Home

3Com X3 Owner's Manual

image

Contents

1. P2 Valet Switch D E Optional Wiring Diagrams Red White Wire When programmed for 2nd Unlock Output When Programmed for this function the Red White wire provides a second unlock output to unlock the passenger s doors Use the Blue Wire on the Black 3 pin connector to unlock the drivers door Unlock Driver s Door First for 3 Wire Negative Door Lock Systems Green Wire Blue Wire oo _ 87 Red White Wire cH F i 12V 85 H 86 ALA984H 3 Relay Lock Driver s Door op g Passenger s Switch i Unlock Lock Tuniock T B To 12V or Ground Door Lock Relay To 12V or Ground if Driver s Door Unlock Wire les Control Module T Passenger s Door E 2 4 Optional Wiring Diagrams Red White Wire When programmed for Domelight Supervision Output When Programmed for this function the Red White wire provides a output to turn on the vehicles interior light when the alarm has been disarmed The domelight will stay on for 30 seconds unless the ignition key is on Output to Dome Light or Red White Wire To Constant 12 Volts SPST ALA984H Relay Not Supplied Input to Relay or Brown Wire When programmed for Horn Output When Programmed for this function the Brown wire provides a output t
2. 2 90 seconds after the system has been triggered A The siren will still be sounding and the parking light flashing and B The starter disable will activate to prevent the vehicle from being restarted C It will remain active until the vehicle s battery power is exhausted L Anti Car Jacking Automatic Activation Warning 1 If you don t need this alarm system s car jacking function to be On set it to Off The default car jacking setting is Off see Feature No 6 on programming chart Warning 2 When this feature is programmed for Automatic Mode operation the car jacking feature is armed at all times when the ignition key is on Opening any protected entrance while the vehicle s ignition is On will trigger the car jacking system The parking lights will turn on for 1 5 seconds to indicate car jacking is activated 1 60 seconds after the system has been triggered the siren starts alarming and the parking lights start flashing 90 seconds after the system has been triggered A The siren will still be sounding and the parking light flashing and B The starter disable will activate to prevent the vehicle from being restarted C It will remain active until the vehicle s battery power is exhausted N Override the System to Turn Off Car Jacking Turn the ignition switch from Off to On and within 10 seconds push valet switch the siren will stop and the system will disarm Copyri
3. Connect the white wire to the parking light wire coming from the headlight switch Do not connect the white wire to the dashboard lighting dimmer switch Damage to the dimmer will result Use a volt meter to test the connection point before connecting the white wire While checking rotate the dimmer switch to make sure you do not have the dimmer lead The limitation of the white wire is 10 Amp max Do not exceed this limit or damage to the alarm and parking light relay will result Headlight Switch Piggyback Connection Parking Lights Only White Wire ZIM ZIN S55 Wiring continued HC3 Black 3 Pin Door Lock Harness Blue Wire Door Unlock Control J Connect the Blue wire to the unlock wire from the door lock switch If the door locking system is not a trigger system additional relays will be required Green Wire Door Lock Control Connect the Green wire to the lock wire from the door lock switch f the door locking system is not a trigger system additional relays will be required 3 Wire Ground Trigger Door Lock System Green Wire Connect to Lock Lock Control Blue Wire Connect to Unlock 3 Switch Black 3 Pin Lock Out s Mini Connector Ground Input N To Door Lock z Control Relays lt Unlock Out J P1 LED Status Indicator
4. Installation and Owner s Manual Model X3 For Technical Assistance please call 800 638 3600 or visit www magnadyne com This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment Table of Contents Componentinstallation s 6 es jea de sacs a aoe ane fans nec arentomintgg dpa aGhaynded neal Rie a eae Bede ae na gad aa 2 Wiring White 12 Pin Main Harness sii cscheeeivea dias seen d sed eekadeten secede dayton kee aan 2 5 Wiring Harness Quick Reference 0 00 c cece ete ene 3 Black 3 Pin DOOr Lock Harness eeyca iekac 2 pontine gad acndiee pe bbe hide o e eden gate 6 Optional Wiring SUGGESTIONS s r goes aekies weg weal tide abe ea Hone ese ideea a oa 5 6 Programming the TranSMtlels cs ccc eo pep Sere Geaanges tesa weed Gea N hes Aveda ARENE 6 7 Alarm Feature ProgrammMing 5 2 sacccarccodede ciavaseeebsadiudaegdeasadeserdeveteaaw Yeas 7 8 Shock Sensor Testing and AdjUStMent 25 cnnteniotdgatictadpetsdioddsseuesdidad nese anes 9 QWNERSIMANU Al 25255 boca E E E EE E E EEEE E I EEE EET 9 12 C
