Cisco 8GB DDR3-1333
Contents
1. bee E Cordset rating 10 A 250 V ength 8 2 ft Connector IEC60320 C13 n Cordset rating 13A 250V a a 79 2m Plug EL312MoldedTwistlock NEMA L6 20 Ee sean 3 8 Tl ca e IT Cordset rating 10A 250V 686mm Plug SS10A 2500 mm Cordset rating 10 A 250 500 V MAX i Length 8 2 ft Plug EL 219 IRAM 2073 Connector EL 701 IEC60320 C13 alli v4 VA UU Ki Cordset rating 10 A 250 V 500 V MAX 7 SN Length 2500mm D Connector a EL 701C EN 60320 C15 g BS IBEA i AME fuse 29 CONFIGURING the SERVER Table 13 Available Power Cords Product ID PID PID Description Images SFS 250V 10A CN Power Cord SFS 250V 10A China os h Cordset rating 10A 250V Plug 2500 mm EL 218 CCEE GB2009 Connector EL 701 e IEC60320 C13
2. SATA DVD drive oa VGA connector Power supply status LED USB ports 3 DE Memory status LED Figure 3 is a detailed view of operator panel Cisco UCS C460 M2 High Performance Rack Mount Server DETAILED VIEWS Figure 3 Chassis Front View Power status LED ID button Power button HDD fault LED Reset button System health LED 9 NMI button Cisco UCS C460 M2 High Performance Rack Mount Server 5 DETAILED VIEWS Chassis Rear View Figure 4 shows the external features of the rear panel Figure 4 Chassis Rear View ri J JE NODE XT 3L 2IRSDZARSIDAN VAGINA OSDO TNA U 2EXIDARCIDAKK WK US VAT UV Um DS SOCON Ii ID TI 198384 Power supplies up to 4 10G SFP LOM ports two total USB ports 2 total 10 100 Management ports M1 and M2 10GBase T LOM ports two total PCle slots 1 through 10 left to right as shown SAS riser slot Power supply LEDs m VGA connector Serial connector 6 Cisco UCS C460 M2 High Performance Rack Mount Server BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capabilit
3. CAB 9K10A EU Power Cord 250VAC 10A CEE 7 7 Plug EU A SFS 250V 10A ID Power Cord SFS 250V 10A India Z As rn 3 Pug Cor i ratin Ale 250V SFS 250V 10A IS Power Cord SFS 250V 10A Israel Cordset MAX E IEC60320 C13 CAB 9K10A IT Power Cord 250VAC 10A CEI 23 16 VII Plug Italy TUTTI mmm Inn TIE i Cordset rating 10 A 250 V tin Plug Length 8 ft 2 in 2 5 m Connector 3G C15M CEI 23 16 EN60320 C15 CAB 9K10A SW Power Cord 250VAC 10A MP232 Plug Switzerland i n 205 E a CAB 9K10A UK Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK RE Jd Cordset rating 10 A 250 V 500 V MAX Z S 7 Length 2500mm R Pr U Connector I a EL 701C EN 60320 C15 lt BS 8 T id we fuse 30 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Table 13 Available Power Cords Product ID PID PID Description Images CAB 9K12A NA Power Cord 125VAC 13A NEMA 5 15 Plug North America CAB C13 C14 2M Power Cord J umper C13 C14 Connectors 2 Meter Length CAB J PN 3PIN Power Cord 3PIN J apan Image not available Cisco UCS C460 M2 High Performance Rack Mount Server 31 CONFIGURING the SERVER STEP 10 ORDER OPTIONAL CABLE MANAGEMENT ARM
4. A tool less slide rail kit PID RC460 SLDRAIL is included with the C460 M2 server The cable management arm attaches to the left and right slide rails at the rear of the server and is used for cable management You can order the cable management arm listed in Table 14 Table 14 Cable Management Arm Product ID PID PID Description RC460 CBLARM Cable Management Arm for C460 32 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 11 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE One or two optional 2 GB eUSB drives may be ordered and used as a boot drive The eUSB drives plug into vertical USB slots on the motherboard You can order the eUSB boot drive listed in Table 15 Table 15 Available USB Drive Product ID PID PID Description di Capacity ype RC460 EUSB 2 GB eUSB Drive USB 2 GB Approved Configurations B Select one or two eUSB drives from Table 15 Caveats None Cisco UCS C460 M2 High Performance Rack Mount Server 33 CONFIGURING the SERVER STEP 12 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims
5. Clock speed 1066 MHz Ranks per DIMM 2 or 4 Operational voltage 1 5 or 1 35 V Registered B Each CPU controls four serial memory interface SMI channels Memory buffers on the memory risers convert each SMI channel into two DDR3 subchannels There are two memory risers for each CPU Memory is organized as two paired DIMM kits 4 DIMMs per memory channel as shown in Figure 5 Cisco UCS C460 M2 High Performance Rack Mount Server 13 CONFIGURING the SERVER Figure 5 C460 M2 Memory Organization Memory Riser 1 Memory Riser 3 Riser slats Riser slots 1B 10 1B 1D Memory buffer Riser slots TA IC Memory buffer Riser slots 1A 1C Chan 1 Chan 1 Riser slots Riser slats 2B 2D 2B 2D Riser slats ZA 2C Riser slats 1B 1D Memory buffer Memory buffer Riser slots 2A AC Chan 2 Memory Riser 2 Memory Riser 4 Riser slots 16 1D Riser slots Memory buffer TA 1C Memory buffer Riser slots TA 1E Riser slots Riser slots 2B 2D 28 2D Riser slats 3 l l 2A 2C Memory buffer Riser slats 5 2A 2C Riser slots Memory Riser 5 Memory Riser 7 1B 1D x 1 Riser slots Riser slots Memory buffer 1A IC Memory buffer Riser slots 1A 1C Chan 1 Riser slots Riser slots B 20 2B 2D i Riser slots Memory buffer 2A x d Memory buffer Riser slots han 2A 2C Riser slats 1B 10 Memory Riser 8 Riser slots
6. C to 70 C 40 F to 158 F Altitude 30 m to 1500 m 100 ft to 5000 ft Humidity nonoperating 95 noncondensing at temperatures of 259C 779F to 309C 869F Compliance Requirements The regulatory compliance requirements for C Series servers are listed in Table 30 Table 30 UCS C Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Immunity EN55024 CISPR24 EN300386 KN24 52 Cisco UCS C460 M2 High Performance Rack Mount Server TECHNICAL SPECIFICATIONS Cisco UCS C460 M2 High Performance Rack Mount Server 53 TECHNICAL SPECIFICATIONS staende CISCO Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Sys
