Home

AMX CP-3017-NA

image

Contents

1. 2012 AMX All rights reserved DATA SHEET 17 Button ControlPad with Navigation US UK and Europe CP 3017 NA BA FG1302 17 2 A Aluminum CP 3017 NA BL FG1302 17 2 B Black CP 3017 NA WH FG1302 17 2 W White oo a id Ed aaa gt gt re Overview The Novara CP 3017 NA ControlPad with built in Ethernet port combines a controller with an easy to use 17 button keypad navigation pad and rotary volume control It mounts into a standard 2 gang US UK or EU back box or directly onto a podium using AMX s Podium Mounting Kit which is designed for simply beautiful integration of a ControlPad at the presenter s fingertips Setting up the Novara 3000 Series ControlPads is simple using Novara Device Configuration Software DCS and requires no programming The Novara ControlPads built in IR RS 232 relay and I O ports can be configured to control volume input selection and power for a wide range of A V devices including projectors DVD players and switchers Easily connect to AMX s Resource Management Suite which enables web based remote diagnostics and management through the built in Ethernet Port The Novara 3000 Series ControlPads are available in Black White and Aluminum finishes Common Applications Use as a standalone user interface controller for simple conference rooms classrooms or combine with an Enova AVX 400 for more complex rooms with switching as well as amplification requirements Features e
2. All in one Keypad Controller Unique product is a standalone user interface combined with an onboard controller e RMS Compatible Remotely monitor manage and control every room on the network e Built in Ethernet Port Allows the Novara ControlPad to communicate with RMS e Rotary Volume Knob With LED feedback Easily adjust the volume up down e Network Configurable Configure update an entire campus facility simultaneously e Device Configuration Software DCS No programming required for system setup e Navigation Pad Easily navigate through on screen menu s e Multiple Mounting Options Can be mounted into a standard box or directly onto a podium using AMX s AC 3017 Podium Mount Kit Control Features e Display Monitoring Use the ControlPad with RMS to monitor power status input status lamp hours and filter hours e Web based Control Remotely login to ControlPads and execute button presses e Event Scheduling Schedule equipment to turn on or off at a specific time e Inactivity Timer Turn off equipment after lack of activity timeouts to save energy e Toggle Mode Different functions executed based on how many times a button is pressed e Bank Mode Assign button function based on selected source e Control Ports IR serial relay and I O ports available for controlling room equipment e Volume Control With Feedback LEDs indicate current audio settings 8 17 button User Interface F
3. SA Pre printed labels 40 0087 Recommended Accessories CC NIRC IR Emitter Cable FG10 000 11 PS PoE EXO 9 PoE Extractor for Novara 3000 Series Control Pads FG423 85 CP RCO1 Infared Remote Control For Novara 3000 Series ControlPads AC 3017 Podium Mounting Kit for the Novara CP 3017 NA ControlPad FG1302 17A KT 17W KT 17B KT Temperature Operating 32 to 104 F 0 to 40 C Humidity Relative 5 to 85 non condensing Temperature Storage 14 to 140 F 10 to 60 C Button Layout 17 red green and blue backlit buttons with programmable feedback 1 Pressable volume knob 1 Volume indicator 1 5 button navigational pad white backlighting only 1 2 pin Phoenix connector accepting 12 VDC power Serial 3 3 pin Phoenix connectors for RS 232 connections Input voltage VIH gt 2 7 VDC VIL lt 2 7 VDC Output voltage VOH gt 5 0 VDC 35 mA maximum VOL lt 5 0 VDC 35 mA maximum 2 2 pin Phoenix connector for IR emitters Supports generating carriers up to 1 142 MHz Output only port Output voltage VOH 3 3 VDC 0 3 VDC 13 mA maximum VOL 0 VDC 0 3 VDC 13 mA maximum 1 4 pin Phoenix connector for I O connections Supports sensing contact closure Input voltage HIGH no contact closure VIH gt 2 5 VDC LOW contact closure VIL lt 0 8 VDC Output voltage VOH 3 3 VDC 0 3 VDC internal 25k Ohm pull up resistor VOL O VDC 0 3 VDC 200 mA maximum sink cur
4. 153
