A&D PD4001163 User's Manual
Contents
1. 5 Display 5 symbols SVIMDOIS Arinen sere r see oae nr renteee aoe EEEE 6 Using the Monitor Installing Changing The Batteries 7 Connecting the Air Tube 7 Selecting the Proper Cuff 7 Attaching The Alin Cuf Arr 7 Measurements 8 Useful Features 9 Trobleshooting Troubleshooting 2 22 7222 2 02 ennnennene 9 Maintenance 7 7 7777 7 10 Technical Data 10 SS Se a i Weletome ia Aa Congratulations on purchasing a state of the art A amp D sonygmomanometer one of the most advanced monitors available on the market today Designed for ease of use and accuracy this monitor will facilitate your daily blood pressure regimen We recommend that you read through this manual carefully before using this device for the first time Applicable Patient This spohygmomanometer is designed to be used by adults Environment for use The device is for indoor use Features Measurement L This sohygmomanometer is designed to monitor an
2. measurement If air is remaining in the cuff when the ON OFF RE 5 button is pressed the display will show an error code Err 1 cat a m g g Switch off the device press ON OFF button again and turn bp the exhaust valve counterclockwise once to expel all the air in ee the cuff Then press the ON OFF button again to reactivate re the device um a Place the stethoscope on the humerus artery and pressurize the cuff by squeezing the rubber bulb Make sure the exhaust valve is completely closed L While the cuff is inflating the pressure bar will move and in turn the LCD will display a number indicating the pressure Inflate the cuff to 30 to 40 mmHg higher than the patient s expected systolic value Note If you wish to stop inflation at any time press either the ON OFF button or turn the screw of the exhaust valve to release air 4 When inflation is complete E Turn the exhaust valve screw to release air slowly The systolic pressure and the diastolic pressure are measured by stethoscopy 5 The pulse rate is shown on the numerical display when the measurement is complete and meets the following conditions Li When you pressurize 80mmHg or higher for the measurement I When the pressure drops to 20mmHg or lower 6 Turn the exhaust valve screw counterclockwise to release all the air from the cuff E lf a measurement is taken with insufficient pressure the mark will be displayed R
3. Pressure vae holding andiieime counter imaa O Battery installation guide o sn fseanmer S 2002 Date of manufacture ooo o o Type BF Device cuff and tubing are designed to provide special protection against electrical shocks p Full The battery power indicator during Battery measurement Replace all batteries with new low The battery is low when it blinks ones when the indicator h blinks Er 1 valve pe i E 0366 EC directive medical device label ee WEEE label A 3mm ZY ee Pil zN Rom uu Usinglthe Monitor iL Installing Changing the Batteries 1 Remove the baitery cover 2 Insert a new set of batteries into the battery compartment as shown Make sure the polarities and are correct Use only LR6 AA or equivalent batteries 3 Close the battery cover Peete Hts zt IEE ANT pee nn ERR HiH sl ninanta K HE hi G R isah PAA EAE a E i iH sin HA l h rit Kd SHERR Pepteetiemuuttpt ttt zt pi R CAUTION _ Insert the batteries in the battery compartment If not the device will not work 1 When 1_4 LOWBATTERY mark blinks in the LCD display replace all batteries with new ones Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LI Battery life varies with the ambient temperature and may be shorter at low temperatures L Use the specified batteries on
4. 61 8 8352 7409
5. ENABLE H BAT BPE eee reer SPE EEE EE i EEHEEHE RRHWA GRE BURMA ARAB ii adn THEA EHR HERA AHR hunnun ununanuud p h sapii HHH BL aE Bed CoE EE eer ae Wi 1313391 Hi H 124333 HEREBY FL ae j H a i a a tal a iiaiai an l i 4 Pe ea f jfi ilaji ial i H Al a fi we FRR RHEE Hh sear reenter an a ae ce ee a a pene j i Item Specification O O O O Z UM 101 Measurement method Stethoscopy with stethoscope Measurement range Pressure 0 300 mmHg Numerical display Pulse 30 200 beats minute Measurement range l Bpascire badena Pressure 20 280 mmHg Measurement accuracy Pressure 3mmHg Numerical display Pulse 5 A Pressure 4mmH Pressure bar displa g Classification TypeBF Z o Z o 10 C to 40 C 30 RH to 85 RH 20 C to 60 C 10 RH to 95 RH 0366 Note Specifications are subject to change without prior notice 10 AIND A amp D Co LTD 1 243 Asahi Kitamoto shi Saitama 364 8585 JAPAN Telephone 81 48 593 1111 Fax 81 48 593 1119 A amp D INSTRUMENTS LTD lt Authorized Representative Established in the European Community gt Unit 24 26 Blacklands Way Abingdon Business Park Abingdon Oxon OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A amp D MERCURY PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8352 3033 Fax