7. Redhat Svcs Included RHEL 2 Socket 1 Guest 3Yr Subscription Redhat Svcs Included RHEL 2 Socket 2 Guest 3Yr Subscription Redhat Svcs Included RHEL 2 Socket 4 Guest 1Yr Subscription Redhat Svcs Included RHEL 2 Socket U Guest 1Yr Subscription Redhat Svcs Included RHEL 2 Socket U Guest 3Yr Subscription Redhat Svcs Included RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 3 Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Redhat Svcs Incld RHEL Option Resilient Storage 2 Socket 1 Yr Redhat Svcs Incl Cisco UCS C460 M2 High Performance Rack Mount Server 35 CONFIGURING the SERVER Table 17 Operating Systems continued PID Description RHEL SFS 2S 1A RS RHEL HA 2S 3A RS RHEL RS 2S 3A RS RHEL SFS 2S 3A RS Windows Server MSWS 08 STHV MSWS 08 ENHV MSWS 08R2 STHV MSWS 08R2 ENHV MSWS 08R2 DCHV2S MSWS 08R2 DCHV4S VMWare Server VMW VS ADV 1A VMW VS ADV 3A VMW VS ENT 1A VMW VS ENT 3A VMW VS ENTP 1A VMW VS ENTP 3A VMW VCS 1A VMW VCS 3A Product ID PID RHEL Option Scalable File Sys 2 Socket 1 Yr Redhat Svcs Incl RHEL Option High Availability 2 Socket 3Yr Redhat Svcs Incld RHEL Option Re
8. Riser slots ae 1A TC Memory buffer Riser slots 1A 1C Riser slats 4B 2D Riser slats Memory buffer 2A 2C Riser slots 2B 2D Memory buffer 64 DIMMS 1 TB maximum memory 4 memory channels per CPU up to 4 DIMMs per channel 14 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Choose Memory Riser Boards You may choose four memory riser boards for a two CPU system or eight memory riser boards for a four CPU system Table 4 Available Memory Riser Boards Product ID PID PID Description Max DIMMs per Riser Riser Board Options UCSC MRB 002 C460 Memory riser board for C460 m2 server only 8 Approved Configurations 1 Two CPU System m Choose four memory riser boards from Table 4 1 Four CPU System m Choose eight memory riser boards from Table 4 Caveats m You should order enough risers with enough sockets to accommodate your maximum forseeable memory needs Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The available memory DIMMs and mirroring option are listed in Table 5 o NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft err
9. 24 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Copper twinax cables are listed in Table 10 You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to improve signal quality Table 10 Available Twinax Cables Product ID PID PID Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H10GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered m You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 10 can be ordered only for the following PCle cards _N2XX ACPCIO1 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCS PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AEPCIO1 Emulex OCe10102 F N2XX
10. Adapters HBAs Choose PCle Option Cards The available PCle option cards are listed in Table 8 Table 8 Available PCle Option Cards Product ID PID PID Description Card Height Converged Network Adapters CNA N2XX ACPCIO1 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps Full N2XX AEPCIO1 Emulex OneConnect OCe10102 F CNA 2 port 10Gbps Half UCSC PCIE BSFP Broadcom NetXtreme Il 57712 Dual Port 10 Gigabit Ethernet PCIe Half Adapter Card with SFP Network Interface Cards NICs N2XX ABPCIO2 Broadcom 57711 Dual Port 10GbE NIC w TOE iSCSI Half N2XX ABPCIO3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI Half N2XX AQPCIO1 Qlogic QLE 8152 CNA 2port 10Gb SFP Copper Half N2XX AIPCIO2 Intel Quad port GbE Controller E1G44ETG1P20 Half N2XX AIPCIO1 Intel Dual Port 10 GbE Ethernet X520 Server Adapter Half N2XX AMPCIO1 Mellanox ConnectX 2 EN with dual 10GbE SFP ports Half Host Bus Adapters HBAs N2XX AEPCI03 Emulex LPe 11002 4Gb Fibre Channel PCle Dual Channel HBA Half N2XX AEPCIO5 Emulex LPe 12002 8Gb dual port Fibre Channel HBA Half N2XX AQPCIO3 Qlogic QLE2462 4Gb dual port Fibre Channel HBA Half N2XX AQPCIO5 Qlogic QLE2562 8Gb dual port Fibre Channel HBA Half Approved Configurations 1 Select up to 10 PCle Cards 22 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER B Use Table 9 as a guide for adding PCle cards See Figure 6 for the slot locations Table 9 PCle Expansion Slot Numbe
11. Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible For optimal performance distribute DIMMs evenly across all installed CPUs and memory buffers DIMMs within a channel are populated starting with the DIMMs farthest from the memory buffer in a fill farthest approach Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations For more information about memory see CPUs and DIMMs on page 46 Cisco UCS C460 M2 High Performance Rack Mount Server 17 CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs The standard disk drive features are B 2 5 inch small form factor B Hot pluggable B Sled mounted Choose Drives The available drives are listed in Table 6 Table 6 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID HDDs A03 D073GC2 PID Description Drive Type Capacity 73GB 6Gb SAS 15K RPM SFF HDD A03 D146GC2 A03 D300GA2 A03 D500GC3 A03 D600GA2 UCS HDD900GI2F106USD A03 D1TBSATA 146 GB SAS 15K RPM SFF HDD 300 GB 6 Gb SAS 10K RPM SFF HDD 500 GB 6 Gb SATA 7 2K RPM SFF 600 GB 6 Gb SAS 10K RPM SFF HDD 900GB 6Gb SAS 10K RPM SFF HDD SAS SAS SAS SATA SAS SAS 13 GB 146 GB 300 GB 500 GB 600 GB 900 GB 1 TB SATA 7 2K RPM SFF HDD SSDs UCS SSD100GI1F104 UCS SD100GOKA2 EUSD UCS SD200GOKA2 EUSD UCS SD300GOKA2 EUSD NEW 100GB SATA SSD SFF STEC 100GB Std 15mm Z SATA SSD 200GB
