1. GRAVITY ACCELERATION C 10 20 30 40 50 60 70 80 90 LATITUDE A amp D Company Limited 3 23 14 Higashi Ikebukuro Toshima ku Tokyo 170 0013 JAPAN Telephone 81 3 5391 6132 Fax 81 3 5391 6148 A amp D ENGINEERING INC 1555 McCandless Drive Milpitas CA 95035 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A amp D INSTRUMENTS LTD Unit 24 26 Blacklands Way Abingdon Business Park Abingdon Oxon OX141DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 lt German Scales Office gt Gro be Stra e 13 b 22926 Ahrensburg GERMANY Telephone 49 0 4102 459230 Fax 49 0 4102 459231 A amp D MERCURY PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A amp D KOREA Limited 8th Floor Manhattan Bldg 36 2 Yoido dong Youngdeungpo ku Seoul KOREA Telephone 82 2 780 4101 Fax 82 2 782 4280 7
2. INSTRUCTION MANUAL WM PD4001280A SJ 1000H SJ 2000H SJ 5000H SJ 12KH A amp D Company Limited SAFETY PRECAUTIONS All safety messages are identified by the following WARNING or CAUTION of ANSI Z535 4 American National Standard Institute Product Safety Signs and Labels The meanings are as follows A WARNING A potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION A potentially hazardous situation which if not avoided may result in minor or moderate injury product followed A WARNING A CAUTION O This manual is subject to change without notice at any time to improve the a Product specifications are subject to change without any obligation on the part of the manufacture 4 When using the SJ H the following safety precautions should always be Use only specified AC adapter for the scale Other adapter may cause damage AC adapter is optional Internal service or adjustment to this product should be performed by a qualified person Avoid installing the scale in direct sunlight which may cause discoloration or malfunctions Avoid over and or shock load that could cause damage to the scale Avoid using the weighing pan to move the scale as that could cause damage to the scale Do not mix the type of batteries Replace all other batteries at the same time If the scale is not to be used for a long period of time r
3. the scale by compensating the acceleration of gravity Refer The Value of Gravity at Various Locations 1 Set a new acceleration value When Cal is displayed press the UNITS key and 9798 will be displayed Press the RE ZERO key to increment the blinking digit and press the UNITS key to move the blinking digit 2 Store the value in memory While pressing the UNITS key press and hold the RE ZERO key and release the UNITS key Then the display will show end and return to Cal Turn the scale off to finish the procedure SPECIFICATIONS MODEL SJ 1000H SJ 2000H SJ 5000H SJ 12KH k g 10009x0 5g 2000gx1g 5000g9x2g 12 kg x 5g Capacity ip 2 2 Ib x 0 001 lb 4 4 Ib x 0 002 I 11 Ib x 0 005 Ib 26 Ib x 0 01 Ib PE oz 35 oz x 0 02 oz 70 oz x 0 05 oz 176 oz x 0 1 oz 423 oz x 0 2 oz lb oz 2 2 lb x 0 1 oz 4 4lbx0 10z 11lbx0 10z 26lbx1 oz Non linearity 1g 29 5 g 10 g Repeatability 1g 2g 5g 10g Span drift 0 015 C TYP 5 C 35C 41 F 95 F Operating temp 10 C 40 C 14 F 104 F Less than 85 RH No condensation Display 25 mm 0 98 inches 7 segment liquid crystal display Display update Approximately 10 times per second Power 4 x R20P LR20 D size batteries or AC adapter Battery life Approximately 800 hours with alkaline cells at 20 C 68 F Platform size 230 W
4. emove all batteries from the battery room to avoid leakage The scale is not watertight and avoid exposure to water PARTS DESCRIPTION Spirit level Display Four leveling feet STABLE indicator Indicates when the reading is stable Polarity ZERO indicator Indicates when the scale is at zero point Weighing Platform ON OFF key Turns the scale power on off UNITS key Changes weighing units k g Ib oz or Ib oz RE ZERO key Sets display to zero or subtracts weight of container Battery cover AC adapter jack Battery indicator Indicates battery remaining amount It turns on about for 10 seconds when powered on JAN C LILILI y Weighing unit k g Ib or oz depends on model NET indicator Indicates when NET weight is displayed Tare function is used Weighing unit Ib 0z depends on model PREPARATION Installing Batteries CAUTION m D E H al Take great care of the polarity of batteries The polarity marks are shown in the battery box Replace used batteries with four new ones when lb is displayed Do not mix used and new batteries Do not mix the battery type Remove batteries when the scale is not to be used for a long time Battery b
