1. essere 17 10 3 24 RS 232C serial interface and relay output 20 11 nigro hi o1 21 11 1 Notes on maintenance sse om itd X ORE DERE PRO PR 21 EREE E 21 12 SPECIFICATIONS nn 22 12 1 Specifications esit dd EI 22 12 20 DIMENSIONS 23 GRAVITY ACCELERATION MAP 1 NTROD This manual describes how this scale works and how to get the most out of it in terms of performance FG series platform scales have the following features The FG series has three kinds of weight display resolution 1 3 000 1 6 000 1 7 500 and 1 12 000 1 15 000 There are 2 sizes of weighing pan The FG KAL has a larger pan and the FG KAM KBM has a smaller pan The FG KAL KAM has a display column and the FG KBM is a without column model You can select a model that suits your own application As power source you can use AC adapter or C size dry batteries The counting function easily counts the number of articles of the same weight The comparator function compares the display value with upper limit and lower limit The display shows the result and the optional FG 24 can output it as a relay signal The optional FG 23 and FG 24 has an RS 232C interface and can output the weighing data to connect with a printer computer
2. 4mn PRINT switch It may be set to 5 10 20 50 ZERO EU 100 4 If necessary place a container on the weighing pan and press the switch Confirm that the right side of the number of samples shows zero 5 Place the correct number of samples on the pan or in the container 6 Press the MODE switch to calculate and store the unit weight Remove the sample The l scale is set to count objects with this unit weight LL The total weight of sample pieces should be more than below regardless of number of sample pieces FG 30K 2564 FG 60K 62 54 FG 150K 125g lf not the display shows Lo ut and returns to the previous display Increase the number of samples go to step 3 and try again pressing the MODE switch without adding sample pieces or adding enough weight to be acceptable as a unit weight the display leaves counting mode and switches to the next weight unit 7 Place the objects to be counted on the pan 1 1 l Unit weigh is maintained even if the scale is powered off ama t of one piece from sample pieces and calculates 7 COMPARATOR The results of the comparison are indicated by OK or LO on the display The formula to compare is as follows LO lt Lower limit value OK Upper limit value lt HI Operating conditions see the Function list F6 _ F6 0 No comparison comparator function disabl
3. 150 Dimension Factory setting 60 Ib 150 Ib 300 Ib 150 Ib 300 Factory setting 42054 im 12 2 Dimensions FG 60KAL FG 150KAL 781 FG 30KAM FG 60KAM FG 150KAM 781 FG 30KBM FG 60KBM FG 150KBM ee i n AH 23 mm LATITUDE G RAVI TY ACCELERATION Values of gravity at various locations Amsterdam 9 813 m s Athens 9 807 m s Auckland NZ 9 799 m s Bangkok 9 783 m s Birmingham 9 813 m s Brussels 9 811 m s Buenos Aires 9 797 m s Calcutta 9 788 m s Cape Town 9 796 m s Chicago 9 803 m s Copenhagen 9 815 m s Cyprus 9 797 m s Djakarta 9 781 m s Frankfurt 9 810 m s Glasgow 9 816 m s Havana 9 788 m s Helsinki 9 819 m s Kuwait 9 793 m s Lisbon 9 801 m s London Greenwich 9 812 m s Los Angeles 9 796 m s Madrid 9 800 m s 9 77 1f 9 7 e co 9 7 je o i e i e u gt o T RM g e oco Manila Melbourne Mexico City Milan New York Oslo Ottawa Paris Rio de Janeiro Rome San Francisco Singapore Stockholm Sydney Taichung Taiwan Taipei Tokyo Vancouver BC Washington DC Wellington NZ Zurich 89 o ACCELERATION DUE GRAVITY 24 9 784 m s 9 800 m s 9 779 m s 9 806 m s 9 802 m s 9 819 m s 9 806 m s 9 809 m s 9 788
4. is a defect in the memory device If you cannot cancel an error or other errors occur request service from the store where you purchased the product or to your A amp D dealer 21 712 SPECIFICATIONS 12 1 Specifications FG 30KAM FG 60KAM FG 150KAM MODEL EG 30KBM FG 60KBM_ FG 150KBM FG 60KAL FG 150K Min display 35 0 05 0 02 00415 0 02 002 0065 001 9005 0 01 Ib 0 02 0 05 005 oor 00 90 0 02 02 ee ee Oe 5 be changed to 10 20 50 100 pieces counts 120 000 pcs 96 000 pcs 120 000 pcs 96 000 pcs 120 000 Mincuntwelght 0 259 0 6259 1 259 0859 _ 1 25 ey deviation 0 005 kg 0 01 kg 0 02 kg 0 01 kg 0 02 Linearity error 1001 00 906 002 0 0 05 20 ppm 10 30 50 862 7 segment LCD display Character height 26 mm Display update 10 times per second 10 40 14 F 104 F less than 85 non condensing AC adapter or C size R14P LR14 x 4 batteries Approximately 150 hours with alkaline dry cell battery Weighing pn 300 x 380 mm 11 8 x 15 0 in Sr MA size 95 15 4 x 20 9 in FG KAM 300 W x 624 D x 781 H mm 11 8 W x 24 6 D x 30 7 H in 390 W x 771 D x 781 F 380 W x 464 D x 118 H mm 15 400 x 30 4 D x 30 7 _ 15 0 W x 18 3 D x 4 6 H in Weight FG KAM 11 2 kg 16 4k approximately FG KBM 9 7 kg alibrati
