1. OCA enterprise Z Drive PCI Express Storage Solutions ae ay or i Z Drive R4 C Series Solid State Drives KEY DIFFERENTIATORS C Series at a Glance Innovative storage system that melds hardware amp software managed solutions with integrated proprietary technology Cost effective MLC based design with best in class endurance Advanced feature set includes user selectable data recovery amp non stop modes Available in half height and full height configurations The Pinnacle of Storage Performance e Delivers the performance of thousands of hard disk drives in a single server e Eliminates I O and bandwidth bottlenecks Up to 2 800 MB s and 500 000 IOPS per SuperScale controller Proprietary Virtualized Controller Architecture VCA 2 0 e Multifaceted virtualization layer that interfaces with host system e Enables TRIM SCSI Uunmap amp SMART monitoring for system administrators SuperScale Storage Accelerator Unique to OCZ e Facilitates scalable performance in enterprise amp datacenter applications e Unique complex command queuing structure plus queue balancing algorithms e Provides highly efficient performance aggregation while reducing the burden on host resources Superior Reliability Endurance amp Security Features e Data fail recovery ensures superior reliability e Intelligent block management amp wear leveling for increased endurance e Advanced security with 128 bit AES encry
2. OS support service amp Support 3 Year Warranty Dedicated FAE FSE support includes PM engineer support through validation cycle 2011 OCZ Technology Group Inc All rights reserved 7 n i l OCZ Dramatically Accelerating Enterprise Applications The OCZ Z Drive R4 Series represents a turning point in the evolution of PCle attached solid state storage by merging the best feature sets of both the pure hardware and pure software based approaches to data management Designed and manufactured for a wide range of enterprise environments including cloud computing and data centers the Z Drive R4 features OCZ s Virtualized Controller Architecture VCA 2 0 providing the utmost in performance flexibility durability and enhanced reliability allowing data centers to rely on a PCle based SSD as their primary tier one storage solution for the first time Additionally the Z Drive R4 s level of concentrated performance enables system architects to design more productive infrastructures while lowering operating costs associated with hard drive technology enterprise Zor VCA 2 0 supports the industry standard SCSI command set and among a litany of other things provides highly efficient performance aggregation due to our proprietary Complex Command Queuing Structure CCQS that handles balancing with OCZ s unique Queue Balancing Algorithm that extends the NAND flash life at a block level manages redundancy and is the sof
3. up to 2 800 MB s Random Write Operations 4kB 250 000 IOPS 410 000 IOPS Random Write Operations 8kB 160 000 IOPS 275 000 IOPS Maximum IOPS 260 000 IOPS ENVIRONMENTAL Power Consumption Idle 14 5W Active 16 W Idle 23W Active 26 W 500 000 IOPS Operating Temperature OC 0c ONC A016 Storage Temperature 245 C 30 45 C 85 C Airflow Requirement 300 Linear Feet Minute LFM 300 Linear Feet Minute LFM Certifications ROMS CE ECC ROMS CE ECC RELIABILITY SECURITY Data Fail Recovery Recovers data from up to one NAND flash block per NAND controller Data Path Protection ECC Up to 55 bits correctable per 512 byte sector Data path parity protection Data Reliability Read Unrecoverable Bit Error Rate UBER 10e 16 Data Encryption 128 bit AES compliant Product Health Monitoring SMART support COMPATIBILITY PCI Express x8 or x16 slot Fully compliant with the PCI Express Electromechanical Specification Rev PCI Express 2 0 and PCI Express Base Specification Rev 2 0 Windows 7 32 bit 64 bit Windows Server 2003 amp 2008 R2 64 bit Red Hat Enterprise Linux CentOS Operating Systems Oracle Enterprise Linux SUSE Linux Enterprise Server Ubuntu Server and Desktop VMware ESX 5 0 and ESXi 5 0 Power Requirements PCI Express 12V amp 3 3V ADDITIONAL FEATURES Flash Virtualization Layer OCZ VCA Virtualized Controller Architecture 2 0 Performance Optimization TRIM SCSI unmap requires
