Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial

image

Contents

1. 3U sold separately The SU1000XLCD has 6 5 15R outlets including 2 single outlet load banks that are individually controllable to reboot select equipment on demand or maximize battery runtime for mission critical equipment USB and DB9 communication ports support messaging of detailed UPS operational parameters and line power status Included PowerAlert power management software supports an unlimited number of network UPS systems The SU1000XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network It comes backed by a 2 year warranty and 250 000 of Ultimate Lifetime Insurance U S Canada and Puerto Rico only Features Ideal for Protection of Mission Critical Equipment The SU1000XLCD provides true on line operation reliable battery backup and comprehensive power management capability in a compact tower form factor Featuring a 1000VA 900W capacity 6 5 15R outlets a 10 ft cord with standard 5 15P plug USB DB9 ports and a slot for an optional SNUPWEBCARD the SU1000XLCD offers a complete power protection solution for small to medium size servers storage devices telecom systems and other mission critical equipment True On Line Operation with Pure Sine Wave Output and Zero Transfer Time The SU1000XLCD provides the highest level of protection available for mission critical equipment It actively converts raw incoming AC power to DC then re converts it back to regulated filtered
2. AC output with a pure sine wave completely isolating connected components from all power problems Zero transfer time between AC and battery operation maintains continuous output and further protects connected equipment from the disruptive effects of blackouts and severe low voltage conditions Sine wave output guarantees compatibility with all equipment types 1 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Individually Controllable Outlets The SU1000XLCD includes 2 single outlet load banks that are individually controllable via a software interface for remote reboot of locked up equipment or load shedding to maximize battery backup time for mission critical equipment Reliable Expandable Battery Backup UPS battery backup keeps connected equipment operational through short power failures and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout The SU1000XLCD features a large internal battery set that provides 12 8 minutes of battery support for a half load 450 watts and 3 8 minutes for a full load 900 watts During normal operation incoming utility power keeps the UPS battery fully charged so that backup power will always be available if needed For mission critical applications demanding continuous uptime the fully scalable SU1000XLCD can provide expandable runtime with optional external battery packs Tripp Lite model BP24V15RT2
3. Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS AC Suppression Joule Rating 570 UPS AC Suppression Response Instantaneous Time UPS Dataline Suppression 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet EMI RFI AC Noise Suppression Yes PHYSICAL Installation Form Factors Supported o o o o wiih iicluded Acces ores 2 output voltage regulation during undervoltages to 55V 33 load 70V 70 load 100V 100 load ON LINE MODE Maximum output capacity rating is reduced to 810W at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion Installation Form Factors Supported mode 127 120 115 110V 630 watts 100V 567 watts OVERLOAD CAPACITY Supports inverter operation up to with Optional Accessories 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Primary Form Factor Tower UPS Power Module Dimensions hwd in 10 x 6 8 x 13 2 UPS Power Module Dimensions hwd cm 254x 17 1x 33 7 Stepdown Transformer Dimensions hwd in Stepdown Transformer Dimensions hwd cm Included Battery Pack Dimensions hwd in Included Battery Pack Dimensions hwd cm UPS Shipping Dimension
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 100 127V 1kVA 900W On Line Highlights Double Conversion UPS Extended Run SNMP gets a eee eg Webcard Tower LCD display USB DB9 Serial Se eka ne Te MODEL NUMBER SU1000XLCD output high efficiency economy mode option e Interactive LCD with 10 selectable screens of UPS and site power data e Expandable runtime Hot swappable batteries e USB RS232 amp EPO ports SNMPWEBCARD option e 2 independently switched load banks e NEMA 5 15P input 6 5 15R outlets Package Includes e SU1000XLCD SmartOnline Tower UPS System e PowerAlert Software CD and Description Do you need to protect small to medium size servers networking equipment and telecom systems against data loss downtime and equipment damage due to power outages voltage fluctuations and transient surges Tripp Cabling Lite s SU1000XLCD SmartOnline Tower UPS System is the solution Featuring a 1O00VA 900W capacity and e Emergency Power Off EPO true on line operation with pure sine wave output and Zero transfer time to battery it provides the highest level of caning power protection for mission critical equipment The SU1000XLCD s large internal battery set supports Gr ne ieee connected equipment during blackouts and runtime is expandable with optional external battery packs Tripp Lite model BP24V15RT2U BP24V28 2U or BP24V70
