Home

Cisco Broadcom 5709 2-port 1Gb

image

Contents

1. F2 F1 E2 E1 331707 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 59 SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server you should consider the following items B Each channel has two DIMM slots for example channel A slots A1 and 2 Achannel can operate with one or two DIMMs installed Jjfachannel has only one DIMM populate slot 1 first the blue slot B When both CPUs are installed populate the DIMM slots of each CPU identically Fill blue slots in the channels first A1 E1 B1 F1 C1 G1 D1 H1 Fill black slots in the channels second A2 E2 B2 F2 C2 G2 D2 H2 B Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized B Observe the DIMM mixing rules shown in Table 31 Table 31 DIMM Rules for C220 M3 Servers DIMM Parameter DIMM Capacity RDIMM 4 8 or 16 GB LRDIMM 32 UDIMM 4 GB DIMM Speed 1866 1600 or 1333 MHZ DIMM Type RDIMMs LRDIMMs or UDIM
2. E FAN 06000 C Oss eO rd ES e O 20990 05000 05000 T OO000 0065 00000 05000 SEES WR FAN3 Ose sd t i g ES 90900 05600 05000 GOD FAN4 0060 05000 99900 00000 Oss e ES e E 5 foley ele Reisen g 7 GOOD SOOO PSU1 0060 05000 05000 99900 00000 331714 2 502 socket SuperCap module mounting location 78 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 39 UCS C220 M3 Dimensions and Weight Parameter Height Width Depth Front Clearance Side Clearance Rear Clearance Weight Value 1 7 in 4 32 cm 16 92 in 43 0 cm 28 5 in 72 4cm 3 in 76 mm 1 in 25 mm 6 in 152 mm Maximum 8 HDDs 2 CPUs 16 DIMMs 2 power supplies 35 6 lbs 16 2 kg Minimum 1 HDD 1 CPU 1 DIMM 1 power supply 26 8 lbs 12 1 kg Bare 0 HDD 0 CPU 0 DIMM 1 power supply 22 lbs
3. C15M EN60320 C15 CAB 9K10A SW Power Cord 250VAC 10A MP232 Plug Switzerland Cordset rating 10 A 250 V Z X Length 8 ft 2 in 2 5 m Connector IEC 60320 C15 CAB 9K10A UK Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK Cordset A SN L EL 210 EN _ BS 13634 13 fuse 9 12 Power Cord 125VAC 13A 5 15 Plug North America il CAB 250V 10A BR Power Cord 250V 10A Brazil EZ uu hea Tw Quos ig h CAB JPN 3PIN Power Cord 3PIN Japan Image not available Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 41 CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management Use Table 17 to order a cable management arm Table 17 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C220 rack servers For more information about the cable man
4. Total DIMMs 4x8 GB 4x4 GB 4x8 GB 4x4 GB 4 8 4 8 4 8 4 8 1866 4 16 4 16 1866 4 16 2 16 4 16 2 16 1866 NM 4x16 GB 4x8 GB 4x16 GB 4x8 GB 1866 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1866 62 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Table 33 Recommended Memory Configurations for Intel Xeon E5 2600 v2 CPUs with 1600 and 1866 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs DIMM Max Blue Slots Black Slots Blue Slots Black Slots Speed MH Total DIMMs Bank 1 Bank 2 Bank 1 Bank 2 peed MHz 1 1 C1 D1 A2 B2 C2 D2 1 1 G1 H1 E2 F2 G2 H2 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1866 Notes 1 Rows marked in yellow indicate best performance 2 1866 MHz 4 GB DIMMs are not offered 3 32 GB LRDIMMs run in some cases at a maximum speed of 1333 MHz in 2DPC configurations even though the specified DIMM speed is higher Table 34 Recommended Memory Configurations for Intel Xeon E5 2600 CPUs with 1600 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs Total 270591 Black Slots Blue Slots Black Slots Bank 2 Bank 1 Bank 2 Speed MHz Size Bank 1 E2 F2 A1 B1 C1 D1 A2 B2 C2 D2 E1 F1 G1 H1 G2 H2 4 16 4 16 16
5. Embedded Mezz Internal Internal External Drives PCle RAID PCle PCle 1 CPUs RAID RAID 12 RAID 23 RAIDA Supported Server PCle Slots Not Not Not Not Installed C220 M3 SFF 1 slot 1 MU Nm 8 internal U default Not Not Not Not Installed 240 cz20 M3 SFF 1 auowed allowed allowed allowed oti edema Y oe Installed C220 M3 SFF slot 2 8 internal PUT MSN default Installed Not 240 C220 SFF 2 slot 1 or external slot 2 n Not Not 8 internal C220 M3 SFF 2 slot 1 or 240 allowed allowed slot 2 Notes 1 Never disable OPROM for the mezzanine slot if the mezzanine card is present or the system will not boot If you remove the mezzanine card and disable its OPROM you can boot from another bootable device RAID card embedded RAID or from SAN via an HBA or CNA card When you boot from a device make sure its OPROM is enabled it is in the proper boot sequence and its BIOS is configured for a bootable device If you want to boot from a device other than the 9271 8i or 9271CV 8i MegaRAID PCle card you can leave the card installed Just disable the OPROM for its slot and the system will boot even with the card installed Dual RAID controllers are not supported in this server External RAID card is the 9285CV 8e or 9286CV 8e Any of these can be installed simultaneously with one
6. Product ID PID PID Description Card Height Converged Network Adapters CNAs UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA Half UCSC PCIE C10T 02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half UCSC PCIE C40Q 02 Cisco VIC 1285 Dual Port 40 Gb QSFP CNA Half UCSC PCIE ESFP Emulex 11102 dual port 10 GbE FCoE CNA Gen 3 CNA Half UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP Half UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Half Network Interface Cards NICs N2XX ABPCIO1 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCIO3 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AIPCIO1 Intel X520 Dual Port 10Gb SFP Adapter Half UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter Half UCSC PCIE IRJ45 Intel 1350 Quad Port 1Gb Adapter Half UCSC PCIE BTG Broadcom 57712 Dual Port 10GBASE T w TOE iSCSI Half Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half N2XX AEPCIO5 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX AQPCIO3 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics Half Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 31 CONFIGURING the SERVER Table 11 Available PCle Option Cards continued Product ID PID PID Description Card H
7. F and H Each DIMM channel has two banks bank 1 and bank 2 The blue colored DIMM slots are for bank 1 and the black colored slots are for bank 2 As an example DIMM slots A1 B1 C1 and D1 belong to bank 1 while A2 B2 C2 and D2 belong to bank 2 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B C and D are associated with CPU1 while the DIMM slots on the left channels E F G and H are associated with CPU2 The bank 1 blue DIMM slots are always located farther away from a CPU than the corresponding bank 2 black slots Bank 1 slots blue are populated before bank 2 slots black 58 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks CIT 2 m 8 D1 D2 B2 B1 A2 A1 G1 G2 H1 H2 JO JUOIS
8. 16 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The available memory DIMMs and mirroring option are listed in Table 4 Q NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Available DDR3 DIMMs Product ID PID PID Description Voltage jaa DIMM Optionst 0000000000000 UCS ML 1X324RY A 32 DDR3 1600 MHz LR DIMM PC3 12800 4R x4 1 35v 1 5 1 35 V2 4 UCS ML 1X324RZ A 32 GB DDR3 1866 MHz LR DIMM PC3 14900 4R 4x 1 5v 1 5 V 4 UCS MR 1X162RY A 16 GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35v 1 5 1 35 V 2 UCS MR 1X162RZ A 16 GB DDR3 1866 MHz PC3 14900 2R x4 1 5 V 2 UCS MR 1X082RY A 8 GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35v 1 5 1 35 V 2 UCS MR 1X
9. Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 71 SUPPLEMENTAL MATERIAL CPU Removal and Installation pick n place Tool Set The Pick n Place tool set includes two tools B Pick and pull cap tool used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it B Pick and place tool used to install a CPU in its socket without damage Must be used each time a CPU is installed in a UCS M3 server Instructions for using this tool set are found at the following link http www cisco com en US docs unified computing ucs c hw C220 install replace html wp1233864 NOTE When you purchase spare CPU the Pick Place Toolkit is included Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com en US docs unified computing ucs c hw C220 install replace html wp1233864 4 gt CAUTION Use only the thermal grease specified for this server UCS CPU GREASE2 This thermal grease comes in a red tipped syringe and is to be used only in the C220 M3 and C240 M3 servers Other servers use thermal grease in a blue tipped syringe UCS CPU GREASE Thermal grease for other systems may have different thermal conductivity properties and
10. mezzanine RAID controller card They cannot be used simultaneously with an internal RAID controller card 9271 8i or 9271CV 8i because of mounting space limitations for the supercap there is space to mount only one supercap available slot occupied slot unsupported slot slot 2 is not supported in 1 CPU systems The mezzanine slot is not supported in 1 CPU systems Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 27 CONFIGURING the SERVER 28 Caveats B Note that only a single Cisco VIC card the half height Cisco VIC 1225 and 1285 PCle card is supported and it must be installed in the full height PCle slot slot 1 on riser 1 So take this into account when populating RAID controller cards B You can choose an optional RAID configuration RAID 0 1 5 6 10 which is preconfigured at the factory The RAID level you choose must be an available RAID choice for the controller selected RAID levels 50 and 60 are supported although they are not available as configuration options NOTE RAID for the external RAID controllers LSI MegaRAID SAS 9286CV e and LSI MegaRAID SAS 9285CV e is not factory configured NOTE For more important information regarding RAID combinations and support see RAID Details page 67 and RAID Option ROM OPROM Settings page 68 o Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Mo