5. Lock 3 5 Sec Door Lock 8 Sec Double Unlock Output Unlock Output Unlock Output 6 6 Car Jacking Off Manual Car Jack On Automatic Car Jack On 7 7 HC4 Red White Wire HC4 Red White Wire HC4 Red White Wire Channel 3 Output Domelight Output 2nd Unlock Output 8 8 Trunk Release Trunk Release Disarm On Disarm Off Keyless Entry 9 9 Alarm Keyless Only Mode Entry Mode No Alarm Functions No Carjacking Functions 10 10 HC4 Brown Wire HC4 Brown Wire HC4 Brown Wire Siren Output Pulsed Siren Output Horn Output ai 11 Instant Door Door Ajar Warning Ajar Warning with 45 Second Delay 12 12 Standard Horn SOS Type 4 chirp S S S L Pulse Output S S S L L L S S S S L S L 5 chirp S M L S M L 6 chirp SS L S S Step 4 Exit Program Mode mode 5X 1X Hold Turn On the Ignition 3 long chirps will confirm exit of the programming Note Waiting 15 seconds after the last command will also cause the system to automatically exit the programming mode Turn the ignition switch from the OFF position to the ON position 3 times leaving it in the Off position the third time Before 15 seconds has passed push and release the valet switch 6 times Hold the button down on the 6th press until 3 short chirp beeps and 1 long chirp beep is heard then release it Press and release the x button for 2 seconds You will hear 1 long siren horn chirp You are now in the Primary Trigger Sh
6. d the door is closed for example the entrance will reset the door input trigger within 3 seconds J Progressive Car Finder Use your remote control to locate your vehicle in a crowded parking lot or structure Note The alarm system must be armed for more than 30 seconds before the car finder feature will operate A Press the LOCK button on the transmitter The siren or horn will blast two times and then blast again two more times The parking lights will flash three times with each blast B Press the LOCK button on the transmitter again within 30 seconds The siren or horn will blast three times and then blast again three more times The parking lights will flash three times with each blast C Press the LOCK button on the transmitter again within 30 seconds The siren or horn will blast six times The parking lights will flash six times with each blast K Anti Car Jacking Manual Activation Warning If you don t need this alarm system s car jacking function to be On set it to Off The default car jacking setting is Off see Feature No 6 on programming chart Pressing and holding the Lock and Unlock button on the transmitter for 1 second while the vehicle s ignition is On will trigger the car jacking The parking lights will turn on for 1 5 seconds to indicate car jacking is activated 1 60 seconds after the system has been triggered the siren starts alarming and the parking lights start flashing
7. ght 2008 2009 Magnadyne Corporation X3 IMUM 7 24 08 Rev A
8. gramming to change the setting Output to Power Trunk Switch ore 87 Red White Wire i To Constant 12 Volts SPST ALA984H 86 30 85 z Relay Not Supplied gt Input to Relay or Black Wire Chassis Ground This is main ground connection of the alarm module Make this connection to a solid section of the vehicle chassis Do not connect this wire to any existing ground wires supplied by the factory wire loom make the connection to the vehicle s chassis directly Vacant Socket No Connection Brown Wire Siren Output Connect the brown wire to the Negative wire from an electronic siren Siren Supplied Connect t the remaining wire from the siren to 12 volt Battery The Brown wire can also be programmed for horn honk output See Alarm Feature Programming to change the setting White Red Wire Parking Light Relay Input The white red wire is the input to the flashing parking light relay The connection of the white red wire will determine the output polarity of the flashing parking light relay Connect the white red wire to battery to have output from the relay or connect the white red wire to chassis ground to have ground output from the relay Red Wire 12VDC Battery Input Connect the Red wire directly to the battery post for best operation of the alarm system White Wire Parking Light Relay Output