5. Ib to enter calibration mode 5 Make sure that there is nothing on the weighing pan n and wait until the STABLE indicator turns on n 4 Press the MODE switch The scale calibrate the 2 zero point and the display shows SPn 1 and the a Amr weight value to calibrate SPAN calibration L C The weight value is equal to the capacity When you enter with kg mode then the value is kg Entering with Ib then Ib If you do not need SPAN calibration turn the power off to exit from the calibratio procedure 5 To calibrate with the different weight change the displayed value using the followin switches RE ZEHO or ZERO select the digit blinking to change PRINT Increment the value of the selected digit 12 5 Place the calibration weight on the pan with the same m ri value as displayed and wait until the STABLE SHELL indicator turns on 7 Press the MODE switch The scale calibrate SPAN x and will appear End Remove the weight from the pan and turns the power off Ci Note value set in step 5 is cleared after the power is switched if the scale will suppose to move to another location set the gravity acceleration value for the current location and calibrate the scale according to the procedure above See the next section to set the value e 8 2 Gravity acceleration correction When the scale i
6. and so on 2 UNPACKING When unpacking check whether all of the following items are included _ FG30KAM 60KAM 150KAM FG60KAL 150KAL Column support foot FG KAM only Protective cover is attached All models Scale Shape is different by model adapter Instruction manual Please confirm that the AC adapter type 15 correct for your local voltage and receptacle type INSTRUCTION MANUAL Display pod Display column CAL switch cover Cable cover Weighing pan FG KAL KAM Support foot FG KAM only 72 dn Leveling foot FG KAL KAM series Spirit level FG KBM series Metric models LCD display Ae STABLE indicator Il e OK LO indicator indicator ZERO indicator ON OFF switch PRINT switch M DE Switch RE ZERO switch 3 U S A models ON OFF switch y PRINT switch ZERO switch TARE switc MODE switch Indicators STABLE Indicates when the reading is stable NET lt Indicates when NET weight is displayed Tare function is used Indicates when the scale zero is correct Indicates when the scale zero is correct Weighing u units kg and pcs for metric models oz kg and pcs for U S A models Swiiches _ON OFF Switch ON OFF Used to turn the power When turned on the scale will be au
7. dry cells into the battery case 5 Push the battery case into the display pod as before 6 Attach the battery cover 1 Take great care of the polarity of batteries The polarity marks are shown in the baitery case 1 Replace used batteries with four new ones when 1 bU s displayed 2 Do not mix used and new batteries It may cause damage to the battery or product if used CJ Do not mix the battery type It may cause damage to the battery or product LJ The battery life depends on the ambient temperature LJ Remove baiteries from display pod when the scale is not to be used for a long time They may leak and cause damage C Damage due to battery leakage is not covered by the warranty 6 Remove the object from the weighing pan The switch will zero the scale if the weight is within 2 of the weighing capacity kg around the power on zero point The ZERO indicator turns on When the weight exceeds 2 of the weighing capacity kg it will be subtracted to zero as a tare weight In this case the ZERO and NET indicators turn on The switch will zero the scale if the weight is within 2 of the weighing capacity kg around the power on zero point The ZERO indicator turns on When the weight exceeds 2 of the weighing capacity kg the switch does not work The TARE switch will subtract the weight to zero as tare weight when the weight is a plus value Precautions during operation
8. m s 9 803 m s 9 800 m s 9 781 m s 9 818 m s 9 797 m s 9 789 m s 9 788 m s 9 790 m s 9 798 m s 9 809 m s 9 801 m s 9 803 m s 9 807 m s gt ed Sea Level 9 835 Sea Level 300m 1000 it 600m 2000 ft 900m 3000 ft 1200m 4000 ft 1500m 5000 ft 1800m 6000 ft 2100m 7000 ft gt g m s H NIZC SE PIPL IAL 4 5 42 20086858