11. 10 kg Power Specifications The general power specifications for the C220 M3 SFF server 450 W AC power supply are listed in Table 40 Table 40 UCS C220 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for each power supply 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal Range 47 to 63 Hz single phase 50 to 60 Hz nominal 6 0 A peak at 100 VAC 3 0 A peak at 208 VAC 11 A 450 W Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 79 TECHNICAL SPECIFICATIONS Table 40 UCS C220 M3 SFF 450 W Power Supply Specifications continued Description Specification Power supply output voltage Power supply efficiency Main power 12 VDC Standby power 12 VDC CSCI Platinum NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet The general power specifications for the C220 M3 SFF server 650 W power supply are listed in Table 41 Table 41 UCS C220 M3 SFF 650 W AC Power Supply Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for the power supply Power supply output voltage Power supply efficiency 90 to 264 VAC self ranging 100
12. OPTIONAL 44 13 ORDER OPTIONAL USB 2 0 DRIVE 45 14 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE 46 15 SELECT OPERATING SYSTEM MEDIA KIT 49 16 SELECT SERVICE and SUPPORT LEVEL 50 OPTIONAL STEP ORDER RACK s 55 OPTIONAL STEP ORDER PDU 900 SUPPLEMENTAL MATERIAL 97 CHASSIS 26 9 Goa Geet Bee ee eee oe bes Peo ee Oe eee es 57 CPUS and DIMMS XE dU Oe S OD EERE OOS oe ee 58 PRVSICAULAVOUU 4 95 9 8 9 3 3 5 3 See E 3 8 9 9 eee es 58 Memory Population Rules 60 DIMM Population 61 Recommended Memory Configuration 62 Additional DIMM Populations 65 Low Voltage DIMM lt 1 5 66 PAID DOLIG 2225 3099 9 eee eee ee eee ease eee 67 RAID Option ROM OPROM Settings 68 Sella MCCC 69 Upgrade and Servicing Related 70 Drive Blanking Panels 71 Upgrading your Server from Intel Xeon E5 2600 to Intel Xe
13. These PCle flash storage devices provide independent high speed storage The server supports up to two internal 32 GB Cisco Flexible Flash drives SD cards The second SD card is blank and can be used to mirror the first SD card It can be used to protect the Hypervisor Partition with RAID1 8 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Video The Emulex Pilot 3 Integrated Baseboard Management Controller provides video m Matrox G200e video controller B integrated 2D graphics core with hardware acceleration B Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz 24 bit color depth for all resolutions less than 1600x1200 B 8 MB video memory Storage controller m Embedded RAID 3 Gbs e Embedded SATA only RAID controller supporting up to 4 SATA only drives RAID 0 1 10 or e ROM5 embedded RAID upgrade supporting up to 8 SAS SATA drives RAID 0 1 10 or e ROM55 embedded RAID upgrade supporting up to 8 SAS SATA drives RAID 0 1 5 10 m 2008M 8i Mezzanine Cards 6 Gbs two versions e Cisco UCSC RAID SAS 2008M 8i Mezzanine Card supporting up to 8 SAS SATA drives supporting RAID 0 1 5 10 and 50 SAS and SATA drives can be mixed This card has a product ID PID of UCSC RAID 11 C220 e Cisco UCSC RAID SAS 2008 81 Mezzanine Card supporting u
14. connector used with cable that provides two USB one and one serial connector ii Temperature status LED Drives to eight hot swappable 2 5 inch drives For more information about the KVM cable connection see KVM CABLE page 77 6 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel Figure 3 Chassis Rear View 0 9 331683 BEA n ORNS Power supplies up to two One 10 100 1000 Ethernet dedicated management port Slot 2 Low profile PCle slot on riser Dual 1 GbE ports half height half length x16 connector x8 LAN1 and LAN2 lane width Slot 1 Standard profile PCle slot on riser USB ports full height half length x24 connector x16 lane width supports Cisco Virtual Interface Card VIC LN VGA video connector Rear Identification button LED DMLCCIIIL Notes 1 For details of the serial port pinout see Serial Port Details page 69 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 7 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure
15. offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU See Figure 11 Figure 11 Zero Rack Unit PDU PID RP208 30 2P U 2 C13 plugs ra Breakers C19 plugs Ground connection Cisco RP Series PDU models provide two 20 ampere A circuit breakers for groups of receptacles The effects of a tripped circuit are limited to a receptacle group Simply press a button to reset that circuit 76 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 38 Table 38 KVM Cab
16. Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER You can choose a service listed in Table 27 Table 27 UCS Computing Combined Support Service Service On T Product ID PID Level GSP Site Description QON NCF2 C220M3SF No CMB SPT SVC 24X7X2 UCS C220 M3 SFF CON NCF2P C220M3SF NCF2P Yes CMB SPT SVC 24X7X20S UCS C220 SFF CON NCF4P C220M3SF Yes CMB SPT SVC 24 7 40 UCS C220 SFF QON NCFA4S C220M3SF 45 Yes CMB SPT SVC 8X5X4OS UCS C220 SFF CON NCFCS C220M3SF Yes CMB SPT SVC 8X5XNBDOS UCS C220 M3 SFF CON NCFE C220M3SF NCFE No CMB SPT SVC 8X5X4 UCS C220 SFF CON NCFP C220M3SF CMB SPT SVC 24 7 4 UCS C220 SFF CON NCFT C220M3SF NCFT NO CMB SPT SVC 8X5XNBD UCS C220 M3 SFF Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that
17. Description N20 BBLKD 2 5 inch HDD Blanking Panel UCSC CABLE1 Set of two 2 SAS SATA Cables for C220 M3 SFF 2 5 in UCSC PCIF 01H PCle Low Profile blanking panel for UCS C Series Server UCSC PCIF 01F PCle Full Height blanking panel for UCS C Series Server UCSC HS C220M3 Heat Sink for UCS C220 Rack Server UCS CPU LPCVR CPU load plate dust cover for unpopulated CPU sockets UCSC AIRBAF C220 Air Baffle Replacement Kit for C220 Server N20 MBLIBAT T Replacement Lithium Battery for Server Motherboard 2032 UCS RAID BBU Battery Back Up for 92662 CAUTION If one of your RAID cards is equipped with a i battery backup unit BBU be aware that hot swapping the BBU is not supported Please perform a graceful shutdown of the server prior to replacing the BBU UCS RAID CV SC LSI CacheVault Power Module for 9266CV 8i 9271CV 8i 9285CV 8e and 9286CV 8e UCSC PSU BLKP Power supply blanking panel filler for C Series Servers UCSC CMA1 Reversible Cable Management Arm for C220 rack servers UCSC RAIL1 Rail Kit for C220 rack servers UCSC RAIL1 1 Inner rail spare for C2204 UCS SD 32G S Blank SD Card for UCS servers UCS USBFLSH S 4GB 4GB SLC Flash USB Drive shorter for all servers except C260 N20 BKVM KVM local IO cable for UCS servers console port UCS CPU EP PNP Pick n place CPU tools for M3 EP 10 8 6 4 2 core CPUs Green 70 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor D
18. Memory Speeds 1333 MHz Capable CPU 1600 MHz Capable CPU 1866 MHz Capable CPU RDIMM RDIMM RDIMM DIMM DPC DR SR DR SR DR SR Speed 1 3 V L5V 13 1 5V 13V 15V 1 3 1 5 13V 1 5V 1 3V 1 5 1333 1333 LRDIMM LRDIMM Voltage Voltage Voltage 1333 1DPC 1333 1333 1333 1333 DIMM 2DPC 1333 1333 1333 1333 1333 1333 1600 1DPC 1333 1333 1600 1600 1600 1600 gag 10 1333 NA 1333 1600 1600 1866 1866 DIMM 55pc was 1333 1333 1600 1600 1866 1866 Notes 1 These DIMMs operate at 1333 MHz instead of 1600 MHz when used with any E5 2600 CPUs They operate at 1600 MHz when used with E5 2600 v2 CPUs that support 1600 and 1866 MHz speeds 2 1866 MHz DIMMs are only offered and supported with E5 2600 v2 CPU configured servers 3 not applicable B For optimum performance do not mix DIMMs with different frequencies If you mix DIMM frequencies the system defaults to the lower frequency Do not mix RDIMMs LRDIMMs or UDIMMs DIMMs for CPU 1 and CPU 2 when populated must always be configured identically The server supports 1 or 2 DIMMs per channel for single or dual rank RDIMMs The server supports 1 or 2 DIMMs per channel for quad rank LRDIMMs When using mirroring DIMMs must be installed in identical pairs across paired DDR3 buses That is mirrored pairs in channels A and B must be ident
19. NBD onsite parts replacement eight hours a day five days a week 90 day software warranty on media Ongoing downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards SMART net for UCS For support of the entire Unified Computing System Cisco offers the Cisco SMARTnet for UCS Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 23 Table 23 Cisco SMARTnet for UCS Service Product ID PID On Site Description CON PREM C220M3SF Yes ONSITE 24
20. One mezzanine RAID controller for internal drives or One RAID controller for external drives or One RAID controller for internal drives or One mezzanine RAID controller for internal drives and one RAID controller for external drives NOTE For all valid combinations of embedded RAID mezzanine and internal external RAID controller combinations see RAID Details page 67 Table 6 Available Embedded RAID Options Product ID PID PID Description RAID Controllers UCSC RAID ROM5 Onboard RAID consisting of a plug in storage controller unit SCU supporting up to 8 internal SAS SATA drives SAS and SATA drives can be mixed This option supports RAID 0 1 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support UCSC RAID ROM55 Onboard RAID consisting of two plug in modules an SCU plus a software key module supporting up to 8 internal SAS SATA drives SAS and SATA drives can be mixed This option supports RAID 0 1 5 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support NOTE VMware ESX ESXi any other virtualized environments are not supported e for use with the embedded MegaRAID controller Hypervisors such as Hyper V Xen or bm KVM are also not supported for use with the embedded MegaRAID controller Table 7 Available Mezzanine Card RAID Options Product ID PID PID Description Me
21. Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required BMC BPPM Per Server BMC BladeLogic Standard Edition 4 Cores Support Required BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BMC BladeLogic Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Over half off N1K and VSG w purchase of UCS B C Series Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 47 CONFIGURING the SERVER Table 21 OSs and Value Added Software for 2 CPU servers continued PID Description VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW
22. This part is included configured with the server chassis This part is included with the purchase of each optional or spare Intel Xeon E5 2600 CPU processor kit This part is included with the purchase of each optional or spare Intel Xeon E5 2600 v2 CPU processor kit CON OD OFF Drive Blanking Panels A drive blanking panel N20 BBLKD must be installed if you remove a disk drive from a UCS server These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Upgrading your Server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs or downgrading from Intel Xeon E5 2600 v2 to Intel Xeon E5 2600 CPUs See the following link http www cisco com en US docs unified_ computing ucs hw CPU IVB install IVB B html Adding an Additional CPU with CPU heat sink All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU and heat sink can be found at the following link http www cisco com en US docs unified_ computing ucs c hw C220 install replace html wp1233864 Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com en US docs unified_computing ucs c hw C220 install replace html wp1235772
23. may cause overheating if used in the C220 M3 or C240 M3 servers DO NOT use thermal grease available for purchase at any commercial electronics store If these instructions are not followed the CPU may overheat and be destroyed NOTE When purchase spare CPU the thermal grease with syringe applicator is included Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the air baffles needed for one UCS C220 M3 server 72 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified computing ucs c hw C220 install replace html wp1233864 NOTE When you purchase a spare CPU the CPU cleaning is included Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 73 SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 10 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment B Cisco UCS B Seri
24. 00 pw ww 4 cow c Cisco UCS Cisco 5 C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 63 Total DIMMs SUPPLEMENTAL MATERIAL Table 34 Recommended Memory Configurations for Intel Xeon E5 2600 CPUs with 1600 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs Blue Black Slots Blue Slots Black Slots DIMM Max Bank 2 Bank 1 Slots Bank 2 Speed MHz Total DIMMs Bank 1 E2 F2 1 1 C1 D1 G2 H2 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1333 Notes 1 Rows marked in yellow indicate best performance 2 32 GB LRDIMMs run in some cases at a maximum speed of 1333 MHz in 2DPC configurations even though the specified DIMM speed is higher A2 B2 C2 D2 EL F1 G1 H1 64 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 35 is not a complete list of all supported DIMM populations but highlights common configuration options Table 35 Supported DIMM Configurations CPU 1 DIMMs CPU 2 DIMMs capacity for 5 1 8 1 8GB 1x8GB 1 8 GB 16 GB 1x16 GB 1 16GB 1x16GB 1 16 GB 32 GB 2x4GB 2 8GB 2x4GB 2 8 GB 16 GB 4x4 4 16GB 4x4GB 4 16 GB 32 GB 2x8 2 16GB 2x8GB 2 16 GB 32 GB 6 x 4 6 24GB 6x4GB 6 24 GB 48 GB 8x4GB 8 32GB 8x4GB 8 32 GB 64 GB 4x 8 GB 4 32GB 4x8GB 4 32 GB 64 GB 8x4GB 8 32GB 8x4GB 8 32 GB 64 GB 1x 3
25. 082RX A 8 GB DDR3 1333 MHz RDIMM PC3 10600 2R x4 1 35v 1 5 1 35 V 2 UCS MR 1X082RZ A 8 GB DDR3 1866 MHz RDIMM PC3 14900 2R x4 1 5 V 2 UCS MR 1X041RY A 4 GB DDR3 1600 MHz RDIMM PC3 12800 1R x4 1 35v 1 5 1 35 V 1 UCS MR 1X041RX A 3 4 GB DDR3 1333 MHz RDIMM PC3 10600 1R x4 1 35v 1 35 V 1 UCS MU 1XO42RE A 4 GB DDR3 1600 MHz ECC UDIMM PC3 12800 2R x8 1 35v 1 35 V 2 Memory Mirroring Option NO1 MMIRROR Memory mirroring option Notes 1 1866 MHz DIMMs cannot be used with Intel Xeon E5 2600 CPUs 2 Dual voltage DIMM operates at 1 5 V with BIOS is set for memory performance mode default or 1 35 V when BIOS is set for power savings mode 3 No longer shipping as of November 2013 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 17 CONFIGURING the SERVER Approved Configurations 1 1 CPU configuration without memory mirroring m Select from 1 to 8 DIMMs Refer to Memory Population Rules page 60 for more detailed information 2 1 CPU configuration with memory mirroring B Select 2 4 6 or 8 identical DIMMs The DIMMs will be placed by the factory as shown in the following table CPU 1 DIMM Placement in Channels Total Number for identical DIMMs MU Blue Slots Black Slots 2 1 B1 4 A1 B1 C1 D1 6 A1 B1 C1 A2 B2 C2 8 A1 B1 C1 D1 A2 B2 C2 D2 Notes 1 Not recommended for performance reasons B Select the memory mirroring option NO1 MM
26. 11 11 CISCO Spec Sheet Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV 0 19 NOVEMBER 17 2014 WWW CISCO OVERVIEW 3x 309 a REDD EES DETAILED VIEWS 4 3 PORC ae edic Chassis Front VIEW A ed dE NU x Ade ec OO ae UNO On P RC d 6 Chassis Rear 7 BASE SERVER STANDARD CAPABILITIES and FEATURES 8 CONFIGURING the SERVER 11 STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP 1 VERIFY SERVER 56 12 2 SELECT CPU s 2 2 13 3 SELECT MEMORY 16 4 SELECT RAID CONFIGURATION 22 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES 5505 29 6 SELECT PCle OPTION CARD s 31 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES 34 8 ORDER POWER SUPPLY llle 38 9 SELECT AC POWER CORD S 39 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM 42 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL 43 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE
27. 2 GB 1 32GB 1x32GB 1 32 GB 64 GB 5 x 8 GB 5 40GB 5x8GB 5 40 GB 80 GB 3 x 16 GB 3 48GB 3 16 3 48 96 6 8 6 48GB 6x8GB 6 48 96 4 8 4 4 8 48 4x8 4x4 8 48 96 7 8 7 56GB 7 8 7 56 112 4 x 16 GB 4 64GB 4x16 GB 4 64 GB 128 GB 8x8 8 64GB 8x8GB 8 64 128 2 x 32 2 64GB 2 32 2 64 128 5 16 5 80GB 5 16 5 80 160 4x16 4x4 GB 8 80GB 4x16 GB 4x4 GB 8 80 GB 160 GB 6 x 16 GB 6 96GB 6 16 6 96 192 4 8 4x16 GB 8 96 4 8 4x16 GB 8 96 192 3 32 3 96GB 3x 32 3 96 192 7 16 7 112GB 7 16 7 112 224 8 16 8 128GB 8 16 8 128 256 4x 32 GB 4 128GB 4x 32GB 4 128 GB 256 GB 8 x 32 GB 8 256GB 8x 32 8 256 GB 512 GB Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 65 SUPPLEMENTAL MATERIAL Low Voltage DIMM Considerations The C220 M3 server can be ordered with dual voltage 1 5 1 35 V DIMMs only Note the following considerations m Low voltage DIMMs within the server must have the identical manufacturer type speed and size Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Po
28. 2609 v2 2 50 80 10 4 6 4 GT s 1333 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 13 CONFIGURING the SERVER Table 3 Available Intel CPUs E5 2600 and E5 2600 v2 Series Processor Family CPUs continued Product ID PID Intel Xeon E5 2600 UCS CPU E5 2690 UCS CPU E5 2680 UCS CPU E5 2670 UCS CPU E5 2667 UCS CPU E5 2665 UCS CPU E5 2660 UCS CPU E5 2650 UCS CPU E5 2650L UCS CPU E5 2643 UCS CPU E5 2640 UCS CPU E5 2630 UCS CPU E5 2630L UCS CPU E5 2620 UCS CPU E5 2609 Notes E5 2690 E5 2680 E5 2670 E5 2667 E5 2665 E5 2660 E5 2650 E5 2650L E5 2643 E5 2640 E5 2630 E5 2630L E5 2620 E5 2609 2 90 2 70 2 60 2 90 2 40 2 20 2 00 1 80 3 30 2 50 2 30 2 00 2 00 2 40 135 130 115 130 115 95 95 70 130 95 95 60 95 80 Cache Size MB 20 20 20 15 20 20 20 20 10 15 15 15 15 10 Cores I CO Ww QPI 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 7 2 GT s 7 2 GT s 7 2 GT s 7 2 GT s 6 4 GT s Highest DDR3 DIMM Clock Support MHz 1600 1600 1600 1600 1600 1600 1600 1600 1600 1333 1333 1333 1333 1066 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock 2 1866 MHz DIMMs cannot be used with E5 2600 CP
29. AN ports support the wake on LAN WoL standard InfiniBand The bus slots in this server support the InfiniBand architecture Front Panel A front panel controller provides status indications and control buttons Power subsystem Up to two 450 W AC 650 W AC or 930 W DC power supplies One is mandatory one more can be added for 1 1 redundancy ACPI This server supports the advanced configuration and power interface ACPI 4 0 standard Fans Chassis m Five hot swappable fans for front to rear cooling Power supply B Fach power supply is equipped with a fan Integrated management BMC running Cisco Integrated Management Controller CIMC firmware Depending on your settings the can be accessed through the 1 GbE dedicated management port the 1 GbE LOM ports or a Cisco virtual interface card VIC 10 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C220 M3 High Density SFF Rack Server m STEP 1 VERIFY SERVER SKU page 12 m STEP 2 SELECT CPU s page 13 m STEP 3 SELECT MEMORY page 16 m STEP 4 SELECT RAID CONFIGURATION page 22 B STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs page 29 m STEP 6 SELECT PCle OPTION CARD s page 31 m STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 33 m STEP 8 ORDER POWER SUPPLY page 38 STEP 9 SEL
30. ATA 240 GB UCS SD120GOKS2 EV 120 GB SATA 2 5 inch Enterprise Value 6G SSD SATA 120 GB UCS SD100GOKA2 G 100 GB SATA 2 5 Enterprise Value SSD SATA 100 GB Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 29 CONFIGURING the SERVER NOTE When creating a RAID volume follow these guidelines o B Use the same capacity for each drive in the volume B Use either all SAS drives or all SATA drives B Use either all HDDs or all SSDs Approved Configurations 1 Onboard RAID Mezzanine Cards and all PCle RAID Controllers B If you have not selected an onboard RAID upgrade option 5 or 55 a mezzanine card or a PCle RAID controller for internal drives LSI MegaRAID 9271 8i or 9271CV 8i you may select up to 4 SATA only drives which will be controlled with the embedded SATA only RAID controller B Otherwise select up to eight SAS SATA drives listed in Table 10 You can mix SAS and SATA drives Caveats B You can mix SATA and SAS drives 30 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 6 SELECT PCle OPTION CARD s The standard PCie card offerings are B Converged Network Adapters CNAs B Network Interface Cards NICs m Host Bus Adapters HBAs UCS Storage Accelerators Select PCle Option Cards The available PCle option cards are listed in Table 11 Table 11 Available PCle Option Cards