9. l make the programming process much easier to perform D 3X 3X With the ignition switch in the OFF position turn the Within 10 seconds push and release the valet switch 3 key On Off times The siren horn will emit 1 long chirp or beep Push and release the valet switch 3 more times The siren horn will emit 1 long chirp or beep You are now in Alarm Feature Programming mode 1 Press the valet switch the number of times required to access the feature that needs adjusting 2 Press the indicated transmitter button and listen for the chirp sequence to set the a feature Example Complete steps 1 2 and 3 to enter feature program mode Push the valet switch 2 times Selects Manual Automatic arm programming the siren will chirp 2 times and the LED will flash 2 times Change the feature to Automatic Arming by Pressing the a button on the transmitter The siren horn will chirp 2 times Alarm Feature Programming continued Press Press TX Button f Press TX Button Press TX Button R Press TX Button LED Flash Valet Chi One Chirp i P Switch irp Default Setting Two Chirps Three Chirps 1 1 Chirps On Chirps Off M l Armi Automatic Arming Automatic Arming 2 2 anual Arming without Door Locking with Door Locks 3 3 Ignition On Off with Ignition On Off without Door Lock Unlock Door Lock Unlock 4 4 Auto Rearm Off Auto Rearm On 5 5 8 Sec Door
10. larm function are bypassed however the remote panic feature and remote door locks will remain operational Enter Valet Mode 1 Turn the ignition to the On position 2 Push and hold valet switch for 2 seconds until the LED turns on The LED will remain on as long as the system is in the Valet Mode Exit Valet Mode 1 Return to normal operation turn ignition On 2 Push and hold the valet switch for 2 seconds the LED will turn off to indicate the system is exiting the valet mode H Panic Function The transmitter can be used as a remote panic switch to manually trigger the alarm in case of emergency 1 Press and hold the Star button on the transmitter for 3 seconds The alarm will immediately sound 2 To stop the panic alarm press and release any button on the transmitter the panic mode will be turned off immediately 3 If the button is not pressed the panic alarm will automatically stop after 60 seconds 1 60 Second Rearming If your security system has become triggered the siren will sound for 60 seconds and then stop and reset to a fully armed condition Note If the alarm system has been triggered from the following inputs Trunk Shock sensor Ignition key on or Door open and an input remains in a triggered state a door left open for example your security system will remain triggered for three 60 second cycles then it will fully rearm and excluding the input that triggered it When the excluded trigger is correcte
11. ns ui for 1 Second Activate Car Jacking Ignition Key Must be On Press and Hold for Panic Mode On Press and Mold Tor seconds Press and Release for Panic Mode Off Press and Release Activate 2nd System operation C Dual Zone Shock Sensor 1 Light impacts to the vehicle will cause a pre warning warn away chirp from the siren or horn These light impacts will not set the alarm into full trigger even if they are repetitive 2 Hard impacts to the vehicle will bypass the pre warning indicator and activate a full alarm trigger D Manual Arming Lock 1 Press the Lock button on the transmitter 2 The siren will chirp once and the parking light will flash once indicating that the system is now armed The vehicle s doors will lock upon arming if door lock control has been installed Silent Arming Disarming Press the Lock and Unlock button together on the transmitter to arm or disarm you security system No chirp sound will be heard arm disarm confirmation will be through the vehicles parking lights only E Automatic Arming This X3 security system is equipped with an optional Automatic Arming feature which allows the security system to arm 30 seconds after the last door is closed Operation 1 Turn the ignition to the Off position and exit the vehicle 2 After all entrances are closed the security system s LED will flash fast for 30 seconds If you reopen any protected entrance the securi
12. o use the vehicles horn as the primary sounding device Locate the horn button wire at the base of the steering column Note Some vehicles will require an additional relay To Horn neee L Fuse D L _ 87 Brown Wire 87a To 12V Ft SP 86 85 12V or Ground Depending 430 on System Requirements Programming the Transmitter Programming the Remote Transmitter Note This mode will only retain the last 4 remote transmitters programmed If the transmitter memory is exceeded the security system will start deleting transmitters from memory in chronological order 3X With the ignition switch in the OFF position turn the Before 15 seconds has passed push and release the valet key On switch 3 times THe siren will emit 1 long 1 short chirp You are now in Transmitter Programming mode Programming the Transmitter Step 5 Exit Program Mode Press the Lock button on the first Repeat for each additional When finished turn Off the ignition transmitter until you hear a transmitter key or wait for 15 seconds to get out confirmation chirp beep The of transmitter programming mode transmitter is now coded into the You will hear 3 long chirps beeps system You are out of the transmitter programming mode Alarm Feature Programming Examine the feature chart enclosed and decide which feature will get changed Circling the feature to be changed wil
