Home

Altronix MAXIMAL33 power distribution unit PDU

image

Contents

1. Maximal33 Access Power Controller Rev DSMaximal33 F27K Overview Maximal33 This unit distributes and switches power to access control systems and accessories They convert a 115VAC 60Hz input into sixteen 16 independently controlled 12VDC or 24VDC fuse protected outputs These Fail Safe Fail Secure power outputs may be converted to dry form C contacts The outputs are activated by an open collector sink or normally open NO dry trigger input from an Access Control System Keypad Push Button REX PIR etc Units will route power to a variety of access control hardware devices including Mag Locks Electric Strikes Magnetic Door Holders etc The FACP Interface enables Emergency Egress Alarm Monitoring or may be used to trigger other auxiliary devices The fire alarm disconnect feature is individually selectable for any or all of the sixteen 16 outputs All interconnecting equipment must be UL Listed Specifications 12VDC and or 24VDC outputs Maximum output current 12VDC 11 amp and or 24VDC 11 4 amp Options P S1 P S 2 A 12VDC 5 5amp 12VDC 5 5 amp B 24VDC 5 7 amp 24VDC 5 7 amp C 12VDC 5 5 amp 24VDC 5 7 amp 115VAC 60Hz 7 0 amp input Input fuse rated 3 5 amp 250V Power supply input options a Two 2 common power input for either ACM8 and lock power factory installed b Two 2 isolated power inputs external power supply is required current is determined by the power su
2. cuit protection with auto reset AC input and DC output LED indicators AC fail supervision form C contact Low battery and battery presence supervision form C contact Enclosure accommodates up to four 4 12AH batteries Maximal 33 weights approximate Product weight 40 1 Ibs Shipping weight 44 1 Ibs Agency Approvals UL Listed for Access Control System Units CUL Listed CSA Standard C22 2 UL 294 UL No 205 M1983 Signal Equipment C em CSFM TRY amp FIRE PR es EIS California State Fire Marshal Approved Enclosure Dimensions approximate 26 H x 19 W x 6 25 D 2 0 4 0 7 0 4 0 2 0 TOP 5 41 25 0 85 8 90 8 40 0 85 41 25 E GNE T 74 1 LI T 1 50 1 50 me amp ati 7 50 272 270 10 0 n I c 1 gt n 1 0 10 i i 0 85 8 90 8 40 L 0 85 1 25 BOTTOM 6 25 Altronix Corp 140 58th Street Brooklyn NY 11220 718 567 8181 888 258 7669 altronix com
3. pply connected not to exceed a maximum of 10 amp total Sixteen 16 Access Control System trigger inputs Input options a Sixteen 16 normally open NO inputs b Sixteen 16 open collector inputs c Any combination of the above Sixteen 16 independently controlled outputs Output options a Sixteen 16 Fail Safe and or Fail Secure power outputs b Sixteen 16 form C 5 amp rated relay outputs c Any combination of the above Sixteen 16 auxiliary power outputs unswitched outputs are rated 2 5 amp ACMS8 boards main fuse is rated at 10 amp Output fuses are rated 3 5 amp Red LEDs indicate outputs are triggered relays energized Fire Alarm disconnect latching or non latching is individually selectable for any or all of the sixteen 16 outputs Fire Alarm disconnect input options a Normally open NO or normally closed NC dry contact input b Polarity reversal input from FACP signaling circuit Alarm output relay indicates that FACP input is triggered form C contact rated 1 amp 28VDC Green LED indicates FACP disconnect is triggered Filtered and electronically regulated outputs built in power supply Built in charger for sealed lead acid or gel type batteries Maximum charge current 0 7 amp Automatic switch over to stand by battery when AC fails Zero voltage drop when unit switches over to battery backup AC failure condition Thermal and short cir

Download Pdf Manuals

image

Related Search

Related Contents

User manual  Culture numérique de l`apprenant dans un projet de  Anemómetro grúa    XBee Wi-Fi Development Kit Getting Started Guide  Sony XS-L1030 Product Specifications  

Copyright © All rights reserved.
Failed to retrieve file