12. Std Height 15mm SATA SSD 300GB Std Height 15mm SATA SSD Approved Configurations 1 LSI MegaRAID SAS 9260 8i RAID controller battery backup is optional SATA SATA SATA SATA SATA 1 TB 100 GB 100 GB 200 GB 300 GB m Select up to 12 SAS or SATA drives listed in Table 6 you can mix SAS SATA drives but not HDD SSD drives This configuration supports RAID 0 1 5 6 and 10 2 LSI MegaRAID SAS 9240 8i RAID controller no battery backup 18 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER B Select up to 8 SAS or SATA drives listed in Table 6 you can mix SAS SATA drives but not HDD SSD drives This configuration supports RAID Oand 1 Caveats B You cannot mix HDDs and SSDs Cisco UCS C460 M2 High Performance Rack Mount Server 19 CONFIGURING the SERVER STEP 5 CHOOSE RAID CONFIGURATION The C460 M2 server accommodates either an LSI MegaRAID SAS 9260 8i or LSI MegaRAID SAS 9240 8i RAID controller The C460 M2 contains a drive bay housing up to 12 HDDs or SSDs Cisco can provide factory configured RAID 0 1 5 6 and 10 systems depending on the RAID Implementation chosen the RAID controller chosen and the number of drives ordered Factory configured RAID options are listed at the end of Table 7 Note that RAID levels 50 and 60 are supported on the 9260 8i but are not factory configurable Choose RAID Options Choose one RAID controller one RAID configuration option
13. and if desired the battery backup option listed in Table 7 Table 7 Available RAID Options Product ID PID PID Description RAID Controllers RC460 PLO01 LSI MegaRAID SAS 9260 8i RAID 0 1 5 6 10 50 60 supported m Plugs into the dedicated SAS riser on the rear of the server on the left see Figure 4 on page 6 m Supports from 1 to 12 internal SAS or SATA drives m Battery backup option available see the battery backup PID section in this table m Factory configured RAID options RAID 0 1 5 6 10 see the RAID PIDs section in this table RC460 PL002 LSI MegaRAID SAS 9240 8i RAID 0 and 1 m Plugs into the dedicated SAS riser on the rear of the server on the left see Figure 4 on page 6 m Supports from 1 to 8 internal SAS or SATA drives m Battery backup option not available m Factory configured RAID options RAID 0 and 1 see the RAID PIDs section in this table RAID Battery Backup Option R2XX LBBU2 Battery Backup for LSI MegaRAID SAS 9260 8i controller only RAID Configuration R2XX RAIDO Factory pre configured RAID striping option Enable RAID 0 Setting Requires a minimum of 1 hard drive R2XX RAID1 Factory pre configured RAID mirroring option Enable RAID 1 Setting Requires exactly 2 drives with same size speed capacity 20 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Table 7 Available RAID Options continued Product ID PID PID Description R2XX RA
14. and 8 Cisco UCS C460 M2 High Performance Rack Mount Server 7 BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Storage controller Factory configured RAID support options m RAID 0 1 5 6 10 50 and 60 support for up to 12 SAS or SATA drives with either the optional LSI MegaRAID SAS 9260 8i controller or m RAID 0 and 1 support for up to 8 SAS or SATA drives with the optional LSI MegaRAID 9240 81 RAID controller There is a dedicated SAS riser slot in the chassis for either RAID controller card There is also a location inside the chassis for the optional LSI RAID battery backup unit that can be used with the 9260 81 controller card Internal storage devices Up to 12 SFF 2 5 SAS or SATA hard disk drives HDDs or solid state drives SSDS Video The server CIMC chip includes a Matrox G200 core The first 8 MB of memory are allocated to the video core m 1280 x 1024 resolution m 32 bit color depth m 8 MB video memory Interfaces m Rear panel Two 10 100 dedicated management Ethernet ports Two 1 Gigabit These integrated Gigabit ports support the Wake on LAN WoL and TCP IP Offload Engine TOE standards Two 10 Gigabit Base T Ethernet ports Two 10 Gigabit SFP Ethernet ports One RS232 serial connector One 15 pin VGA connector Two USB 2 0 connectors m Front panel One 15 pin VGA connector Three USB 2 0 connec
15. that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards Unified Computing Mission Critical Service This service delivers personalized technical account management expedited technical support and expert field support engineering for the Cisco Unified Computing System UCS The Mission Critical Support Service provides a designated technical account manager TAM who acts as a strategic resource to help ensure that the unified computing environment runs at peak efficiency If a problem arises that threatens business continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical Assistance Center TAC Please note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed in Table 20 Table 20 Unified Computing Mission Critical Service Product ID PID On Site Description CON UCM7 C460 M2 Yes UC Mission Critical 24x7x4 On site CON UCMS8 C460 M2 Yes UC Mission Critical 24x7x2 On site Unified Computing Support Service For support of the entire Unified Computing System Cisco offers the Cisco Unified Computing Support Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Acce
16. to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 16 Table 16 Trusted Platform Module Product ID PID PID Description UCSC TPM 001 C460 Trusted Platform Module 34 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 13 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose Choose one of the operating systems listed in Table 17 Table 17 Operating Systems PID Description Product ID PID SUSE Linux Enterprise Server SLES 1A SLES 3A SLES 1yr subscription svcs required 0 media SLES 3yr subscription svcs required 0 media Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2S 1G 3A RHEL 2S 4G 1A RHEL 2S 4G 3A RHEL 2S UG 1A RHEL 2S UG 3A RHEL 2S 1G 1A RS RHEL 2S 1G 3A RS RHEL 2S 4G 3A RS RHEL 2S 4G 1A RS RHEL 2S UG 1A RS RHEL 2S UG 3A RS RHEL Add Ons RHEL HA 2S 1A RHEL RS 2S 1A RHEL SFS 2S 1A RHEL HA 2S 3A RHEL RS 2S 3A RHEL SFS 2S 3A RHEL HA 2S 1A RS RHEL RS 2S 1A RS RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL 2 Socket 1 Guest 1Yr Subscription