9. stable power source is available Install the scale on a solid and level surface LJ Do not install the scale in direct sunlight Do not install the scale near heaters or air conditioners 2 Do not install the scale where there is flammable or corrosive gas present Do not install the scale near equipment which produces magnetic fields LI Do not install the scale where there is apt to be static electricity in a place where the relative humidity is lower than 45 RH Plastic and isolators are apt to be charged with static electricity LE Do not use an unstable power source sees 12 When the scale is installed for the first time or the scale has been moved carry out calibration as described in 8 CALIBRATION 4 3 Power source For the power source the AC adapter or C size dry cells can be used When using the AC adapter Use a stable power source To use the AC adapter insert the AC adapter plug into the AC adapter jack on the rear side of display pod LJ Confirm the AC adapter type is correct for your local voltage When using the batteries Prepare 4 x C size R14P LR14 dry batteries The batteries are not included in the product The scale can be used continuously for about 150 hours using the alkaline batteries 1 Turn of the scale and disconnect the AC adapter if used 2 Slide the battery cover off E E 3 Push the battery case inside the display pod and take it out 4 Insert four new
10. F5 2 When the PRINT switch is pressed while the weighing data is stable STABLE indicator is on the scale transmits the data LJ Auto print mode data Function setting F5 3 The scale transmits the weighing data when the display is stable STABLE indicator is on and the data is more than 44 or less than 4d of weight data d minimum weight display see 12 1 Specifications When in counting mode d is equal to minimum weight display of kg mode The next output can be obtained after the display returns to between 4d and 44 1 Auto print mode data Function setting F5 4 The scale transmits the weighing data when the display is stable STABLE indicator is on and the data is more than 44 of weight data d minimum weight display see 12 1 Specifications When in counting mode d is equal to minimum weight display of kg mode The next output can be obtained after the display returns to below 44 Command mode Function setting F5 1 In the command mode the scale is controlled by commands that come from the personal computer and so on Command list command Command to request the current weighing data Command Q Z command Same operation as the RE ZERO ZERO switch Command This command works as RE ZERO for the metric models and as ZERO for U S A models command operation as the TARE switch _ Command This command wo
11. G KAM 1 First remove the 4 screws from the bottom of the display column mE Screws 2 Set the display column to the base by pulling the cable into the base Take care not pinch the cable between the column and the base 3 Tighten the 4 screws removed at step 1 to fix the display column firmly 4 Tilt the display pod forward by pressing in on the two round side clamps and slide off the cable cover 5 Pull the bundle of cable out from the top end of display column feeding all of slack of the cable on the base into the display column LJ Take care not scratch the cable 264 Neither sla 5 Nortensior 6 Put the bundle of cable back into the display column 7 Make sure the cable is fitted to the 2 cable guides and attach the cable cover Cable guide 8 Place the weighing pan on the base 4 2 Installing the scale 1 Select the place for installing the scale Refer to Cautions for installing the scale below 2 Adjust the level of the base using the spirit level and leveling feet The FG KAM has an extra foot under the display column Adjust this foot to reach floor after adjusting the level of the base 3 Tilt the display pod by pressing in on the two round side clamps Cautions for installing the scale Consider the following conditions to get the most out of your scale LJ Install the scale where the temperature and relative humidity is stable There is no and a
12. N mE 2 Mi p rel c 2 3 NAMES AND FUNCTIONS 3 4 SETTING UP c ER 6 4 1 Attaching a display pod to the base FG KAL and FG A 6 4 2 Installing Pe d 6 4 3 Power 0 7 5 BASIC OPERATION c 8 5 1 Turning the power ON and OFF TUM m 8 5 2 Salacting aWelghihg UNI 8 5 3 Basic operation T 8 5 4 Weight display T berum 9 6 COUNTING 2 2222 2 1 2 1 400 ER 10 7 COMPARATOR ews UN EE 11 S CALIBRATION cic cr CEPR ORARE ERE PER EE SE Chev 12 8 1 Calibration using a weight 12 8 2 Gravity acceleration correction 13 lt 14 9 1 The procedure for setting parameters 14 9 2 PHIMCHOM 15 10 TT eese 1B 10 1 Installation of 23 24 16 10 2 OP 23 RS 232C serial interface
