Home
LG P03AH air conditioner
Contents
1. 2 4 x 0 75 4 x 0 75 4 x 0 75 4 x 0 75 Max Piping Length Elevation m 15 10 50 30 50 30 50 30 Power Supply V Hz 1 220 240 50 1 220 240 50 1 220 240 50 1 220 240 50 Running Current Cooling Heating A 6 5 5 8 7 5 10 6 10 0 10 7 12 0 13 0 Air Circulation CMM CFM 50 1766 50 1766 58 2048 58 2048 Additional Refrigerant Charge Over 7 5m g m 35 Fuse Sizes Amps 20A EEE LG Inverter e UU12W UUT8W UU24W UU30W Note Due to our policy of innovation some specifications may be changed without notification Pty
2. 3 08 7 7 8 47 3 36 8 4 9 24 Nominal Input Rated Cooling kw 1 25 1 74 2 3 2 68 Power Supply oie 17220 240 0 EER W 2 82 3 03 3 04 2 84 COP W 3 21 3 22 2 81 2 81 WOperational Temperature Cooling C 10 46 10 46 10 46 10 46 Range Heating C 15 24 15 24 15 24 15 24 Air Flow Rate H M L CMM 10 8 3 6 5 13 5 12 11 15 13 5 12 18 16 14 CEM 636 564494 Sound Level H M L dB A 3 45142130 Dehumidification Rate l h 1 2 2 3 3 2 3 5 Dimensions WxHxD Body mm inch 900 200 490 35 4 7 9 19 3 1 200 205 615 47 2 8 1 24 2 1 200 205 615 47 2 8 1 24 2 1 200 205 615 47 2 8 1 24 2 Weight Body kg Ibs 12 26 5 30 66 1 30 66 1 30 66 1 Piping Connections Liquid mm inch 6 35 1 4 6 35 1 4 9 52 3 8 9 52 3 8 Gas mm inch 9 52 3 8 12 7 1 2 15 88 5 8 15 88 5 8 Autochangeover operation is not available in UV12 NEC Outdoor Unit UU12W UEC UU18W UEC Compressor Type e Scroll e Scroll Rotary Rotary Refrigerant Charge Charge g 0z 1100 40 1500 52 91 2000 70 6 2000 70 6 Type R410A R410A R410A R410A Fan Discharge Side Top Side Discharge Side Discharge Side Discharge Side Discharge Noise Level H L Sound Press im dB A 3 51 45 51 45 52 46 52 46 Dimensions W H D mm inch 870 655 320 34 3 25 8 12 6 870 655 320 34 3 25 8 12 6 870 808 320 34 3 31 8 12 6 870 1060 320 34 3 41 7 12 6 Net Weight Outdoor kg Ibs 46 101 52 114 6 60 132 60 132 Ges mm inch 15 88 6 8 Interunit Cable Includes earth No mm
3. floor standing This is a floor standing type that blends in perfectly with the surrounding decoration Clean and fresh air conditioning is ensured with a high level of cooling or heating performance and air purifying operation PLASMA Air Purifying System The PLASMA Air Purifying System within the air conditioner removes microscopic contaminants and dust to eliminate offensive odors and prevent allergic reactions It can also be used as an air purifying unit even though the ailr cooling function is off Dust electrode discharge Dust particles lonizer Photo Catalyst Coated Mesh V q1 4 arg w 3 AN h o Polluted Air ve nS Ih NN A 1 i WV i i Odour molecule Odour Dust Reduction Respirable particles from 5 cigarettes in a sealed room removed by LG Plasma Air Purifying System Deodorization LG s Plasma unit effectively removes high concentration tobacco odors confirmed in Sensory tests of odor index carried out in Korea and Japan ERIS l l Anti Allergy In clinical tests the plasma unit has earned a satisfaction ratio of 82 Evaluated by CSIRO Australia DBCE Doc 98 204 Tested by Korean Food Research Institute and Japanese Environmental Centre and Yonsei Univ College of Medicine Allergy Research Lab Note Due to our policy of innovation some specifications may be changed without notification Generating plasma Anti Bacteria Filter It removes dust in the air as well a
