Home

Lenovo eServer xSeries x3550 M5

image

Contents

1. Part Feature Description Maximum number code supported 2 5 inch hot swap 12 Gbps SAS HDDs 00NA221 ASBB 300GB 15K 12Gbps SAS 2 5 G3HS 512e HDD 12 00NA241 ASBF 600GB 10K 12Gbps SAS 2 5 G3HS 512e HDD 12 00NA231 ASBD 600GB 15K 12Gbps SAS 2 5 G3HS 512e HDD 12 00NA251 ASBH 900GB 10K 12Gbps SAS 2 5 G3HS 512e HDD 12 00NA261 ASBK 1 2TB 10K 12Gbps SAS 2 5 G3HS 512e HDD 12 00NA271 ASBM 1 8TB 10K 12Gbps SAS 2 5 G3HS 512e HDD 12 2 5 inch hot swap 12 Gbps SAS SEDs 00NA281 ASBP 300GB 15K 12Gbps SAS 2 5 G3HS 512e SED 12 00NA291 ASBR 600GB 10K 12Gbps SAS 2 5 G3HS 512e SED 12 00NA286 ASBQ 600GB 15K 12Gbps SAS 2 5 G3HS 512e SED 12 00NA296 ASBS 900GB 10K 12Gbps SAS 2 5 G3HS 512e SED 12 00NA301 ASBT 1 2TB 10K 12Gbps SAS 2 5 G3HS 512e SED 12 00NA306 ASBU 1 8TB 10K 12Gbps SAS 2 5 G3HS 512e SED 12 2 5 inch hot swap 12 Gbps SAS Hybrid drives 00NA311 ASBV 300GB 15K 12Gbps SAS 2 5 G3HS 512e Hybrid 12 00NA321 ASBX 600GB 15K 12Gbps SAS 2 5 G3HS 512e Hybrid 12 2 5 inch hot swap 12 Gbps SAS Enterprise SSDs 00FN379 AS7C 200GB 12G SAS 2 5 MLC G3HS Enterprise SSD 12 OOFN389 AS7E 400GB 12G SAS 2 5 MLC G3HS Enterprise SSD 12 OOFN399 AS7G 800GB 12G SAS 2 5 MLC G3HS Enterprise SSD 12 OOFN409 AS7J 1 6TB 12G SAS 2 5 MLC G3HS Enterprise SSD 12
2. Part Feature Maximum Standard models number code Description supported where used 00KA094 5 System 550W High Efficiency Platinum AC 2 A2x B2x C2x C4x Power Supply D2x F2x G2x H2x 00 096 5 System x 750W High Efficiency Platinum AC 2 62x J2x N2x P2x Power Supply Q2x N2x P2x Q2x 00KA097 ASAZ System x 750W High Efficiency Titanium AC 2 L2x Power Supply 200 240V 00 098 A5BO System x 900W High Efficiency Platinum AC 2 M2x Power Supply 00MV212 ASPR System x 900W High Efficiency 48 V DC Power 2 Supply 00MV211 ASPQ System x 1500W High Efficiency Platinum AC 2 Power Supply General power supply rules are as follows e Minimum of one and maximum of two power supplies per system e If two are installed power supplies must be identical Important It is highly recommended to validate server configuration for specific power requirements using the latest version of the System x Power Configurator http www ibm com systems bladecenter resources powerconfig html This will ensure that the right power supply is chosen for optimal performance System x3550 M5 36 A hot swap power supply option ships standard with one 2 8 10A 100 250V 320 C13 to IEC 320 C 14 rack power cable Other country specific and rack cables can be ordered if needed see the following table Table 19 Power cables
3. Memory options System x3550 M5 supports TruDDR4 Memory TruDDR Memory uses the highest quality components sourced from Tier 1 DRAM suppliers and only memory that meets our strict requirements is selected It is compatibility tested and tuned on every System x server to maximize performance and reliability TruDDR4 Memory will have a unique signature programmed into the DIMM which will enable System x servers to verify whether the memory installed is qualified supported Because TruDDR4 Memory is authenticated certain extended memory performance features can be enabled to extend performance over industry standards From a service and support standpoint System x memory automatically assumes the system s warranty and service and support provided worldwide The server supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are installed Each processor has four memory channels and there are three DIMMs per channel The following rules apply when selecting the memory configuration e server supports RDIMMs and LRDIMMs e Mixing different types of memory RDIMMs and LRDIMMs is not supported e The maximum quantity of DIMMs that can be installed in the server depends on the number of processors e DIMMs in the server operate at the same speed which is determined as the lowest value of the following speeds e Memory speed that is supported by the specific processor e Low
4. 2 4 Optional 1x 750 35MB 2133MHz 145W 2133MHz 2GB Flash HS 8 bay HS 2 Models announced September 2014 5463 A2x 1x E5 2603 v3 6C 1 6GHz 1x 8GB M1215 4x 2 5 Open 4x GbE 2 4 Optional 1x 550 W 15 1600MHz 85W 2133MHz 55 8 HS 2 5463 2 1x 5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 3 5 Open 4 2 4 Optional 1 550 15 1600MHz 85W 2133MHz SS 4 bay HS 2 5463 C2x 1x E5 2620 v3 6C 2 4GHz 1x 16GB M1215 4x 2 5 Open 4 2 4 Optional 1 550 15 1866MHz 85W 2133MHz HS 8 bay HS 2 5463 4 1x E5 2620 v3 6C 2 4GHz 1x 16GB M1215 4x 3 5 Open 4xGbE 2 4 Optional 1x 550 W 15MB 1866MHz 85W 2133MHz HS 4 bay HS 2 5463 D2x 1x E5 2630 v3 8C 2 4GHz 1x 16GB M5210 4x 2 5 Open 4x GbE 2 4 Optional 1x 550 W 20MB 1866MHz 85W 2133MHz 1GB Flash 5 8 bay HS 2 5463 H2x 1x E5 2630L v3 8C 1 8GHz 1x 16GB M5210 4x 2 5 Open 4x GbE 2 4 Optional 1x 550 W 20MB 1866MHz 55W 2133MHz 1GB Flash 5 8 bay HS 2 5463 F2x 1x E5 2640 v3 8C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4x GbE 2 4 Optional 1x 550 W 20MB 1866MHz 90W 2133MHz 1GB Flash 5 8 bay HS 2 5463 G2x 1x E5 2650 v3 10C 2 3GHz 1x 16GB M5210 10x 2 5 Open 4x GbE 2 4 None 1x 550 W 25MB 2133MHz 105W 2133MHz 1GB Flash HS 12 bay HS 2 5463 62x 1x E5 2670 v3 12C 2 3GHz 1x 16GB M5210 4x 2 5 Open 4x GbE 2 4 Optional 1x 750 W 30MB 2133MHz 120W 2133MHz 2GB Flash HS 8 bay HS 2 5463 J2x 1x E5 2680 v3 12C
5. 00KA070 5 ASBV Intel Xeon Processor E5 2603 v3 6C 1 6GHz 15MB Cache 1600MHz 85W A2x 00MU566 ASL6 ASLF Intel Xeon Processor E5 2608L v3 6C 2 0GHz 15MB Cache 1866MHz 52W 00 071 A5BG ABBW Intel Xeon Processor E5 2609 v3 6C 1 9GHz 15MB Cache 1600MHz 85W B2x 00MU567 ASL7 ASLG Intel Xeon Processor E5 2618L v3 8C 2 3GHz 20MB Cache 1866MHz 75W 00KA067 5 ASBS Intel Xeon Processor 5 2620 v3 6C 2 4GHz 15 Cache 1866MHz 85W C2x 4 00 0407 ASCT ASD4 Intel Xeon Processor E5 2623 v3 4C 3 0GHz 10MB Cache 1866MHz 105W 00MU568 ASL8 ASLH Intel Xeon Processor E5 2628L v3 10C 2 0GHz 25MB Cache 1866MHz 75W 00 068 ASBD 5 Intel Xeon Processor E5 2630 v3 8C 2 4GHz 20MB Cache 1866MHz 85W D2x 00KA077 ASBN 5 2 Intel Xeon Processor E5 2630L v3 8C 1 8GHz 20 Cache 1866MHz 55W H2x 00 0408 ASCU 505 Intel Xeon Processor E5 2637 v3 4C 3 5GHz 15MB Cache 2133MHz 135W 00KA069 ASBE ASBU Intel Xeon Processor E5 2640 v3 8C 2 6GHz 20MB Cache 1866MHz 90W 00MUA409 ASCV ASD6 Intel Xeon Processor E5 2643 v3 6C 3 4GHz 20MB Cache 2133MHz 135W 00MU569 ASL9 ASLJ Intel Xeon Processor E5 2648L v3 12C 1 8GHz 30MB Cache 2133MHz 75W 00KA072 ASBH 5 Intel Xeon Processor 5 2650 v3 10 2 3GHz 25MB Cache 2133MHz 105W G2x 00 0406 ASCS 503 In
6. Part Feature Description number code Rack power cables 39Y7932 6263 4 3m 10A 100 250V C13 to IEC 320 C14 Rack Power Cable 39Y7937 6201 1 5m 10A 100 250V C13 to IEC 320 C14 Rack Power Cable 39Y7938 6204 IEC309 C20 to C13 rack jumper cable Country specific power cords 39Y7917 6212 European 10A line C13 to CEE 7 7 2 8M 39Y7918 6213 Denmark 10A line C13 to DK2 5A 2 8M 39Y7919 6216 Switzerland 10A line C13 to SEV 1011 2 8M 39Y7920 6218 Israel 10A line C13 to SI 32 2 8M 39Y7921 6217 Italy 10A line C13 to CEE 7 7 2 8M 39Y7922 6214 South Africa 10A line C13 to SABS 164 1 2 8M 39Y7923 6215 United Kingdom 10A line C13 to BS 1363 2 8M 39Y7924 6211 Australia NZ 10A line C13 to SAA AS C112 2 8M 39Y7925 6219 Korea 7A line C13 to 15A 250V 2 8M 39Y7927 6269 India 6A line C13 to Fig 68 2 8M 39Y7928 6210 China 6A line C13 to GB 2099 1 2 8M 39Y7929 6223 Brazil 10A line C13 to NBR 6147 2 8M 39Y7930 6222 Argentina 10A line C13 to IRAM 2063 2 8M 39Y7931 6207 Power Cable C13 NEMA 5 15P 14ft 00CG265 5 Power Cord Taiwan AC plug 10A 250V 2 8M 00CG267 5 Power Cord Taiwan AC plug 15A 125V 2 8M 46M2592 A1RF 10A 250V C13 to NEMA 6 15P 2 8m line cord 46M2593 A1RE Japan 10A 100V C13 to JIS C 8303 2 8m line cord
7. 2 5 inch hot swap 12 Gbps SAS SED Enterprise SSDs 00 419 AS7L 400GB SED 12G SAS 2 5 MLC G3HS Enterprise SSD 12 O0FN424 AS7M 800GB SED 12G SAS 2 5 MLC G3HS Enterprise SSD 12 System x3550 M5 23 Table 10 Drive options for internal disk storage Part 2 Part Feature Description Maximum number code supported 2 5 inch simple swap 12 Gbps SAS Enterprise SSDs O0FN384 AS7D 200GB 12G SAS 2 5 MLC G3SS Enterprise SSD 8 O0FN394 AS7F 400GB 12G SAS 2 5 MLC G3SS Enterprise SSD 8 00 404 AS7H 800GB 12G SAS 2 5 MLC G3SS Enterprise SSD 8 00 414 AS7K 1 6TB 12G SAS 2 5 MLC G3SS Enterprise SSD 8 2 5 inch hot swap 6 Gbps SAS HDDs 00AJ096 A4TL 300GB 10K 6Gbps SAS 2 5 G3HS HDD 12 00AJ081 A4TR 300GB 15K 6Gbps SAS 2 5 G3HS HDD 12 00AJ091 4 600GB 10K 6Gbps SAS 2 5 G3HS HDD 12 00AJ126 A4TS 600GB 15K 6Gbps SAS 2 5 G3HS HDD 12 00AJ071 4 900GB 10K 6Gbps SAS 2 5 G3HS HDD 12 00AJ146 A4TP 1 2TB 10K 6Gbps SAS 2 5 G3HS HDD 12 2 5 inch hot swap 6 Gbps NL SAS HDDs 00AJ121 4 500GB 7 2 6Gbps NL SAS 2 5 G3HS HDD 12 00AJ086 A4TU 1TB 7 2K 6Gbps NL SAS 2 5 G3HS HDD 12 2 5 inch hot swap 6 Gbps NL SATA HDDs 00AJ136 A4TW 500GB 7 2K 6Gbps NL SATA 2 5 G3HS HDD 12 00AJ141 4 1TB
8. 2 maximum RDIMMs bays NIC slots drive supply std std max max TopSeller United States Canada 5463 NAU 1x E5 2603 v3 6C 1 6GHz 1x 8GB M1215 4x 2 5 Open 4xGbE 2 4 Optional 1x 550 W 15 1600MHz 85W 2133MHz HS 8 bay HS 2 5463 NBU 1x E5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 3 5 Open 4xGbE 2 4 Optional 1x 550 W 15 1600MHz 85W 2133MHz HS 4 bay HS 2 5463 NCU 1x E5 2620 v3 6C 2 4GHz 1x 16GB M1215 4x 3 5 Open 4xGbE 2 4 Optional 1x 550 W 15 1866MHz 85W 2133MHz HS 4 bay HS 2 5463 NDU 1x E5 2630 v3 8C 2 4GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 550 W 20MB 1866MHz 85W 2133MHz HS 8 bay HS 2 5463 NMU 2x E5 2640 v3 8C 2 6GHz 2x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 2x 750 W 20MB 1866MHz 90W 2133MHz HS 8 bay HS 2 5463 NJU 1x E5 2643 v3 6C 3 4GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 900 W 20MB 2133MHz 135W 2133MHz HS 8 bay HS 2 5463 NEU 1x E5 2670 v3 12C 2 3GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 750 W 30MB 2133MHz 120W 2133MHz HS 8 bay HS 2 5463 NNU 2x E5 2670 v3 12C 2 3GHz 4x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 2x 900 W 30MB 2133MHz 120W 2133MHz HS 8 bay HS 2 5463 NFU 1x E5 2680 v3 12C 2 5GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 900 W 30MB 2133MHz 120W 2133MHz HS 8 bay HS 2 5463 NHU 1x E5 2690 v3 12C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 900 W 30MB 2133MHz 135W 2133MHz
9. 48 V DC power supplies Hot swap parts Hard drives power supplies and fans Systems management Unified Extensible Firmware Interface UEFI Integrated Management Module II IMM2 1 based on Renesas SH7758 Predictive Failure Analysis light path diagnostics Automatic Server Restart ToolsCenter IBM Systems Director and Active Energy Manager and Intel Node Manager Optional Advanced Management Module Advanced Upgrade for remote presence graphics keyboard and mouse virtual media Security features Power on password administrator s password two Trusted Platform Modules TPMs on the IMM2 TPM 1 2 and on the host TPM 1 2 2 0 Optional lockable front bezel Video Matrox G200eR2 with 16 MB memory integrated into the IMM2 Maximum resolution is 1600x1200 at 75 Hz with 16 M colors Operating Microsoft Windows Server 2012 R2 2012 and 2008 R2 Red Hat Enterprise Linux 6 and 7 Systems SUSE Linux Enterprise Server 11 VMware vSphere ESXi 5 1 and 5 5 supported Limited warranty Three year customer replaceable unit and onsite limited warranty with 9x5 Next Business Day NBD Service and Optional service upgrades are available through the ServicePac 4 hour or 2 hour response support time 8 hours fix time one year or two year warranty extension remote technical support for System x hardware and selected System x and third party Microsoft Linux VMware