5. delivering a simple way to manage monitor and schedule rooms and equipment in real time Proactively Maintain Equipment e Maintain real time monitoring and problem notifications e Check equipment system status for equipment errors e Provides immediate notification when equipment is removed from the network to help reduce theft Help Desk Support and Monitoring e Complete diagnostics and remote analysis e Monitor display devices for power status input status lamp hours and filter hours e Remotely execute button presses to control equipment connected to the ControlPads Schedule Rooms and Pre Configure Equipment e Check a room s daily weekly or monthly availability e Reserve a room and schedule room equipment to turn on before meetings or classes e Schedule room equipment to turn off at the end of the day to save energy Specifications GENERAL Dimensions HWD Including knob 411 16 x 6 x 1 3 4 11 9 cm x 15 2 cm x 4 5 cm Mount onto standard 2 gang US UK or EU back boxes Mount directly onto a podium using AC 3008 Podium Mounting Kit for the Novara CP 3017 ControlPad FG1302 17A KT 17W KT 17B KT weight 14 02 392 8 12 VDC Using a non PoE power supply operates on voltages ranging from 9 V to 16 V continuously Certifications FCC Class B CE UL CB Scheme Colors Available Aluminum FG1302 17 2 A Black FG1302 17 2 B White FG1302 17 2 W Included Accessories Power Supply 90 240 VACIN 12 VOUT 500 MA 24 5791
6. eatures e Backlit Buttons Can be set to change colors flash or turn off when pressed e LED Volume Bar Graph Adjust the brightness level of the LEDs on the volume bar graph e Security Lockout Locks out the device to prevent unauthorized use e Standard Enclosures Standard back box mounting options for US UK and EU Discovering ControlPads on the Network e ZeroConfig Automatically detect devices on the network simplified commissioning e Manually Search Enter an IP address or Hostname and DCS will search across subnets Configuring ControlPads e Device Configuration Software DCS No programming required for system setup e Network Configurable Configure update an entire campus facility simultaneously e Execute Multiple Functions at Once Scripts can be written to trigger multiple functions through a single button press e Works with AMX IR Files Leverage thousands of pre existing AMX IR files on AMX com e DNS Servers Now supports multiple servers e CP RMS Software Proxy software that runs on RMS server required for RMS communication with ControlPads Novara 3000 Series and Resource Management Suite RMS K 12 schools universities and businesses can easily integrate independent building systems into a single unified control platform that centralizes management improves response time and streamlines processes using RMS The Novara 3000 series built in Ethernet port connects each room to the RMS network
7. rent Relay 1 4 pin Phoenix connector for relay connections capable of switching 24 VDC 1A maximum or 28 VAC 1 A maximum ON 0 R45 connector for LAN connectivity 1 pinhole pushbutton for factory reset Supported Baud Rates Up to 115200 O LAN el DNAN 4 5 cm YY CP 3017 NA CP 3017 NA Bottom View Isometric View 6 15 2 cm SARB at t 4 11 16 11 9 cm ono aa Sax Bax gt 0 gt s a 5 Lyd HE CP 3017 NA CP 3017 NA CP 3017 NA Front View Right View Back View About AMX AMX hardware and software solutions simplify the implementation maintenance and use of technology to create effective environments With the increasing number of technologies and operating platforms at work and home AMX solves the complexity of managing this technology with reliable consistent and scalable systems Our award winning products span control and automation system wide switching and audio video signal distribution digital signage and technology management They are implemented worldwide in conference rooms homes classrooms network operation command centers hotels entertainment venues broadcast facilities and more 2012 AMX All rights reserved Specifications subject to change Revised 18 Apr 12 AMX com 800 222 0193 469 624 8000 1 469 624 7400 fax 469 624 7

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Usuario  Kompernass KH 2331 Instruction Manual  Mode d`emploi  Type 0400 - Burkert Fluid Control Systems  aceite italika  P06EPAr33  

Copyright © All rights reserved.
Failed to retrieve file