17. 9000 9 e cesso 0000000 900000000900090 Em i Rear View a mmm LI Em mS 0 ea ae i di ES i NT be a n 3 lj 5 PI EG m ma D n D nn li e 00000008 L Sie B Sa LETO Sete UB ON Lid 4l Hp i i LE Ii n n Y BU T 1 E D um LL EZ yy v39 19 5 ES Perl PSU 4 OAs PSU 3 OA PSU 2 OAS PSU 1 B Hr 9082 ES Boc os vide Bi mm er Bom mag am ia P mM r Sui nua dini umau a LA Cisco UCS C460 M2 High Performance Rack Mount Server DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS C460 M2 General Purpose Rack Server Chassis Front View Figure 2 3203 LPF 25 5 5 5 gt gt CN De D C OSSIA nl I f I f hi ON rez age r gi Bigi 8 986l EEE IDO CO L I I ES gt Operations panel see Figure 3 on page 5 for a detailed view O LLI sol un 3 4 o J un 2 A O Network activity LED all L If I 5 la JA E nl MA IE 1 g A e Bed PE N HO O EE CSD Bex ali fo elle eJ I f i i pe
18. AIPCIO1 Intel Dual Port Ethernet X520 N2XX AQPCIO1 Qlogic QLE 8152 CNA Cisco UCS C460 M2 High Performance Rack Mount Server 25 CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 11 Table 11 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered B You may choose one or two SFP optical modules cables for each network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See Figure 7 on page 27 for typical SFP and twinax connections to the network cards Caveats The SFP 10G SR optical module listed in Table 11 can be ordered only for the following PCle cards _N2XX ACPCIO1 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AEPCIO1 Emulex OCe10102 F 26 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Figure 7 Network Card Connections Network PCle Card Optical SFP Modules la Fiber Optic Cables sd E Redundant Top of Rack Access Switches si 7J EE Twinax Copper Cab
19. ARE You can select from a variety of value added software listed in Table 18 Table 19 Value Added Software Product ID PID PID Description BMC 001 BMC BladeLogic CM for Virtualized Cisco Servers BMC 001 COMP BMC Blade Logic Compliance VM Bundle 2 Socket Server BMC 002 BMC BladeLogic CM for Physical Cisco Servers BMC 002 COMP BMC Blade Logic Compliance Single OS BMC 003 BMC Bladelogic CM Virtualized 4 Socket Server BMC 003 COMP BMC Blade Logic Compliance VM Bundle 4 Socket Server BMC 012 BMC BPPM Per Server VMW VCS 1A VMware vCenter Server Standard lyr 24x7 support VMW VCS 3A VMware vCenter Server Standard 3yr 24x7 support NIK VLEM UCS 1 Cisco Nexus 1000V License PAK for 1 Virtual Ethernet module N1K CSK9 UCS 404 Cisco Nexus 1000V VSM Virtual Appliance Software 38 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 16 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied B Three year parts coverage Next business day NBD parts replacement eight hours a day five days a week 90 day software warranty on media Downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes
20. ENTAL MATERIAL Figure 10 Cisco R42610 Rack Front view door closed Front view door open Front view door removed Cisco UCS C460 M2 High Performance Rack Mount Server 49 SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units PDUs offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU See Figure 11 Figure 11 Zero Rack Unit PDU PID RP208 30 2P U 2 Breakers C13 plugs EO Cisco RP Series PDU models provide two 20 ampere A circuit breakers for groups of receptacles The effects of a tripped circuit are limited to a receptacle group Simply press a button to reset that circuit 50 Cisco UCS C460 M2 High Performance Rack Mount Server TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 27 UCS C460 M2 Dimensions and Weight Parameter Height Width Depth Front Clearance Side Cleara
21. ID5 Factory pre configured RAID option Enable RAID 5 Setting Requires minimum 3 drives of same size speed capacity R2XX RAID6 Factory pre configured RAID option Enable RAID 6 Setting Requires minimum 4 drives of same size speed capacity R2XX RAID10 Factory pre configured RAID option Enable RAID 10 Setting Requires an even number of drives minimum 4 drives of same size speed capacity NOTE No RAID option can be chosen if you have one of the following configurations o e A mix of SAS and SATA drives e No drives Approved Configurations 1 One RAID Controller Card B Choose either the RC460 PL001 LSI MegaRAID SAS 9260 8i RAID controller or the RC460 PL002 LSI MegaRAID SAS 9240 8i RAID controller listed in Table 7 You will be able to control from 1 to 12 drives with the 9260 8i RAID controller and from 1 to 8 drives with the 9240 8i RAID controller Caveats m The RAID controller card is preinstalled in a dedicated SAS riser slot in the rear of the server See Figure 4 on page 6 B You can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is pre configured at the factory If you do not choose a RAID configuration the disks will be configured as a J BOD Cisco UCS C460 M2 High Performance Rack Mount Server 21 CONFIGURING the SERVER STEP 6 CHOOSE PCle OPTION CARD S The standard PCle card offerings are B Converged Network Adapters CNA m Network Interface Cards NICs B Host Bus