10. 00FN128 ASVF 3TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 49 6002 A3W9 4TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 00FN143 A5VH 4TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN158 A5VK 5TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN173 A5VM 6TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 3 5 inch simple swap 6 Gbps NL SATA HDDs 81Y9810 A22W 2TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 00FN118 A5VE 2TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 81Y9814 A22N 3TB 7 2K 6Gbps NL SATA 3 5 0256 HDD 4 00FN133 A5VG 3TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 49Y6012 A3WA _ 4TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 O0FN148 4 7 2 6Gbps NL SATA 3 5 G2SS 512e HDD 4 00 163 A5VL 5 7 2K 6Gbps NL SATA 3 5 255 512e HDD 4 00FN178 A5VN 6TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 System x3550 M5 26 Table 10 Drive options for internal disk storage Part 5 Part Feature Description Maximum number code supported 3 5 inch hot swap 6 Gbps SAS Enterprise SSDs 00AJ480 A56G 3700 200GB SATA 3 5 MLC HS Enterprise SSD 4 00AJ485 A56H 53700 400GB SATA 3 5 MLC HS Enterprise SSD 4 00AJ490 A56J 53700 800GB SATA 3 5 MLC HS Enterprise SSD 4 3 5 inch hot swap 6 Gbps SATA Enterprise Value SSDs 00AJ435 A57F 120GB SATA 3 5 MLC HS Enterprise Value SSD 4 00AJ440 A57G 240GB SATA 3 5
11. 2U Rack UPS 100V 120V 53951KX 1500VA LCD 2U Rack UPS 230V 53952AX 2200VA LCD 2U Rack UPS 100V 120V 53952KX 2200VA LCD 2U Rack UPS 230V 53953AX 3000VA LCD 3U Rack UPS 100 V 120 V 53953JX 3000VA LCD 3U Rack UPS 200 V 208 V 53956AX 6000VA LCD 40 Rack UPS 200 V 208 V 53956KX 6000VA LCD 4U Rack UPS 230 V 53959KX 11000VA LCD 5U Rack UPS 200V 208V 230V For more information see the list of Product Guides in the Power infrastructure category http lenovopress com systemx power System x3550 M5 51 Power distribution units The server supports attachments to the power distribution units PDUs listed in the following table Table 34 Power distribution units part 1 Part number Description Switched and Monitored PDUs 46M4002 1U 9 C19 3 C13 Active Energy Manager DPI PDU 46M4003 1U 9 C19 3 C13 Active Energy Manager 60A 3 Phase PDU 46M4004 1U 12 C13 Active Energy Manager DPI PDU 46M4005 1U 12 C13 Active Energy Manager 60A 3 Phase PDU 46M4167 1U 9 C19 3 C13 Switched and Monitored 30A 3 Phase PDU 46M4116 00 24 C13 Switched and Monitored 30A PDU 46M4119 OU 24 C13 Switched and Monitored 32A PDU 46M4134 OU 12 C19 12 C13 Switched and Monitored 50A 3 Phase PDU 46M4137 OU 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ult
12. 4x 2 5 2x 4xGbE 474 Multi 1x 550 W 15 1600MHz 85W 2133MHz 1GB Flash HS 8 300GB burner HS 2 10K 5463 1x 5 2620 v3 6C 2 4GHz 2x 8GB M1215 4x 3 5 Open 4xGbE 4 4 Multi 1x 550 W 15 1866MHz 85W 2133MHz 55 4 burner HS 2 5463 EJM 1x E5 2620 v3 6C 2 4GHz 2x 8GB M5210 4x 2 5 2x 4 GbE 4 4 Multi 1x 750 W 15 1866MHz 85W 2133MHz 1GB Flash HS 8 300GB burner HS 2 10K 5463 EKM 1x 5 2630 v3 8C 2 4GHz 2x 8GB M5210 4x 2 5 Open 4xGbE 4 4 Multi 1x 750 W 20MB 1866MHz 85W 2133MHz 1GB Flash HS 8 bay burner HS 2 5463 ELM 2x E5 2650 v3 10C 2 3GHz 2x 16GB M5210 8x 2 5 Open 4xGbE 4 4 Multi 2x 750 W 25MB 2133MHz 105W 2133MHz HS 8 bay burner HS 2 Express Japan 5463 E5J 1x E5 2603 v3 6C 1 6GHz 1x 8GB M5210 4x 2 5 Open 4xGbE 4 4 Optional 1x 550 W 15 1600MHz 85W 2133 28 1GB Flash 5 8 bay HS 2 5463 E6J 1x E5 2609 v3 6C 1 9GHz 1x 8GB M5210 4x 2 5 Open 4xGbE 4 4 Optional 1x 550 W 15 1600MHz 85W 2133 28 1GB Flash 5 8 bay HS 2 5463 E7J 1x E5 2620 v3 6C 2 4GHz 1x 8GB M5210 4x 2 5 Open 4xGbE 4 4 Optional 1x 550 W 15 1866MHz 85W 2133 28 1GB Flash HS 8 bay HS 2 Express Europe Middle East and Africa 5463 E1G 1x E5 2603 v3 6C 1 6GHz 1x 8GB M1215 4x 2 5 Open 4xGbE 2 4 Multi 1x 550 W 15 1600MHz 85W 2133MHz HS 8 bay burner HS 2 5463 E2G 1x E5 2620 v3 6C 2 4GHz 1x 8GB M5210 8x 2 5
13. Gateway 6000 00AK142 4 4 UM KVM Module VGA SD Dual RJ45 For more information see the list of Product Guides in the Rack cabinets and options category http lenovopress com systemx rack System x3550 M5 55 Lenovo Financial Services Lenovo Financial Services reinforces Lenovo s commitment to deliver pioneering products and services that are recognized for their quality excellence and trustworthiness Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today protect against technology obsolescence and preserve your capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy to do business with us Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service Our systems processes and flexible policies support our goal of providing customers with a positive experience We finance your entire solution Unlike others we allow you to bundle everything you need from hardware and software to service contracts installati
14. MLC HS Enterprise Value SSD 4 00 352 50 240GB SATA 3 5 MLC HS Entry 550 4 00AJ445 A57H 480GB SATA 3 5 MLC HS Enterprise Value SSD 4 00FN357 ASOL 480GB SATA 3 5 MLC HS Entry SSD 4 00AJ450 57 800GB SATA 3 5 HS Enterprise Value SSD 4 00 362 50 960GB SATA 3 5 MLC HS Entry 550 4 System x3550 M5 27 Internal backup units The x3550 M5 server does not support internal tape drive options or other internal backup units However it can be attached to the external tape drives using SAS or Fibre Channel connectivity see Table 31 Optical drives The x3550 M5 server supports the optical drive options listed in the following table Server models with ten 2 5 inch drive bays on the front do not support an internal optical drive a supported external optical drive can be used instead Table 11 Optical drives Standard Part Feature Maximum models where number code Description supported used 00 066 A5KG Ultraslim 9 5mm SATA DVD ROM 1 00 067 A5KH Ultraslim 9 5mm SATA Multi Burner 1 Ultraslim 9 5mm SATA DVD ROM part number 00 066 supports the following media and speeds for reading CD ROM 24 CD DA DAE 24 CD R 24X CD RW 24X DVD ROM 8X DVD R 8X DVD R 8X DVD R DL 6X DVD R DL 8X DVD RW 8X DVD RW 8X DVD RAM 4 7 GB 5X Ultraslim 9 5mm SATA Multi Burner part number 00 067 supports the same media and speeds for
15. System x3550 M5 37 Integrated virtualization The server supports VMware ESXi installed on a USB memory key or one or two SD cards in the SD Media Adapter for System x The USB memory key is installed in a USB socket inside the server The SD Media Adapter is installed in a dedicated slot inside the server When only one SD card is installed in the SD Media Adapter you can create up to 16 volumes each of which is presented to UEFI as a bootable device When two SD Media cards are inserted volumes can be mirrored RAID 1 across both cards up to a total of eight mirrored volumes The use of mirrored volumes improves system availability because the server remains operational even if one SD card fails The RAID functionality is handled internally by the SD Media Adapter The following table lists the virtualization option Table 20 Virtualization option Part Feature Description Maximum number code supported USB memory key 00ML233 ASN6 USB Memory Key for VMware ESXi 5 1 Update 2 1 00 1 235 ASN7 USB Memory Key for VMware ESXi 5 5 Update 2 1 41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 1 SD Media Adapter and SD cards OOML706 A5TJ SD Media Adapter Option 00ML706 includes 2 blank 32GB SD cards 1 00ML700 AS2V Blank SD Media for System x 2 None AS4B RAID Adapter for SD Media w VMware ESXi 5 1 U2 2 SD Media 1 RAlDed None AS4C
16. depending on the riser cards installed The slots are as follows e Slot 1 PCle 3 0 x16 or ML2 low profile half length not present if the HDD Rear Kit is installed e Slot 2 PCle 3 0 x16 or PCle 3 0 x8 low profile or full height half length PCle 3 0 x16 slot requires the second processor to be installed not present if the HDD Rear Kit is installed e Slot 3 PCle 3 0 x16 or PCle 3 0 x8 low profile half length e Slot 4 PCle 3 0 x8 dedicated for an internal RAID controller System x3550 M5 Table 1 Standard specifications part 2 Components Specification Ports e Front 1x USB 2 0 8x 2 5 drive bay models or 2x USB 2 01 4x 3 5 and 10x 2 5 drive bay models 1x USB 3 0 and 1x DB 15 video e Rear 2x USB 3 0 1x USB 2 0 1x DB 15 video 1x RJ 45 systems management 4x RJ 45 GbE network ports Optional 1x DB 9 serial port e Internal 1x USB port for embedded hypervisor e Internal 1x SD Media Adapter slot for embedded hypervisor Cooling Calibrated Vectored Cooling with up to eight redundant hot swap fans six standard additional two with the second processor or with the x3550 M5 Thermal Solution Kit dual fan zones with 1 fan redundancy each fan has two motors Power supply Up to two redundant hot swap 550 W 750 W 900 W or 1500 W High Efficiency Platinum AC power supplies or 750 W High Efficiency Titanium AC power supplies or 900 W High Efficiency
17. for self encrypting drives SEDs with MegaRAID SafeStore with RAID 5 upgrade Fixed stripe size of 64 KB The ServeRAID M5210 SAS SATA Controller has the following specifications Eight internal 12 Gbps SAS SATA ports Up to 12 Gbps throughput per port Two x4 HD mini SAS internal connectors SFF 8643 Supports connections to SAS SATA HDDs and SSDs and SAS Expanders Supports RAID 0 1 and 10 Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5200 Series RAID 6 upgrade Optional support for self encrypting drives SEDs with MegaRAID SafeStore with RAID 5 upgrade Supports 1 GB non backed cache or 1 GB 2 GB or 4 GB flash backed cache PCle 3 0 x8 host interface Based on the LSI SAS3108 12 Gbps ROC controller The N2215 SAS SATA HBA has the following specifications Eight internal 12 Gbps SAS SATA ports Up to 12 Gbps throughput per port Two x4 HD mini SAS internal connectors SFF 8643 Supports connections to SAS SATA HDDs and SSDs Optimized for SSD performance No RAID support PCIe 3 0 x8 host interface Based on the LSI SAS3008 12 Gbps controller For more information see the list of Product Guides in the RAID adapters category http lenovopress com systemx raid System x3550 M5 22 Internal drive options The following table lists hard drive options for internal disk storage of the x3550 M5 server Table 10 Drive options for internal disk storage Part 1
18. in specific environments and is presented as an illustration The result obtained in other operating environments may vary Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Any references in this publication to non Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this Lenovo product and use of those Web sites is at your own risk Any performance data contained herein was determined in a controlled environment Therefore the result obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurements may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment Copyright Lenovo 2014 2015 All rights reserved System x3550 M5 58 This document was created updated on May 13 2015 Send us your comments in one of the following ways e Use the online Contact us review form found at ibm com redbooks e Send your comments in an e mail to redbooks us ibm com This document is available online at http lenovopress com tips1194 T
19. up to 23 bits per pixel regardless of the system state e Remotely accessing the server using the keyboard and mouse from a remote client e Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server e Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive The blue screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating system hang condition A system administrator can use the blue screen capture to assist in determining the cause of the hang condition The following table lists the remote management option Table 21 Remote management option Part Feature Description Maximum number code supported 90Y3901 Integrated Management Module Advanced Upgrade 1 System x3550 M5 39 All standard models ship with basic light path diagnostics which include the system LEDs on the front of the server See Figure 2 and the LEDs near the monitored components for example the DIMM error LED on the system board Standard models with 2 5 inch drive bays and the basic light path can be upgraded to a next gen light path LCD display panel The LCD display enables you to have quick access to system status firmware network and health information Configure to order CTO customers