4. websites referenced in this document The information contained herein is subject to change and may be rendered inaccurate for many reasons including but not limited to any changes in product and or roadmap component and hardware revision changes new model and or product releases software changes firmware changes or the like OCZ assumes no obligation to update or otherwise correct or revise this information OCZ makes no representations or warranties with respect to the contents hereof and assumes no responsibility for any inaccuracies errors or omissions that may appear in this information OCZ specifically disclaims any implied warranties of merchantability or fitness for any particular purpose In no event will OCZ be liable to any person for any direct indirect special or other consequential damages arising from the use of any information contained herein even if OCZ is expressly advised of the possibility of such damages VMware and VMware Ready is a registered trademark or trademark of VMware Inc in the United States and or other jurisdictions Asia Pacific Corporate Office Europe Corporate Office Headquarters Canada Corporate Office 160 Konrad Cres Unit 1 Markham Ontario L3R 9T9 1 905 479 7976 ca_sales oczenterprise com 16F 3 No 700 Chung Cheng Rd Chung Ho City Taipei County Taiwan 235 R O C 886 2 8227 3123 apac_sales oczenterprise com Coenecoop 89B 2741 PH Waddinxveen The Netherlands 31 0 18
5. 2 624020 emea _sales oczenterprise com OCZ Technology Group Inc 6373 San Ignacio Ave San Jose CA 95119 USA 1 408 733 8400 sales oczenterprise com Need a custom solution Contact cemsales oczenterprise com 2011 OCZ Technology Group Inc All rights reserved
6. ption support e Strong error correction for enhanced data integrity Highest performing enterprise PCle solution on the market Merges the best features of pure hardware and software based approaches to data management and overcomes the inherent weaknesses of both Bootable as a direct attach device Ultra high endurance for enterprise applications increases drive life by up to five times the rated P E cycles of the NAND Lowest CPU and memory resource utilization in its class Only PCle drive with complete power fail protection amp drive level recovery R series Maintains user configurable flexibility not found in other enterprise storage devices Only virtualization layer in the industry with TRIM and SCSI unmap support 2011 OCZ Technology Group Inc All rights reserved OCA enterprise PHYSICAL CM84 Version CM88 Version Usable Capacities IDEMA 300GB 600GB 1 2TB 800GB 1 ells 3 21B NAND Components Multi Level Cell MLC Multi Level Cell MLC Interface PCI Express Gen 2 x8 PCI Express Gen 2 x8 Form Factor PCle half height half length compliant PCle full height 3 4 length compliant Storage Controller OCZ SuperScale OCZ SuperScale NAND Controller SandForce 2282 x 4 sandForce 2282 x 8 Dimensions L x W x H 168 55 x 68 91 x 17 14 mm 242 x 98 4 x 17 14 mm Weight 1199 262g PERFORMANCE Max Read up to 2 000 MB s up to 2 800 MB s Max Write up to 2 000 MB s
7. tware interface with the host system Z Drives integrate seamlessly with servers at the system bus and kernel level creating a new flash memory tier and dramatically increasing throughput and application performance all while slashing capital and operating costs CM88 Full Height Form Factor CM84 Half Height Form Factor PRODUCT CARAC ORDERING NAME FORM FACTOR RAW IDEMA WRITE ENDURANCE PART NUMBER UPC Z Drive R4 CM84 Half Height 384GB 300GB Up to 7 5PB ZD4CM84 HH 300G 842024027256 Z Drive R4 CM84 Half Height 768GB 600GB Up to 15PB ZD4CM84 HH 600G 842024027263 Z Drive R4 CM84 Half Height 1536GB 1200GB Up to 30PB ZD4CM84 HH 1 2T 842024027270 Z Drive R4 CM88 Full Height 1024GB 800GB Up to 20PB ZD4CM88 FH 800G 842024027348 Z Drive R4 CM88 Full Height 2048GB 1600GB Up to 40PB ZD4CM88 FH 1 6T 842024027355 Z Drive R4 CM88 Full Height 4096GB 3200GB Up to 80PB ZD4CM88 FH 3 2T 842024027362 OCZ may make changes to specifications and product descriptions at any time without notice The information presented in this document is for informational purposes only and may contain technical inaccuracies omissions and typographical errors Any performance tests and ratings are measured using systems that reflect the approximate performance of OCZ products as measured by those tests Any differences in software or hardware configuration may affect actual performance and OCZ does not control the design or implementation of third party benchmarks or

Download Pdf Manuals

image

Related Search

Related Contents

HERMA Labels Premium A4 63.5x72 mm white paper matt 1200 pcs.  2012年6月号  Polk Audio RTi Series User's Manual  KIP 5000 Series  [U4.52.02] Macro-commande MACRO_MODE_MECA  La page de garde  Borrador PPRL 404 Coordinación de actividades empresariales  PC/II+ & PC/II+i Technical Manual  FAQ for Eee Pad TF201  Accueillir et intégrer des milliers de nouveaux collègues  