6. T T eer TD INSTRUCTION MANUAL Digital Sohygmomanometer A amp D Medical WM PD4001163 ENGLISH ehune RHR HH f KHan Bri geentt NG HARSH RRHH HHHRHTEEN inima REEERE H Ei 4 i HEHANTH EFEBEEECEE TERE Bea i y inni FH HHRH HH i ii pea stipieesere i t afi H ARAR FH bt RRE ii i Hil Ra nisitt j n pE q HTH j mo Em g Wo gf a pi phe e f F ng E H H i aa fiiia henin i 3 i h El ao iep Snl i i i HEREHERE lt at i E dipapa i i 2 _ a if a a Feaeal Welcome FCaluleS 25h eae A ee ees ren ean eae ates chi Racial cece 2 Preliminary Remarks Compliance aw an nen nn nnn nn nn nnn nn nn nn nn nnn nnn nnn 2 Definito e aa ts See i eee eee es 2 Patt ric Sa ee 3 A Defective Sphygmomanometer 3 Taining 3 Repair 7 7 3 Blood Pressure Measurement 3 Notes for Proper Use Storage 3 er eNO Co ee ee ae ne are ree eee ee 3 During Use 4 After Use 7 7 4 Periodic Maintenance 2000 rn nnn n nnn nnn 4 Parts Identification Main Body and Accessories
7. ce Lo and request a full service After Use Clean the device cuff and accessories before any subsequent uses Do not pull or kink the tubings Do not use any organic solvent for example antiseptic solution etc to clean the device Press the ON OFF button after a measurement You are advised to keep the original box for further transportation after purchasing the device Periodic Maintenance This device is a precision instrument and contains electronic circuitry Please check all functions periodically Contact your nearest A amp D authorized representative for official calibration check up according to your local regulations i Main Body and Accessories HI Ee e ERTH at al AES Pressure bar display Cuff connector Numerical displa MARKER button ON OFF button Exhaust valve Rubber bulb Display Unit of pressure Pressure value Battery indicator Pulse value Unit of pulse Lifetime counter Penal Wa a HIT ABEEOAON pana 7 bat I Hiji DEE EEEEEEEHEENEEEEEEEEE E EEEFEFEEEEEEEHI H M t I ijai FEEFEE M EEREEFEFFEEER AE t ij HHHT tl ifi Haat EhhH init igili H i E HEHHE BH H i E H J FRH Igt i Aye ifi fit tn il H EE il tl H il ff ft i afapEgapEpategceeyapeeepegeTERr t iign h EY EEEEEEEEESES EE ekrk Hada a tt PcyEEeEEe Fi BEFEREECESEEREELEIH ET Haili Standby andturnthedeviceon _ _ _ MARKER
8. ctly oroperiy Patient moved arm or body Make sure the patient remains very still during the measurement during the measurement SENE Sit comfortably still The unit does The cuff position is not Ensure that the cuff is at the same level not take a correct as the heart measurement Readings are too high or too low Remove the batteries Reinstall them properly and try the measurement again Note If the recommendations above do not solve the problem contact your nearest authorized A amp D representative Do not attempt to open or repair this product by yourself as any attempt to do so will render your warranty invalid If you have a very weak or irregular heart beat the device may have difficulty in determining your blood pressure VTE j Do not attempt to open the device as the delicate electrical components and intricate air unit inside could be damaged If you cannot solve the problem using our troubleshooting guide request assistance from your dealer or from any A amp D service group The A amp D service group will provide technical information spare parts and units to authorized dealers The device was designed and manufactured for a long service life However it is generally recommended to have the monitor inspected every 2 years to ensure proper functioning and accuracy Please contact either your authorized dealer or A amp D for maintenance ov KERN HHN
9. d display the cuff pressure during cuff inflation and deflation while the healthcare provider determines the patient s blood pressure level by listening for Korotkoff sounds Easy to Use L This sohygmomanometer measures the pulse rate of a patient while the cuff is deflating during blood pressure measurement and indicates the pulse rate on the LCD display Safety L This sshygmomanometer was designed to measure a patient s blood pressure without the use of mercury therefore protecting your local environment I An automatic quick exhaust valve is installed in the device to prevent over pressurization of 320mmHg or higher therefore protecting the patient Preliminary Remarks TI Compli lance Compliance with European Directive 93 42 EEC for Medical Products The device conforms to the following requirements European Directive 93 42 EEC for Medical Products Medical Products Act European Standards for Electrical Medical Equipment EN 6060 1 General Safety Provisions EN 60601 2 30 Particular Requirements for the Safety of Automatic Cycling Indirect Blood Pressure Monitoring Equipment EN 60601 1 2 and EN 55011 Electromagnetic Compatibility European Standards pertaining to Non Invasive Blood Pressure Instruments EN 1060 1 General Requirements prEN 1060 3 Supplementary Requirements for Electrome chanical Blood Pressure Measuring Systems The above is evidenced by the CEo366 mark of conformity accompanied by the reference number to th