20. 10GbE SFP VFA for System 3 00Y5624 A3MT Qlogic 8200 VFA FCoE iSCSI License for System x FoD 3 Features on Demand upgrade for 90Y4600 one for each adapter 4709952 A47H Solarflare SFN5162F 2x10GbE SFP Performant Adapter 3 System x3550 M5 32 Table 14 Network adapters Part 2 Part Feature Description Maximum number code supported 1 Gb Ethernet PCle 42C1780 2995 Broadcom NetXtreme 2xGbE BaseT Adapter 3 90Y9370 A2V4 Broadcom NetXtreme Dual Port GbE Adapter for System x 3 90Y9352 A2V3 Broadcom NetXtreme Quad Port GbE Adapter for System x 3 00AG510 A56L Intel 1350 2 2xGbE BaseT Adapter for System x 3 00AG520 A56M Intel 1350 4 4xGbE BaseT Adapter for System x 3 SFP and QSFP based adapters require supported transceivers or DAC cables that must be purchased separately For more information see the list of Product Guides in the Networking adapters category http lenovopress com systemx networkadapters System x3550 M5 33 Storage host bus adapters The following table lists storage HBAs supported by the x3550 M5 server Table 15 Storage adapters Part Featur
21. 10x2 5 inch SAS SATA hot swap drive bay server models that can be upgraded to 12x 2 5 inch SAS SATA hot swap drive bays 10x front drive bays and 2x rear drive bays 3 4x2 5 inch SATA Simple Swap drive bay server models that can be upgraded to 8x 2 5 inch SATA Simple Swap drive bays 4x 3 5 inch SAS SATA hot swap drive bay server models 4x 3 5 inch SATA Simple Swap drive bay server models The following figure shows some of these configurations 4x 3 5 inch drive bays 8x 2 5 inch drive bays 10x 2 5 inch drive bays Figure 5 Internal drive configurations Optical drive support Four and eight drive bay models of the x3550 M5 support an optional internal optical drive System x3550 M5 The following table shows the internal storage options available the 3550 M5 server Table 7 Internal storage options Part Feature Description Maximum Standard models number code supported where used Base drive kits None A59W System x3550 M5 4x 2 5 HS HDD Kit 1 62x C2x D2x F2x H2x J2x L2x M2x N2x P2x Q2x None A5A4 System x3550 M5 4x 3 5 HS HDD Kit 1 4 None A5A0 System x3550 M5 10x 2 5 HS HDD Kit 1 G2x None 59 System x3550 5 4x 2 5 SS HDD Kit Non Raid 1 None 5 5 System 3550 5 4x 3 5 SS HDD Kit Non Raid 1 None A5A6 System x3550 M5 4x 2 5 SS HDD Kit HW RAID 1 A2x None System x3550 5 4 3 5 SS HDD Kit HW RAI
22. 1x System x3550 M5 4x 2 5 HS HDD Kit FC e 1 215 A59W 8 e 1 M1215 or Factory installed e 1x M5210 or e 1x System x3550 M5 4x 2 5 HS HDD Kit FC e 1x N2215 A59W and e 1x System x3550 M5 4x 2 5 HS HDD Kit PLUS FC A59X Field upgrade for the 4 drive bay model e 1x System x3550 M5 4x 2 5 HS HDD Kit PLUS PN 00KA055 10 e 1 1215 Factory installed e 1x M5210 or e 1x System x3550 M5 10x 2 5 HS HDD Kit FC e 1 215 5 0 12 e 1 M1215 or Factory installed e 1x M5210 or e 1x System x3550 M5 10x 2 5 HS HDD Kit FC e 1 215 A5A0 and e 1x System x3550 M5 2x 2 5 HS HDD Rear Kit FC A5A2 Field upgrade for the 10 drive bay model e 1x System x3550 M5 2x 2 5 HS HDD Rear Kit PN 00KAO058 System x3550 M5 Table 8 Internal storage configurations FC Feature Code PN Part Number qty quantity Part 2 Swap 6 Gbps SATA no RAID support Drive bay Drive bay type qty Storage controller Drive kits required 2 5 inch SATA Simple 4 e Integrated 8 port Factory installed Swap 6 Gbps SATA e 1x System x3550 M5 4x 2 5 SS HDD Kit no RAID support Non Raid FC A59Y e 1 1215 Factory installed e 1 5210 or e 1x System x3550 M5 4x 2 5 SS HDD Kit HW e 1xN2215 RAID FC A5A6 8 e Integrated 8 port Factory installed 6 Gbps SATA e 1x System x3550 M5 4x 2 5 SS HDD Kit no RAID support Non Raid FC A59Y and e 1x System x3550 M5 4x 2 5
23. 2 5GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 750 W 30MB 2133MHz 120W 2133MHz 2GB Flash HS 8 bay HS 2 5463 L2x 1x E5 2690 v3 12C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 750 W 30MB 2133MHz 135W 2133MHz HS 8 bay HS 2 5463 M2x 1x E5 2699 v3 18C 2 3GHz 1x 16GB M5210 4x 2 5 Open 4 2 4 Optional 1 900 W 45MB 2133MHz 145W 2133MHz HS 8 bay HS 2 xin the Machine Type Model MTM represents a country specific letter for example the EMEA MTM is 5463 A2G and the US MTM is 5463 A2U Ask a Lenovo representative for specifics T Processor detail Processor quantity and model cores core speed L3 cache memory speed and thermal design power TD P 8 For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options Refer to the Specifications section for information about standard features of the server System x3 550 M5 Express and TopSeller models The following table lists the Express and TopSeller models of the x3550 5 Table 3 Express and TopSeller models Part 1 MTM Intel Xeon processort Memory RAID Drive Drives Onboard I O Optical Power
24. 50 Hz or 60 Hz 10 3A e 200 to 240 nominal V ac 50 Hz or 60 Hz 5 0A e Input kilovolt amperes approximately e Minimum configuration 0 14 e Maximum configuration 1 194 Models with 750 W Platinum AC power supplies e 100to 127 nominal V ac 50 Hz or 60 Hz 8 6A e 200to 240 nominal V ac 50 Hz or 60 Hz 4 2 A e Input kilovolt amperes approximately e Minimum configuration 0 14 kVA e Maximum configuration 1 015 kVA Models with 750 W Titanium AC power supplies e 200 to 240 nominal V ac 50 Hz or 60 Hz 4 2A e Input kilovolt amperes approximately e Minimum configuration 0 14 e Maximum configuration 0 965 kVA Models with 550 W AC power supplies e 100to 127 nominal V ac 50 Hz or 60 Hz 6 5A e 200to 240 nominal V ac 50 Hz or 60 Hz 3 3 e Input kilovolt amperes kVA approximately e Minimum configuration 0 14 e Maximum configuration 0 732 kVA e Models with 48Vdc 900 W power supplies e 48 60 nominal V dc 25 8A e Input kilovolt amperes kVA approximately e Minimum configuration 0 14 e Maximum configuration 1 237 kVA e BTU output e Minimum configuration 461 Btu hr 135 watts e Maximum configuration 6667 Btu hr 1954 watts e Noise level e 6 6 bels operating e 64 bels idle System x3550 M5 42 Warranty options The System x3550 M5 has a three year warranty with 24x7 standard call center support a
25. 5210 4x 2 5 Open 4xGbE 4 4 Multi 2x 550 W 15 1866MHz 85W 2133MHz 1GB Flash 55 8 bay burner HS 2 5463 EOU 1x E5 2620 v3 6C 2 4GHz 1x 8GB M5210 4x 3 5 Open 4xGbE 4 4 Multi 2x 550 W 15 1866MHz 85W 2133MHz 1GB Flash SS 4 bay burner HS 2 5463 EPU 1x E5 2640 v3 8C 2 6GHz 2x 16GB M5210 4x 2 5 Open 4xGbE 4 4 Multi 2x 550 W 20MB 1866MHz 90W 2133MHz 1GB Flash HS 8 bay burner HS 2 5463 EQU 2x E5 2680 v3 12C 2 5GHz 2x 16GB M5210 8x 2 5 Open 4xGbE 4 4 Multi 2x 750 W 30MB 2133MHz 120W 2133MHz 2GB Flash HS 8 bay burner HS 2 Processor detail Processor quantity and model cores core speed L3 cache memory speed TDP For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options System x3550 M5 11 Table 3 Express and TopSeller models Part 4 MTM Intel Xeon processort Memory RAID Drive Drives Onboard I O Optical Power 2 maximum RDIMMs bays NIC slots drive supply std std max max Express Asia Pacific Australia and New Zealand only 5463 EGM 1x E5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 3 5 Open 4xGbE 4 4 Multi 1x 550 W 15 1600MHz 85W 2133MHz 55 4 burner HS 2 5463 EHM 1x E5 2609 v3 6C 1 9GHz 1x 8GB M5210
26. 6C 2 4GHz 1x 16GB M1215 4x 2 5 2x 4xGbE 2 4 Optional 2x 550 W 15MB 1866MHz 85W 2133MHz HS 8 300GB HS 2 10K 5463 E8U 1x E5 2620 v3 6C 2 4GHz 1x 16GB M1215 4x 2 5 2x 4x GbE 4 4 Optional 2x 750 W 15 1866MHz 85W 2133MHz HS 8 300GB HS 2 10K 5463 EVU 1x E5 2620 v3 6C 2 4GHz 1x 16GB M1215 4x 3 5 2x2TB 4x GbE 2 4 Optional 2x 550 W 15MB 1866MHz 85W 2133MHz HS 4 7 2K HS 2 5463 EUU 1x E5 2640 v3 8C 2 6GHz 1x 16GB M1215 4x 2 5 2x 4x GbE 2 4 Optional 2x 550 W 20MB 1866MHz 90W 2133MHz HS 8 300GB HS 2 10K 5463 E9U 1x E5 2640 v3 8C 2 6GHz 1x 16GB M5210 4x 2 5 2x 4xGbE 4 4 Optional 2x 750 20MB 1866MHz 90W 2133MHz 1GBFlash HS 8 300GB HS 2 10K 5463 EW 1x E5 2640 v3 8 2 6GHz 1x 16GB M1215 4x 3 5 2x2TB 4x GbE 2 4 Optional 2x 550 W U 20MB 1866MHz 90W 2133MHz HS 4 7 2K HS 2 T Processor detail Processor quantity and model cores core speed L3 cache memory speed TDP 8 For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options System x3550 M5 10 Table 3 Express and TopSeller models Part 3 MTM Intel Xeon processort Memory RAID Drive Drives Onboard I O Optical Power 2 maximum RDIMMs
27. 6C9114 A45W ServeRAID M1215 SAS SATA Controller 1 A2x B2x C2x C4x 47C8675 A3YY N2215 SAS SATA HBA 1 Hardware upgrades for the M5210 47C8656 A3Z0 ServeRAID M5200 Series 1GB Cache RAID 5 Upgrade 1 47C8660 A3Z1 ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade 1 D2x F2x G2x H2x 47C8664 A3Z2 ServeRAID M5200 Series 2GB Flash RAID 5 Upgrade 1 62x J2x N2x P2x Q2x 47C8668 A3Z3 ServeRAID M5200 Series 4GB Flash RAID 5 Upgrade 1 Features on Demand upgrades for the M5210 47C8708 A3Z6 ServeRAID M5200 Series Zero Cache RAID 5 Upgrade 1 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator 1 47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler 1 Features on Demand upgrades for the M1215 00AE930 5 5 ServeRAID 1200 Zero Cache RAID 5 Upgrade for FOD Requires cache memory upgrade 47C8656 47C8660 47C8664 or 47C8668 System x3550 M5 21 The ServeRAID M1215 SAS SATA Controller has the following specifications Eight internal 12 Gbps SAS SATA ports Up to 12 Gbps throughput per port Two internal mini SAS HD connectors SFF 8643 Supports connections to SAS SATA HDDs and SSDs LSI SAS3008 12 Gbps RAID on Chip ROC controller Support for RAID levels 0 1 and 10 standard support for RAID 5 50 with optional FoD upgrade Zero Controller Cache no battery flash backup Optional support
28. 7 2K 6Gbps NL SATA 2 5 G3HS HDD 12 2 5 inch simple swap 6 Gbps NL SATA HDDs 00NA597 ASLC 500GB 7 2K 6Gbps NL SATA 2 5 G3SS HDD 8 00NA622 ASLD 1TB 7 2K 6Gbps NL SATA 2 5 G3SS HDD 8 System x3550 M5 24 Table 10 Drive options for internal disk storage Part 3 Part Feature Description Maximum number code supported 2 5 inch hot swap 6 Gbps SAS Enterprise SSDs 00AJ207 A4UA 200GB SAS 2 5 MLC G3HS Enterprise SSD 12 00AJ212 A4UB 400GB SAS 2 5 MLC G3HS Enterprise SSD 12 00AJ217 40 800GB SAS 2 5 MLC G3HS Enterprise SSD 12 00AJ222 A4UD 1 6TB SAS 2 5 MLC G3HS Enterprise SSD 12 2 5 inch hot swap 6 Gbps SAS Enterprise Capacity SSDs 00 671 ASW6 3 84TB 6Gb SAS Enterprise Capacity G3HS MLC SSD 10 2 5 inch hot swap 6 Gbps SATA Enterprise SSDs 00AJ156 A4U3 53700 200GB SATA 2 5 MLC G3HS Enterprise SSD 12 00AJ161 A4U4 53700 400GB SATA 2 5 MLC G3HS Enterprise SSD 12 00AJ166 A4U5 53700 800GB SATA 2 5 MLC G3HS Enterprise SSD 12 2 5 inch hot swap 6 Gbps SATA Enterprise Value SSDs 00AJ395 A577 120GB SATA 2 5 MLC G3HS Enterprise Value SSD 12 00AJ400 A578 240GB SATA 2 5 MLC G3HS Enterprise Value SSD 12 00FN337 AS0G 240GB SATA 2 5 MLC G3HS Entry SSD 12 00AJ405 A57
