1. 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 151 9 207 USB DB9 Serial EPO emergency power off Slot for SNMP Web interface Supports detailed monitoring of UPS and site power conditions Included USB and DB9 cabling included Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time Low voltage transfer to battery power setpoint High voltage transfer to battery power setpoint SPECIAL FEATURES Grounding lug Cold Start startup in battery mode during a power failure High availability UPS features Green amp high efficiency features CERTIFICATIONS UPS Certifications WARRANTY Product Warranty Period U S Canada amp Puerto Rico Connected Equipment Insurance U S Canada amp Puerto Rico 2 4 milliseconds 83 147 Back panel grounding lug Cold start operation supported Hot swappable batteries Individually controllable load banks Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category B EMI ROHS Restriction of Hazardous Substances TAA Compliant 2 year limited warranty 250 000 Ultimate Lifetime Insurance Related Items Optional Products Product Type Extended Warranties Extended Warranties Power Cables Power Cables Power Cables Po
2. 15R outlets PDUMV15 OU 16 5 15R outlets PDUMH15ATNET 1U 8 5 15R outlets PDUMV15NET 0U 16 5 15R outlets Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS models only Sine wave Pure Sine wave 6 8A 120V AC 5 15P 15A 10 15A 120V 7 min 700w 17 min 350w 24 Less than 4 hours from 10 to 90 RBC92 2U Front panel battery access door Hot swappable user replaceable batteries Automatic voltage regulation AVR maintains line power operation with an input voltage range of 83 to 147 Input voltages between 128 and 147 are reduced by 12 Input voltages between 83 and 107 are boosted by 14 LEDS ALARMS amp SWITCHES LED Indicators Alarms 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Switches Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status 2 Switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppression joule rating UPS AC suppression response time EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Installation form factors supported with optional accessories Pr
3. Tripp Lite rN 1111 West 35th Street TRIPP LITE Chicago IL 60609 USA r Telephone 773 869 1234 E mail saleshelp tripplite com Model SM1000RM2UTAA TAA Compliant SmartPro Rack Tower UPS Intelligent line interactive network power management system Highlights e Compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases e 1000VA 1kVA line interactive 2U rack tower UPS e Maintains sine wave 120V nominal output over an input range of 83 to 147V e Network communications supported via USB port serial port SNMP Web card slot and EPO interface e Current monitoring and switched PDU control via 2 two outlet load banks e Input NEMA 5 15P 120V 15A Output 6 NEMA 5 15R 120V e 2 year product warranty 250 000 Ultimate Lifetime Insurance USA Puerto Rico amp Canada only Description Tripp Lite s SM1000RM2UTAA is compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases This intelligent line interactive sine wave rack tower uninterruptible power supply prevents data loss downtime and equipment damage due to power outages voltage fluctuations and transient surges Requires only two rack spaces 2U in a standard rack enclosure Large internal batteries offer 17 minutes half load runtime and 7 minutes at full load Maintains regulated 120V nominal output without using battery power during brownouts and overvoltages from 83 to 147V 1000VA 700 watt power handling capab
4. cifications OUTPUT Output Volt Amp Capacity VA Output kVA capacity kVA Output Watt Capacity watts Output power factor Nominal Output Voltage s Supported Frequency compatibility Output voltage regulation line mode Output voltage regulation Battery mode Built in UPS output receptacles Built in controllable switched load banks Basic PDU options 1000 700 0 7 120V 60 Hz 21 8 5 6 5 15R outlet s Two switchable two outlet 5 15R load banks PDU1215 1U 13 5 15R outlets PDUNV 1U 2 C19 12 C13 outlets PDU1415 OU 14 5 15R outlets PDUV15 OU 12 5 15R outlets Metered PDU options Switched PDU options External PDU redundancy options Output AC waveform AC mode Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type Input circuit breaker UPS Input cord length ft UPS Input cord length m Recommended Electrical Service BATTERY Full load runtime minutes Half load runtime minutes DC system voltage VDC Battery recharge rate included batteries Replacement battery cartridge internal UPS battery replacement Battery Access Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction PDUMH15 1U 13 5 15R outlets PDUMH15AT 1U 8 5
5. e SM1000RM2UTAA TAA Compliant UPS System e Mounting hardware for 4 post rackmount installation e Cabling for USB amp DB9 monitoring and EPO switching e PowerAlert unattended shutdown and UPS Power monitoring software e Warranty information and instruction manual Features e Compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases e SM1000RM2UTAA line interactive UPS offers battery derived sine wave AC output during power outages voltage regulation during brownouts and overvoltages plus network grade AC surge suppression e 1000VA 700 watt power handling capability with full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic devices e Supports 2U rackmount installation in 4 post rack enclosures with included mounting accessories 2 post rackmount mountable with optional 2POSTRMKITWM accessory upright tower installation supported with optional 2 9USTAND accessory e Large internal batteries offer runtimes of 17 minutes at half load 500VA 350 watts and 7 minutes at full load 1000VA 700 watts e Maintains regulated 120V nominal output during brownouts and overvoltages from 83 to 147V e Includes 6 UPS supported outlets arranged in 2 individually controllable load banks 2 outlets per bank that can be powered off and back on again via software interface e PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging
6. echnical specifications can be found online at www tripplite com en products model cfm txtModellD 4386 Copyright 2011 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
7. email notification event logging and running user defined script commands e Offers simultaneous monitoring by up to 3 directly connected devices through included USB DB9 and SNMP interfaces requires optional SNMPWEBCARD or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software e Communications ports support messaging of UPS and line power status including on battery low battery power restored AC line voltage DC battery voltage and remaining battery capacity e Supports timed inverter shutoff after unattended shutdown activate self test and UPS output power control for delayed or immediate reboot of connected devices e Supports Tripp Lite s WatchDog software application to restore unresponsive programs by systematically restarting applications operating systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again requires optional WATCHDOGSW e Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter e Emergency Power Off EPO interface with cable e Multi function audible alarms and set of 5 front panel LEDs e Network grade AC surge suppression e Attractive all black color scheme e UPS battery set ships fully assembled and ready for installation no time consuming connection of internal batteries by user is necessary e Two year warranty with 250 000 connected equipment insurance USA amp Canada only Spe
8. ility and full time sine wave output supports networking telecom and other sensitive electronic applications Includes a total of 6 outlets arranged in 2 load banks that are individually controllable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment Supports simultaneous remote monitoring of UPS and site power conditions via built in network accessory card slot USB and DB9 serial monitoring ports Optional SNMPWEBCARD accessory enables remote monitoring of UPS as a managed device via network management console applications Communications ports support messaging of detailed UPS operating parameters and line power status Includes PowerAlert UPS monitoring and unattended shutdown software with management support for an unlimited number of network UPS systems Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter Emergency Power Off EPO interface offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise Attractive all black color scheme Two year warranty with 250 000 connected equipment insurance USA amp Canada only Package Includes
9. imary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system total rack space height rack spaces Secondary form factor Installed whole system dimensions in secondary form factor height x width x depth inches UPS dimensions in secondary form factor height x width x depth cm UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg 480 Instantaneous Yes 4 post 19 inch rackmount mounting rail kit included 2 post rackmount 2POSTRMKITWM Wallmount 2POSTRMKITWM Tower 2 9USTAND Rackmount 3 5 x 17 5 x 13 5 8 9 x 44 4 x 34 3 2U Tower requires 2 9USTAND 17 5 x 3 5 x 13 5 44 4 x 8 9 x 34 3 35 15 9 9 x 24 x 20 2 22 9 x 61 x 51 4 41 5 18 8 UPS housing material Cooling method ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load Battery mode BTU hr full load COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable WatchDog compatibility Steel Fan 32 to 104 degrees Fahrenheit
10. t Safe reliable power distribution with digital current meter Metered PDU with ATS Power Distribution Unit with dual input Auto Transfer Switching Switched Metered PDU with ATS Power Distribution Unit with dual input Auto Transfer Switching individual outlet control and remote network interface Monitored PDU Power Distribution Unit supports real time remote monitoring of load level voltage and frequency with options for remote environmental and security monitoring Monitored PDU Power Distribution Unit supports real time remote monitoring of load level voltage and frequency with options for remote environmental and security monitoring Switched Metered PDU with Remote Monitoring OU Vertical Rackmount Power Distribution Unit for Networks with Individually Switchable Outlets Current Metering Remote Monitoring and Control Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 2U UPS Replacement Battery Cartridge for select Tripp Lite SmartPro UPS Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU For remote monitoring and control via SNMP Web or Telnet WatchDog Service Monitoring Reboot Software Enables Tower Placement of Rackmount UPS Systems Qty More information including related products owner s manuals and additional t
11. wer Cables Power Cables Power Cables Power Cables Power Distribution Power Distribution Power Distribution Power Distribution Power Distribution Power Distribution Power Distribution Power Distribution Rackmount Wallmount Kits Replacement Batteries SNMP Accessories SNMP Accessories Software Tower Stands Related Model WEXT3 500 1500 WEXT5 500 1500 P007 002 P007 006 P007 010 P010 012 P022 001 P023 001 P034 010 PDU1215 PDUMH15 PDUMH15AT PDUMH15ATNET PDUMNH15 PDUMNV15 PDUMV15NET PDUNV 2POSTRMKITWM RBC92 2U ENVIROSENSE SNMPWEBCARD WATCHDOGSW 2 9USTAND Description 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less 2 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 6 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 10 ft Heavy Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 12 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 ft 18AWG Power Extension cord NEMA 5 15R to NEMA 5 15P 1 ft 14AWG Power Adapter cord NEMA L5 15R to NEMA 5 15P 10 ft 14AWG Heavy Duty Power cord IEC 320 C19 to NEMA 5 15P Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Metered PDU Power Distribution Uni