10. e involved notified body This device is designed for adults only pa ze Definitions SYS Systolic Blood Pressure DIA Diastolic Blood Pressure PUL Pulse Exhaust This means releasing the cuff air as soon as possible Constant exhaust This means releasing the cuff air at a constant depressurization rate O O L DUCO O OUOOUW O Use alkaline batteries LR6 type AA type Mignon or equivalent batteries Do not mix new and used batteries Remove the batteries if the device will not be in use for a prolonged period of time as the batteries may leak and cause a device malfunction A Defective Sphygmomanometer Stop the examination immediately if the sohygmomanometer does not work properly Please attach a note with the following Do not use this sohygmomanometer to prevent any further use This defective device should be stored in a safe place to avoid any misuse until it has been sent for repair Training The healthcare provider should stop the examination if there is an abnormality such as a patient feeling excessive arm pain and remove the cuff to protect the patient Repair Do not attempt to open the device Contact your nearest A amp D authorized representative and they will repair or replace the device Blood Pressure Measurement This sphygmomanomeiter is designed for use with adults Do not use the device on patients using heart lung support equipment Do not use the device on patients in a cri
11. e pressurize the cuff to a pressure that is about 30 to 40 mmHg higher than the previous attempt L An error message r r will be displayed if a measurement is taken with insufficient 7 pulses or in a very noisy environment Press the ON OFF button again to turn off the power Note Model UM 101 is installed with an automatic power off function ee ae ne i A H t cee ee a i a ton tal le ie ad _ Measurement with MARKER Button You can put a marker at a certain pressure value when the MARKER button is pressed during the measurement process Up to 5 markings can be shown over the range of 40mmHg LI Lifetime Counter When the MARKER button is pressed while the device is off the lifetime counter is displayed This counter function shows the hours the device was in use and helps to determine when maintenance is necessary High digits and Low digits are alternatively displayed The example below indicates that the device has been in use for 1 278 hours Example High digit Low digit Wu Troubles oe Getto Bee ooooereee Batteries are empty Replace all batteries with new ones Reinstall the batteries with their negative and positive ends matching those indicated in the battery mpartment Nothing appears in the display even when the power is turned on Battery polarities are not in the correct position The cuff is not fastened Fasten the cuff corre
12. ly The batteries provided with the device are for testing monitor performance and may have a limited life Ll Remove the batteries if the device will not be in use for a prolonged period of time as the batteries may leak and cause a device malfunction Connecting the Air Tube Insert the air tube into the cuff connector firmly Selecting the Proper Cuff Using the correct cuff size is important for accurate readings If the cuff is not the proper size the reading may yield an incorrect blood pressure value _ The index and range marking on the cuff will indicate that you are using the proper cuff or not Refer to Attaching the Arm Cuff in next section Arm size The circumference at the biceps Attaching the Arm Cuff 4 1 Wrap the cuff around the upper arm about 2 3 cm b above the elbow as shown on right Place the cuff directly against the skin as clothing may cause a faint pulse and could result in a measurement error 2 Constriction of the upper arm caused by rolling up a shirtsleeve may interfere with accurate readings 3 Make sure that the index points are within the range 2 3 cm gt 6 p J Rubber bulb O When O starts flashing the device is ready for 3 Place the cuff on the arm preferably the left arm Keep the patient still during measurement Press the ON OFF button When the ON OFF button is pressed all of the display symbols will appear for about one second
13. tical condition or on ICU intensive care unit patients SSS SSS se Do not store the sohygmomanometer in the following places Where the sphygmomanometer could be splashed with water or other liquids If the sphygmomanometer is immersed by accident it may require servicing DO NOT use the sphygmomanometer before it has endured a full service Do not leave the device in a high temperature or high humidity environment or in direct sunlight Do not leave the device where it could be influenced by vibration or shock Do not leave the device in a dusty salty or sulfuric environment Do not leave the device where medicines are stored or where medicines are evaporating Before Use Make sure that the sohygmomanometer works correctly and that measurement values are accurate Make sure that the cuff and air tubes are properly connected Check and maintain the cleanliness of the parts in direct contact with the patient Consider using a cuff cover for sanitary measurements Avoid placing the device near a strong magnetic field or static electricity Avoid placing the device near high frequency surgical equipment 3 L Sper a During Use This device should be used by trained professionals Stop the examination immediately if the patient feels pain during a measurement or if the device does not work properly Ll Stop using the device if you notice any abnormalities for example liquid inside the devi