5. hen powered on Make sure no load is on the weighing platform or nothing touches the platform Ib Low battery replace the batteries or use the AC adapter Calibration may be required before weighing Read CALIBRATION first and if necessary calibrate your scale for accurate weighing Welghing Procedures Turn on the scale Press the ON OFF key to turn on the scale Then the scale displays all segments for a few seconds and then O will be displayed 2 Start weighing If you do not use a container for weighing Verify the reading is 0 If not press the RE ZERO key to display Place objects on the weighing platform to weigh When the reading becomes stable the stable indicator is displayed If you use a container for weighing Place an empty container on the platform Wait for the stable indicator to be displayed and press the RE ZERO key Place the objects to be weighed in the container When the reading becomes stable the stable indicator is displayed Select the weighing unit Press the UNITS key to select weighing unit either k g Ib oz or Ib oz The scale will power up with the weighing unit that had been used when turned off last time o 4 CALIBRATION When to Calibrate Calibration may be required when it initially installed or it is moved a substantial d
6. istance Also periodical calibration will be recommended ac using a Calibration Weight Calibration switch Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO and UNITS keys press the ON OFF key Cal will be displayed Or remove the calibration switch cover on the bottom and press the calibration switch while in the weighing mode Then cal will be displayed 2 Zero calibration Press the RE ZERO key to calibrate zero Cal O will be displayed Wait for the stable indicator to be displayed and press the RE ZERO key Cal f will be displayed in a few seconds If the zero calibration only is to be done press the UNITS key The scale will automatically return to the weighing mode 3 Span calibration When Calf is displayed place the weight at the center of the platform Wait for the stable indicator to be displayed then press the RE ZERO key The display will show end and the scale will automatically return to the weighing mode See SPECIFICATIONS about the calibration weight Calibration switch cover Calibration by Gravity Compensation The scale is calibrated at 9 798 m s at the factory If the acceleration of gravity at your location is not same and if you do not have calibration weights you can calibrate
7. ox New four batteries R20P LR20 D size Battery cover Slide the battery cover downward to open Push the battery box to unhook and pull it out Insert new four batteries R20P LR20 D size into the battery box taking extreme care of the polarities Batteries are not included with shipment Connecting an AC adapter Optional Open rubber cap used so please verify that the adapter is correct Open the rubber cap and plug the AC adapter The AC input requirement could be 100 120 or 230 volts 50 60Hz depending on the area where A Setting up the Scale AC adapter plug Place the scale on the firm surface and adjust the feet so that the sprit level shows the scale is level for an accurate weighing OK NG WEIGHING Before Weighing Automatic power off function If the scale left ON and the stable indicator is displayed an automatic power off function turns power off after approximately 5 minutes To disable enable this function turn the scale on while pressing the RE ZERO key Then poff 0 or poff 1 will be displayed poffo Function disabled pof f 1 Function enabled Select the setting by pressing the RE ZERO key which toggles the display above and press the UNITS key The scale shows end and returns to the weighing mode Error message e Overload remove excess load on the weighing platform The scale zero is out of zero range or unstable w
8. x 190 D mm 9 05 W x 7 48 D inches 265 W x 250 D x 103 H mm Dimensions 10 4 W x 9 8 D x 4 1 H inches Weight Approximately 1 9 kg 4 2 lb Calibration weight 1000g 0 1g 2000g 0 2g 5000g 0 5g 10 kg 1g Accessories This manual Options AC adapter The Value of Gravity at Various Locations Amsterdam 9 813 m s Havana 9 788 m s Rio de Janeiro 9 788 m s Athens 9 807 m s Helsinki 9 819 m s Rome 9 803 m s Auckland NZ 9 799 m s Kuwait 9 793 m s San Francisco 9 800 m s Bangkok 9 783 m s Lisbon 9 801 m s Singapore 9 781 m s Birmingham 9 813 m s London Greenwich 9 812 m s Stockholm 9 818 m s Brussels 9 811 m s Los Angeles 9 796 m s Sydney 9 797 m s Buenos Aires 9 797 m s Madrid 9 800 m s Taichung 9 789 m s Calcutta 9 788 m s Manila 9 784 m s Taiwan 9 788 m s Cape Town 9 796 m s Melbourne 9 800 m s Taipei 9 790 m s Chicago 9 803 m s Mexico City 9 779 m s Tokyo 9 798 m s Copenhagen 9 815 m s Milan 9 806 m s Vancouver BC 9 809 m s Cyprus 9 797 m s New York 9 802 m s Washington DC 9 801 m s Djakarta 9 781 m s Oslo 9 819 m s Wellington NZ 9 803 m s Frankfurt 9 810 m s Ottawa 9 806 m s Zurich 9 807 m s Glasgow 9 816 m s Paris 9 809 m s ALTITUDE Sea Level 300m 1000 ft 600m 2000 ft 900m 3000 ft 1200m 4000 ft 1500m 5000 ft 1800m 6000 ft 2100m 7000 ft

Download Pdf Manuals

image

Related Search

Related Contents

Regulamento de Avaliação da Conformidade para  VP-9116 user manual  Philips SatinPerfect HP6578  BoConcept Sintra Assembly Instruction    151096100 manual usuario radio sp4300av pt r0    Bedienungs- und Instandhaltungsanleitung Operating Manual and  Sony VGN-SR410J/B User's Guide  Panasonic KX-UT1XX Quick Start Guide  