Home

MEAN WELL LPV-35-12 power supply unit

image

Contents

1. for more details 5 The power supply is considered a component which will be installed a final equipment The final equipment must be re confirmed that it still meets 6 Fa time is measured at first cold start Turning ON OFF the power supply may lead to increase of the set up time File Name LPV 35 SPEC 2008 06 03 MW L PV 3 5 series 35W Single Output Switching Power Supply MEAN WELL E Mechanical Specification Case No 975A Unit mm 600 148 600 3 5 18AWG olin AC L Brown wee 16AWG AC N Blue lt s m Red SL V Black 3 5 ar 30 E Block Diagram LOAD 30 AMBIENT TEMPERATURE C LOAD 100 90 80 70 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE V 60Hz fosc 65KHz EMI FILTER POWER RECTIFIERS Fe vy I P o amp amp RECTIFIERS HS FILTER 3 V DETECTION o L P ccc ybL coca E FY CIRCUIT 4 Nee e ovr E Derating Curve H Static Characteristics Ta 25 C File Name LPV 35 SPEC 2008 06 03
2. MW L PV 3 5 series 35W Single Output Switching Power Supply MEAN WELL SPECIFICATION H Features Constant voltage mode power supply Universal AC input Full range Withstand 300VAC surge input for 5 seconds Fully isolated plastic case Cooling by free air convection 100 full load burn in test Low cost high reliability J 2 years warranty es Protections Short circuit Overload Over voltage Suitable for LED lighting and moving sign applications MODEL LPV 35 5 LPV 35 12 LPV 35 15 LPV 35 24 LPV 35 36 DC VOLTAGE 5V 12V 15V 24V 36V RATED CURRENT 6A 3A 2 4A 1 5A 1A CURRENT RANGE 0 6A 0 3A 0 2 4A 0 1 5A 0 1A RATED POWER 30W 36W 36W 36W 36W OUTPUT RIPPLE amp NOISE max Note 2 80mVp p 120mVp p 120mVp p 150mVp p 150mVp p VOLTAGE TOLERANCE Note 3 6 0 5 0 LINE REGULATION 1 0 LOAD REGULATION 4 0 42 0 SETUP RISE TIME Note 6 500ms 20ms 230VAC 500ms 20ms 115VAC at full load HOLD UP TIME Typ 50ms 230VAC 16ms 115VAC at full load VOLTAGE RANGE 90 264VAC FREQUENCY RANGE 47 63Hz INPUT EFFICIENCY Typ 77 85 85 86 86 AC CURRENT 1 1A 115VAC 0 7A 230VAC INRUSH CURRENT max COLD STAR 30A 115VAC 60A 230VAC LEAKAGE CURRENT 0 25mA 240VAC OVER CURRENT Noto 110 150 rated output power PROTECTION Protection type Hiccup mode recovers auto
3. matically after fault condition is removed 5 75 6 75V 13 8 16 2V 17 25 20 25V 27 6 32 4V 41 4 48 6V OVER VOLTAGE Protection type Shut down o p voltage re power on to recover WORKING TEMP 30 75 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing ENVIRONMENT STORAGE TEMP HUMIDITY 40 80 C 10 95 RH TEMP COEFFICIENT 0 03 C 0 50 C VIBRATION 10 500Hz 2G 10min 1cycle period for 60min each along X Y Z axes SAFETY STANDARDS Design refer to UL1310 Class 2 TUV EN60950 1 CAN CSA C22 2 No 223 M91 EN61347 2 13 IP66 WITHSTAND VOLTAGE 1 P O P 3KVAC SAFETY amp ISOLATION RESISTANCE P O P gt 100M Ohms 500VDC 25 C 70 RH EMC EMI CONDUCTION amp RADIATION Compliance to EN55022 CISPR22 Class B HARMONIC CURRENT Compliance to EN61000 3 2 3 EMS IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 light industry level criteria A MTBF 743 5Khrs min MIL HDBK 217F 25 C OTHERS DIMENSION 148 40 30mm L W H PACKING 0 34Kg 40pcs 14 6Kg 0 63CUFT NOTE 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25C of ambient temperature 2 Ripple amp noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf amp 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 Derating may be needed under low input voltage Please check the derating curve

Download Pdf Manuals

image

Related Search

Related Contents

ms-9200udls 04/23/09 1 engineering specification 198  Paraissait li Hsreredi et lt Samedi à la Gïau-de-Fondi  USR-WIFI232-S/T/G2 USR-WIFI232  instrucciones de servicio - Recicla-Me    ミストファン RLC-MF05    2000 SID Owner's Manual  

Copyright © All rights reserved.