Home

Riello Sentinel Dual 5000

image

Contents

1. e Input protection through resettable thermal switch e Standard Back feed protection to prevent energy from being fed back to the network e Manual switching to bypass 4 Attach the rack supports www riello ups com Wrielloves Advanced communication details e Advanced multi platform communication for all operating SDL 8000 SDL 10000 Se network environments eBLGSOO THE supervision and shutdown SDL 3300 SDL 5000 SDL 8000 TM PowerShield software for Windows SDL 4000 ae SDL 6000 SDL 10000 TM operating systems 7 2008 Vista 2008 XP Linux Mac OS X Sun Solaris SERIAL PORT a N VMware ESX and other Unix operating A z COMMUNICATION SLOT systems e Plug and Play function SET en i A iF e USB Port O o PROTECTION 6 gt 0 o e RS232 serial port g a cas o do e Slot for installation of communications 5 a J R o OUTPUT SOCKET boards loo0co BATTERY O EXPANSION 2 YEAR WARRANTY k i CONNECTOR DAO INPUT CABLE Options Se i Bo e Battery cabinets for extended runtimes E eae Q with or without batteries lt 8 8 e Telescopic rails for rack cabinet mounting battery box MODELS BB SDL 108 A4 BB SDL 108 M1 BB SDL 192 A3 BB SDL 192 A6 BC SDL 108 B1 SDL 5000 6000 MODELS SDL SDL 3300 4000 SDL G500TM 8000 8000TM 10000 10000TM SDL 3300 4000 Tower Dimensions mm 455 630 455 y g
2. lt 7 aS ca ee ee E eee ae ee PF sees Wrielloves www riello ups com SDL 3300 SDL 4000 SDL 5000 SDL 6000 SDL 8000 SDL 10000 MODELS POWER 3300VA 2300W 4000VA 2400W S5000VA 3500W 6000VA 4200W 8s000VA 6400W 10000VA 8000W INPUT Nominal voltage Minimum voltage 220 230 240 Vac 164 Vac load 100 84 Vac load 50 Nominal frequency 90 or 60 Hz 5Hz Power factor gt 0 98 Current distortion lt BY PASS Voltage tolerance 180 264 Vac Selectable in Economy Mode and Smart Active Mode Frequency tolerance Selected frequency 5 selectable by user OUTPUT Nominal voltage 220 230 240 Vac selectable Voltage distortion lt 3 with linear load lt 6 with non linear load Frequency 90 or 60 Hz selectable Static variation 1 5 Dynamic variation lt 5 in 20 ms Waveform sinusoidal Crest factor 3 1 BATTERIES Charging time 4 6 hours OVERLOAD TIMES 100 lt Load lt 110 1 minute 110 lt Load lt 150 4 seconds Load gt 150 0 5 seconds OTHER FEATURES Net weight kg 38 40 62 64 94 95 Gross weight kg 42 5 44 5 70 12 102 103 455 x 175 x 520 tower 455 x 175 x 660 tower 2 X 455 x 175 x 660 tower Dimensions hwd mm Packaging dimensions 175 4U x19 x483 rack 175 4U x19 x660 rack 2 x 175 4U x19 x660 rack 540 x 620 x 280 720 x 530 x 270415 780 x 555 x 270415 hwd mm Line Interactive Smart
3. Active output on Protection devices Overcurrent short circuit overvoltage undervoltage thermal excessive low battery protection devices Communication USB RS232 slot for communications interface Input sockets 1 IEC 320 C20 Terminal board Output socket 2 IEC 320 C13 1 IEC 320 C20 Terminal board 2 IEC 320 C13 Regulations EN 62040 1 EMC EN 62040 2 Directive 73 23 93 68 2004 108 EC EN 62040 3 Ambient temperature 0 C 40 C Relative humidity lt 95 non condensing Colour Dark grey RAL 7016 Noise level lt 40 dBAa1m lt 45 dBAalm Standard equipment provided standard www riello ups com Two 10A cables One IEC 16A plug software serial cable keys to release mimic panel handles kit Two cable guides terminal board connections One IEC 16A plug software serial cable keys to release mimic panel handle kit Wrielloves SDL 6500 TM SDL 8000 TM SDL 10000 TM MODELS POWER INPUT 6500VA 5200W 8000VA 6400W 10000VA 8000W Nominal voltage 400 Vac Three phase N Minimum voltage F N 164 Vac load 100 84 Vac load 50 Nominal frequency 90 or 60 Hz 5Hz Power factor gt 0 95 BY PASS Voltage tolerance Frequency tolerance 180 264 Vac selectable in Economy Mode or Smart Active Mode selected frequency 5 selectable by user OUTPUT Nominal voltage 220 230 240 Vac selectable Voltage distortion lt 3 with
4. linear load lt 6 with non linear load Frequency 90 or 60 Hz selectable Static variation 1 5 Dynamic variation lt 5 in 20 ms Waveform sinusoidal Crest factor 3 1 BATTERIES Charging time 4 6 hours OVERLOAD TIMES 100 lt Load lt 110 1 minute 110 lt Load lt 150 4 seconds Load gt 150 0 5 seconds OTHER FEATURES Net weight kg 91 94 95 Gross weight kg 99 102 103 Dimensions hwd mm 2 X 660x175x455 2 x 4Ux19 x660 Packaging dimensions hwd mm 780 x 555 x 270 15 Smart Active Output up to 98 Protection devices Overcurrent short circuit overvoltage undervoltage thermal excessive low battery protection devices Communication USB RS232 slot for communications interface Input sockets Terminal board Output socket Terminal board 2 IEC 320 C13 Regulations EN 62040 1 EMC EN 62040 2 Directive 73 23 93 68 2004 108 EC EN 62040 3 Ambient temperature 0 C 40 C Relative humidity lt 95 non condensing Colour Dark grey RAL 7016 Noise level lt 45 dBAal1m Standard equipment provided standard Two cable guides terminal board connections One IEC 16A plug software serial cable keys to release mimic panel handle kit www riello ups com Wrielloves ITALIA LEGNAGO Headquarters Production and Sales Management Viale Europa 7 37045 Legnago VR Tel 39 0442 635811 Fax 39 0442 629098 www riello ups com riello riel