13. ock Sensor Test mode Shock Sensor Testing and Adjustment Increase Decrease 1 Press the LOCK button to 1 Press and hold the LOCK and To exit the shock sensor test mode increase sensitivity by 1 step UNLOCK buttons together for 2 turn ignition On and 3 long chirps 1 chirp seconds You will hear 2 long will confirm exit of the Shock 2 Press the UNLOCK button to siren horn chirp You are now in the Sensor test mode decrease the sensitivity by 1 step Pre warning trigger Shock Sensor Note 30 seconds of inactivity will 1 chirp test mode force exit of the shock sensor test 3 Rap on the vehicle body panels 2 Follow the procedures in Step 4 to mode and glass to achieve the proper adjust the Pre warning sensitivity setting Note If you hear 2 chirps while making an adjustment you have reached the max setting Owners Manual D A Transmitter Operation B Alarm Status Indicators LED Indications LED is off Alarm is disarmed LED is flashing normal Alarm is armed LED is flashing fast Automatic Arming Countdown Un Lock LED is on solid Valet Mode Disarm LED flashes twice then pauses Tamper warning alarm was triggered by an open trunk or hood LED flashes three times then pauses Tamper warning alarm was triggered by an open door LED flashes four times then pauses Tamper warning alarm was triggered by ond he shock sensor System LED flashes five times then pause
14. omponent Installation Mounting the Control Module Find a suitable location to secure the alarm control module within the passenger s compartment of the vehicle Never mount the alarm control module in the engine compartment or in the trunk In addition never mount the alarm control module in the direct path of the heater Secure the alarm control module by using wire ties or drill two 1 8 holes and secure the module to the frame of the vehicle with the screws provided Valet Switch Select a mounting location for the switch that is easily accessible to the driver of the vehicle The switch does not have to be concealed However concealing the switch is always recommended as this provides an even higher level of security to the vehicle Mount the valet switch in a hidden but accessible location Route the valet switch wires to the control module LED Status Indicator The LED status indicator should be mounted in a highly visible area Leave at least 6mm of space behind the mounting location for LED housing Once a suitable location is chosen drill a 1 4 hole Run the LED wires through the hole then press the 2 pin LED housing into the place Route the LED wires to the control module Antenna Wire For maximum possible range keep the antenna wire away from the alarm harnesses Stretch out the antenna in another direction and keep it as straight as possible Do not connect the antenna wire to ground Do not lengthen or shorten the antenna wire Do no
15. round when Armed Output D Red White 300mA Programmable Channel 3 Trunk Output LC Black Chassis Ground Brown Siren Output D White Red Parking Light Relay Input 12VDC Battery Input L White Parking Light Relay Output 3 HC3 3 Pin Door Lock Harness Blue Unlock D Wiring continued Violet Wire Common Door Pin Input The violet wire connects to the common wire of the vehicle that switches on the dome light Normally this wire is located at one of the door jamb switches For some vehicles it may be necessary to connect the violet wire directly to the switched turn on wire at the dome light The violet wire connects to positive switched circuits only Orange Wire Ground when Armed Output The orange wire is typically connected to an optional starter disable relay as shown SPDT 30A Relay Not Supplied Orange Wire eet Ground when Armed Alarm Output Starter Wiring continued Red White Wire 300mA Programmable Channel 3 Output Default Trunk Release The Red White wire is typically used to release the power trunk by remote An additional relay is usually required as shown in the diagram below This wire can also be programmed for Domelight Supervision Control or 2nd unlock function See Alarm Feature Pro
