFF OFF 5 OFF OFF ON OFF OFF ON OFF OFF OFF Enable Auto i Port Multiplier Mode ERR Buzzer Rebuilding Function to Spare Drive i 2 Phone 408 453 6212 Email www addonics com support query
6. you need any assistance to get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com support query Back View Power Jack USB 3 0 2 0 Host Port eSATA Port Dip Switch Installing Drive into the RAID Tower III Step 1 Secure 3 5 SATA hard disk drive into the tray of the disk array using the provided f screws Slide the drive into the drive bay Press the button labeled HD1 HD5 These are the power switches for each of the drives g Note It is recommended to fill up the RAID Tower III with SATA drives from top to bottom This is to help in identifying which drives connect to which ports for easier troubleshooting Connecting the power cable and RAID Tower Ill to the 7 computer i a Connect the power cord provided from the wall outlet to the back of the RAID Tower b Make sure the power is off power LED light should be off j C Connect either the provided USB or eSATA cable from the back of the RAID Tower to the computer We recommend connecting the eSATA port for best performance if this port is available on your computer Power On Off Control Turn on the power to the RAID Tower by pressing the power button on the front The power LED light should lit indicating the power is on www addonics com Technical Support M F 8 30am 6 00pm