5. ESPANA Tel 34 955 040044 Fax 34 955 040041 www riello enerdata es enerdata riello enerdata es RIELLO TDL s l c Terra Alta 88 P I Can Carner 08211 Castellar Del Vall s Barcelona Tel 34 0 93 74 71 210 Fax 34 0 93 71 46 562 www riello tdl com comercial riello tdl com DEUTSCHLAND RIELLO UPS GmbH Siemensstr 12 21465 Reinbek bei Hamburg Tel 49 0 40 727 57 06 Fax 49 0 40 727 57 189 www riello ups de info riello ups de RIELLO ELETTRONICA www riello ups com riello riello ups com INDIA RIELLO PCI INDIA PVT LTD Prime Group Building 11 5B Pusa Road New Delhi 110 005 Phones 91 11 41 888 999 30 lines 41 888 888 25 6 2562 604 2576 2552 53 2581 3338 Fax 91 11 2575 5815 2582 1623 PEOPLE S REPUBLIC OF CHINA Riello UPS Asia Co Ltd 28F No 500 Fute Dong Er Road Waigaoqiao Free Trade Zone Pudong District 200131 Shanghai Tel 86 21 50464748 Fax 86 21 50464648 www riello ups com info riello ups cn Riello UPS Asia Beijing Office No 418 4F Block A Gaode Platza No 10 Huayuan Dong Road Haidian District Beijing Tel 86 10 82038861 8862 Fax 86 10 82038863 Riello UPS Asia Guangzhou Office Address Unit 1507 East Building Dongshan Square No 65 Xianlie Zhong Road Yuexiu District 510095 Guangzhou Tel 86 20 28848001 Fax 86 20 28848002 ASIA PACIFIC SINGAPORE REPRESENTATIVE OFFICE No 138 Robinson Road The corporate o
6. RIELLO ELETTRONICA Highlights e Simplified Installation e Operation selection e High quality output voltage e High battery reliability e Emergency Back up function e Battery optimisation e Energyshare e Reduced noise e On line VFI LOCAL AREA NETWORKS LAN SERVERS CENTRES 000 DATA CASH REGISTERS PLCS MEDICAL INDUSTRIAL ELECTRO EMERGENCY DEVICES DEVICES Lights Alarms Sentinel Dual WAriello vps 3 3 10 KVA single single phase and three single phase SENTINEL DUAL is the best solution for powering sensitive and vital mission Critical utilities and safety devices electro medical ensuring maximum power reliability The flexibility of installation and use digital display user removable batteries and the many communication options make SENTINEL DUAL a UPS suitable for many applications from information technology to security SENTINEL DUAL can be installed on the floor or in rack cabinets for networking applications The SENTINEL DUAL is available in 3 3 4 5 6 8 10 kVA models and uses double conversion On line technology VFI the load is powered continuously by the inverter which supplies sinusoidal voltage that is filtered and stabilised in terms of voltage form and frequency in addition the input and output filters significantly increase the load s immunity to network disturbances and lightning strikes Technology and performance selectable Econ
7. ffice 14 06 068906 SINGAPORE Tel 65 6323 4131 FAX 65 6323 4212 www riello ups com info riello ups s g In the interest of product improvement Riello UPS reserves the right to change specifications without notice FLVSDLGB101RU
8. lo ups com MILANO Production and Sales Office Via Somalia 20 20032 Cormano MI Tel 39 02 663271 Fax 39 02 66327351 www riello ups com riello riello ups com ROMA Sales Office Via Fosso della Magliana 34 G 00148 Roma Tel 39 06 65192125 Fax 39 06 65192247 www riello ups com rielloroma riello ups com UK RIELLO UPS Ltd Unit 50 Clywedog Road North Wrexham Industrial Estate Wrexham LL13 9XN Tel 44 0 1978 729 297 Fax 44 0 1978 729 290 www riello ups co uk riello riello ups co uk CONSTANT POWER SERVICES Ltd Unit 3 Trust Industrial Estate Wilbury Way Hitchin Herts SG4 OUZ Tel 44 0 1462 422 955 Fax 44 0 1462 422 754 www cps4ups co uk info cps4ups co uk FRANCE RIELLO ONDULEURS s a r l SIEGE SOCIAL 2 4 Rue du Bois Chaland ZAC du Bois Chaland 91090 Lisses Tel 33 0 1 60 875454 Fax 33 0 1 60 875450 www riello onduleurs com ventes riello onduleurs com SALES SUD 147 Avenue M M rieux Parc de Sacuny Park Avenir 1 69530 Brignais Tel 33 0 4 72 177108 Fax 33 0 4 78 351422 www riello onduleurs com contact riello onduleurs com ESPANA RIELLO ENERDATA s l C Labradores 13 Urb Prado del Espino 28660 Boadilla del Monte Madrid Tel 34 0 91 63 33 000 Fax 34 0 91 63 21 793 www riello enerdata es enerdata riello enerdata es RIELLO ENERDATA s l C Aviacion 18 Edificio Morena y Vallejo 1 1 planta pol Ind Calonge 41007 Sevilla