31. Disable all PCIe 51015 oprom execution LOM Port ptianRUH Enabled LOM Port 4 ptionR M Enabled All PCIe Slots ptionRUH Enabled Tr 1 mi J m a 2mm rr l Enabled SlotID 2 ptionR M Et Led 11 Enter 5 T r OA De rr SlotID M ptionRUM Lec version 2 15 1226 Copyright 2012 American Megatrends Inc 68 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Serial Port Details The pinout details of the rear RJ 45 serial port connector are shown in Figure 9 Figure 9 Serial Port Female RJ 45 Connector Pinout Pin Signal RTS Request to Send DTR Data Terminal Ready TxD Transmit Data GND Signal Ground GND Signal Ground RxD Receive Data DSR Data Set Ready CTS Clear to Send Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 69 SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing related parts you may need during the life of your server Some of these parts are configured with every server and some may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 36 Table 36 Upgrade and Servicing related Parts for UCS C220 M3 SFF Server Spare Product ID PID
32. ECT AC POWER CORD s page 39 B STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 42 STEP 11 ORDER TRUSTED PLAT FORM MODULE OPTIONAL page 43 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL page 44 STEP 13 ORDER OPTIONAL USB 2 0 DRIVE page 45 STEP 14 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 46 STEP 15 SELECT OPERATING SYSTEM MEDIA KIT page 49 m STEP 16 SELECT SERVICE and SUPPORT LEVEL page 50 m OPTIONAL STEP ORDER RACK s page 55 B OPTIONAL STEP ORDER PDU page 56 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 11 CONFIGURING the SERVER STEP1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 of the C220 High Density SFF Rack Base Server Product ID PID Description UCSC C220 M3S UCS C220 M3 SFF no CPU memory HDD SDD power supply SD cards or PCle cards with 1 rail kit The Cisco C220 M3 server B Includes one tool less rail kit UCSC RAIL1 B Does not include power supply CPU memory hard disk drives HDDs solid state drives SSDs SD cards or plug in PCle cards o NOTE Use the steps on the following pages to configure the server with the components that you want to include 12 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP2 SELECT CPU s The standard CPU
33. F CON PSJ3 C220M3SF PSJ3 No UCS SUPP PSS 24X7X4 UCS C220 M3 5 CON PSJ4 C220M3SF PSJ4 No UCS SUPP PSS 24X7X2 UCS C220 M3 SFF Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 26 Table 26 Partner Support Service for UCS Hardware Only Product ID PID eee ie Description CON PSW2 C220M3SF PSW2 No UCS W PL PSS 8X5X4 UCS C220 M3 SFF CON PSW3 C220M3SF PSW3 No UCS W PL PSS 24 7 4 UCS C220 5 CON PSW4 C220M3SF PSW4 No UCS W PL PSS 24 7 2 UCS C220 5 Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to B Optimize the uptime performance and efficiency of your UCS B Protect your vital business applications by rapidly identifying and addressing issues m Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations 52 Cisco UCS
34. IBLE FLASH SD CARD MODULE OPTIONAL You can order either one or two 32 GB SD cards See Figure 6 on page 57 for the location of the SD cards There are two locations SD1 and SD2 Table 19 32 GB Secure Digital SD Card Product ID PID PID Description UCS SD 32G S 32 GB SD Card for UCS servers Caveats B The following configurations are valid One 32 GB SD card Two 32 GB cards 44 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 13 ORDER OPTIONAL USB 2 0 DRIVE You can order one optional USB 2 0 drive The USB drive ordering information is listed in Table 20 Table 20 USB 2 0 Drive Product ID PID PID Description UCS USBFLSH S 4GB 4GB Flash USB Drive shorter length for all servers except C260 See Figure 6 on page 57 for the location of the USB connector Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 45 CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 21 Table 21 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID Microsoft Windows Server MSWS 08R2 STHV Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL MSWS 08R2 ENHV Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL MSWS 08R2 DCHV2S Windows Svr 2008 R2 2 CPU Data Cent
35. IRROR as shown in Table 4 on page 17 3 2 CPU configuration without memory mirroring m Select from 1 to 8 DIMMs per CPU Refer to Memory Population Rules page 60 for more detailed information 18 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER 4 2 CPU configuration with memory mirroring B Select 2 4 6 or 8 identical DIMMs per CPU The DIMMs will be placed by the factory as shown in the following table Number CPU 1 DIMM Placement in Channels CPU 2 DIMM Placement in Channels of for identical dual rank DIMMs for identical dual rank DIMMs ird Blue Slots Black Slots Blue Slots Black Slots 2 1 B1 E1 F1 4 A1 B1 C1 D1 E1 F1 G1 H1 6 A1 B1 C1 2 2 2 E1 F1 G1 2 2 2 8 A1 B1 1 01 2 2 C2 D2 ET F1 G1 H1 2 2 G2 H2 Notes 1 Not recommended for performance reasons B Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 17 o NOTE System performance is optimized when the DIMM type and quantity are equal for both CPUs and when all channels are filled equally across the CPUs in the server Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 19 CONFIGURING the SERVER Caveats B System speed is dependent on how many DIMMs are populated per channel See Table 5 for details Table 5 DIMM
36. Ms DIMMs per Channel DPC Notes DIMMs in the Same Channel DIMMs in the same channel for example 1 and A2 can have different capacities You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM DIMMs will run at the lowest speed of the DIMMs CPUs installed You cannot mix DIMM types in a channel 1 DPC or 2 DPC See Table 5 on page 20 for valid LRDIMM and RDIMM 1 DPC and 2 DPC memory configurations UDIMMs run at 1066 MHz at 1 35 V and 1333 MHz at 1 5 V DIMM in the Same Bank For best performance DIMMs in the same bank for example A1 B1 C1 D1 should have the same capacity You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM DIMMs will run at the lowest speed of the DIMMs CPUS installed You cannot mix DIMM types in a bank 3 DPC Not supported 1 Although you can have different DIMM capacities in the same bank this will result in less than optimal performance For optimal performance all DIMMs in the same bank should be identical 2 Only 1866 1600 and 1333 MHz DIMMs are currently available for the C220 M3 server 60 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 32 Table 32 DIMM Population Order per CPU DIMMs Populate Populate
37. NA Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port Ethernet PCle Adapter for M3 Yes No No Servers N2XX ABPCIO3 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for Use RJ45 Ethernet cable Servers d Use Intel SFP Intel X520 Dual Port 10Gb SFP Adapter UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter UCSC PCIE IRJ45 Intel i350 Quad Port 1Gb Adapter Use RJ45 Ethernet cable UCSC PCIE BTG Yes No No Broadcom 57712 Dual Port 10GBASE T w TOE iSCSI Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA EN Preinstalled do not change SFP PCle Cards N2XX AEPCIO5 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Preinstalled do not change 5 N2XX AQPCIO3 QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA EN Preinstalled do not change SFP 36 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 14 PCle Card Compatibility continued Cisco SFP Modules PCle Cards Cables SFP 10G SR DS SFP FC8G SW N2XX AQPCIO5 QLogic QLE2562 Dual Port 8Gb Fibre Channel EN Preinstalled do not change SFP UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics EN Preinstalled do not change SFP UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics EN Preinstalled do not change SFP Notes 1 This card sup
38. Parameter Minimum Temperature operating 41 to 104 F 5 to 40 C derate the maximum temperature by 1 C per every 305m of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating 10 to 9076 non condensing Altitude operating to 3 000 m 0 to 10 000 ft Altitude nonoperating to 12 192 m 0 to 40 000 ft Sound Power level Measure 5 4 A weighted per 1507779 LWAd Bels Operation at 73 F 23 C Sound Pressure level Measure 37 A weighted per 1507779 LpAm dBA Operation at 73 F 23 C 82 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C Series servers are listed in Table 44 Table 44 UCS C Series Regulatory Compliance Requirements Parameter Regulatory Compliance Safety EMC Emissions EMC Immunity Description Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICESOO3 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EN55024 CISPR24 EN300386 KN24 Cisco UCS Cisco UCS C220 M3 High Density Rack
39. SE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES SAP 2S 1G 1A SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES SAP 2S 1G 3A SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES SAP 2S 1G 5A SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES SAP 2S UG 1A SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd SLES SAP 2S UG 3A SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Support Reqd SLES SAP 2S UG 5A SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd 46 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 21 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID Red Hat Enterprise Linux RHEL 25 16G 1A RHEL 25 16G 3A RHEL 25 4G 1A RHEL 25 4G 3A RHEL 25 UG 1A RHEL 25 UG 3A RHEL HA 25 1A RHEL HA 25 3A RHEL RS 25 1A RHEL RS 25 3A RHEL SFS 25 1A RHEL SFS 25 3A BMC BMC 012 BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2
40. Server Small Form Factor Disk Drive Model 83 TECHNICAL SPECIFICATIONS 1 1 1 li Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam oan Jose Singapore The Metherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc andor its affilkates in the 5 and other countries A listing of Cisco s trademarks can be found al wwwciscocom go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply partnership relationship between Cisco and any other company 1005R 84 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model