4. ontrol etc eV Ty fat Gold Fin Anti Corrosion LG s Outdoor Heat Exchanger is coated with a golden anti corrosive epoxy treatment on the aluminum coil to minimized corrosion This maintains heat transfer properties of the coil for an extended time where as non Gold Fin coils progressively lose efficiency due to surface corrosion Standard on every LG air conditioner this assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt Airflow Direction Control Horizontal Airflow Direction Control Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand Vertical Airflow Direction Control The airflow direction can be adjusted as desired by using the remote controller Horizontal Downward celling amp TOOK Dc Inverter UV12 UV18 UV24 UV30 UV18 UV30 O ie od E Ko O Specification Indoor Unit UV12 NEC UV18 NBC UV30 NBD UV24 NBD Nominal Capacity Rated Cooling Btu h 4 800 12 000 13 200 7 200 18 000 19 800 9 553 23 884 26 272 10 373 25 932 28 525 kw 1 40 3 52 3 87 2 11 5 28 5 81 2 8 7 0 7 7 3 04 7 6 8 36 Heating Btu h 5 520 13 800 15 180 8 120 20 300 22 330 10 509 26 274 28 901 11 464 28 662 31 528 kw 1 62 4 04 4 44 2 38 5 95 6 54
5. s bacteria proliferation making the indoor atmosphere healthy 4 Way Auto Swing PO3AH Hot or cold air can be evenly distributed throughout the room as the auto swing function blows air in 4 directions Sis Se TUNUOUIPTNNNED Dooni SET 1O TURSOZ Child Lock Function This function prevents children or others from tampering with the control buttons on the unit It is then controlled by the remote controller All the buttons on indoor display panel will blocked The unit will be controlled only by remote controller Duct Operation PO8AH only Depending on the room size and shape if the unit is installed in a Duct type manner you are able to cool more air at the same time to save energy O C a op O c floor standing PO3AH POSAH Z O OQ f i 2 See Specification Indoor Unit PO3AH SRI1 PO5AH STO Cooling Btu h 27 800 46 000 8 140 13 480 Ww Heating Btu h 27 800 48 000 Ww 8 140 14 060 Input Cooling WwW 2800 5300 Ww Capacity Heating 5000 E E R Cooling W W 2 540 C O P Heating W W 2 810 Running Current Cooling 9 5 A 13 Operational Temperature Cooling C 5 46 5 46 Range Outdoor Heating C 10 24 15 24 Air Flow Rate H M L CMM CFM 18 16 13 636 565 459 30 26 23 1 060 918 812 Noise Level Sound Press 1m H M L dB A 3 48 46 40 53 51 48 Dehumidifica
6. tion Rate I h 6 0 3 3 Dimensions W H D Indoor inch mm 22 4 71 7 12 5 570 1820 317 23 2 72 8 17 3 590 1850 440 Net Weight Indoor kg Ibs 33 73 60 132 Refrigerant Charge Charge g oz 2200 77 6 at 7 5m 2900 102 3 at 7 5m Type R410A R410A Noise Level Sound Press 1m Outdoor dB A 3 58 58 Dimensions Outdoor W H D inch mm 34 25 25 79 12 6 870 655 370 30 3 21 3 10 770 540 245 Net Weight Outdoor kg Ibs 63 139 90 198 Pipe Connection Liquid inch mm 3 8 9 52 3 8 9 52 Gas inch mm 5 8 15 88 3 4 19 05 Max Piping Length Elevation m 30 20 40 25 Note Due to our policy of innovation some specifications may be changed without notification PO3AH POSAH O D QO e O oJ U C U D D _ ok D ok celling amp floor ceiling Suspended Floor Ceiling Convertible System has the flexibility of multiple installations The Indoor Unit can easily be mounted on the floor or Suspended from the ceiling The Convertible System features Gold Fin protection on the Outdoor Unit amp Energy saving Plasma Heat Exchanger in the Indoor Unit Compact Size A am L 1350x650x220 36K oe ee i a e 1750x650x220 48 60K Weight 65kg 35kg Volume 100 68 Upgraded Function e One Touch Filter amp Filter Cleaning Alarm Function e Power Wind Mode e Wired Remote Controller Option UV18 UV6O0 available Weekly Program Group c
Download Pdf Manuals
Related Search
Related Contents
48-980型 取扱説明書 保証書付 樹脂管用温水コンセント〔スリーブ型〕 Toma de carga USB 230 V Instrucciones de servicio y de montaje 1 Bedienungsanleitung HICO DECUBIMAT 370 Diamond Multimedia R9280XD53GXOC AMD Radeon R9 280X 3GB graphics card HVT-BCT300 取扱説明書 .GSD Announces.. . New Prices for HP 2000 FY301MP. Gas-Powered Pressure Washer MOVITRANS® TPM12B Mobile Converter / Instruções de Operação Copyright © All rights reserved.
Failed to retrieve file