5. U BP24V28 2U or BP24V70 3U sold separately High Power Factor and Highly Efficient Operation Reduces BTU Output The SU1000XLCD features a high 0 9 power factor and an optional highly efficient economy mode setting that can significantly reduce a facility s energy costs In economy mode the UPS operates with 96 efficiency minimizing heat output reducing cooling requirements and consuming less electricity AC Line and Tel Ethernet Surge Suppression A sudden power surge or spike can damage or destroy electronic components and wipe out irreplaceable data The SU1000XLCD features a 570 joule surge suppression rating to protect connected components and data from the harmful effects of power surges One set of tel Ethernet RJ45 jacks provides surge protection for a standard phone or network connection cable not included EMI RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line This line noise is a common cause of incremental hardware damage data corruption and audio video performance problems The SU1000XLCD incorporates technology that filters out disruptive line noise preventing it from affecting your equipment LCD Screen and Audible Alarm The SU1000XLCD features a front panel LCD screen that enables IT personnel to monitor line power on line mode bypass mode on battery overload battery low replace battery and fault status information It is supplemented by an audible alar
6. ing is reduced to 810W at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion UPS Output Receptacles Surge mode 127 120 115 110V 630 watts 100V 567 watts OVERLOAD CAPACITY Supports inverter operation up to Suppression Only 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Load Management Receptacles Two switchable single outlet 5 15R load banks Output AC Waveform AC Mode Pure Sine wave Output AC Waveform Battery Mode Pure Sine wave INPUT Rated input current Maximum Load 10A Nominal Input Voltage s Supported 100V AC 110V AC 120V AC 127V AC Tripp Lite ERRON 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Nominal Input Voltage Description 120V factory default UPS Input Connection Type 5 15P UPS Input Cord Length ft Recommended Electrical Service 15A 120V Input Phase Single Phase BATTERY Full Load Runtime min 3 8 min 900w Half Load Runtime min 12 8 min 450w Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP24V15RT2U limit 1 BP24V28 2U limit 1 BP24V70 3U multi pack compa
7. m that signals UPS startup power failure low battery overload UPS fault and remote shutdown conditions USB DB9 Ports SNMP Capability and Included PowerAlert Software The SU1000XLCD features an HID enabled USB port and a DB9 port cables included Used with Tripp Lite s included PowerAlert software these communication ports provide comprehensive network power monitoring and control Capabilities include UPS and line power status messaging on battery low battery power restored AC line voltage DC battery voltage and remaining battery capacity timed inverter shutoff after unattended shutdown and UPS output power control for delayed or immediate reboot of connected devices The SU1000XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network Emergency Power Off EPO Capability The SU1000XLCD features an EPO interface port that supports emergency shutoff in large facilities cable included Peace of Mind The SU1000XLCD comes with 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only for connected equipment and a 2 year warranty 2 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Specifications OUTPUT ON LINE MODE Maximum output capacity rating is reduced to 810W at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conve
8. pass Hot swappable batteries Green Energy Saving Features i e daa mode operation Individually controllable load banks Schedulable daily hours of economy CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category B EMI WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6
9. rsion Output Capacity Details mode 127 120 115 110V 630 watts 100V 567 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Nominal Output Voltage s 100V 110V 120V 127V Supported l Nominal Voltage Details 120V default Frequency Compatibility 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion ON LINE MODE Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz BATTERY MODE Output is regulated to 0 05Hz of selected nominal Frequency Compatibility Details Output Voltage Regulation Line 2 Mode Output Voltage Regulation 10 Economy Line Mode Output Voltage Regulation Battery 3 Mode Output Receptacles 6 5 15R ON LINE MODE Maximum output capacity rat
10. s hwd in 14 2 x 10 x 18 5 UPS Shipping Dimensions hwd 36 2 x 25 4 x 47 Cooling Method Fan ENVIRONMENTAL 0 to 95 non condensing AC Economy Mode BTU Hr Full 23 Load 1 Battery Mode BTU Hr Full Load 585 O 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com AC Mode Efficiency Rating 100 o Load oe AC Economy Mode Efficiency Rating 96 100 Load Audible Noise lt 50 dB at front side 1m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications PowerAlert Software Included Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time Zero transfer time 0 ms in online double conversion and frequency regulation conversion modes Low Voltage Transfer to Battery 55V 33 load 70V 70 load 100V 100 load Power Setpoint High Voltage Transfer to Battery 150 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode g During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter by
11. tible DC System Voltage VDC Expandable Runtime Description leila configurations require the use of Tripp Lite s External Battery Configuration Software see manual Battery Recharge Rate Included Batteries Internal UPS Replacement Battery RBC24V LCD Cartridge Battery Access Battery access door Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Overvoltage Correction 2 output voltage regulation during overvoltages to 150 Undervoltage Correction 2 output voltage regulation during undervoltages to 55V 33 load 70V 70 load 100V 100 load USER INTERFACE ALERTS amp CONTROLS Front Panel LCD Displa Front panel LCD information and configuration screen offers detailed UPS and site power status and operating y data plus configuration of voltage frequency operating mode alarm function and a variety of additional options 2 switches control off on power status and alarm cancel self test operation Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option Less than 3 hours from 10 to 90 typical full load discharge Alarm Cancel Operation available Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions SURGE NOISE SUPPRESSION 416 Tripp Lite ieee YY 35th