29. 9 480GB SATA 2 5 MLC G3HS Enterprise Value SSD 12 00 342 480GB SATA 2 5 MLC G3HS Entry SSD 12 00AJ410 A57A 800GB SATA 2 5 MLC G3HS Enterprise Value SSD 12 00FN347 50 960GB SATA 2 5 MLC G3HS Entry SSD 12 2 5 inch simple swap 6 Gbps SATA Enterprise Value SSDs 00 475 552 960GB SATA 2 5 MLC G3SS Entry 550 8 3 5 inch hot swap 12 Gbps NL SAS HDDs 00 188 A5VP 2TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e HDD 4 OOFN208 A5VQ 4 7 2K 12Gbps NL SAS 3 5 G2HS 512 HDD 4 00 228 A5VR 6TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e HDD 4 System x3550 M5 25 Table 10 Drive options for internal disk storage Part 4 Part Feature Description Maximum number code supported 3 5 inch hot swap 12 Gbps NL SAS SEDs O0FN238 A5VS 2TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 4 00 248 A5VT 4TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 4 00 258 A5VU 6TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 4 3 5 inch hot swap 6 Gbps NL SAS HDDs 90Y8572 A2U0 2TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 4 90Y8577 A2R2 3TB 7 2K 6Gbps NL SAS 3 5 G2HS HDD 4 3 5 inch hot swap 6 Gbps NL SATA HDDs 81Y9794 A22T 2TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 00FN113 A5VD 2TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 81Y9798 A22S 3TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4
30. D 1 B2x Upgrade drive kits require the base drive kit 00 058 2 System x3550 5 2 2 5 HS HDD Rear Kit 1 00 055 A59X System x3550 M5 4x 2 5 HS HDD Kit PLUS 1 00 056 592 System x3550 M5 4x 2 5 SS HDD Kit PLUS Non Raid 1 00KA060 A5A7 System x3550 M5 4 2 5 SS HDD Kit PLUS HW RAID 1 Available in standard or CTO models Available in CTO models only Base drive kits are always factory installed in either standard or custom CTO models Upgrade drive kits can be factory installed or can be installed as a field upgrade for supported standard or custom models HDD Rear Kit The HDD Rear Kit 00 058 is installed in place of the PCle slots 1 and 2 see the I O expansion options section and it includes a special riser that provides PCle 3 0 x16 slot 3 No other riser cards can be used when the HDD Rear Kit is installed 145 W processors cannot be used when the HDD Rear Kit is installed The HDD Rear Kit is connected to the SAS expander on the 10 drive backplane System x3550 M5 18 The following table lists possible internal storage configurations Table 8 Internal storage configurations FC Feature Code PN Part Number qty quantity Part 1 Drive bay Drive bay type qty Storage controller Drive kits required 2 5 inch SAS SATA 4 e 1 1215 Factory installed hot swap e 1x M5210 or e
31. Flex System 42U Rack For more information see the list of Product Guides in the Rack cabinets and options category http lenovopress com systemx rack System x3550 M5 Rack options The server supports the rack options listed in the following table Table 36 Rack options Part number Feature code Description Miscellaneous opt ions for the x3550 M5 00KA606 A5AK System x3550 M5 Slide Kit G4 included with the server 00KA607 A5AL System x Enterprise 1U Cable Management Arm CMA 00KA500 A5FW System Gen ll Universal Slides Kit 00KA162 Lockable Front Bezel Monitor kits and keyboard trays 17238BX 1723HC1 fc 1U 18 5 Standard Console 17238EX 1723HC1 fc A3EL 1U 18 5 Enhanced Media Console Console switches 1754D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager 1 8 Console cables 43V6147 3757 Single Cable USB Conversion Option UCO 39M2895 3756 USB Conversion Option 4 Pack UCO 46M5383 5341 Virtual Media Conversion Option Gen2 VCO2 46M5382 5340 Serial Conversion Option SCO Universal management gateway and cable 5 3858D3X 3858HC1 fc A4X1 Avocent Universal Management
32. HS 8 bay HS 2 5463 NPU 2x E5 2690 v3 12 2 6GHz 4x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 2x 900 W 30MB 2133MHz 135W 2133MHz HS 8 bay HS 2 5463 NKU 1x E5 2697 v3 14C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 900 W 35MB 2133MHz 145W 2133MHz HS 8 bay HS 2 TopSeller Europe Middle East and Africa 5463 NDG 1x 5 2630 v3 8C 2 4GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 550 W 20MB 1866MHz 85W 2133MHz HS 8 bay HS 2 5463 NEG 1x E5 2670 v3 12C 2 3GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 750 W 30MB 2133MHz 120W 2133MHz HS 8 bay HS 2 5463 NKG 1x E5 2697 v3 14C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 900 W 35MB 2133MHz 145W 2133MHz HS 8 bay HS 2 T Processor detail Processor quantity and model cores core speed L3 cache memory speed TDP 8 For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options System x3550 M5 Table 3 Express and TopSeller models Part 2 MTM Intel Xeon processort Memory RAID Drive Drives Onboard I O Optical Power 2 maximum RDIMMs bays NIC slots drive supply std std max max TopSeller Latin America Brazil only 5463 ETU 1x E5 2620 v3
33. Open 4xGbE 2 4 Multi 1x 550 W 15 1866MHz 85W 2133MHz 1GB Flash 5 8 bay burner HS 2 5463 E3G 1x E5 2630 v3 8C 2 4GHz 1x 8GB M5210 4x 2 5 Open 4xGbE 2 4 Multi 2x 550 W 20MB 1866MHz 85W 2133MHz 1GB Flash HS 8 bay burner HS 2 5463 E4G 1x E5 2640 v3 8C 2 6GHz 1x 16GB M5210 8x 2 5 Open 4xGbE 2 4 Multi 1x 550 W 20MB 1866MHz 90W 2133 28 1GB Flash HS 8 bay burner HS 2 T Processor detail Processor quantity and model cores core speed L3 cache memory speed TDP 8 For these models the standard DIMM is rated at 2133 MHz but operates at a lower speed to match the processor memory speed Actual memory speed maximums depend on several factors as described in Memory options Refer to the Specifications section for information about standard features of the server System x3550 M5 12 Processor options The x3550 M5 supports the processor options listed in the following table The server supports up to two processors This table shows which server models have each processor standard If there is no corresponding where used model for a particular processor this processor is only available through Configure to order CTO The processor part numbers include a CPU a heatsink and two system fans Table 4 Processor options Part number Feature codes Description Standard models where used
34. RAID Adapter for SD Media w VMware ESXi 5 5 U2 2 SD Media 1 RAlDed None ASCG RAID Adapter for SD Media w VMware ESXi 5 1 U2 1 SD Media 1 None ASCH RAID Adapter for SD Media w VMware ESXi 5 5 U2 1 SD Media 1 Option 00ML706 includes two 32GB SD cards however for CTO orders feature code A5TJ does not include SD media and the 32 GB cards and VMware vSphere preload must be selected separately CTO only System x3550 M5 38 Systems management The server contains Integrated Management Module II IMM2 1 which provides advanced service processor control monitoring and an alerting function If an environmental condition exceeds a threshold or if a system component fails the IMM lights LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem Optionally the IMM also provides a virtual presence capability for remote server management capabilities The IMM provides remote server management through industry standard interfaces Intelligent Plattorm Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue screen capture features The remote presence feature provides the following functions e Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with
35. RAID controllers and options Table 25 RAID controllers and options for external disk storage expansion Part number Feature code Description Maximum supported Standard models where used 12 Gb RAID controllers 00AE938 ASND ServeRAID M5225 2GB SAS SATA Controller Feature on Demand FoD upgrades for the M5225 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1 47C8710 A3Z7 ServeRAID M5200 Series Performance 1 Accelerator 47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler 1 System x3550 M5 45 The ServeRAID M5225 SAS SATA Controller has the following specifications Eight external 12 Gbps SAS SATA ports Supports 12 6 and 3 Gbps SAS and 6 and 3 Gbps SATA data transfer rates Two external x4 mini SAS HD connectors SFF 8644 Supports 2 GB flash backed cache standard Supports RAID levels 0 1 5 10 and 50 standard Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades PCle x8 Gen 3 host interface Based on the LSI SAS3108 12 Gbps ROC controller Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures For more information about the ServeRAID M5225 see the Lenovo Press Product Guide at http lenovopress com tips1258 The ServeRAID M5225 SAS SATA Controller supports connectivity to the external expansion enclosures l
36. SS HDD Kit PLUS Non Raid FC A59Z Field upgrade for the 4 drive bay model e 1x System x3550 M5 4x 2 5 SS HDD Kit PLUS Non Raid PN 00 056 e 1x M1215 or Factory installed e 1x M5210 or e 1x System x3550 M5 4x 2 5 SS HDD Kit HW e 1xN2215 RAID FC A5A6 and e 1x System x3550 M5 4x 2 5 SS HDD Kit PLUS HW RAID FC A5A7 Field upgrade for the 4 drive bay model e 1x System x3550 M5 4x 2 5 SS HDD Kit PLUS HW RAID PN 00 060 3 5 inch SAS SATA 4 e 1x M1215 or Factory installed hot swap e 1x M5210 or 1x System x3550 M5 4x 3 5 HS HDD Kit FC e 1xN2215 4 3 5 inch SATA Simple 4 e Integrated 8 port Factory installed e 1x System x3550 M5 4x 3 5 SS HDD Kit Non Raid FC A5A5 e 1 M1215 or 1 5210 e 1 N2215 Factory installed e 1x System x3550 M5 4x 3 5 SS HDD Kit HW RAID FC 5 8 System x3550 M5 20 Controllers for internal storage The following table lists the RAID controllers and the additional options used for the internal storage of the x3550 MB server The controllers are installed into a dedicated PCle slot Table 9 RAID controllers and HBAs for internal storage Part Feature Description Maximum Standard models number code supported where used 12 Gb SAS SATA controllers 46C9110 A3YZ ServeRAID M5210 SAS SATA Controller 1 62x D2x F2x G2x H2x J2x L2x M2x N2x P2x Q2x 4
37. X External USB 3 0 Dock with 500GB Cartridge 36251TY RDX External USB 3 0 Dock with 1TB Cartridge The external tape drives listed can be ordered through the System x sales channel The server might support other tape drives that are not listed in this table Refer to the IBM System Storage Interoperation Center for further information For more information see the list of Product Guides in the Backup units category http lenovopress com systemx tape System x3550 M5 49 Top of rack Ethernet switches The server supports the top of rack Ethernet switches listed in the following table Table 32 Top of rack switches Part number Description 1 Gb top of rack switches 7159BAX Lenovo RackSwitch G7028 Rear to Front 7159CAX Lenovo RackSwitch G7052 Rear to Front 715952F Lenovo RackSwitch G8052 Front to Rear 7159G52 Lenovo RackSwitch G8052 Rear to Front 10 Gb top of rack switches 7159BF7 Lenovo RackSwitch G8124E Front to Rear 7159BR6 Lenovo RackSwitch G8124E Rear to Front 715964F Lenovo RackSwitch G8264 Front to Rear 7159G64 Lenovo RackSwitch G8264 Rear to Front 7159DFX Lenovo RackSwitch G8264CS Front to Rear 7159DRX Lenovo RackSwitch G8264CS Rear to Front 7159CFV Lenovo RackSwitch G8272 Front to Rear 7159CRW Lenovo RackSwitch G8272 Rear to Front 7159GR5 Lenovo RackSwitch G8296 Fr
38. and eighth system fans needed for the following options when only one processor is installed e Intel X540 ML2 Dual Port 10GbaseT Adapter for System x e QLogic 8200 Dual Port 10GbE 5 VFA for System x The x3550 5 Thermal Kit is not needed if two processors are installed because the second processor includes these fans The COM Port Bracket part number 00KA161 is used for mounting the external serial port on the rear of the x3550 M5 This option includes the bracket and the cable The COM Port option is mounted in place of the PCIe slot and only PCle slots 1 and 2 remain available The following table lists the x3550 M5 Thermal Kit and COM Port Bracket part numbers Table 13 Miscellaneous options Part Feature Description Maximum number code supported 00 059 ASAJ System x3550 M5 Thermal Kit 1 00 161 A5AN COM Port Bracket 1 System x3550 M5 30 Network adapters The x3550 M5 supports four integrated Gigabit Ethernet ports The integrated network interface controller NIC has the following features A Broadcom BCM5719 chip Four Gigabit Ethernet ports NIC Teaming load balancing and failover Ethernet features Compliant with 1 Gb Ethernet IEEE 802 3 802 3u and 802 3ab PHY specifications Integrated PHY for 10 100 1000 Mbps for multispeed full and half duplex auto negotiation Automatic MDI crossover IEEE 802 3x compliant flow control s