22. OPTIONAL STEP ORDER RACKS 2 000 cee eee eee eee eee 43 OPTIONAL STEP ORDER PDU 0 nn nn nn nnnm ee 44 SUPPLEMENTAL MATERIAL eene 45 SEES ES EEE EEE 45 CPUs and DIMMS auaa 46 PO eee ee On alain 46 Memory Population Rules auaa 0 a 46 RACKS dare enS adt OR ee eee e EE ey 48 POUS ee eae ratti 50 TECHNICAL SPECIFICATIONS 2 00 cee ee eee ee 51 Dimensions and Weight 51 Power Specifications 51 Environmental Specifications LL 52 Compliance Requirements lee ehh hs hi sh s rns 52 Cisco UCS C460 M2 High Performance Rack Mount Server OVERVIEW OVERVIEW The Cisco UCS C460 M2 High Performance Rack Server Figure 1 is a four rack unit 4RU server supporting the Intel Xeon processor E7 4800 and E7 8800 product families with up to 1 terabyte TB of double data rate 3 DDR3 memory in 64 slots and up to 12 small form factor SFF hot pluggable SAS and SATA disk drives 10 PCI Express PCle slots support the Cisco UCS C Series network adapters with an eleventh PCle slot reserved for a hard disk drive array controller card Additional I O is provided by 2 Gigabit Ethernet LOM ports 2 10 Gigabit Ethernet ports and 2 dedicated out of band OOB management ports Figure 1 Cisco UCS C460 M2 High Density Rack Server Front View U 0000000000 VE EE SEE EEE RR 9009000909000000090900000909 9090900000000000000009000090 000000000000000000000000 X 090000000
23. SFF UCWD6 8x5x4 Onsite CON UCWD6 C460 M2SFF UCWD7 24x7x4 Onsite CON UCWD7 C460 M2SFF UCWD8 24x7x2 Onsite CON UCWD8 C460 M2SFF For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 ps10321 Cisco UC Warranty Support DS pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv group home html 42 Cisco UCS C460 M2 High Performance Rack Mount Server OPTIONAL STEP ORDER RACKS OPTIONAL STEP ORDER RACKS The optional R42610 rack is available from Cisco for the C Series servers including the C460 M2 server This rack is a standard 19 inch rack and can be ordered with a variety of options as listed in Table 24 Racks are shipped separately from the C460 M2 server Table 24 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 RACK FASTEN 001 RACK FASTEN 002 RACK J OIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 M6 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements For more information about the R42610 rack see RACKS o
24. d 2D buffer 2 subchannel 1 4 Slots 2A and 2C buffer 2 subchannel 2 Cisco UCS C460 M2 High Performance Rack Mount Server 47 SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 10 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment B Cisco UCS B Series servers and fabric interconnects B Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for ElA standard 19 inch racks Rack specifications are listed in Table 26 Table 26 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 299 83 Ib 136 kg 354 Ib 161 kg Yes 42RU 2100 Ib 954 kg Not applicable Expansion Rack 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 Ib 105 ko 284 Ib 129 ko No 42RU 2100 Ib 954 kg Not applicable o NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet 48 Cisco UCS C460 M2 High Performance Rack Mount Server SUPPLEM
25. ge 20 STEP 6 CHOOSE PCle OPTION CARD S page 22 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 25 STEP 8 ORDER POWER SUPPLIES page 28 STEP 9 SELECT AC POWER CORD s page 29 STEP 10 ORDER OPTIONAL CABLE MANAGEMENT ARM page 32 STEP 11 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE page 33 STEP 12 ORDER A TRUSTED PLATFORM MODULE page 34 STEP 13 CHOOSE OPERATING SYSTEM page 35 STEP 14 CHOOSE OPERATING SYSTEM MEDIA KIT page 37 STEP 15 CHOOSE OPTIONAL VALUE ADDED SOFTWARE page 38 STEP 16 CHOOSE SERVICE and SUPPORT LEVEL page 39 OPTIONAL STEP ORDER RACKS on page 43 OPTIONAL STEP ORDER PDU on page 44 10 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID PID of the base server as shown in Table 2 Table 2 PID of the Base C460 M2 Rack Server Product ID PID Description UCSC BASE M2 C460 UCS C460 M2 Rack SVR w o CPU Mem HDD PCIe The C460 BASE 2646 base server B Includes Two 850 W power supplies Four empty memory riser boards 2 CPU systems or 8 empty memory riser boards 8 CPU systems Blanking panels for empty drive locations to maintain cooling air flow Tool less rail kit Cable management arm B Does not include CPUs hard disk drives HDDs solid state Drives SSDs or plug in PCle cards o NOTE Use the steps on the following pages to configure the server with the components that you want to incl
26. les Redundant Top of Rack Access Switches mum IS Ten Cisco UCS C460 M2 High Performance Rack Mount Server 27 CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLIES If you ordered a 2 CPU system the base server comes with two power supplies which is adequate to power the server If you ordered a 4 CPU system you must order two additional power supplies listed in Table 14 Table 12 Power Supplies Product ID PID PID Description RC460 PSU2 850W 850W POWER SUPPLY UNIT FOR C SERIES C460 28 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD s Select the appropriate AC power cords listed in Table 13 You may select a minimum of no power cords and a maximum of two power cords If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 13 Available Power Cords Product ID PID R2XX DMYMPWRCORD CAB N5K6A NA CAB AC 250V 13A CAB C13 C14 MPR SFS 250V 10A AR CAB 9K10A AU PID Description No power cord dummy PID to allow for a no power cord option Power Cord 200 240V 6A North America Power Cord NEMA L6 20 250V 20A plug IEC320 C13 receptacle North America Power Cord recessed receptacle AC power cord 27 Power Cord SFS 250V 10A Argentina Power Cord 250VAC 10A 3112 Plug Australia Cisco UCS C460 M2 High Performance Rack Mount Server Images Not applicable