13. Q Make sure that the STABLE indicator is on whenever reading or storing a value Do not press switches with a sharp implement such as a pencil Do not apply a shock load to the scale Do not place a load onto the pan that exceeds the capacity Q Keep the scale free from foreign objects such as dust or liquid 1 Calibrate the scale periodically to keep weighing accuracy See 8 CALIBRATION 5 4 Weight display resolution The FG series has three kinds of weight display resolution NORMAL HIGH and HIGHER The following is about kg and Ib display for reference see the 12 SPECIFICATIONS in detail NORMAL 1 3 000 HIGH 1 6 000 1 7 500 depending on capacity HIGHER 1 12 000 1 15 000 depending on capacity The factory setting is the HIGH resolution but it is possible to change by Function settings F2 Set this function according to the application some countries the resolution will be limited NORMAL only and the setting F2 is not available In the COUNTING mode the scale works as in the HIGHER resolution regardless _ of weight display resolution Determines a unit weight the weigh how many pieces on the weighing pan using the unit weight 1 Press the MODE switch to select pcs 3 pcs pieces i ZERO LI 2 Press and hold the switch to enter ron the sample unit weight storing mode ZERO 4 LI 3 To select the number of samples press the
14. V DC Maximum current 100mA DC Maximum ON resistance 35 20 n 11 MAINTENANCE 11 1 Notes on maintenance Do not disassemble the scale Contact your local A amp D dealer if your scale needs service or repair LJ Please use the original packaging for transportation Do not use organic solvents to clean the scale Use a warm lint free cloth dampened with a mild detergent 11 2 Error codes Overload error Range over notice j L Unit weight error zr Low battery I LTI L LILI Low power Memory writing error Warning to indicate that an object beyond the scale capacity has been placed on the pan Remove the object from the pan This will be shown if the weight sensor receives strong force upward Check if the weighing pan is touching anything or if there is anything in the base There is a possibility that the weight sensor itself may have a failure The sample weight is too light to set the unit weight in the counting mode Increase the sample numbers Warning to show that the batteries are exhausted Replace them with new baiteries Warning to show that the voltage of main power source is too low This may be shown that the scale fails to store parameters when the calibration function setting unit weight registration comparator limits setting and so on have been done Turn the power off once and try the above procedure again If this error happens again there
15. WM PD4000966 AM UST IS ro Be 9 ILL gt f eee N kooo ooo N memes 0 EIE uem A UA eui ef p P HIDE ei INSTRUCTION MANUAL Digital Platform Scales FG 150KAL 150 150 FG 60KAL FG 60KAM 60 30 30 A amp D Company Limited 4 This manual and Marks All safety messages are identified by the following WARNING or CAUTION of _ ANSI 2535 4 American National Standard Institute Product Safety Signs and Labels The meanings are as follows A potentially hazardous situation which if not avoided could result in death or serious injury A potentially hazardous situation which if not avoided may result in minor or moderate injury AN WARNING AN CAUTION This is a hazard alert mark ds This mark informs you about the operation of the product u This manual is subject to change without notice at any time to improve the product Product specifications are subject to change without any obligation on the part of the manufacturer 2004 A amp D Company Limited All rights reserved Contents T INTRODUCTHO
16. ed F6 1 To compare all data F6 2 To compare more than 44 or less than 4d F6 3 To compare all stable data F6 4 To compare stable data more than 44 or less than 4d F6 5 To compare stable data more than 44 __ d minimum weight display see 12 1 Specifications In case of counting mode d is equal to minimum weight display of kg mode Q The upper limit and lower limit numerical values are common to each of the weighing and counting mode Ignore the decimal point of setting value to apply it to each mode Example of FG30K setting value is 001000 Display mode NORMAL resolution 10 00 30 00 kg x 0 01 ka HIGH resolution HIGHER resolution kg 1 000kg 30 000 kgx0 002kg NORMAL resolution Ib HIGH resolution Ib HIGHER resolution Ib Counting mode 1000pcs 7 7 Entering the upper and lower limit values 1 Press the MODE switch to select weighing unit kg Ib or 7 2 Press and hold the MODE switch to enter the upper limit setting mode 3 Enter an upper limit value using the following switches RE ZERO ZERO select the digit blinking to change PRINT Increment the value of the selected digit The minus sign can be set at the next digit of the least significant digit The PRINT switch alternates the minus sign on and off The blinking shows minus and no sign is plus 4 After setting all of digits p