39. ary and are available in select countries e Priority handling to meet defined time frames to restore the failing machine to good working condition e Committed repair service levels are measured within the following coverage hours e 24 7 6 Service performed 24 hours per day 7 days per week within 6 hours e 24 7 8 Service performed 24 hours per day 7 days per week within 8 hours e 24x7x24 Service performed 24 hours per day 7 days per week within 24 hours e Hard Drive Retention Lenovo s Hard Drive Retention service is a multi drive hard drive retention offering that ensures your data is always under your control regardless of the number of hard drives that are installed in your Lenovo server In the unlikely event of a hard drive failure you retain possession of your hard drive while Lenovo replaces the failed drive part Your data stays safely on your premises in your hands The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions e Microcode Support Keeping microcode current helps prevent hardware failures and security exposure There are two levels of service analysis of the installed base and analysis and update where required Offerings vary by country and can be bundled with other warranty upgrades and extensions e Remote Technical Support Services RTS RTS provides comprehensive technical call center support for covered servers storage operating Syste
40. bays NIC slots drive supply std std max max Express United States Canada 5463 EAU 1x E5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 2 5 Open 4xGbE 2 4 Multi 1x 550 W 15 1600MHz 85W 2133MHz HS 8 bay burner HS 2 5463 EBU 1x E5 2620 v3 6C 2 4GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Multi 1x 550 W 15 1866MHz 85W 2133MHz HS 8 bay burner HS 2 5463 EEU 2x E5 2620 v3 6C 2 4GHz 2x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Multi 2x 550 W 15 1866MHz 85W 2133MHz 2GB Flash HS 8 bay burner HS 2 5463 ECU 1x E5 2640 v3 8C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Multi 1x 550 W 20MB 1866MHz 90W 2133MHz HS 8 bay burner HS 2 5463 EDU 1x E5 2650 v3 10C 2 3GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Multi 1x 750 W 25MB 2133MHz 105W 2133MHz HS 8 bay burner HS 2 5463 EFU 2x E5 2650 v3 10C 2 3GHz 4x 16GB M5210 8x 2 5 Open 4xGbE 2 4 Multi 2x 550 W 25MB 2133MHz 105W 2133MHz 4GB Flash HS 8 bay burner HS 2 Express Latin America 5463 EMU 1x E5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 3 5 Open 4xGbE 4 4 Multi 1x 550 W 15 1600MHz 85W 2133MHz 55 4 burner HS 2 5463 ENU 1x E5 2609 v3 6C 1 9GHz 1x 8GB M5210 4x 2 5 2x 4 GbE 474 Multi 2x 550 W 15 1600MHz 85W 2133MHz 1GB Flash HS 8 300GB burner HS 2 10K 5463 ERU 1x E5 2609 v3 6C 1 9GHz 1x 8GB M1215 4x 2 5 Open 4xGbE 4 4 Multi 1x 550 W 15 1600MHz 85W 2133MHz 55 8 burner HS 2 5463 ESU 1x E5 2620 v3 6C 2 4GHz 1x 8GB M
41. bles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage l O intensive applications e Flexible and scalable internal storage configurations for up to 24 TB of storage capacity in a dense 10 rack form factor e Theuse of solid state drives SSDs instead of or along with traditional spinning hard disk drives HDDs can significantly improve I O performance An SSD can support up to 100 times more I O operations per second IOPS than a typical HDD e server has four integrated Gigabit Ethernet ports and optional 10 Gb Ethernet ports with mezzanine LOM ML2 adapters e server offers up to four PCI Express PCle 3 0 I O expansion slots in a dense 1U rack form factor e With Intel Integrated I O Technology the PCI Express 3 0 controller is integrated into the Intel Xeon processor E5 family This helps to dramatically reduce I O latency and increase overall system performance System x3550 M5 2 Availability and serviceability The x3550 M5 provides many features to simplify serviceability and increase system uptime Tool less cover removal provides easy access to upgrades and serviceable parts such as processors memory DIMMs and adapter cards The server offers hot swap drives supporting RAID redundancy for data protection and greater system uptime The server offers redundant hot swap power supplies and hot swap redundant fans to provide availability for business critical applica
42. can also elect to have a next gen ligh path LCD panel for models with 2 5 inch drive bays The following table shows the LCD display panel ordering information Table 22 Light path diagnostics options Standard Part Feature Maximum models where number code Description supported used 00 054 ASAB System x Advanced LCD Light path Kit 1 N2x P2x Q2x The following x3550 M5 Express models have the Advanced LCD Light path Kit standard E1G E2G E3G E4G E5J E6J E7J EAU EBU ECU EDU EEU EFU EHM EJM EKM ELM ENU EPU EQU ERU and ESU The following 3550 M5 TopSeller models have the Advanced LCD Light path Kit standard NDU NDG NMU NJU NEU NEG NNU NFU NHU NPU NKU NKG E8U E9U ETU and EUU IBM Security Key Lifecycle Manager for System x SEDs FoD SKLM FoD is an optional feature available in System x environments that centralizes simplifies and automates the data encryption key management process to help minimize risk and reduce operational costs SKLM FoD offers a simple and robust solution for key storage key serving and key lifecycle management for self encrypting drives SEDs in local and distributed System x environments With the x3550 the feature on demand FoD upgrade can be configured with the ServeRAID M5210 and M1215 RAID controllers paired with SEDs The following table lists SKLM FoD part numbers Table 23 Security Key Lifecycl
43. dcom NetXtreme Il ML2 Dual Port 10GbaseT for System 1 00D2028 40 Broadcom NetXtreme Il ML2 Dual Port 10GbE 5 for System 1 00D1996 A40Q Emulex VFA5 ML2 Dual Port 10GbE 5 Adapter for System 1 00D8544 4 2 Emulex VFA5 ML2 FCoE iSCSI License for System x FoD 1 Features on Demand upgrade for 00D1996 one for each adapter 00D1994 40 Intel X540 ML2 Dual Port 10GbaseT Adapter for System 1 94Y5200 AS74 Intel X710 ML2 4x10GbE SFP Adapter for System x 1 1 Gb Ethernet ML2 00D1998 A40R Intel 1350 4 ML2 Quad Port GbE Adapter for System x 1 40 Gb Ethernet FDR InfiniBand PCle 00D9550 A3PN Mellanox ConnectX 3 40GbE FDR IB VPI Adapter for System x 3 10 Gb Ethernet PCle 4471370 564 Broadcom 2x10GbE BaseT Adapter for System 3 94Y5180 426 Broadcom NetXtreme Dual Port 10GbE SFP Adapter for System 3 00JY820 ABUT Emulex VFA5 2x10 GbE SFP PCle Adapter for System 3 00JY824 ABUV Emulex VFA5 FCoE iSCSI SW for PCle Adapter for System x FoD 3 Features on Demand upgrade for 00JY820 one for each adapter 00JY830 A5UU Emulex VFA5 2x10 GbE SFP Adapter and FCoE iSCSI SW for System 49Y7960 A2EC Intel X520 Dual Port 10GbE SFP Adapter for System 3 49Y7970 A2ED Intel X540 T2 Dual Port 10GBaseT Adapter 3 81Y3520 AS73 Intel X710 2x10GbE SFP Adapter for System x 1 00D9690 A3PM Mellanox ConnectX 3 10 GbE Adapter for System x 3 90Y4600 A3MR Qlogic 8200 Dual Port
44. e Description Maximum number code supported Fibre Channel 16 Gb 81Y1675 A2XV Brocade 16Gb FC Dual port HBA for System x 3 81Y1668 A2XU Brocade 16Gb FC Single port HBA for System x 3 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA for System x 3 81Y1655 A2W5 Emulex 16Gb FC Single port HBA for System x 3 00Y3337 A3KW QLogic 16Gb FC Single port HBA for System x 3 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for System x 3 Fibre Channel 8 Gb 46M6050 3591 Brocade 8Gb FC Dual port HBA for System x 3 46M6049 3589 Brocade 8Gb FC Single port HBA for System x 3 42D0494 3581 Emulex 8Gb FC Dual port HBA for System x 3 42D0485 3580 Emulex 8Gb FC Single port HBA for System x 3 42D0510 3579 QLogic 8Gb FC Dual port HBA for System x 3 42D0501 3578 QLogic 8Gb FC Single port HBA for System x 3 SAS 00AE912 5 N2225 SAS SATA HBA for System x 3 00AE916 5 1 2226 5 5 5 for System 1 For more information see the list of Product Guides in the Host bus adapters category http lenovopress com systemx hba System x3550 M5 34 PCle SSD adapters The x3550 M5 server supports the High IOPS PCle SSD adapters listed in the following table Table 16 High IOPS PCle SSD adapters Part Feature Description Maximum number code supported Enterprise 00AE995 ARYP 1000GB Enterprise io3 Flash Adapter for System x 2 00AE998 ARYQ 1300GB Enterp
45. e Manager part numbers Part Feature Description Maximum number code supported United States Canada Asia Pacific and Japan 00D9998 A5U1 IBM SKLM for System x w SEDs FoD per Install w 1Yr S amp S 1 00D9999 AS6C IBM SKLM for System x w SEDs FoD per Install w 3Yr S amp S 1 Latin America Europe Middle East and Africa 00 648 A5U1 IBM SKLM for System x w SEDs per Install w 1Yr S amp S 1 00 649 AS6C IBM SKLM for System x w SEDs FoD per Install w 3Yr S amp S 1 System x3550 M5 40 Operating systems The server supports the following operating systems e Microsoft e Microsoft Windows Server 2012 R2 e Microsoft Windows Server 2012 e Microsoft Windows Server 2008 R2 e RedHat e RedHat Enterprise Linux 7 e Red Hat Enterprise Linux 6 Server x64 Edition Update 5 e SUSE SUSE Linux Enterprise Server 12 SUSE Linux Enterprise Server 12 with Xen SUSE Linux Enterprise Server 11 for AMD64 EM64T SP3 SUSE Linux Enterprise Server 11 with Xen for AMD64 EM64T SP3 e VMware e VMware vSphere 5 5 ESXi Update 2 e VMware vSphere 5 1 ESXi Update 2 See the ServerProven website for the latest information about the specific versions and service levels supported and any other prerequisites http www ibm com systems info x86servers serverproven compat us nos matrix shtml Physical and elec
46. e lists the drives supported by EXP2512 external expansion enclosures Table 28 Drive options for EXP2512 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 3 5 NL SAS HS HDDs 00 555 2TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00NC557 3TB 7 200 rpm 6Gb SAS NL 3 5 HDD 12 00 559 4 7 200 rpm 6Gb SAS NL 3 5 HDD 12 The following table lists the hard disk drives supported by EXP2524 external expansion enclosures Table 29 Drive options for EXP2524 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 2 5 NL SAS HS HDDs 00NC571 1TB 7 200 rpm 6Gb SAS NL 2 5 HDD 24 2 5 SAS HS HDDs 00 561 146GB 15 000 rpm 6Gb SAS 2 5 HDD 24 00 563 300GB 15 000 rpm 6Gb SAS 2 5 HDD 24 00 565 600GB 10 000 rpm 6Gb SAS 2 5 HDD 24 00 567 900GB 10 000 rpm 6Gb SAS 2 5 HDD 24 00 569 1 2 10 000 rpm 6Gb SAS 2 5 HDD 24 2 5 SAS HS SSDs 00NC573 200GB 6Gb SAS 2 5 SSD 24 00NC575 400GB 6Gb SAS 2 5 SSD 24 System x3550 M5 47 External disk storage systems The following table lists the external storage systems that are supported by the server and that can be ordered through System x sales channel The server might support other disk systems that are not listed in this table Refer to the IBM S
47. est of maximum operating speeds for selected memory configuration that depends on quantity of DIMMs per channel as shown under Maximum operating speed in Table 5 The following memory protection technologies are supported e ECC e Chipkill for x4 based memory DIMMs Chipkill works only in independent channel mode the default is operational mode and supports only x4 based memory DIMMs System x3550 M5 The following table shows the characteristics of the supported DIMMs Table cells highlighted with a gray background indicate when the number of DIMMs per channel still allows the DIMMs to operate at a rated speed Table 5 Maximum memory speeds DIMM specification RDIMM LRDIMM Rank Single rank Dual rank Quad rank Part numbers 46W0784 4 GB 46W0792 8 GB 46W0796 16 GB 46W0800 32 GB 46W0788 8 GB 95Y4808 32 GB 95Y4812 64 GB Rated speed 2133 MHz 2133 MHz 2133 MHz 2133 MHz Rated voltage 1 2V 1 2V 1 2V 1 2V Maximum quantity supported 24 24 24 24 Maximum DIMM capacity 8GB 8GB 32 GB 64 GB Maximum memory capacity 192 GB 192 GB 768 GB 1 5 TB Maximum memory at rated 128 GB 128 GB 512 GB 512 GB speed Maximum operating speed 1 DIMM per channel 2133 MHz 2133 MHz 2133 MHz 2133 MHz 2 DIMMs per channel 2133 MHz 2133 MHz 2133 MHz 2133 MHz 3 DIMMs per channel 1600 MHz 1600 MHz 1866 MHz 1866 MHz The maximum qua