16. s Tamper warning alarm was triggered by voltage from the ignition switch turning on Lock Arm Car Finder Chirp Indications One siren chirp Security system is armed Panic wo siren chirps Security is disarmed Four chirps Tamper disarm warning alarm was previously triggered wo sets of two chirps Stage 1 of progressive car finder wo sets of three chirps Stage 2 of progressive car finder Six chirps Stage 3 of progressive car finder CH 3 Trunk Parking Light Indications Parking lights flash one time upon arming Security system is armed Parking lights flash two times upon disarming Security system is disarmed Parking lights flash three times upon disarming Tamper disarm warning alarm was previously triggered Parking lights flash three times while armed Stage 1 and 2 of progressive car inder Parking lights flash six times while armed Stage 3 of progressive car finder Owners Manual Continues Button Function Transmitter Button Action System Function Remark Press and Release Arm Lock Doors Press Twice Arm Lock Doors Delete Shock Sensor 2nd Long Beep Press and Release Progressive Car Finder Functions 30 Seconds After Armed Press and Release Disarm Un Lock Doors Press and Hold for 1 5 Seconds Channel 3 Activation Release Trunk as Default Press Both Buttons Together Silent Arm Disarm Ignition Key is Off Press and Hold Both Butto
17. t coil or wind the antenna wire around another harness Wiring HC4 White 12 Pin Main Harness The main wire harness contains 11 wires which all have a specific purpose Follow the wiring recommendations enclosed for each wire Wires not used should be released from the harness connector or taped off to prevent accidental shorting Yellow Wire 12VDC Ignition Input Connect the Yellow wire to a 12 volt wire that is switched on and off by the ignition key The correct wire will indicate 12 volts when the ignition key is in the on and start positions Do not connect the yellow wire to the ACC wire coming from the ignition switch Green Wire Common Door Pin Input The green wire connects to the common wire of the vehicle that switches on the dome light Normally this wire is located at one of the door jamb switches For some vehicles it may be necessary to connect the green wire directly to the switched turn on wire at the dome light The green wire connects to negative switched circuits only Blue Wire Hood Trunk Auxiliary Trigger Input The blue wire is an instant grounding trigger input for optional hood trunk grounded pin switches or any electronic sensor Wiring Harness Quick Reference HC4 12 Pin Main Harness C Yellow 12VDC Ignition Input D C Green Common Door Pin Input Blue Hood Trunk Auxiliary Trigger Input gt m Violet Common Door Pin Input Orange G
18. ty system LED will stop flashing It will begin flashing again once all the protected vehicle s entrances are closed 3 After the 30 second timer has elapsed the security system will automatically Arm The siren will chirp one time and the parking lights will flash one time Passive Door Locking If the Automatic Arming with Door Locks feature has been programmed on The vehicle doors will automatically lock after the automatic arming cycle has been completed see Feature No 2 on programming chart Owners Manual continued F Manual Disarming Unlock 1 Press the Unlock button on the transmitter 2 The siren will chirp twice and parking lights will flash twice indicating that the security system is now disarmed The vehicle doors will unlock disarming when interfaced with the security system Tamper Disarming If alarm is triggered upon disarming the system the siren chips 4 times and the parking lights flash 3 times Automatic Rearm see feature No 5 on programming chart If this feature is selected the security system will automatically rearm itself 60 seconds after disarming with remote transmitter Automatic rearm will cancel if any door is opened before the 60 seconds timer has elapsed G Valet Mode The valet switch allows you to temporarily bypass all alarm functions eliminating the need to give your transmitter to parking attendants or garage mechanics When the system is in valet mode all a

Download Pdf Manuals

image

Related Search

Related Contents

GST200-2/1 Intelligent Fire Alarm Control Panel  Aluratek AUV100F  Powermate P2201 Portable Generator User Manual  取扱説明書 (PDF 9.31MB)  Manual WS 19 - Polar Audio  Huawei Ascend G700 White  Whirlpool Refrigerator MFI226AE User's Manual  WSTIMS for WINDOWS  TV-IP851WIC    

Copyright © All rights reserved.
Failed to retrieve file