27. lities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 23 NOTE Cisco does not offer a certified drive destruction service as part of this service o Table 23 Drive Retention Service Options Service Service Service Description Program Name Level GSP Service Level Product ID PID UCS Mission Critical UC CRIT DR UCMD7 24x7x4 Onsite CON UCMD7 C460 M2SFF Support Service With Drive Retention UCMD8 24x7x2 Onsite CON UCMD8 C460 M2SFF UCS Support UC SUPP DR UCSD1 8x5xNBD CON UCSD1 C460 M2SFF Service With Drive Retention UCSD2 8x5x4 CON UCSD2 C460 M2SFF UCSD3 24x7x4 CON UCSD3 C460 M2SFF UCSDA 24x 7x2 CON UCSD4 C460 M2SFF UCSD5 8x5xNBD Onsite CON UCSD5 C460 M2SFF UCSD6 8x5x4 Onsite CON UCSD6 C460 M2SFF UCSD7 24x7x4 Onsite CON UCSD7 C460 M2SFF UCSD8 24x7x2 Onsite CON UCSD8 C460 M2SFF Cisco UCS C460 M2 High Performance Rack Mount Server 41 CONFIGURING the SERVER Table 23 Drive Retention Service Options continued Service Service Service Description Program Name Level GSP Service Level Product ID PID UCS Warranty Plus UC PLUS DR UCWD2 Ox5x4 CON UCWD2 C460 M2SFF With Drive Retention UCWD3 24x7x4 CON UCWD3 C460 M2SFF UCWD4 24x7x2 CON UCWD4 C460 M2SFF UCWD5 8x5xNBD Onsite CON UCWD5 C460 M2
28. mory riser The physical layout of a memory riser is shown in Figure 9 Figure 9 Memory Riser Physical Layout 1 Memory buffer 1 E Memory buffer 2 In Figure 9 the buffers and channels are Buffer 1 subchannel 1 slots 1B and 1D Buffer 1 subchannel 2 slots 1A and 1C Buffer 2 subchannel 1 slots 2B and 2D Buffer 2 subchannel 2 slots 2A and 2C Memory Population Rules When considering the memory configuration of your server you should observe the following B The minimum configuration for the server is at least one matched DIMM pair installed in a memory riser on either CPU1 or CPU2 All four CPUs can run from a single DIMM pair B DIMMs are required to be populated in pairs DIMMs for this server are configured as two DIMM kits 46 Cisco UCS C460 M2 High Performance Rack Mount Server SUPPLEMENTAL MATERIAL B The DIMMs in any given pair must be identical B Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible B For optimal performance distribute DIMMs evenly across all installed CPUs and memory buffers B DIMMs within a subchannel are populated starting with the DIMMs farthest from the memory buffer in a fill farthest approach B For example the order that you should populate the four channels on a memory riser is as follows see also Figure 9 on page 46 1 Slots 1B and 1D buffer 1 subchannel 1 2 Slots 1A and 1C buffer 1 subchannel 2 3 Slots 2B an
29. n page 48 Cisco UCS C460 M2 High Performance Rack Mount Server 43 OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC460 M2 server This PDU is available in a zero rack unit RU style see Table 24 Table 25 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUs on page 50 44 Cisco UCS C460 M2 High Performance Rack Mount Server SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C460 M2 chassis with the top cover removed is shown in Figure 8 Figure 8 C460 M2 With Top Cover Removed m PCle slots SAS riser slot 10 9 8 7 6 5 4 3 2 1 3 ix a E i M Li w zi L CPU 4 CPU 3 CPU 2 CPU 1 EN CPU1 CPU2 CPU3 CPU4 beneath cover tif Memory Risers 8 4 Fan Modules up to 8 IJ Disk Drives up to 12 Front Panel Cisco UCS C460 M2 High Performance Rack Mount Server 45 SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Each CPU controls four serial memory interface SMI channels see Figure 5 on page 14 There is one memory riser for every two channels There are therefore two memory risers per CPU Each CPU channel drives a memory buffer on a riser card and each memory buffer converts a CPU SMI into two DDR3 subchannels that each read and write two DIMM pairs on a me
30. nce Rear Clearance Value 6 8 in 174 mm 16 7 in 424 mm 27 7 in 704 mm 3 in 7 62 cm lin 25 4 mm 6 in 152 4 mm Weight maximum configuration including slide 110 23 Ibs 50 kg rail brackets and cable management arm Notes 1 The system weight given here is an estimate for a fully configured system and will vary depending on the number of peripheral devices and power supplies Power Specifications The general power specifications for the C460 M2 server are listed in Table 28 Table 28 UCS C460 M2 Power Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for each power supply Power supply output voltage Power supply efficiency 100 to 127 VAC nominal Range 90 to 264 VAC 50 to 60 Hz nominal Range 47 to 63 Hz 9 A at 100 VAC 30 A peak sub cycle duration 850 W Main power 12 VDC Standby Power 5 VDC 92 Peak complies with 80Plus Gold Standard o NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet Cisco UCS C460 M2 High Performance Rack Mount Server 51 TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C460 M2 server are listed in Table 29 Table 29 UCS C460 M2 Environmental Specifications Parameter Minimum Temperature operating 10 C to 35 C 50 F to 95 F Temperature nonoperating 40
31. or in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Cisco UCS C460 M2 High Performance Rack Mount Server 15 CONFIGURING the SERVER DIMMs are orderable as kits with two DIMMs per kit Choose the desired number of DIMMs and the memory mirroring option if desired The available memory DIMMs are listed in Table 5 Table 5 Available DDR3 DIMM Kits 2 DIMMs per Kit Product ID PID PID Description Voltage V EAE D DIMM Options UCS MR 2X041RX C 2X4GB DDR3 1333 MHz RDIMM PC3 10600 single rank x1 1 35v 1 5 1 35 A02 M308GB3 2 8GB DDR3 1333MHz RDIMM PC3 10600 2x4GB 2R Kit Low Volt 1 5 1 35 A02 M308GD5 2 8GB DDR3 1333MHz RDIMM PC3 10600 2x4GB 2R Kit 1 5 UCS MR 2X082RX C 2X8GB DDR3 1333 MHz RDIMM PC3 10600 dual rank x2 1 35v 1 5 1 35 A02 M316GB3 2 16GB DDR3 1333MHz RDIMM PC3 10600 2x8GB 2R Kit Low Volt 1 5 1 35 A02 M316GD5 2 16GB DDR3 1333MHz RDIMM PC3 10600 2x8GB 2R Kit 1 5 UCS MR 2X164RX C 2X16GB DDR3 1333 MHz RDIMM PC3 10600 quad rank x4 1 35v 1 5 1 35 A02 M332GB3 2 L 32GB DDR3 1066MHz RDIMM PC3 8500 2x16GB 4R Kit Low Volt 1 5 1 35 RR AA NO NO N N N HI Memory Mirroring Option NO1 MMIRROR Memory mirroring option Approved Config