41. Us 14 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Approved Configurations 1 1 CPU configurations B Select any one CPU listed in Table 3 2 2 CPU Configurations B Select two identical CPUs from any one of the rows of Table 3 on page 13 Caveats You can select either one processor or two identical processors B For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 13 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result B For configurations that use 130 W or 135 W CPUs the minimum power supply required is 650 W UCSC PSU 650W See STEP 8 ORDER POWER SUPPLY page 38 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 15 CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are B DIMMs Clock speed 1866 1600 or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 5 V or 1 35 V Registered or unbuffered ECC DDR3 DIMMs RDIMMs or UDIMMs or load reduced DIMMs LRDIMMs B Memory is organized with four memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C220 M3 SFF Memory Organization Chan D Chan H 16 DIMMS 512 GB maximum memory 4 memory channels per CPU up to 2 DIMMs per channel
42. VS5 STD 5A VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VS5 ENTP 5A VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A UCS VMW TERMS 48 Product ID PID VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 4 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMware vSphere 5 Enterprise for 1 Processor 1 Year Support VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support VMware vSphere 5 Enterprise for 1 Processor 4 Year Support VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rad VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMware vCenter 5 Server Standard 1 yr support required VMware vCenter 5 Server Standard 2 yr support required VMware vCenter 5 Server Standard 3 yr support required VMware vCenter 5 Server Standard 4 yr suppor
43. X7X2 UCS C220 M3 SFF CON OSP C220M3SF Yes ONSITE 24X7X4 UCS C220 M3 SFF CON OSE C220M3SF Yes ONSITE 8X5X4 UCS C220 M3 SFF CON OS C220M3SF Yes ONSITE 8X5XNBD UCS C220 M3 SFF CON S2P C220M3SF No SMARTNET 24X7X2 UCS C220 5 CON SNTP C220M3SF No SMARTNET 24X7X4 UCS C220 M3 SFF CON SNTE C220M3SF NO SMARTNET 8X5X4 UCS C220 M3 SFF CON SNT C220M3SF No SMARTNET 8X5XNBD UCS C220 M3 SFF 50 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco SMARTnet for UCS Hardware Only Service You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 24 Table 24 SMART net for UCS Hardware Only Service Service On T Product ID PID Level Site Description CON UCW7 C220M3SF UCW7 Yes UCS HW 24 7 405 UCS C220 SFF CON UCW5 C220M3SF UCW5 Yes UC PLUS 8X5XNBDOS UCS C220 M3 SFF Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their ow
44. ack Server Small Form Factor Disk Drive Model 25 CONFIGURING the SERVER Notes 1 The SAS 9285CV 8e is compatible with Express 2 0 x8 and the 9271 81 9271 81 and 9286CV 8e are compatible with PCI Express 3 0 x8 NOTE The 9266CV 8i and 9285CV 8e RAID controllers will reach end of life EOL in November 2013 After then they will no longer be available NOTE Although RAID levels 50 and 60 are not orderable from the factory they are supported for selected controllers as shown in Table 6 lt CAUTION If one of your RAID cards is equipped with a a battery backup unit BBU be aware that hot swapping the BBU is not supported Please perform a graceful shutdown of the server prior to replacing the BBU Approved Configurations The C220 M3 SFF server has an 8 drive backplane B 5 and ROM55 embedded RAID upgrade options support up to 8 internal drives Mezzanine card UCSC RAID 11 C220 supports up to 8 internal drives Mezzanine card UCSC RAID MZ 220 supports up to 8 internal drives SAS 9271 8i and 9271CV 8i PCle cards support up to 8 drives LSI MegaRAID SAS 9285CV 8e and 9286CV 8e PCle cards support up to 8 external SAS ports 240 external drives 26 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER See Table 9 for a summary of the supported RAID configuration options Table 9 Supported RAID Configurations
45. agement arm see the Cisco UCS C220 Installation and Service Guide at this URL http www cisco com en US docs unified computing ucs c hw C220 install C220 pdf o NOTE UCS C220 servers ship with a tool less rail kit 42 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 18 Table 18 Trusted Platform Module Product ID PID PID Description UCSX TPM1 001 Trusted Platform Module NOTE The module used in this server conforms to TPM v1 2 1 3 as defined by the Trusted Computing Group It is also SPI based Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 43 CONFIGURING the SERVER STEP 12 ORDER CISCO FLEX
46. ax Cables Product ID PID PID Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H10GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered You may choose or two twinax cables for each compatible PCle network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 13 Table 13 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring DS SFP FC8G SW 8 Gbit SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring 34 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered B You may choose one two SFP optical modules cables for each compatible PCle network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use co
47. controller on motherboard from Table 6 on page 23 One mezzanine RAID controller from Table 7 on page 23 One internal drive RAID controller slot 2 from Table 8 on page 24 One external drive RAID controller slot 1 or 2 from Table 8 on page 24 One mezzanine RAID controller from Table 7 on page 23 and one external drive RAID controller slot 1 or 2 from Table 8 on page 24 NOTE In 2 configurations slot 2 is the default slot supported for internal drive RAID controller Slot 1 or slot 2 can be used for one external drive RAID controller or PCle expansion cards You can change the default card slot for a RAID controller to a different slot by going into the BIOS and reconfiguring the option ROM settings You may also select an appropriate optional RAID configuration listed in Table 8 on page 24 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 67 SUPPLEMENTAL MATERIAL The server contains an Option ROM OPROM for the PCle slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCle slots not used for booting so that resources are available for the slots that are used for booting An example OPROM BIOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM Aptio Setup Utility Copyright D 2012 American Megatrends Inc mj rre LS Advanced A Enable or
48. cts ps10312 serv_group_home html Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model OPTIONAL STEP ORDER RACK s OPTIONAL STEP ORDER RACK s The optional R42610 rack is available from Cisco for the C Series servers including the C220 M3 SFF server This rack is a standard 19 inch rack and can be ordered with a variety of options as listed in Table 29 Racks are shipped separately from the C220 M3 SFF server Table 29 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 RACK FASTEN 001 RACK FASTEN 002 RACK JOIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements For more information about the R42610 rack see RACKS page 74 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 55 OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC220 M3 server This PDU is available in a zero rack unit RU style see Table 29 Tabl
49. d remote supercapacitor for data cache power backup supercapacitor not available on the 9271 8i B Factory configured RAID options available RAID 0 1 5 6 and 10 see the RAID PIDs section in this table write cache scalable performance use the 9271CV 8l RAID controller instead of the mezzanine RAID controllers UCSC RAID 11 C220 or UCSC RAID MZ 220 as the latter controllers do not support a write cache NOTE For any application requiring Virtualization support VMs with 24 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 8 Available PCle RAID Controller Options continued Product ID PID UCS RAID 9285CV E or UCS RAID9286CV 8E Super Capacitor Option UCS RAID CV SC PID Description LSI MegaRAID SAS 9285CV 8e or 9286CV 8e RAID 0 1 5 6 10 B Supports from one to eight external SAS ports up to 240 external drives NOTE For 545 9285CV 8e or 9286CV 8e external drive enclosure e support see the compatibility list enclosure section at the following link http tinyurl com b4etshk Cisco is able to support customers with questions related to the SAS 9285CV 8e or 9286CV 8e RAID card however customers should contact their storage vendor for technical support related to enclosure JBOD B includes an chassis mount remote supercapacitor to power on board 1 GB flash backed write cache B Factory configu
50. del CONFIGURING the SERVER STEP5 SELECT HARD DISK DRIVES HDDs SOLID STATE DRIVES SSDs The standard disk drive features are B 2 5 inch small form factor B Hot pluggable B Sled mounted Select Drives The available drives are listed in Table 10 Table 10 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description diia Capacity HDDs UCS HD600G15KS2 E 600 SAS 15K RPM SFF HD 59 7 60068 UCS HD450G15KS2 E 450 GB SAS 15K RPM SFF HDD SAS 450 GB UCS HD12T10KS2 E 1 2 TB 6Gb SAS 10K RPM SFF HDD SAS 1 2 TB A03 D1TBSATA 1TB SATA 7 2K RPM SFF HDD SATA 1 TB UCS HD1T7KS2 E 1TB SAS 7 2K RPM 2 5 inch HDD SAS 1 TB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB A03 D600GA2 600 GB 6Gb SAS 10K RPM SFF HDD SAS 600 GB A03 D500GC3 500 GB SATA 7 2K RPM SFF HDD SATA 500 GB A03 D300GA2 300 GB 6Gb SAS 10K RPM SFF HDD SAS 300 GB UCS HDD300GI2F 105 300 GB 6Gb SAS 15K RPM SFF SAS 300 GB SSDs UCS SD800GOKS2 EP 800 GB 2 5 inch Enterprise Performance SAS 550 SAS 800GB UCS SDA00GOKS2 EP 400 GB 2 5 inch Enterprise Performance SAS SSD SAS 400 GB UCS SD200GOKS2 EP 200 GB 2 5 inch Enterprise Performance SAS SSD SAS 200 GB UCS SD960GOKS2 EV 960 GB SATA 2 5 inch Enterprise Value 6G SSD SATA 960 GB UCS SDA80GOKS2 EV 480 GB SATA 2 5 inch Enterprise Value 6G SSD SATA 480 GB UCS SD400GOKA2 G 400 GB SATA 2 5 Enterprise Value SSD SATA 400 GB UCS SD240GO0KS2 EV 240 GB SATA 2 5 inch Enterprise Value 6G SSD S
51. e 30 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUs page 76 56 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C220 M3 chassis with the top cover removed is shown in Figure 6 Figure 6 C220 M3 SFF With Top Cover Off 25 o 8 i OY a OY Q Se Se Xe O BC XX 906066 905000 90060 90060 90000 OOOG 90000 0060 90600 0060 90906 000 90650 QOGOS 900660 96060 90650 6606 06060 ES ES OOeoco QOeOCO 6066 9066 QOeCO 9060 QOeOO 00 00 eg C