9. ms etc In case of a black out the inverter begins powering the load with a progressive start Soft start in order to prevent overloading Battery optimisation The wide input range and a high Hold Up Time value minimise battery interventions and increase efficiency and battery life for smaller power breaks energy is drawn from a group of appropriately sized capacitors EnergyShare 5 10kVA The presence of two configurable IEC output sockets allows for runtime optimisation programming the switch 3 Rotate the UPS 90 off of low priority loads alternatively emergency only loads normally not powered when the mains is present can be activated Reduced noise Thanks to the digital PWM control the speed of the fans is adjusted depending on the temperature of the two internal heatsyncs ensuring extended life and a reduction in noise to less than 45dB Other features e Output voltage can be selected using software 220 230 240V e Auto restart when mains power is restored programmable via software e Bypass on when the machine is switched off it automatically goes into bypass and battery charge mode e Minimum load switch oft e Low battery warning e Start up delay e Total microprocessor control e Automatic bypass without interruption e Use of IMS modules Insulated Metallic Substrates e Statuses measurements and alarms available on standard backlit display e UPS digital updating flash upgradable
10. omy Mode and Smart Active Mode functions Diagnostics standard digital display RS232 and USB interface with PowerShield software included and communication slot for connectivity accessories Simplified Installation e May be installed on the floor tower version or in rackmount cabinets rack version The mimic panel can be rotated using the key supplied e Low noise lt 40dBA can be installed in any environment thanks to its PWM digitally controlled ventilation dependent on the load applied and on the use of a high frequency switching inverter e Can be connected to an external maintenance bypass 5 6 8 10 kVA SDLs e Features guaranteed up to 40 C the components are designed for high temperatures and are thus subject to less stress at normal temperatures e Availability of two built in IEC output sockets with thermal protection 5 6 8 10 kVA SDLs e On the 5 6 8 10 kVA models it is possible to programme two 10A output sockets EnergyShare function to turn off when the mains power supply fails Operation selection The functions may be programmed using software or manually via the mimic panel e On line e ECO Mode to increase output up to 98 allows for selection of Line Interactive technology VI to power low oriority loads from the mains e Smart Active the UPS automatically decides upon the operating mode VI or VFI based on the quality of the network e Back up the UPS can be selected to func
11. tion only when mains power fails emergency mode only e Frequency converter 50 or 60 Hz High quality output voltage e Even with non linear loads loads with a rest factor of up to 3 1 e High short circuit current on Bypass e High overload capacity 150 by inverter even with mains failure 1 Release the mimic panel by applying pressure to the catch 2 Rotate the mimic panel counter clockwise and then secure it back in place e Filtered stabilised and reliable voltage double conversion On line technology VFI compliant with IEC 62040 3 with filters for the suppression of atmospheric disturbances e Power factor correction UPS input power factor close to 1 and sinewave current absorption High battery reliability e Automatic and manual battery test e Reduced ripple component detrimental to the batteries thanks to the LRCD system Low Ripple Current Discharge e Batteries are user replaceable without interruption to the power to the load Hot Swap e Unlimited extendible runtime via dedicated modular design Battery Boxes e The batteries are not activated during mains failure of lt 40 ms high hold up time or when there are variations in input voltage from 84V to 276V Emergency Back up function This configuration ensures the operation of those devices that require continuous and lasting power during mains failure such as emergency lighting systems fire detection extinction systems alar

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation et d`entretien  取扱説明書 (719 KB) - ランズバーグ・インダストリー  Hitachi 873440 Network Card User Manual  Manual de instrucciones Manual de instrucciones  コントローラ取扱説明書(TC83 Ⅱ)    

Copyright © All rights reserved.
Failed to retrieve file