48. he System x3550 M5 The following figure shows the locations of key components inside the server PCle PCle SATA RAID controller in Light path diagnostics Riser 1 Riser2 ports dedicated slot CPU 1 LCD panel and optical drive Euer umo Hot swap power USB socketfor 24 DIMM 2 8 hot swap supply bays hypervisor slots fans bays Figure 4 Inside view of the System x3550 M5 System x3550 M5 Standard specifications The following table lists the standard specifications Table 1 Standard specifications part 1 Components Specification Machine type 5463 Form factor 1U Rack Processor Up to two Intel Xeon processor E5 2600 v3 product family CPUs with 18 or 16 cores 2 3 GHz core speeds or 14 12 or 10 cores up to 2 6 GHz core speeds or 8 cores up to 3 2 GHz core speeds or 6 cores up to 3 4 GHz core speeds or 4 cores up to 3 5 GHz core speeds Two QPI links up to 9 6 GT s each Up to 2133 MHz memory speed Up to 45 MB L3 cache Chipset Intel C612 Memory Up to 24 DIMM sockets 12 DIMMs per processor RDIMMs and LRDIMMs Load Reduced DIMMs are supported Memory types cannot be intermixed Memory speed up to 2133 MHz Memory e With RDIMMs Up to 768 GB with 24x 32 GB RDIMMs and two processors maximums e With LRDIMMs Up to 1 5 TB with 24x 64 GB LRDIMMs and two processors Memory Error correction code ECC Chipkill for x4 based memory DIMMs pr
49. ibm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlfid 897 ENUS1 14 141 ServerProven hardware compatibility page for the x3550 M5 http www ibm com systems info x86servers serverproven compat us xseries 5463 html Product Guides for System x servers and options http lenovopress com systemx Configuration and Option Guide http www ibm com systems xbc cog xRef System x Reference Sheets http lenovopress com xref System x Support Portal http ibm com support entry portal http ibm com support entry portal Downloads Hardware Systems System x System x3550 M5 System Storage Interoperation Center http www ibm com systems support storage ssic System x3550 M5 57 Notices Lenovo may not offer the products services or features discussed in this document in all countries Consult your local Lenovo representative for information on the products and services currently available in your area Any reference to a Lenovo product program or service is not intended to state or imply that only that Lenovo product program or service may be used Any functionally equivalent product program or service that does not infringe any Lenovo intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any other product program or service Lenovo may have patents or pending patent applications covering subject matter described in this document The furni
50. isted in the following table Up to nine expansion enclosures can be daisy chained per one M5225 external port For better performance distribute expansion enclosures evenly across both M5225 ports Table 26 External expansion enclosures Part number Description Maximum quantity supported per one M5225 70F0 70F 1 Lenovo ThinkServer SA120 8 610012 EXP2512 Storage Enclosure 17 610024X EXP2524 Storage Enclosure 9 Lenovo ThinkServer SA120 support For details about supported drives and cables for the Lenovo ThinkServer SA120 see the Lenovo Press Product Guide http lenovopress com tips 1234 EXP2512 and EXP2524 support The external SAS cables listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5225 SAS SATA Controller Table 27 External SAS cables for external storage expansion enclosures Maximum quantity supported per one enclosure Part number Description Server to Expansion enclosure connectivity Mini SAS HD x4 to Mini SAS x4 00MJ162 0 6m SAS Cable mSAS HD to mSAS 1 00MJ163 1 5m SAS Cable mSAS HD to mSAS 1 00MJ166 3m SAS Cable mSAS HD to mSAS 1 Expansion enclosure to Expansion enclosure connectivity Mini SAS x4 to Mini SAS x4 39R6529 1m SAS Cable 1 39R6531 3 SAS Cable 1 System x3550 M5 46 The following tabl
51. lenovo System x3550 M5 Lenovo Press Product Guide Designed in a compact versatile 1U two socket rack server the System x3550 M5 rack server fuels almost any workload from infrastructure to high performance computing HPC to cloud or big data with leadership security efficiency and reliability Integrated with up to two Intel Xeon processors of the E5 2600 v3 product family with faster energy efficient TruDDR4 Memory the x3550 M5 delivers exceptional performance Storage can include up to 12 drives in an impressive selection of sizes and types Suggested use Database virtualization and cloud computing infrastructure security systems management enterprise applications collaboration email streaming media web and HPC The following figure shows the System x3550 M5 Figure 1 The System x3550 M5 Did you know The x3550 M5 incorporates energy smart features for minimized costs and efficient performance Dual fan zones support operation in up to 40 C environments 80 PLUS Titanium power supply units PSUs can deliver 9696 efficiency at 5096 load The x3550 M5 has outstanding memory performance that is achieved by supporting two RDIMM per channel configurations at speeds up to 1296 faster than the Intel specification while still maintaining world class reliability System x servers achieved the highest reliability of any x86 servers ITIC 2014 2015 Global Server Hardware Server OS Reliability Survey ht
52. ms and applications Providing a single source for support of hardware and software issues RTS can reduce problem resolution time decreasing the cost to address technical problems and increasing uptime Offerings are available for Windows Linux IBM Systems Director VMware Microsoft business applications and Lenovo System x storage devices and IBM OEM storage devices System x3550 M5 44 Regulatory compliance The server conforms to the following regulations FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES 003 issue 5 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class A Australia New Zealand AS NZS CISPR 22 Class A AS NZS 60950 1 China CCC GB4943 1 GB9254 Class GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia Belorussia and Kazakhstan TR CU 020 2011 for EMC and TR CU 004 2011 for safety IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 EN61000 3 3 CISPR 22 Class A TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 External disk storage expansion The server supports attachment to external storage expansion enclosures such as the EXP2500 series by using the ServeRAID M5225 SAS SATA Controller The server can also be attached to supported external storage systems such as the IBM Storwize V3700 using the supported HBAs The following table shows the
53. nd 9x5 Next Business Day onsite coverage Also available are Lenovo Services warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions Lenovo warranty service upgrade offerings are country specific Not all warranty service upgrades are available in every country For more information about Lenovo warranty service upgrade offerings that are available in your country visit the Lenovo Services website https www 304 ibm com sales gss download spst servicepac The following table explains warranty service definitions in more detail Table 24 Warranty service definitions Term Description On site A service technician will arrive at the client s location for equipment service service 24x7x2 hour A service technician is scheduled to arrive at the client s location within two hours after remote problem determination is completed Lenovo provides service around the clock every day including Lenovo holidays 24x7x4 hour A service technician is scheduled to arrive at the client s location within four hours after remote problem determination is completed Lenovo provides service around the clock every day including Lenovo holidays 9x5x4 hour A service technician is scheduled to arrive at the client s location within four business hours after remote problem dete
54. ntity that is supported is shown for two processors installed System x3550 M5 The following table lists memory options available for the x3550 5 server Table 6 Memory options Part Feature Description Maximum Standard models where number code supported used RDIMMs 2133 MHz 46W0784 A5B6 4GB TruDDR4 Memory 1Rx8 1 2V 24 12 4 17000 15 2133MHz LP RDIMM 46W0788 5 5 8GB TruDDR4 Memory 1 4 1 2 24 12per 4 17000 CL15 2133MHz LP RDIMM CPU 46W0792 A5B8 8GB TruDDR4 Memory 2Rx8 1 2V 24 12 2 B2x PC4 17000 CL15 2133MHz LP RDIMM CPU 46W0796 A5B7 16GB TruDDR4 Memory 2Rx4 1 2V 24 12 62x C2x C4x D2x F2x PC4 17000 CL15 2133MHz LP RDIMM CPU G2x H2x J2x L2x M2x N2x P2x Q2x 95Y4808 A5UJ 32GB TruDDR4 Memory 2 4 1 2V 24 12 per PC4 17000 CL15 2133MHz LP RDIMM CPU LRDIMMs 2133 MHz 46W0800 A5B9 32GB TruDDR4 Memory 4Rx4 1 2V 24 12 per PC417000 CL15 2133MHz LP LRDIMM CPU 95Y4812 ASUK 64GB TruDDR4 Memory 4Rx4 1 2V 24 12 4 17000 15 2133MHz LP LRDIMM System x3550 5 Internal storage The System x3550 M5 server supports the following internal drive bay configurations 1 4x2 5 inch SAS SATA hot swap drive bay server models that can be upgraded to 8x 2 5 inch SAS SATA hot swap drive bays 2
55. on costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and payment requirements For you this dedication provides a high quality easy and positive financing experience For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services For more information see the following Lenovo website http www lenovo com services warranty us en financial services html System x3550 M5 56 Related publications and links For more information see these resources System x3550 M5 product page http www ibm com systems x hardware rack x3550mb index html System x3550 M5 Type 5463 Installation and Service Guide http publib boulder ibm com infocenter systemx documentation topic com ibm sysx 5463 doc r printable doc html US Announcement Letter May 5 2015 http ibm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlfid 897 ENUS 1 15 066 US Announcement Letter September 9 2014 http
56. ont to Rear 7159GR6 Lenovo RackSwitch G8296 Rear to Front 40 Gb top of rack switches 7159BFX Lenovo RackSwitch G8332 Front to Rear 7159BRX Lenovo RackSwitch G8332 Rear to Front For more information see the list of Product Guides in the Top of rack switches category http lenovopress com systemx tor System x3550 M5 50 Uninterruptible power supply units The server supports attachments to the uninterruptible power supply UPS units listed in the following table Table 33 Uninterruptible power supply units Part number Description Rack mounted or tower UPS units 55941AX RT1 5kVA 2U Rack or Tower UPS 100 125VAC 55941KX RT1 5kVA 2U Rack or Tower UPS 200 240VAC 55942AX RT2 2kVA 2U Rack or Tower UPS 100 125VAC 55942KX RT2 2kVA 2U Rack or Tower UPS 200 240VAC 55943AX RT3KVA 2U Rack or Tower UPS 100 125VAC 55943KX RT3KVA 2U Rack or Tower UPS 200 240VAC 55945KX RT5kVA 30 Rack or Tower UPS 200 240VAC 55946KX RT6kVA Rack or Tower UPS 200 240VAC 55948KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55948PX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Rack mounted UPS units 53951AX 1500VA LCD