17. es all stable data display division Filtering to weighing data F RS 232C SB Reaction to the Data format B except command command Factory setting E TT tul Luj uj EN c 5 RS 232C Data output mode CD mM cn C3 Comparator mode nm enr en c tu lt t c a 1 CO 10 OPTIONS The following options are available for the FG series 23 FG 23 RS 232C serial interface OP 24 FG 24 RS 232C serial interface and Comparator relay output 23 and OP 24 cannot be used together 10 1 Installation of 23 24 The OP 23 OP 24 has an interface board an option panel and a DIN 8 pin connector The option panel and DIN connector are common to both options Before installation prepare an interface cable using attached DIN connector Or is a way to use the optional RS 232C cable see 10 2 23 RS 232C serie interface 1 Disconnect the AC adapter from the scale 2 Remove the four screws and the cover of option slot 3 Thread the interface cable through the hole of option panel first and connect to DIN connector to the interface board Connect the interface board to the connector in the display pod 5 Attach and fix the o
18. or setting parameters 1 Turn the power off 2 Press and hold the ZERO switch and turn the power on via the ON OFF switch Then the first function item and its parameter is displayed 3 Set the parameter value using the PRINT switch Ll If you do not need to change the parameter go to next Step without setting 4 Press the MODE switch Then the display goes to the next function item LJ In this stage the new parameter is not stored the scale yet To end changing the parameters turn the power off 5 Repeat the steps 3 and 4 to the last item 6 After setting the last item press the MODE switch Then will appear 7 Press the MODE switch again The parameters are stored in the scale and the scale will automatically boot up LI If you turn the power before this step is done none of the parameters will be changed 14 9 2 Function list ______ Auto power off disabled Automatically use onl and AC adapter Normal 1 3 000 class Legal for trade will be Normal 28222 1U S A models only 1 Auto power off function IL N Ti Display resolution wT CI LU 1 CI Weighing unit E when powered on RS 232C Baud rate Conditions to A Compares data gt 40 lt 4d d minimum Compar
19. ption panel using the screws that removed in the step 2 Interface cable 16 lal 18 10 2 23 RS 232C serial interface This interface allows FG series to be connected with a multi function printer or a personal computer The 5 232 interface has the following four modes stream mode Outputs data continuously Command mode Controls the scale using commands from a computer Print switch mode Outputs data by pressing the switch Auto print mode Outputs data which meets the conditions of auto print LJ If necessary set the parameter of the data format and data output mode F4 F5 and F8 A DIN 8 pin connector 586 is provided with the OP 23 for wiring There are optional cables to connect with a personal computer 577 200 FG to D Sub 25 computer RS 232C cable 2m AX KO1786 200 FG to D Sub 9 pin computer RS 232C cable 2m 577 200 1786 200 DIN 7 D Sub 25 _ DIN 7P D Sub 9S 1 1 1 1 3 queam posee 3 3 4 4 4 4 5 5 5 5 en 7 7 7 7 others E 8 9 DIN 7 pin plug P can connect with DIN 8 pin socket Interface specifications Transmission system EIA RS 232C Transmission form Asynchronous bi directional half duplex Data format Baud rate 2400 4800 9600 bps Data 7 bits parity 1bit even otart bit 1 bit Stop bit 1 bit Code IMP Terminator Le OAh 1 15V 5V 0 5V 15V s
20. ress the MODE switch Then the upper limit is stored and the display goes to the lower setting mode 5 Set the lower limit in a similar way and press the MODE switch to return to weighing mode E The upper and lower limits are maintained even if the scale is powered off 11 8 CALIBRATION This function adjusts the scale for accurate weighing Calibrate the scale in the following cases When the scale is first used E When the scale has bee moved H cw When the ambient environment has Connecto changed For regular calibration seres net an ma Loose the lock screws on the rear side of ACalibration CAL switch the display pod and remove the CAL switch cover Then there is a calibration CAL switch cover switch on the board inside O For the FG KB series without column you may once remove the weighing pan to access lock screws easily 2 Do not use a ballpoint pen and so on to press the calibration switch That may short circuit and damage the scale 22 E 8 1 Calibration using a weight 1 Warm up the scale for at least half an hour with nothing on the weighing pan Change Function setting F1 or place something on the pan to disable the autc power off function 2 Press and hold the calibration CAL switch until appears and release the switch 5 Hi O The weighing unit must be kg or
