Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial
Contents
1. Overvoltage Correction Corrects overvoltages to 150V 0 100 load Undervoltage Correction Corrects undervoltages to 100V at full load 90V at 100V nominal Severe Undervoltage Correction Corrects brownouts to 70V 70 load amp 55V 33 load USER INTERFACE ALERTS amp CONTROLS Front panel LCD information and configuration screen offers detailed UPS and site power status and operating FrontPaneh Eee Riyal data plus configuration of voltage frequency operating mode alarm function and a variety of additional options 2 switches control off on power status and alarm cancel operation 2 additional scroll down and scroll up select Switches options enable LCD status viewing and configuration options Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option Alarm Cancel Operation available Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions 7 front panel LEDs indicate line power availability AC to DC conversion battery mode operation inverter mode eco LED Indicators i mode operation bypass mode operation and AC output status SURGE NOISE SUPPRESSION UPS AC Suppression Joule Rating 570 Time UPS Dataline Suppression 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet EMI RFI AC Noise Suppression Yes PHYSICAL ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115
2. Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Load Management Receptacles Two switchable three outlet 5 15 20R load banks INPUT BATTERY Full Load Runtime min 4 min 1800w Half Load Runtime min 12 min 900w Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible BP48V27 2US multi pack compatible Expandable Runtime Description shar e configurations require the use of Tripp Lite s External Battery Configuration Software see Battery Recharge Rate Included Batteries UPS Output Receptacles Surge Suppression Only Less than 3 hours recharge to 90 typical full load discharge Internal UPS Replacement Battery RBC94 2U Cartridge 3 7 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Battery Access Front panel battery access Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning maintains 2 output voltage regulation during brownouts and overvoltages
3. watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Stepdown Transformer Dimensions hwd in ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Stepdown Transformer Dimensions hwd cm ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load con
4. EPO emergency power off Slot for SNMP Web interface Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications PowerAlert Software Included Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time Zero 0 milliseconds in double conversion mode 4 milliseconds economy mode Low Voltage Transfer to Battery 100V at full load 90V full load at 100V nominal setting 70V at 70 load 55V at 33 load Power Setpoint High Voltage Transfer to Battery 150 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode S During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries Green Energy Saving Features High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances ENERGY STAR Qualified WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance i ai U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lit
5. TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 100 127V 2 2kVA 1 8kW On Line Double Conversion UPS Extended Run SNMP Webcard 2U Rack Tower LCD display USB DB9 Serial MODEL NUMBER SU2200RTXLCD2U tt CANE Description Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters computer rooms and network closets Online double conversion Uninterruptible Power Supply UPS maintains perfectly regulated output power by continuously converting raw AC input to DC then re converting output back to AC Fully regulated sine wave AC output with 2 voltage regulation powers network equipment continuously even during severe brownouts and overvoltages all without depleting UPS battery reserves Maintains battery derived AC output during power failures with zero transfer time Extended runtime options available Interactive LCD interface reports UPS operating mode detailed UPS and site power data plus enables a variety of UPS setup and configuration options Highly efficient operation in optional economy mode saves BTU heat output and energy costs Network management interfaces support communications via USB RS 232 contact closure and optional SNMPWEBCARD network interface Built in DB9 port offers both enhanced RS 232 data and basic contact closure monitoring ability HID complian
6. TRMKITWM enables 2 post rack installation Optional 2 9USTAND enables tower placement e Single line TEL Network surge suppression e Electronic bypass maintains utility output during a variety of UPS fault conditions e Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement e Frequency regulation conversion mode offers generator compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz e USB RS 232 contact closure and optional SNMPWEBCARD accessory monitoring options e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Specifications OUTPUT ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts Output Capacity Details OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE b