57. osts Scalability and performance The x3550 M5 offers numerous features to boost performance improve scalability and reduce costs e Improves productivity by offering superior system performance with up to 18 core processors up to 45 MB of L3 cache and up to 9 6 GT s QPI interconnect links e Supports up to two processors 36 cores and 72 threads to maximize the concurrent execution of multithreaded applications e Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP e Intel Hyper Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core e Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating System vendors to better utilize the hardware for virtualization workloads e Intel Advanced Vector Extensions 2 0 AVX 2 0 enable acceleration of enterprise class workloads such as databases enterprise resource planning and others e Upto 2133 MHz memory speeds with two DIMMs per channel running at 2133 MHz to help maximize system performance e Upto 1 5 TB of memory capacity with 64 GB Load Reduced DIMMS LRDIMMs support for 64 GB LRDIMMs is planned for a later date e 12 Gbps serial attached SCSI SAS internal storage connectivity dou
58. otection Disk drive bays Up to 12x 2 5 hot swap SAS SATA HDDs up to 8x 2 5 Simple Swap SATA HDDs or up to 4x 3 5 hot swap SAS SATA or up to 4x 3 5 Simple Swap SATA HDDs Maximum internal storage Up to 21 6 TB with 1 8 TB 2 5 SAS HDDs or up to 12 TB with 1 TB 2 5 NL SAS SATA HDDs or up to 38 4 TB with 3 84 TB 2 5 SAS SSDs or up to 24 TB with 6 TB 3 5 NL SAS SATA HDDs Intermix of SAS SATA is supported Storage controller e Onboard 6 Gb SATA no RAID support e 12Gb SAS SATA RAID 0 1 10 with M1215 or M5210 Optional upgrade to RAID 5 50 is available for M1215 Optional upgrade to RAID 5 50 is available for M5210 zero cache 1 GB non backed cache 1 GB 2 GB or 4 GB flash backed cache Optional upgrade to RAID 6 60 is available for M5210 with memory cache upgrades Optional SSD Caching and Performance Accelerator feature upgrades are available e 12 Gb SAS SATA non RAID N2215 HBA Optical drive bays One optional for models with 4 or 8 drive bays models with 10 drive bays do not support an internal optical drive Support for DVD ROM or Multiburner Tape drive bays None Network interfaces Four integrated RJ 45 Gigabit Ethernet 1000BASE T ports BCM5719 optional Mezzanine LOM ML2 slot for dual port 10 GbE cards with SFP or RJ 45 connectors or quad port GbE cards with RJ 45 connectors PCI Expansion slots Up to four slots
59. ou can replace the first riser card or add a second riser card with the riser card options that are listed in the following table or configure these riser cards to be factory integrated using special bid or CTO Table 12 PCI riser card options Part Feature Maximum Standard models number code Description supported where used Riser 1 supplies slots 1 00KA061 System x3550 M5 PCIe Riser 1 1x LP x16 CPUO 62x J2x A2x B2x C2x C4x D2x F2x G2x H2x L2x M2x 00KA063 A5AH System x3550 M5 PCIe Riser 1 1x ML2 x16 CPUO 1 Riser 2 supplies slots 2 and 3 00 062 ABAC System x3550 M5 PCIe Riser 2 1 CPU 2xLP LP x8 1 CPUO LP x8 CPUO None A5AD System x3550 M5 PCle Riser 2 1 2 CPU FHHL x16 CPU1 LP x16 CPUO ASAE System x3550 5 PCIe Riser 2 1 CPU FHHL x8 CPUO LP x8 CPUO 00 066 ASAF System x3550 M5 PCle Riser 2 1 2 CPU LP x16 CPU1 LP x16 CPUO k Only available via or special bid Note The HDD Rear Kit 00KA058 see the Internal storage section is installed in place of the PCle slots 1 and 2 and it includes a special riser that provides PCle 3 0 x16 slot 3 No other riser cards can be used when the HDD Rear Kit is installed The x3550 M5 Thermal Kit part number 00 059 contains two fans It provides the seventh
60. power supplies with 80 PLUS Platinum and Titanium certifications Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments Low voltage 1 2 V DDR4 memory DIMMs offer energy efficiency compared to 1 35 V and 1 5 V DDR3 DIMMs The server uses hexagonal ventilation holes a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system IBM Systems Director Active Energy Manager and Intel Node Manager provide advanced data center power notification and management to help achieve lower heat output and reduced cooling needs Locations of key components and connectors The following figure shows the front of the server Light path diagnostics USB3 0 Power Status LCD display panel port button LEDs 2 5 inch HS drive bays USB2 0 Optical Video 2 5 inch SS and 3 5 inch HS and SS drive bays available port drive port Figure 2 Front view of the System x3550 M5 System x3550 M5 The following figure shows the rear of the x3550 M5 server with three PCIe low profile slots 3x PCle slots Ethernet pot 2x USB 3 0 05820 4x1GbE Video 2x hot swap for IMM ports port ports port power supplies Figure 3 Rear view of t
61. ra Density Enterprise PDU C19 PDU WW 71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 71763NU Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 39M2816 DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P G 208 V fixed line cord 39Y8941 DPI Single Phase C13 Enterprise PDU without line cord 39Y8948 DPI Single Phase C19 Enterprise PDU without line cord Front end PDUs 39Y8934 DPI 32 amp 250 V Front end PDU with IEC 309 2P Gnd connector 39Y8935 DPI 63amp 250 V Front end PDU with IEC 309 2P Gnd connector 39Y8938 30 amp 125 V Front end PDU with NEMA L5 30P connector 39Y8939 30 amp 250 V Front end PDU with NEMA L6 30P connector 39Y8940 60 amp 250 V Front end PDU with IEC 309 60A 2P N Gnd connector System x3550 M5 52 Table 34 Power distribution units part 2 Part number Description Universal PDUs 39Y8951 DPI Universal Rack PDU with US LV and HV line cords 39Y8952 DPI Universal Rack PDU with CEE7 VII Europe LC 39Y8953 DPI Universal Rack PDU with Denmark LC 39Y8954 DPI Universal Rack PDU with Israel LC 39Y8955 DPI Universal Rack PDU with Italy LC 39Y8956 DPI Universal Rack PDU with South Africa LC 39Y8957 DPI Universal Rack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Univer
62. rademarks Lenovo For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States other countries or both These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol or indicating US registered or common law trademarks owned by Lenovo at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Lenovo Lenovo logo PureFlex RackSwitch ServeRAID ServerProven System x ToolsCenter TruDDR4 The following terms are trademarks of other companies Intel Intel Xeon Intel logo Intel Inside logo and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both LTO Ultrium the LTO Logo and the Ultrium logo are trademarks of HP IBM Corp and Quantum in the U S and other countries Microsoft Windows and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Other company product or service names may be trademarks or
63. reading as DVD ROM part number 00AMO66 This drive also supports the following media and speeds for writing System x3550 M5 CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed CD RW 24X DVD R 8X DVD R 8X DVD R DL 6X DVD R DL 6X DVD RW 6X DVD RW 8X DVD RAM 5X 28 1 expansion options The x3550 M5 server supports up to four PCle slots one on the system planar that is dedicated for an internal RAID controller and up to three with different riser cards installed into two riser sockets on the system planar one riser socket supports the installation of one riser card The slot form factors are listed e Slot 1 PCle 3 0 x16 or ML2 low profile half length not present if the HDD Rear Kit is installed e Slot 2 PCle 3 0 x16 or PCle 3 0 x8 low profile or full height half length PCle 3 0 x16 slot requires the second processor to be installed not present if the HDD Rear Kit is installed e Slot 3 PCle 3 0 x16 or PCle 3 0 x8 low profile half length e Slot 4 PCle 3 0 x8 dedicated for an internal RAID controller The locations of the PCle slots are shown in the following figure 43 Cas 2 5 HS drivebay ME Figure 6 PCIe slot locations System x3550 M5 29 Riser 1 supplies slot 1 and 2 supplies slots 2 and 3 All standard models have riser card Riser 1 installed which provides one low profile PCle x16 Gen 3 slot riser option part number 00 061 Y
64. rise io3 Flash Adapter for System x 2 00JY001 ARYR 2600GB Enterprise io3 Flash Adapter for System x 2 00JY004 ARYS 5200GB Enterprise io3 Flash Adapter for System x 1 Enterprise Value 00AE983 ARYK 1250GB Enterprise Value io3 Flash Adapter for System x 2 00 986 ARYL 1600GB Enterprise Value io3 Flash Adapter for System x 2 00AE989 ARYM 3200GB Enterprise Value io3 Flash Adapter for System x 2 00AE992 ARYN 6400GB Enterprise Value io3 Flash Adapter for System x 1 The 5200GB and 6400GB 103 Flash Adapters cannot be factory installed they are supported as field installable options only The server cannot be shipped with these adapters installed GPU adapters The x3550 5 server supports a graphics processing units GPUs listed in the following table Table 17 GPU adapters Part Feature Description Maximum number code supported None ASPN NVIDIA Quadro K420 1 None A3WH NVIDIA Quadro K600 1 None ASPP NVIDIA Quadro K620 1 These GPU adapters are available only through Special Bid or CTO If the NVIDIA Quadro adapter is installed the maximum memory that can be installed is 1 TB System x3550 M5 35 Power supplies The x3550 M5 server supports up to two redundant power supplies and is capable of N N redundancy depending on the configuration Standard models come with one power supply The following table lists the power supplies Table 18 Power supplies
65. rmination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local time zone Monday Friday excluding Lenovo holidays For example if a customer reports an incident at 3 00 pm on Friday the technician will arrive by 10 00 am the following Monday 9x5 next business day A service technician is scheduled to arrive at the client s location on the business day after remote problem determination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local time zone Monday Friday excluding Lenovo holidays Calls received after 4 00 pm local time require an extra business day for service dispatch Next business day service is not guaranteed Committed Repair Problems receive priority handling so that repairs are completed within the committed time of 6 8 or 24 hours Lenovo provides service 24 hours day every day including Lenovo holidays System x3550 M5 43 The following Lenovo warranty service upgrades are available e Warranty and maintenance service upgrades Three four or five years of 9x5 or 24x7 service coverage Onsite response from next business day to 2 or 4 hours Committed repair service Warranty extension of up to 5 years Post warranty extensions e Committed Repair Service Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty Maintenance Service offering associated with the selected systems Offerings v
66. sal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI Universal Rack PDU India OU Basic PDUs 46M4122 OU 24 C13 16A 3 Phase PDU 46M4125 OU 24 C13 30A 3 Phase PDU 46M4128 OU 24 C13 30A PDU 46M4131 OU 24 C13 32A PDU 46M4140 OU 12 C19 12 C13 60A 3 Phase PDU 46M4143 OU 12 C19 12 C13 32A 3 Phase PDU For more information see the list of Product Guides in the Power infrastructure category http lenovopress com systemx power System x3550 M5 53 Rack cabinets The server supports the rack cabinets listed in the following table Table 35 Rack cabinets Part number Description 201886X 11U Office Enablement Kit 93072RX 25U Standard Rack 93072PX 25U Static S2 Standard Rack 93634EX 42U 1100mm Dynamic Expansion Rack 93634PX 42U 1100mm Dynamic Rack 93604EX 42U 1200mm Deep Dynamic Expansion Rack 93604PX 42U 1200mm Deep Dynamic Rack 93614EX 42U 1200mm Deep Static Expansion Rack 93614PX 42U 1200mm Deep Static Rack 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 93074RX 42U Standard Rack 93074XX 42U Standard Rack Extension 93624EX 47U 1200mm Deep Static Expansion Rack 93624PX 47U 1200mm Deep Static Rack 93634BX PureFlex amp System 42U Expansion Rack 93634DX PureFlex System 42U Expansion Rack 93634AX PureFlex System 42U Rack 93634CX Pure