21. rks as TARE for U S A models The metric models cannot accept this command Reply to the command When the F8 0 is selected the scale reacts io the received command as follows D For the command the scale will send the data C For the Z and commands the scale will send the same code as a reply executing the command Reply Reply When the command cannot execute because the scale is unstable for exampl P will be sent Reply If the received command is not for the FG series ihe scale will send command for the metric model is included to this group Reply When F8 1 is selected there is no reply except the Q command 10 3 24 RS 232C serial interface and Comparator relay outpu The 24 has RS 232C series interface and relay output for the compara function It allows output of the OK or LO signal results to an external device solid state relay output The specification for the RS 232C interface is same as the OP 23 FG 23 amp See 40 2 OP 23 RS 232C serial interface for further information Interface specifications Pin connections l l View from outside i 50 RXD GND AM DSR Mating connector DIN 8 58 m Attached to FG 24 OK HI LO l i Inside of OP 24 Maximum rating for relay is as follows Maximum voltage 50
22. s first used or has been moved to different place it should be calibrated using a calibration weight But if a calibration weight is not available the gravity acceleration correction will compensate the scale Change the gravity acceleration value of the scale to the value of area where the scale will be used Refer to the gravity acceleration map appended to the end of this manual LJ Note 7 it is not necessary to set the gravity acceleration correction when calibrating the scale with a calibration weight at the place where it is to be used 1 Press and hold the calibration CAL switch until DB appears and release the switch H L The weighing unit must be kg or Ib to enter calibration mode 2 Press the PRINT switch The display shows the gravity acceleration value memorized in the scale 3 To change the displayed value using the following switches 7 ZERO select the digit blinking to change PRINT Increment the value of the selected digit 4 Press the MODE switch The display returns to 5 If necessary to calibrate the scale using a calibration weight go to step 3 of 8 1 Calibration using a weight To finish the setting turn the power off 13 The scale has Function settings to expand your applications The parameters set in the Function settings are maintained even if the power switcher off 9 1 The procedure f
23. tomatically set to zero power on zero _PRINT Switch Outputs the weight value to printer In the setting mode this switch is used to increment the value of the selected digit blinking _MODE Switch MODE Switches the weighing unit In the setting mode this switch is used to store a parameter and go to the next 0 7 RE ZERO _RE ZERO Switch Clears the display to zero In the setting mode this switch is used to select a digit blinking to change its value ZERO Switch U S A model Zeroes the scale and turns the display zero In the setting mode this switch is used to select a digit blinking to change its value _TARE Switch U S A model Subtracts tare container weight on the weighing pan The RE ZERO ZERO and switches work when the weight value is stable The RE ZERO and ZERO switches will zero the scale if the weight is within 2 of the weighing capacity kg around the zero point The ZERO indicator turns on If the weight exceeds 2 of the weighing capacity kg the RE ZERO switch will tare the scale In this case the ZERO and NET indicators turn on The TARE switch will tare the scale when the weight is plus value In this case the ZERO and NET indicators turn on The ZERO operation clears tare operation previously done and NET indicator turns off 4 SETTING UP 4 1 Attaching a display pod to the base FG KAL and F
24. top bit Parity bit Data bit Start bit 17 MM MM to Pin connections Mating connector DIN 8 pin 58 Attached to FG 23 _ Data format View from outside 0 RXD GND sd TXD DSR NC NC NC r NC Inside of OP 23 HERES TE Header Cr Le Data Unit Terminator Separator shows a space There are 4 types of headers ST Stable weighing data QT Stable counting data US Unstable weighing data including counting data OL Out of weighing range Over The data is normally 9 digits including decimal point and a sign There 4 types of units Weighing data gram _ Counting data pcs Weighing data decimal pound oz Weighing data decimal ounce The terminator is always Cale Example of output data Weighing data kg Counting data Out of range kg Out of range pcs S T err 11 1121314151 1 1 98 83 9 8 1 17 6 leal 18 Data output mode Stream mode Function setting F5 0 The scale outputs the current display data The data update rate is approximately 10 times per second This rate is the same as the display update The scale does not output data while it is in setting mode Print switch mode Function setting