52. edded SATA only RAID controller that supports up to four SATA only drives RAID 0 1 10 NOTE When creating a RAID volume follow these guidelines o B Use the same capacity for each drive in the volume B Use either all SAS drives or all SATA drives B Use either all HDDs or all SSDs NOTE The number of RAID groups virtual drives supported per controller is as follows m Embedded RAID 8 B LSI MegaRAID 9271 81 or 9271CV 8i RAID controller card 64 m LSI MegaRAID 9285CV 8e or 9286CV 8e RAID controller card 64 m Cisco UCSC RAID SAS 2008 81 Mezzanine Card 16 The RAID controller choices are 1 Embedded RAID on motherboard NOTE The RAID configuration options listed in Table 8 on page 24 are not available if you choose embedded RAID in this case you must configure RAID yourself using separate software 2 Mezzanine RAID controller cards not supported in 1 CPU configurations 3 PCle RAID controllers Cisco can provide factory configured RAID systems depending on the RAID controller chosen and the number of drives ordered Factory configured RAID options are listed with each RAID card description 22 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Select RAID Options Select one of the following these choices are dependent on the number of CPUs installed B One embedded RAID upgrade option for internal drives or
53. eight UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics Half UCS Storage Accelerators UCSC F FIO 5200MP UCS 5200 GB Fusion ioMemory3 PX Performance line for C Series Full UCSC F FIO 2600MP UCS 2600 GB Fusion ioMemory3 PX Performance line for C Series Half UCSC F FIO 1300MP UCS 1300 GB Fusion ioMemory3 PX Performance line for C Series Half UCSC F FIO 1000MP UCS 1000 GB Fusion ioMemory3 PX Performance line for C Series Half UCSC F FIO 3000M Cisco UCS 3 0 TB MLC Fusion ioDrive2 for C Series Servers Full UCSC F FIO 1205M Cisco UCS 1205 GB MLC Fusion ioDrive2 for C Series Servers Half UCSC F FIO 785M Cisco UCS 785 GB MLC Fusion ioDrive2 for C Series Servers Half UCSC F FIO 365M Cisco UCS 365 GB MLC Fusion ioDrive2 for C Series Servers Half Approved Configurations 1 No PCle RAID controller B If you did not choose a PCle RAID controller for example you are using embedded RAID or a mezzanine RAID controller you can select up to one PCie option card for 1 CPU systems or two PCie option cards for 2 CPU systems listed in Table 11 on page 31 2 One PCle RAID controller B If you selected a PCle RAID controller you can select none of the optional PCle cards for 1 CPU systems or one of the optional PCle cards for 2 CPU systems listed in Table 11 on page 31 NOTE If a PCle RAID controller card is installed any optional PCle card you select will be installed in the full height slot RAID controllers are alway
54. ensity over a wide range of business workloads from web serving to distributed database The enterprise class UCS C220 M3 server extends the capabilities of Cisco s Unified Computing System portfolio in a 1U form factor with the addition of the Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs that deliver significant performance and efficiency gains In addition the UCS C220 M3 server provides 16 DIMM slots up to 8 drives and 2 x 1 GbE LAN on motherboard LOM ports delivering outstanding levels of density and performance in a compact 1U package Figure 1 Cisco UCS C220 M3 High Density SFF Rack Server Front View 9 up CI oes LAS LIII 1 8 FP 3 Rear View Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 5 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C220 M3 High Density SFF Rack Server Figure 2 Chassis Front View E A 07 1 1 ape 1 E By p peo er Hooo p EE a Thons IIs M eee EE X 331682 HE Power button power status LED 6 Power supply status LED Identification button LED LE Network link activity LED 3 System status LED status LED 8 Asset tag serial number A status
55. er MSWS 12 ST2S Windows Server 2012 Standard 2 CPU 2 VMs MSWS 12 DC2S Windows Server 2012 Datacenter 2 CPU Unlimited VMs MSWS 12 ST2S NS Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12 DC2S NS Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC MSWS 12R2 ST2S Windows Server 2012 R2 Standard 2 CPU 2 VMs MSWS 12R2 DC2S Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs MSWS 12R2 ST2S NS Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12R2 DC2S NS Windows Server 2012 R2 Datacen 2 CPU Unlim VM No Cisco Svc SUSE SLES SVR 2S 1G 1A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 3A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 5A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd 3yr Support Reqd 5yr Support Reqd 1yr Support Reqd 3yr Support Reqd v 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SLES SHA 2S 5A SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SLES HGC 2S 1A SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SLES HGC 2S 3A SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SLES HGC 2S 5A SU
56. es servers and fabric interconnects B Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for EIA standard 19 inch racks Rack specifications are listed in Table 37 Table 37 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 299 83 lb 136 kg 354 lb 161 kg Yes 42RU 2100 lb 954 kg Not applicable Expansion Rack 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 lb 105 kg 284 lb 129 kg No 42RU 2100 lb 954 kg Not applicable o NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet 74 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Figure 10 Cisco R42610 Rack Front view door closed Front view door open Front view door removed Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 75 SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units PDUs
57. ese half height cards in slot 1 the full height slot B Other considerations for the Cisco VIC 1225 or 1285 Supports 10G SFP optical and copper twinax connections The server supports installation of one Cisco VIC card and it is supported only in PCle slot 1 Requires that the server has CIMC firmware version 1 4 6 or later installed There is a heartbeat LED on the top of the card that indicates when firmware is active To use this card for UCS integration Cisco UCS Manager mode with Cisco UCS Manager 2 1 0 or later the minimum card firmware and uboot image level is 2 1 0 306 B help ensure that your operating system is compatible with the card you have selected check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod technical reference list html Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 33 CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Table 12 lists the copper twinax cables available for the PCle cards You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to improve signal quality Table 12 Available Twin
58. features are m Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs see the following link for instructions on how to upgrade your server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs http preview cisco com en US docs unified_computing ucs c CPU IVB install IVB C html m Intel C600 series chipset m Cache size of up to 30 MB Select CPUs The available CPUs are listed in Table 3 Table 3 Available Intel CPUs E5 2600 and E5 2600 v2 Series Processor Family CPUs Highest Intel Clock Power Cache DDR3 DIMM Product ID PID Number Freq W Size Cores QPI Clock GHz MB Support MHz Intel Xeon E5 2600 v2 UCS CPU E52697B E5 2697 v2 2 70 130 30 12 8 GT s 1866 UCS CPU E52695B E5 2695 v2 2 40 115 30 12 8 GT s 1866 UCS CPU E52690B E5 2690 v2 3 00 130 25 10 8 GT s 1866 UCS CPU E52680B E5 2680 v2 2 80 115 25 10 8 GT s 1866 UCS CPU E52670B E5 2670 v2 2 50 115 25 10 8 GT s 1866 UCS CPU E52667B E5 2667 v2 3 30 130 25 8 8 GT s 1866 UCS CPU E52660B E5 2660 v2 2 20 95 25 10 8 GT s 1866 UCS CPU E52650B E5 2650 v2 2 60 95 20 8 8 GT s 1866 UCS CPU E52640B E5 2640 v2 2 00 95 20 8 8 GT s 1600 UCS CPU E52637B E5 2637 v2 3 50 130 15 4 8 GT s 1866 UCS CPU E52630B E5 2630 v2 2 60 80 15 6 8 GT s 1600 UCS CPU E52620B E5 2620 v2 2 10 80 15 6 8 GT s 1600 UCS CPU E52643B E5 2643 v2 3 50 130 25 6 8 GT s 1866 UCS CPU E52650LB E5 2650L v2 1 70 70 25 10 8 GT s 1600 UCS CPU E52630LB 5 26301 v2 2 40 60 15 6 8 GT s 1600 UCS CPU E52609B E5
59. ical and pairs in channels C and D must be identical However the DIMMs used in channels A and B and in C and D can be different Non ECC DIMMs are not supported B Memory mirroring reduces the amount of available memory by 50 quantity of DIMMs must be even for mirroring m When single and dual rank DIMMs are populated for 2DPC always populate the dual rank DIMM in the blue DIMM slot and the single rank DIMM in the black DIMM slot only the 4GB DIMMs are single rank 20 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER B By default starting with UCSM 2 0 4 DIMMs run in memory performance mode 1 5v by BIOS default which yields faster memory speeds than when the BIOS is set for the memory to run in power savings mode Memory speed is dependent on factors such as CPU choice DIMM choice DIMM population how many DIMMs per channel are populated BIOS setting For the DIMMs to run in power savings mode 1 35 V if the DIMM supports this change the BIOS setting to power savings mode For more information regarding memory see CPUs and DIMMs page 58 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 21 CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE If you do not select a mezzanine card a PCle RAID controller or one of the embedded RAID upgrade options you will have an emb
60. isk Drive Model SUPPLEMENTAL MATERIAL Table 36 Upgrade and Servicing related Parts for UCS C220 M3 SFF Server Spare Product ID PID Description UCS CPU EP2 PNP Pick n place CPU tools for M3 EP v2 12 core CPUs Purple UCS CPU GREASE2 Thermal grease for 2 CPUs only for C220 C240 Red tip syringe UCSX HSCK UCS Processor Heat Sink Cleaning Kit when replacing a CPU Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server 2 If your server contains an LSI MegaRAID SAS 9266 81 RAID controller card with battery backup UCS RAID 9266 the card contains a battery backup unit UCS RAID BBU which can be replaced If your server contains LSI MegaRAID SAS 9266 81 RAID controller card without a battery backup unit UCS RAID 9266NB the card does not contain a battery backup unit UCS RAID BBU however you can retrofit the card with a battery backup if desired Note that you cannot retrofit a UCS RAID 9266NB or UCS RAID 9266 RAID card with an LSI Cachevault Power Module also known as Supercap 3 You can order a replacement only for the RAID cards listed You cannot retrofit a UCS RAID 9266NB or UCS RAID 9266 RAID card with LSI Cachevault Power Module also known as Supercap The server is shipped with the inner rail attached to the chassis This SD card is blank The required image for the C220 server can be downloaded to the card