7. V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Included Mounting Accessory Includes 4 post rackmount installation accessories Description Installation Form Factors Supported 2 Post rackmount 22OSTRMKITWM Tower 2 9USTAND Wallmount 22OSTRMKITWM with Optional Accessories Installation Form Factors Supported with Included Accessories Primary Form Factor Rackmount 4 7 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS Power Module Dimensions 3 5x17 5x19 hwd in UPS Power Module Dimensions 8 9x 44 4 x 48 3 hwd cm Rack Height U Spaces UPS Power Module Weight Ibs UPS Power Module Weight kg ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134
8. bility to save customers money while helping to protect the environment Applications e Distributed Server Rooms e Network Closets e Small Business Networks e Voice over IP VoIP Phone Systems Package Includes e SU2200RTXLCD2U UPS System e PowerAlert Software with USB Serial amp EPO cabling e 4 post rackmount installation kit e Instruction manual Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Two switched 3 outlet load banks support remote reboot or programmable load shedding options e Supports 2 output voltage regulation and zero transfer time in double conversion mode e Economy mode option offers enhanced efficiency reduced power consumption and lower BTU emissions e 12 minutes runtime at 50 load 900W and 4 minutes at 100 load 1800W with internal batteries e BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible and BP48V27 2US multi pack compatible external battery packs available some configurations require Tripp LiteExternal Battery Configuration Software e LCD interface reports operating mode plus 9 selectable screens of UPS data Load amp kW Load amp kVA Power factor Input volts amp Hz Output volts amp Hz Battery volts and charge Minutes runtime Capacity remaining Kw hr consumption e LCD interface also supports 16 screens of UPS configuration and setup options e 4 post installation hardware included Optional 2POS
9. e All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement 6 7 TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Specifications are subject to change without notice Photos may differ slightly from final products TIT
10. t USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface LED display reports UPS operating mode line power availability battery mode operation inverter operation ECO mode status and output power availability LED LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm with push button momentary alarm cancel and silent mode LCD configuration options Programmable self test Fault tolerant auto bypass mode Battery independent restart Field replaceable hot swappable internal batteries and external battery packs Features e Tripp Lite SU2200RTXLCD2U 2200VA 2 2kVA 1800W on line double conversion 2U rack tower UPS e Selectable 100 110 120 127V output 120V factory preset e NEMA 5 20P input 6 NEMA 5 15 20R and 1 L5 20R outlets 1 7 Highlights e 2200VA 2 2kVA 1800W on line double conversion 2U rack tower UPS e 100 110 120 127V 50 60Hz output High efficiency economy mode option e Interactive LCD with 9 selectable screens of UPS and site power data e Expandable runtime Hot swap batteries 19 in 48 3cm depth e USB RS232 amp EPO ports support for SNMP WEB card option e 2 independently switched load banks e NEMA 5 20P input 6 NEMA 5 15 20R amp 1 L5 20R outlets e This product is ENERGY STAR qualified for its a
11. tinuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Included Battery Pack Dimensions hwd in ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits UPS Shipping Dimensions hwd in 9 5 x 20 x 24 UPS Shipping Dimensions hwd 24 1 x 50 8 x61 cm i Shipping Weight Ibs Cooling Method Included Battery Pack Dimensions hwd cm ENVIRONMENTAL 683 AC Mode BTU Hr Full Load S T Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com AC Economy Mode BTU Hr Full 390 Load 100 Load COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial Contact closure
12. ypass limits Nominal Output Voltage s 100V 110V 115V 120V 127V Supported i Nominal Voltage Details 120V factory default nominal voltage Frequency Compatibility 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion ON LINE MODE Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz BATTERY MODE Output is regulated to 0 05Hz 2 7 Frequency Compatibility Details Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Output Voltage Regulation Line 2 Mode Output Voltage Regulation Ano Economy Line Mode PEAD Output Voltage Regulation Battery 3 Mode Output Receptacles 6 5 15 20R 1 L5 20R ON LINE MODE Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal FREQUENCY REGULATION CONVERSION MODE Maximum output ratings are reduced in frequency regulation conversion mode 127 120V 1260 watts 115V 1134 watts 110V 1071 watts 100V 1008 watts OVERLOAD CAPACITY
Download Pdf Manuals
Related Search
Related Contents
Equipment Wilo-Star Plantilla Twilight å° ã‚¨ãƒªã‚¢TRシリ.. Franke CRX 651 User Manual MANUALE FLY-TN NEW MultiComm™ ITIL KB Documentation Copyright © All rights reserved.
Failed to retrieve file