32. ring Slot Number Slot Characteristics 1 and 2 PCle Gen 2x8 3 4 length card x24 hot swappable connectors 3 and 4 PCle Gen 2x4 1 2 length card x8 connectors 5 PCle Gen 2x16 3 4 length card x16 connector 6 and 7 PCle Gen 2x8 3 4 length card x8 hot swappable connectors 8 PCle Gen 1x4 3 4 length card x8 connector 9 PCle Gen 1x4 1 2 length card x8 connector 10 PCle Gen 2x4 1 2 length card x8 connector Figure 6 PCle Slot Locations da om SH x Nec 18071 EA Cisco UCS C460 M2 High Performance Rack Mount Server 23 CONFIGURING the SERVER Caveats B CPU3 must be installed to support PCle slots 5 6 7 9 and 10 B Legacy I O devices such as video cards are only supported on slots 1 2 3 4 and 8 B The Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface Card N2XX ACPCI01 that is installed in PCIe slot 1 B The C460 server accommodates two P81E Virtual Interface cards VICs These cards are supported only in slots 1 and 2 Note however that if the server is running UCSM only slot 1 is supported for the VIC card B All PCle slots are standard height and require a standard height mounting bracket on the PCle card B To help ensure that your operating system is compatible with the cards you have selected please check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod technical reference list html
33. silient Storage 2 Socket 3 Yr Redhat Svcs Incl RHEL Option Scalable File Sys 2 Socket 3 Yr Redhat Svcs Incl Windows Svr 2008 ST media 1 4CPU 5CAL Windows Svr 2008 EN media 1 8CPU 25CAL Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL Windows Svr 2008 R2 2 CPU Data Center Windows Svr 2008 R2 4 CPU Data Center VMware vSphere Advanced 1 CPU lyr 24x7 support VMware vSphere Advanced 1 CPU 3yr 24x7 support VMware vSphere Enterprise 1 CPU lyr 24x7 support VMware vSphere Enterprise 1 CPU 3yr 24x7 support VMware vSphere Enterprise Plus 1 CPU lyr 24x7 support VMware vSphere Enterprise Plus 1 CPU 3yr 24x7 support VMware vCenter Server Standard lyr support required VMware vCenter Server Standard 3yr support required Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 14 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 18 Table 18 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08RS ENHV RM MSWS 08R2 DCHV RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Media Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media Cisco UCS C460 M2 High Performance Rack Mount Server 37 CONFIGURING the SERVER STEP 15 CHOOSE OPTIONAL VALUE ADDED SOFTW
34. ss to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Unified Computing Support Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain Cisco UCS C460 M2 High Performance Rack Mount Server 39 CONFIGURING the SERVER optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 21 Table 21 UCS Computing Support Service Product ID PID On Site Description CON UCS1 C460 M2 No UC Support 8X5XNBD CON UCS2 C460 M2 No UC Support 8X5X4 CON UCS3 C460 M2 No UC Support 24x7x4 CON UCS4 C460 M2 No UC Support 24x7x2 CON UCS5 C460 M2 Yes UC Support 8X5XNBD CON UCS6 C460 M2 Yes UC Support 8X5X4 CON UCS7 C460 M2 Yes UC Support 24x7x4 CON UCS8 C460 M2 Yes UC Support 24x7x2 Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service You can choose from several levels of advanced parts replacement coverage including onsite par
35. stoorde Spec Sheet CISCO Cisco UCS C460 M2 High Performance Rack Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 8 APRIL 24 2012 WWW CISCO COM CONTENTS OVERVIEW 333 ad d 30303 4 TT TATA 3 DETAILED VIEWS can oe we RO ec En EE e COCOS KE e cae 4 Chassis Front VIEW uua xod dre dd dodo iiri t Y dea NT 4 Chassis Rear VIEW 6 BASE SERVER STANDARD CAPABILITIES and FEATURES 0 0000 neue 7 CONFIGURING the SERVER eee eee eee eee eee eee 10 STEP X VERIFY BASE SKUs a acra dew cx Hex cx AHR PN SRS SAT a ee ew 11 Step ZCHOOSECPUISN are cramer oe 9 3 909 TVG 12 STEP 2 CHOOSE MEMORY mn eam dq RE a de ee SEG 13 STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVES O 18 STEP 5 CHOOSE RAID CONFIGURATION RR RR RR Ree 20 STEP 6 CHOOSE PCle OPTION CARD S eR RR eee 22 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES LL 25 STEP BORDER POWER SUPPLIES a aes ded wy dr ed F f eva 28 STEP 9 SELECT AC POWER CORDIS ee RR rs 29 STEP 10 ORDER OPTIONAL CABLE MANAGEMENT ARM LL 32 STEP 11 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE 33 STEP 12 ORDER A TRUSTED PLATFORM MODULE RR te 34 STEP 13 CHOOSE OPERATING SYSTEM RR RR RR rhe 35 STEP 14 CHOOSE OPERATING SYSTEM MEDIA KIT 0 0 0 0 ee eee ee ee 37 STEP 15 CHOOSE OPTIONAL VALUE ADDED SOFTWARE 0 00000 eens 38 STEP 16 CHOOSE SERVICE and SUPPORT LEVEL 39
36. tems Inc and or its affiliates in the U S and other countries A listing of Cisco s trademarks can be found at www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 54 Cisco UCS C460 M2 High Performance Rack Mount Server
37. tors 8 Cisco UCS C460 M2 High Performance Rack Mount Server BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Power subsystem m Either 2 or 4 850 W power supplies m Power supplies are hot swappable rear accessible and redundant as 242 or 3H NOTE You can use 2 power supplies with a 2 CPU configuration In O this case 1 1 redundancy is supported only if your server s overall power consumption can be supported by a single 850W power supply during the failure and hot swap For more information about your server s power consumption use the power calculator accessible at http www cisco com assets cdc content elements flash dataC enter cisco ucs power calculator Fans Chassis m 8 fans hot swappable Power supply m Each of the 4 power supplies is equipped with a fan Integrated management The built in Cisco Integrated Management Controller CIMC GUI or CLI processor interface enables you to monitor the server inventory health and system event logs Cisco UCS C460 M2 High Performance Rack Mount Server 9 CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C460 M2 High Performance Rack Server STEP 1 VERIFY BASE SKU page 11 STEP 2 CHOOSE CPU S page 12 STEP 3 CHOOSE MEMORY page 13 STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs page 18 STEP 5 CHOOSE RAID CONFIGURATION pa