61. le Product ID PID PID Description N20 BKVM KVM cable for B Series Blade Server console port Figure 12 KVM Cable 192621 Connector to server front panel VGA connector for a monitor DB 9 serial connector Two port USB connector for a mouse and keyboard Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 77 SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports and RAID Card Backup Location The C220 M3 SFF motherboard has a general purpose USB socket and two SD sockets as shown in Figure 13 The mounting location for the RAID SuperCap data cache power backup module is also shown Figure 13 Motherboard USB and SD Ports and RAID Card Super Capacitor Location of lt a O O Q ee jew le OO O O e Oo a Qe XO Q Se Se Q of 595 ORO 90 505950 la Sa 02595 2600 EPSPS Q etia 560 m gt z OQ 295 Oy a O O 090000000 PCle1 CO Se le Q e le lt a XO e
62. mmon fiber optic cables widely available See the Figure 5 on page 37 for typical SFP and twinax connections to the network cards Caveats Check the table on the following page for compatibility between the PCle network cards and SFPs or twinax cables NOTE The table shows all PCle network cards for all C series servers Not all of the cards shown in the table are supported in this server The intent of the table is to show compatibility between cards and twinax cables or SFPs Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 35 CONFIGURING the SERVER Table 14 PCle Card Compatibility Twinax Cisco SFP Modules Cables SFP 10G SR DS SFP FC8G SW Converged Network Adapters CNAs UCSC PCIE BSFP Yes Yes No Broadcom 57712 Dual Port 10Gb SFP w TOE iSCSI UCSC PCIE CSC 02 Yes Yes No Cisco VIC 1225 Dual Port 10Gb SFP UCSC PCIE C10T 02 No No No Cisco VIC 1225T Dual Port 10GBaseT CNA UCSC PCIE C40Q 02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA UCSC PCIE C40Q 03 Cisco VIC 1385 Dual Port 40Gb QSFP CNA w RDMA UCSC PCIE ESFP Emulex 11102 dual port 10 GbE FCoE CNA Gen 3 UCSC PCIE QSFP QLogic QLE8242 CU dual port 10 GbE FCoE CNA Use Qlogic SFP UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Use Qlogic SFP UCSC PCIE E14102 Emulex 14102 dual port 10 GbE FCoE C
63. n branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them B Expand their service portfolios to support the most complex network environments B Lower delivery costs B Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL WWW cisco com go partnerucssupport The two Partner Unified Computing Support Options include B Partner Support Service for 5 B Partner Support Service for UCS Hardware Only Partner Support Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 51 CONFIGURING the SERVER See Table 25 Table 25 Partner Support Service for UCS Service P Product ID PID Level Description Site GSP CON PSJ1 C220M3SF PSJ1 No UCS SUPP PSS 8X5XNBD UCS C220 M3 SFF CON PSJ2 C220M3SF PSJ2 No UCS SUPP PSS 8X5X4 UCS C220 M3 SF
64. on E5 2600 v2 CPUs or downgrading from Intel Xeon E5 2600 v2 to Intel Xeon E5 2600 CPUs 71 Adding an Additional CPU with CPU heat sink 71 Motherboard Lithium Battery 71 CPU Removal and Installation pick place Tool Set 72 Thermal Grease with syringe applicator for CPU to Heatsink Seal 72 Air Baffle Replacement Kit 72 CPU Heat Sink Cleaning Kit 73 74 POUS PvE 76 KVM CABUE eee DARREN RPM SERE NV SS AS 35 eee 7 Motherboard USB and SD Ports and RAID Card Backup Location 78 TECHNICAL SPECIFICATIONS 79 Dimensions and Weight 79 Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 5 Power Specifications Environmental Specifications Compliance Requirements Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model OVERVIEW OVERVIEW The Cisco amp UCS C220 M3 rack server is designed for performance and d
65. p to eight SAS SATA drives supporting RAID 0 1 and 10 This card has a product ID PID of UCSC RAID MZ 220 m PCle RAID controllers 6 Gbs e LSI MegaRAID SAS 9271 81 9271CV 8i RAID 8 port PCle RAID controllers with on board 1 GB data cache and chassis mounted remote supercap for data cache power backup supercap not present on 9271 81 supporting RAID levels 0 1 5 6 10 50 60 and up to eight internal SAS SATA drives e LSI MegaRAID 9285CV 8e or 9286CV 8e PCle RAID controllers with on board 1 GB cache and chassis mounted remote supercap for data cache power backup supporting RAID levels 0 1 5 6 10 50 60 Supports 8 external SAS ports up to 240 external drives Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 9 BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Interfaces B Rear panel e One RJ45 serial port connector e Two USB 2 0 port connectors e One DB15 VGA connector e Two RJ 45 10 100 1000 Ethernet port connectors e One 45 10 100 1000 Ethernet management port using Cisco Integrated Management Controller CIMC firmware B Various PCle card ports dependent on which cards are installed e Converged Network Adapter CNA ports e Network Interface Card NIC ports e Host Bus Adapter HBA ports m Front panel e One KVM console connector supplies two USB one VGA and one serial connector WoL The 1 Gb Base T Ethernet L
66. per CPU CPU 1 Slots CPU 2 Slots 1 A1 E1 2 A1 B1 E1 F1 3 A1 B1 C1 E1 F1 G1 4 A1 B1 C1 D1 E1 F1 G1 H1 6 A1 B1 C1 E1 F1 G1 A2 B2 C2 E2 F2 G2 8 A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 Notes 1 Not recommended for performance reasons Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 61 SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C220 M3 server B DIMMs must be DDR3 DIMMs B Do not mix DIMMs with different clock rates in a channel RDIMMs and LRDIMMs ECC and non ECC DIMMs B There are blue and black DIMM slots Populate blue slots first m When single and dual rank DIMMs are populated for 2DPC always populate the dual rank DIMM in the blue DIMM slot and the single rank DIMM in the black DIMM slot Many memory configurations are possible For best results follow Table 33 when populating 1600 and 1866 MHz DIMMs for Intel Xeon E5 2600 v2 CPUs and Table 34 when populating 1600 MHz DIMMs for Intel Xeon E5 2600 CPUs Table 33 Recommended Memory Configurations for Intel Xeon E5 2600 v2 CPUs with 1600 and 1866 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs Blue Slots Black Slots Blue Slots Black Slots Fai 1 2 1 2 peed MHz 1 1 C1 D1 A2 B2 C2 D2 EL F1 1 1 E2 F2 G2 H2 D pee
67. ports a 4x10 Gbps QSFP to SFP breakout fiber cable Figure 5 Network Card Connections Network PCle Card Optical SFP Modules ET Fiber Optic Cables gt Cea ee 44 Redundant Top of Rack Access Switches i lt i Network PCle Card Twinax Copper Cables Redundant Top of Rack be Access Switches Cisco UCS Cisco 5 C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 37 CONFIGURING the SERVER 38 STEP 8 ORDER POWER SUPPLY The C220 M3 SFF server accommodates two power supplies A lightly loaded server can operate from one 650 W power supply A fully loaded server might need to be powered with two 450 W or two 650 W power supplies see Table 15 NOTE For configurations that use 130 or 135 W CPUs the minimum power supply required is 650 W UCSC PSU 650W See STEP 2 SELECT 5 page 13 Use the power calculator at the following link to determine the needed power based on the options chosen CPUs drives memory and so on https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx Table 15 Power Supply PIDs Product ID PID PID Description UCSC PSU 450W 450 W power supply UCSC PSU 650W 650 W power supply UCSC PSU 930WDC 930 W 48V DC power supply o NOTE In two power supply server both power supplies must be identical Cisco UCS Cisco UCS C220 M3 High Densi
68. red RAID options RAID 0 1 5 6 10 see the RAID Configuration section in this table Note that factory RAID configuration is not available for these controllers because the factory does not control the storage array attached to them LSI CacheVault Power Module This is a spare supercapacitor It is the exact same supercapacitor that ships with the 9271CV 8i 9285CV 8e and 9286CV 8e cards listed earlier in this table and can be used as a replacement or upgrade part RAID Configuration Options not available for embedded RAID R2XX SRAIDO R2XX RAIDO R2XX RAID1 R2XX RAID5 R2XX RAID6 R2XX RAID10 Enable Single Disk Raid 0 Setting for the following PIDs only UCS RAID9271 8i UCS RAID9271CV 8l UCSC RAID 11 C220 UCSC RAID MZ 220 Factory preconfigured RAID striping option Enable RAID 0 Setting Requires a minimum of one hard drive Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed capacity Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same size speed capacity Factory preconfigured RAID option Enable RAID 10 Setting Requires a even number of drives minimum of four drives of the same size speed capacity Cisco UCS Cisco UCS C220 M3 High Density R
69. rgentina Power Cord 250VAC 10A 3112 Plug Australia Power Cord SFS 250V 10A China AC Power Cord 250V 10A PRC Power Cord 250VAC 10A CEE 7 7 Plug EU Power Cord SFS 250V 10A India Power Cord SFS 250V 10A Israel Images 0 L 2500 mm 7 A Ah Cordset rating 10 A 250 500 V MAX Plug EL 219 IRAM 2073 Length 8 2 ft Connector EL 701 IEC60320 C13 E oy L Plug EL 210 pe Uf Cordset rating 10 A 250 V 500 V MAX Length 2500mm Connector EL 701C EN 60320 C15 BS 1363A 13 AMP fuse Plug EL 218 CCEE GB2009 Cordset rating 10A 250V Connector EL 701 o IEC60320 C13 3 rating 10 16 250 V Length 8 ft 2 in 2 5 m Plug EL 208 Cordset rating 16A 250V m ra 2500mm IEC60320 C13 CONFIGURING the SERVER Table 16 Available Power Cords Product ID PID PID Description Images CAB 9K10A IT Power Cord 250VAC 10A CEI 23 16 VII Plug Italy
