Altronix AL600ULACM power extension
Contents
1. 00 YY 000000 L 000 000 13 25 000000 13 53 O ae oe PP Mo as 000000 COLL OO 000000 0 0 0 00 0 N Oo0o0o0o0Oo YY AN A Y A Q A Y Altronix Corp 140 58th Street Brooklyn NY 11220 718 567 8181 888 258 7669 altronix com
2. FACP signaling circuit Alarm output relay indicates that FACP input is triggered form C contact rated 1 amp 28VDC not evaluated by UL Green LED indicates when FACP disconnect is triggered Built in charger for sealed lead acid or gel type batteries AL600ULXB Power Supply Board maximum charge current 7 amp Automatic switch over to stand by battery when AC fails AC input and DC output LED indicators Zero voltage drop when unit switches over to battery backup AC failure condition Short circuit and thermal overload protection AC fail supervision form C contact Battery fail and battery presence supervision form C contact Enclosure accommodates up to two 2 12AH batteries Product weight AL600ULACM 10 3 lbs AL600ULACMCB 10 2 lbs Shipping weight AL600ULACM 11 6 lbs AL600ULACMCB 11 5 lbs Agency Approvals UL Listed for Access Control Systems Units MEA MEA NYC Department of UL 294 Approved Buildings Approved CUL Listed CSA Standard C22 2 h No 205 M1983 Signal Equipment Enclosure Dimensions 15 5 H x 12 W x 4 5 D 393 7 mm x 304 8 mm x 114 3 mm CSFM California State Fire Marshal Approved 1 22 yY NW y 4 5 1 22 1 875 9 97 1 3 1 22 oolo oo T i mon RO 4 OP 0000 o olo 0 00 o pooo o E oo0 o0 00 ZA ROS 0000 00 ss O O 0 0 0 0 o p o o o o N 0000
3. MN Altronix AL600ULACM AL600ULACMCB Power Supply Chargers w Multi Output Access Power Controllers Rev DSAL600ULACM A25F Overview e The AL600ULACM AL600ULACMCEB converts an 115VAC 60Hz input into eight 8 independently controlled 12VDC or 24VDC Fail Safe and or Fail Secure outputs with a total of 6 amp continuous supply current These power outputs can be converted to dry form C contacts AL600ULACM only Outputs are activated by an open collector sink or normally open NO dry trigger input from an Access Control System Card Reader Keypad Push Button PIR etc These units will route power to a variety of access control hardware devices including Mag Locks Electric Strikes Magnetic Door Holders etc The outputs will operate in both Fail Safe and or Fail Secure modes The units are designed to be powered by one common power source factory installed which will provide power for both the board operation and locking devices or two 2 totally independent power sources one 1 providing power for board operation and the other for lock accessory power The FACP Interface enables Emergency Egress Alarm Monitoring or may be used to trigger other auxiliary devices The fire alarm disconnect feature is individually selectable for any or all of the eight 8 outputs AL600ULACM e Eight 8 independently controlled fuse protected outputs AL600ULACMCB e Eight 8 independently controlled PTC protected outputs
4. e Class 2 Rated power limited outputs 12VDC or 24VDC 6 amp supply current Power supply input options a One 1 common power input for ACM8 ACMS8CB and lock power factory installed Two 2 isolated power inputs One 1 to power the ACM8 ACMS8CB and one 1 for lock accessory power external power supply is required Current is determined by the power supply connected not to exceed a maximum of 10 amp total Eight 8 Access Control System trigger inputs Input options a Eight 8 normally open NO inputs b Eight 8 open collector inputs c Any combination of the above Eight 8 independently controlled outputs Output options a Eight 8 Fail Safe and or Fail Secure power outputs b Eight 8 form C 5 amp rated relay outputs AL600ULACM only c Any combination of the above AL600ULACM only Eight 8 auxiliary power outputs unswitched Output ratings Fuses are rated 3 5 amp AL600ULACM PTCs are rated 2 5 amp AL600ULACMCB ACMS8 board main fuse is rated at 10 amp Input 115VAC 60Hz rated 1 9 amp Filtered and electronically regulated outputs built in power supply b Red LEDs indicate outputs are triggered relays energized Fire Alarm disconnect latching or non latching is individually selectable for any or all of the eight 8 outputs Fire Alarm disconnect input options a Normally open NO or normally closed NC dry contact input b Polarity reversal input from
Download Pdf Manuals
Related Search
Related Contents
Service Service Service ANNEXE I RESUME DES CARACTERISTIQUES DU PRODUIT Samsung سامسونج جالاكسي تاب 3 水冷式クーリングタワータイプ Manual - Air & Water ARIS GRID Editor for ArcMap 10 User`s Manual Automotive Meter IDOS DN - Amplitude Services OPTI ES1500C uninterruptible power supply (UPS) Scavenger Transceiver Module STM 300 / STM 300C / STM 300U Copyright © All rights reserved.
Failed to retrieve file