38. ts replacement in as little as two hours Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 22 Table 22 UCS Computing Warranty Plus Service Product ID PID On Site Description CON UCW2 C460 M2 No UC Warranty Plus 8x5x4 CON UCW3 C460 M2 No UC Warranty Plus 24x7x4 CON UCW4 C460 M2 No UC Warranty Plus 24x7x2 CON UCW5 C460 M2 Yes UC Warranty Plus 8X5XNBD CON UCW6 C460 M2 Yes UC Warranty Plus 8X5X4 CON UCW7 C460 M2 Yes UC Warranty Plus 24x7x4 CON UCW8 C460 M2 Yes UC Warranty Plus 24x7x2 40 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised thereby reducing the risk of any potential liabi
39. ude Cisco UCS C460 M2 High Performance Rack Mount Server 11 CONFIGURING the SERVER STEP 2 CHOOSE CPU S The standard CPU features are B Intel Xeon E7 8800 or E7 4800 Westmere EX series CPUs B Intel 7500 chipset and Intel 7510 scalable memory buffer B Cache size of 18 24 or 30 MB Choose CPUs The available CPUs are listed in Table 3 Table 3 Available CPUs Intel Xeon Westmere E7 48xx 88xx Family Intel SD Power Cache LISS DORS Product ID PID Number Freq W Size MB Cores QPI DIMM Clock GHz Support MHz UCS CPU E78837 E7 8837 2 66 130 24 8 6 40 1066 UCS CPU E74870 E7 4870 2 40 130 30 10 6 40 1066 UCS CPU E74860 E7 4860 2 26 130 24 10 6 40 1066 UCS CPU E78867L E7 8867L 2 13 105 30 10 6 40 1066 UCS CPU E74830 E7 4830 2 13 105 24 8 6 40 1066 UCS CPU E74850 E7 4850 2 00 130 24 10 6 40 1066 UCS CPU E74807 E7 4807 1 86 95 18 6 4 80 1066 Approved Configurations 1 Two CPU Configuration B Choose two identical CPUs from Table 3 2 Four CPU Configuration B Choose four identical CPUs from Table 3 Caveats B You must select either two or four identical processors 12 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER STEP 3 CHOOSE MEMORY The standard memory features are B Plug In Memory Riser Boards Bm DIMMs Up to eight DIMMs per riser board Riser boards plug vertically into the motherboard Up to two riser boards per CPU total maximum of eight per system
40. urations 1 Minimum Configuration without memory mirroring B One memory riser with at least one matched DIMM pair The memory riser must be installed in a slot controlled by either CPU1 or CPU2 All four CPUs can run from a single DIMM pair 2 Maximum Configuration without memory mirroring B Eight memory risers with at least one matched DIMM pair per riser 16 DIMMs total and up to four matched DIMM pairs per riser 64 DIMMs total 3 Minimum Configuration with memory mirroring B One memory riser with at least two matched DIMM pairs 4 Maximum Configuration with memory mirroring 16 Cisco UCS C460 M2 High Performance Rack Mount Server CONFIGURING the SERVER Eight memory risers with at least two matched DIMM pairs per riser 16 DIMMs total and up to four matched DIMM pairs per riser 64 DIMMs total o Caveats NOTE There are three memory mirroring modes 1 Intra socket mirroring 2 Inter socket cross memory controller mirroring 3 Inter socket complete master slave mirroring Mirroring mode can be configured using the UCS Manager BIOS Policy RAS Memory tab Each CPU controls four DDR3 channels The minimum DIMM configuration is at least one matched DIMM pair installed in a memory riser on either CPU1 or CPU2 All four CPUs can run from a single DIMM pair DIMMs are required to be populated in pairs DIMMs for this server are available as two DIMM kits The DIMMs in any given pair must be identical
41. y for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER on page 10 Table 1 Capabilities and Features Capability Feature Description Chassis CPU Chipset Memory USB Flash drive Expansion slots Four rack unit 4RU chassis Either 2 or 4 Intel Xeon E7 8800 4800 family processors Two CPU configurations require 2 power supplies Four CPU configurations require 4 power supplies Intel 7500 chipset and Intel 7510 scalable memory buffer Eight slots for memory riser boards Each memory riser can hold up to 8 DIMMs for a maximum DIMM population of 64 DIMMs Maximum memory capacity is 1 TB This is accomplished with 64 DIMMs consisting of 32 DIMM kits 2 32 GB matched DIMMs per kit in a 4 CPU configuration Optional 2 GB internal eUSB flash drives up to 2 can be used as bootable drives There are 10 PCle expansion slots Slots 1 and 2 Gen 2x8 3 4 length card x24 hot swappable connectors Slots 3 and 4 Gen 2x4 1 2 length card x8 connectors Slot 5 Gen 2x16 3 4 length card x16 connector Slots 6 and 7 Gen 2x8 3 4 length card x8 hot swappable connectors Slot 8 Gen 1x4 3 4 length card x8 connector Slot 9 Gen 1x4 1 2 length card x8 connector Slot 10 Gen 2x4 1 2 length card x8 connector NOTE CPU3 must be installed to support PCle slots 5 6 7 9 and O 10 Legacy I O devices like video cards are only supported on slots NE 1 2 3 4
Download Pdf Manuals
Related Search
Related Contents
Page 7 Philips 17IN 27MM 1280X1024 70HZ User Manual Installation Industrial ETHERNET Rail Switch RS20 Benutzerhandbuch Q1 & Q2 deutsch Sunbeam RC2610 Rice Cooker User Manual Conceptronic CINEARPRO conceptos básicos y principios generales sobre prevención de riesgos 別紙 150 Graphique 1 Copyright © All rights reserved.