70. ro z p LL o Eu Ee n EUER 90800 D QOeOCO 0060 QR FANA WOS QOeOCO 5006 00 00 B Mo 0 es FANS ll emm i 00800 6066 ELT 9000 QOeCO LII 6066 e OOeCO OOOO QOeCO 90 60 OOOO a Drives Trusted platform module socket on hot swappable accessed through front panel motherboard 2 Drive backplane Standard profile PCle riser PCle slot 1 E SuperCap backup unit mounting location az Low profile PCle riser PCle slot 2 Cooling fans five Cisco Flexible Flash SD socket SD2 on PCle riser 2 i SCU upgrade ROM header RAID key Cisco Flexible Flash SD socket 501 on riser 2 DIMM DIMM slots on motherboard 16 on motherboard 15 Internal 5 Cisco UCS Cisco 5 C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 57 SUPPLEMENTAL MATERIAL CPUs and heatsinks two Power supplies two hot swappable access through rear panel Integrated RAID on motherboard and mini SAS 17 RTC battery on motherboard connectors Mezzanine RAID card mini SAS connectors Software RAID 5 header RAID key SAS1 and SAS2 CPUs and DIMMs Physical Layout Each CPU has four DIMM channels B CPU1 has channels A B C and D B CPU2 has channels
71. s installed in the half height slot Caveats B Do not mix Fusion io storage accelerator families do not mix MP family cards with family cards B For 1 CPU systems Only the full height PCle slot slot 1 is supported Neither PCle slot 2 nor the mezzanine card slot are supported Only a single VIC card the Cisco VIC 1225 or 1285 PCle card is supported and must be installed in slot 1 the full height slot 32 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER If any of the Fusion ioDrive2 cards are installed they must be plugged into slot 1 Note that only the Cisco UCS 3 0 TB MLC Fusion ioDrive2 and Cisco UCS 5200 GB Fusion ioMemory3 cards are full height all other Fusion io cards are half height and therefore may need an adapter to hold them securely in the full height slot B For 2 CPU systems Both PCle slots slots 1 and 2 and the mezzanine card slot are supported Only a single VIC card the half height Cisco VIC 1225 or 1285 PCle card is supported and it must be installed in slot 1 the full height slot Only a single Cisco UCS 3 0 TB MLC Fusion ioDrive2 or Cisco UCS 5200 GB Fusion ioMemory3 card is supported and it must be installed in slot 1 the full height slot Up to two of the other Fusion io cards are supported and can be installed in either slot 1 or 2 although an adapter may be needed when installing one of th
72. t required VMware vCenter 5 Server Standard 5 yr support required Acceptance of Terms Standalone VMW License for UCS Servers Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 15 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 22 Table 22 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08R2 ENHV RM MSWS 08R2 DCHV RM MSWS 12 ST2S RM MSWS 12 DC2S RM MSWS 12R2 ST2S RM MSWS 12R2 DC2S RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Media Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media Windows Server 2012 R2 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 R2 Datacen 2 CPU Unlimited VM Rec Media Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 49 CONFIGURING the SERVER STEP 16 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied B Three year parts coverage Next business day
73. the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 28 o NOTE Cisco does not offer certified drive destruction service as part of this service Table 28 Drive Retention Service Options Service Service Service Description Program Name Level GSP Service Level Product ID PID SMART net for UCS UCSD7 24 7 4 Onsite CON UCSD7 C220M3SF Service with Drive UCS DR Retention UCSD7 8x5xNBD Onsite CON UCSD5 C220M3SF Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 53 54 CONFIGURING the SERVER Table 28 Drive Retention Service Options continued M Service Service Service Description Program Name Level GSP Service Level Product ID PID SMART net for UCS UCWD7 24 7 4 Onsite CON UCWD7 C220M3SF HW ONLY Drive UCS HW DR Retention UCWD5 8x5xNBD Onsite CON UCWD5 C220M3SF For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 Unified Computing Services Overview pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US produ
74. the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER page 11 Table 1 Capabilities and Features Capability Feature Description Chassis CPU Chipset Memory Multi bit Error Protection NIC Expansion slots Internal storage devices Cisco Flexible Flash drives One rack unit 1RU chassis One or two Intel Xeon E5 2600 v2 or E5 2600 series processor family CPUs Intel amp C600 series chipset 16 slots for registered or unbuffered ECC DIMMs RDIMMs or UDIMMs or load reduced DIMMs LRDIMMs This server supports multi bit error protection Embedded dual port Intel 1350 PCle based Gigabit Ethernet controller supporting the following B Pre Execution Boot PXE boot iSCSI boot B Checksum and segmentation offload B NIC teaming Two PCle slots on a riser card m One full height profile half length slot with x24 connector and x16 lane One half height profile half length slot with x16 connector and x8 lane Drives are installed into front panel drive bays that provide hot pluggable access B Small Form Factor SFF drives Up to eight 2 5 inch SAS or SATA hot swappable hard disk drives HDDs or solid state drives SSDs B he server also contains one internal USB 2 0 port on the motherboard that you can use with a USB thumb drive for additional storage B UCS Storage Accelerator are also available
75. to 120 VAC nominal 200 to 240 VAC nominal Range 47 to 63 Hz single phase 50 to 60 Hz nominal 7 6 A peak at 100 VAC 3 65 A peak at 208 VAC 11 A 650 W Main power 12 VDC Standby power 12 VDC CSCI Platinum o NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet 80 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS The general power specifications for the C220 M3 SFF server 930 W DC power supply are listed in Table 42 Table 42 UCS C240 SFF Power Specifications 930 W DC power supply Description Specification Class RSP1 Input DC input voltage range B 40 to 72 VDC self ranging 48 to 60 VDC nominal DC line input current steady state B 23 peak at 48 VDC Output 12 V main power output 930W 12 V standby power output 30W Power supply output voltage Rated output load Main power 12 VDC Standby power 12 VDC 2 5 A minimum within 40 72 VDC range For configuration specific power specifications use the Cisco UCS Power Calculator at this URL https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 81 TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C220 M3 server are listed in Table 43 Table 43 UCS C220 M3 Environmental Specifications
76. ty Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD s Using Table 16 select the appropriate AC power cords You can select a minimum of no power cords and a maximum of two If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 16 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to Not applicable allow for a no power cord option CAB N5K6A NA Power Cord 200 240V 6A North America i lt m CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft H TN sn CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CAB C13 C14 AC CORD PWR JMP IEC60320 C14 IEC6 0320 C13 3 0M r M Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 39 CONFIGURING the SERVER Table 16 Available Power Cords Product ID PID SFS 250V 10A AR CAB 9K10A AU SFS 250V 10A CN CAB 250V 10A CN CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS 40 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model PID Description Power Cord SFS 250V 10A A
77. wer Saving Mode unless all DIMMs are low voltage DIMMs B CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operating in Power Saving Mode only and do not support Performance Mode 66 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL RAID Details The available RAID configurations are shown in this section 1 1 CPU Configurations Mezzanine cards are not supported for 1 CPU configurations Therefore only the following RAID controllers are supported for single CPU configurations Select one of these B An embedded RAID controller on motherboard from Table 6 on page 23 B One internal drive RAID controller slot 1 only from Table 8 on page 24 B One external drive RAID controller slot 1 only from Table 8 on page 24 NOTE PCle slot 2 is not supported for 1 CPU configurations NOTE In 1 CPU configurations slot 1 is the default slot supported for e internal drive RAID controller PCle slots 1 or 2 can be used for one external drive RAID controller or for PCle expansion cards You can change the default slot for a RAID controller to a different slot by going into the BIOS and reconfiguring the option ROM OPROM settings You may also select an appropriate optional RAID configuration listed in Table 8 on page 24 2 2 CPU Configurations Select one of the following B An embedded RAID
78. zzanine RAID Controllers not supported in 1 CPU systems Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 23 CONFIGURING the SERVER Table 7 Available Mezzanine Card RAID Options continued Product ID PID PID Description UCSC RAID 11 C220 Cisco UCSC RAID SAS 2008M 8i Mezzanine Card RAID 0 1 5 10 and 50 supported operating at 6 Gbs B Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed B Factory configured RAID options available RAID 0 1 5 and 10 see the RAID PIDs section in this table UCSC RAID MZ 220 Cisco UCSC RAID SAS 2008M 8i Mezzanine Card RAID 0 1 10 supported operating at 6 Gbs B Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed B Factory configured RAID options available RAID 0 1 and 10 see the RAID PIDs section in this table B No data cache backup Table 8 Available PCle RAID Controller Options Product ID PID PID Description RAID Controllers Note that PCle RAID controllers are installed by default in slot 1 for 1 CPU systems and slot 2 for 2 CPU systems UCS RAID9271 8l or LSI MegaRAID SAS 9271 81 or 9271CV 8i RAID controller card with data cache UCS RAID9271CV 8l backup RAID 0 1 10 5 6 50 60 operating at 6 Gbs B Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed B includes a 1 GB Transportable Flash Module TFM and a chassis mounte