Home
Altronix AL1024ULACM power extension
Contents
1. Alarm output relay indicates that FACP input is triggered form C contact rated 1 amp 28VDC not evaluated by UL Green LED indicates when FACP disconnect is triggered Built in charger for sealed lead acid or gel type batteries AL1024ULXB Power Supply Board maximum charge current 3 6 amp Automatic switch over to stand by battery when AC fails Zero voltage drop when unit switches over to battery backup AC failure condition AC fail supervision form C contact Battery fail and battery presence supervision form C contact AC input and DC output LED indicators Enclosure accommodates up to two 2 12AH batteries UL 294 UL Listed for Access Control Systems Units CUL Listed CSA Standard C22 2 Agency Approvals MEA MEA NYC Department of Approved Buildings Approved CSFM California State Fire No 205 M1983 Signal Equipment Marshal Approved Enclosure Dimensions 15 5 H x 12 W x 4 5 D ji AN AN N YZ YZ 2 0022 i r 0o00 4 ccofesccs A oo Poo o AW Y oo ORONO ON e ooo o 6 625 a9 OOP Po a N DO OOGO W COOOOO 13 25 DGO L 13 53 Zon ae Py ooroo oo 09903050300 A Oo Co Oo a AN N A yz Y yz Altronix Corp 140 58th Street Brooklyn NY 11220 718 567 8181 888 258 7669 altronix com
2. AI Altronix AL1024ULACM AL1024ULACMCB Power Supply Chargers w Multi Output Access Power Controllers Rev DSAL1024ULACM A06F Overview e The ALI024ULACM AL1024ULACMCB converts an 115VAC 60Hz input into eight 8 independently controlled 24VDC Fail Safe and or Fail Secure outputs with a total of 10 amp continuous supply current Outputs are activated by an open collector sink or normally open NO dry trigger input from an Access Control System Card Reader Keypad Push Button PIR etc These units will route power to a variety of access control hardware devices including Mag Locks Electric Strikes Magnetic Door Holders etc The outputs will operate in both Fail Safe and or Fail Secure modes The units are designed to be powered by one common power source factory installed which will provide power for both the board operation and locking devices or two 2 totally independent power sources one 1 providing power for board operation and the other for lock accessory power The FACP Interface enables Emergency Egress Alarm Monitoring or may be used to trigger other auxiliary devices The fire alarm disconnect feature is individually selectable for any or all of the eight 8 outputs AL1024ULACM e Eight 8 independently controlled fuse protected outputs AL1024ULACMCB e Eight 8 independently controlled PTC protected outputs e Class 2 Rated power limited outputs Specifications e 24VDC 10 amp supply
3. current e Power supply input options a One 1 common power input for ACM8 ACMB8CB and lock power factory installed b Two 2 isolated power inputs One 1 to power the ACM8 ACMS8CB and one 1 for lock accessory power external power supply is required Current is determined by the power supply connected not to exceed a maximum of 10 amp total e Eight 8 Access Control System trigger inputs Input options a Eight 8 normally open NO inputs b Eight 8 open collector inputs c Any combination of the above e Eight 8 independently controlled outputs Output options a Eight 8 Fail Safe and or Fail Secure power outputs b Eight 8 form C 5 amp rated relay outputs AL1024ULACM only c Any combination of the above e Eight 8 auxiliary power outputs unswitched e Output ratings Fuses are rated 3 5 amp AL1024ULACM PTCs are rated 2 5 amp AL1024ULACMCB e Input 115VAC 60Hz rated 4 4 amp e ACM8 board main fuse is rated at 10 amp e Filtered and electronically regulated outputs built in power supply Short circuit and thermal overload protection Red LEDs indicate outputs are triggered relays energized Fire Alarm disconnect latching or non latching is individually selectable for any or all of the eight 8 outputs Fire Alarm disconnect input options a Normally open NO or normally closed NC dry contact input b Polarity reversal input from FACP signaling circuit
Download Pdf Manuals
Related Search
Related Contents
L`avion jouet témoin de son temps. info on the effort not listed here. for example list LE GUIDE DU MOULAGE - Aviatorwatch.ch Copyright © All rights reserved.
Failed to retrieve file