67. service marks of others System x3550 M5 59
68. shing of this document does not give you any license to these patents You can send license inquiries in writing to Lenovo United States Inc 1009 Think Place Building One Morrisville NC 27560 U S A Attention Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All information contained in this document was obtained
69. software Dimensions Height 43 mm 1 7 in width 429 mm 16 9 in depth 734 mm 28 9 in Weight Minimum configuration 13 8 kg 30 5 Ib maximum 19 3 kg 42 7 Ib The x3550 M5 servers are shipped with the following items supplies Statement of Limited Warranty Important Notices Rack Installation Instructions Documentation CD containing nstallation and User s Guide System x3550 M5 Slide Kit G4 2 8 m C13 C14 power cord one for models with one power supply and two for models with two power Note Cable Management Arm CMA is not included See the Rack options section for ordering information System x3550 M5 Standard models The following table lists the standard models of the x3550 M5 Table 2 Standard models MTM Intel Xeon processort Memory RAID Drive Drives Onboard I O Optical Power 2 maximum RDIMMs bays NIC slots drive supply std std max max Models announced May 2015 5463 P2U 1x E5 2660 v3 10C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4 2 4 Optional 1x 750 25MB 2133MHz 105W 2133MHz 2GB Flash HS 8 bay HS 2 5463 Q2U 1x E5 2667 v3 8C 3 2GHz 1x 16GB M5210 4x 2 5 Open 4xGbE 2 4 Optional 1x 750 W 20MB 2133MHz 135W 2133MHz 2GB Flash HS 8 bay HS 2 5463 N2U 1x E5 2697 v3 14C 2 6GHz 1x 16GB M5210 4x 2 5 Open 4
70. tel Xeon Processor E5 2650L v3 12 1 8GHz 30MB Cache 2133MHz 65W 00MU570 ASLA ASLK Intel Xeon Processor E5 2658 v3 12C 2 2GHz 30MB Cache 2133MHz 105W 00 0400 ASCL ASCX Intel Xeon Processor E5 2660 v3 10C 2 6GHz 25MB Cache 2133MHz 105W P2x 00MU410 ASCW ASD7 Intel Xeon Processor E5 2667 v3 8C 3 2GHz 20MB Cache 2133MHz 135W Q2x 00 074 ASBK ASBZ Intel Xeon Processor E5 2670 v3 12C 2 3GHz 30MB Cache 2133MHz 120W 62x 00KA075 ASBL ASCO Intel Xeon Processor E5 2680 v3 12C 2 5GHz 30MB Cache 2133MHz 120W J2x 00 0401 ASCM Intel Xeon Processor E5 2683 v3 14C 2 0GHz 35MB Cache 2133MHz 120W 00 0402 ASCN ASCZ Intel Xeon Processor E5 2685 v3 12C 2 6GHz 30MB Cache 2133MHz 120W 00KA076 5 5 1 Intel Xeon Processor 5 2690 v3 12C 2 6GHz 30MB Cache 2133MHz 135W L2x 00 0403 ASCP ASDO Intel Xeon Processor 5 2695 v3 14C 2 3GHz 35MB Cache 2133MHz 120W 00 0404 ASCQ ASD1 Intel Xeon Processor E5 2697 v3 14C 2 6GHz 35MB Cache 2133MHz 145W N2x 00 0405 ASCR ASD2 Intel Xeon Processor E5 2698 v3 16C 2 3GHz 40MB Cache 2133MHz 135W OOKF584 ARZ8 29 Intel Xeon Processor E5 2699 v3 18C 2 3GHz 45MB Cache 2133MHz 145W M2x The first feature code is for the first processor the second feature code is for the second processor System x3550 M5
71. tions The new next gen light path diagnostics LCD display panel simplifies servicing speeds up problem resolution and helps improve system availability Predictive Failure Analysis PFA detects when system components processors VRMs memory disks fans and power supplies operate outside standard thresholds and generates proactive alerts in advance of possible failure therefore increasing uptime SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime Built in Integrated Management Module II IMM2 continuously monitors system parameters triggers alerts and performs recovery actions in case of failure to minimize downtime Built in diagnostics using Dynamic Systems Analysis DSA Preboot speed up troubleshooting tasks to reduce service time Three year customer replaceable unit and onsite limited warranty next business day 9x5 Optional service upgrades available Manageability and security Powerful systems management features simplify local and remote management of the x3550 M5 and deliver enterprise class data protection System x3550 M5 The server includes an Integrated Management Module II IMM2 to monitor server availability and perform remote management An integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error handling IBM Systems Director offers comprehensive systems management
72. tools to help increase uptime reduce costs and improve productivity through advanced server management capabilities Two integrated Trusted Platform Modules TPMs support the enablement of advanced cryptographic functionality such as digital signatures and remote attestation System x Trusted Platform Assurance an exclusive set of System x security features and practices establishes a foolproof security foundation for workloads by delivering firmware that is securely built tested digitally signed and verified prior to execution The server offers enterprise class data protection with optional self encrypting drives and simple centralized key management through IBM Security Key Lifecycle Management There is industry standard AES NI support for faster stronger encryption Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system Intel Trusted Execution Technology provides enhanced security through hardware based resistance to malicious software attacks allowing an application to run in its own isolated space protected from all other software running on a system Energy efficiency The x3550 M5 offers the following energy efficiency features to save energy reduce operational costs increase energy availability and contribute to a green environment Energy efficient planar components help lower operational costs High efficiency
73. tp public dhe ibm com common ssi ecm en xsl03126usen XSL03126USEN PDF The x3550 M5 integrates leadership security and reliability System x Trusted Platform Assurance an exclusive set of System x features and practices establishes a foolproof security foundation for your workloads Enterprise class data protection is provided with optional self encrypting drives and simple centralized key management through IBM Security Key Lifecycle Management Diagnostic tools facilitate reduced downtime and costs System x3550 M5 1 Key features The System x3550 Mb is cost and density balanced 1U 2 socket business critical server offering improved performance and pay as you grow flexibility along with new features that improve server management capability New innovative energy smart design with powerful high performance processors a large capacity of high performing DDR4 memory and an improved feature set are ideal for business critical applications and cloud deployments Combining balanced performance and flexibility the x3550 M5 is a great choice for small and medium businesses and up to the large enterprise It can provide outstanding uptime to keep business critical applications and cloud deployments running safely Ease of use and comprehensive systems management tools make it easy to deploy Outstanding reliability availability and serviceability RAS and high efficiency design improve your business environment and help save operational c
74. trical specifications Dimensions and weight approximate Height 43 mm 1 7 in Width 429 mm 16 9 in Depth 734 mm 28 9 in Weight e Minimum configuration 13 8 kg 30 5 Ib e Maximum configuration 19 3 kg 42 7 Ib Supported environment e Airtemperature e Server on 5 C to 40 C 41 F to 104 F altitude 0 to 950 m 3 117 ft decrease the maximum system temperature by 1 C for every 175 m increase in altitude above 950 m e Server off 5 C to 45 41 F to 113 F e Maximum altitude 3 050 m 10 000 ft 5 C to 28 C 41 F to 82 F e Shipment 40 C to 60 C 40 F to 140 F at up to 10 700 m 35 105 ft e Humidity e Server on 8 to 85 maximum dew point 24 C maximum rate of change 5 C hr e Server off 8 to 85 maximum dew point 27 C System x3550 M5 41 e Design to ASHRAE Class ambient of 40 104 F with relaxed support e Supports cloud like workload with no performance degradation acceptable Turbo Off e Under no circumstance can any combination of worst case workload and configuration result in system shutdown or design exposure at 40 e Electrical e Models with 1500 W AC Platinum power supplies e 200 240 nominal V ac 50 Hz or 60 Hz 8 35 A e Input kilovolt amperes kVA approximately e Minimum configuration 0 14 e Maximum configuration 1 967 kVA Models with 900 W AC Platinum power supplies e 100to 127 nominal V ac
75. upport IEEE 1588 protocol and 802 1AS time synchronization implementation IEEE802 3az Energy Efficient Ethernet EEE I O Virtualization features e Virtualization support for VMware NetQueue and Microsoft virtual machine queue VMQ e Function Level Reset FLR e EEE 802 1q Virtual Local Area Network VLAN tagging support Stateless offload and performance features TCP IP and User Datagram Protocol UDP checksum offload TCP segmentation offload TCO Large Send Offload LSO Receive Side Scaling RSS and Transmit Side Scaling TSS Message Signal Interrupt MSI and Message Signal Interrupt Extension MSI X support Support for jumbo frames up to 9600 bytes Optionally the x3550 M5 server supports ML2 adapters that are installed in the custom ML2 slot provided by the PCle ML2 riser card part number 00KA063 This slot supports adapters with either two 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 service processor for out of band systems management System x3550 M5 31 The following table lists additional supported network adapters Table 14 Network adapters Part 1 Part Feature Description Maximum number code supported 40 Gb Ethernet ML2 OOFP650 A5RK Mellanox ConnectX 3 Pro ML2 2x40GbE FDR VPI Adapter for System x 1 10 Gb Ethernet ML2 00D2026 405 Broa
76. ystem Storage Interoperation Center for further information http www ibm com systems support storage ssic Table 30 External disk storage systems Part number Description 2071CU2 Storwize V3500 LFF Dual Control Enclosure 2071CU3 Storwize V3500 SFF Dual Control Enclosure 6099L2C Storwize V3700 3 5 inch Storage Controller Unit 609952 Storwize V3700 2 5 inch Storage Controller Unit 6099T2C Storwize V3700 2 5 inch DC Storage Controller Unit For more information see the list of Product Guides in the System Storage category http lenovopress com systemx externalstorage System x3550 M5 48 External backup units The server supports the external backup attachment options listed in the following table Table 31 External backup options Part number Description External tape expansion enclosures for internal tape drives 87651UX 1U Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure with Nema 5 15P LineCord Tape enclosure adapters with cables 44E8869 USB Enclosure Adapter Kit Internal backup dri ives supported by external tape enclosures 00D2786 RDX Internal USB 3 0 Dock with 320GB Cartridge 00D2787 RDX Internal USB 3 0 Dock with 500GB Cartridge 00D2788 RDX Internal USB 3 0 Dock with 1TB Cartridge External backup u nits 362532Y RDX External USB 3 0 Dock with 320GB Cartridge 362550Y RD

Download Pdf Manuals

image

Related Search

Related Contents

Logix5000 Controllers Add-on Instructions Programming Manual  Ponencia D. Roberto Pozuelo León (965 kbytes)  Quaderno di Formazione per la SICUREZZA SUL LAVORO  Fujitsu Siemens Computers X103 SFF User's Manual  Samsung PN60E530A3F  Med Tips-2012 Jan - Chart Industries  取扱説明書 - 三菱電機  Bunn JDF-4S User's Manual  Normativa EASA Part 66 (testo completo in italiano)    