Home

Kathrein ZAS 04

image

Contents

1. Mounting accessories ZAS 02 ZAS 03 ZAS 04 ZAS 05 ZAS 06 218612 218613 218687 20410007 20410008 Hot dip galvanised Mast calculation max bending moment see page 50 of Type ZAS 02 ZAS 03 ZAS 04 ZAS 05 ZAS 06 Order no 218612 218613 218687 20410007 20410008 mm 60 60 60 48 48 Dimensions L m 0 56 2 0 3 0 2 0 3 0 Wall thickness mm 2 3 2 3 Grade steel St 37 2 St 37 2 St 52 3 St 37 2 St 52 3 Allow bending moment at 800 N m Nm 1 565 2 350 1 517 2 710 1 021 Allow bending moment at 1 100 N m Nm 1 533 2 300 1 467 2 684 966 CAS 60 CAS 60 CAS 60 Suitable for parabolic antennas CAS 75 GAS T CRo T3 CASO CASDI CAS 90 CAS 90 CAS 90 CAS 75 CAS 75 CAS 120 CAS 120 Packing unit weight pc kg 1 5 1 75 1 25 9 0 1 25 12 0 1 25 5 5 1 25 8 5 1 The wind load of the masts has already been considered The max allowable bending moment on the fixing point applies to max usable length Acc to EN 60728 11 part 1 the mast clamping length must be 1 6 of the mast length 2 Applies to 1 650 Nm on the clamping point If this value is exceeded static proof is required acc to EN 60728 11 52

Download Pdf Manuals

image

Related Search

Related Contents

` ` 曲 SUPER SMYAN vEG打A MANUAL  heuse 6 9az Dryer  THERMOLIFT  INSECICIDE 14  MODE D`EMPLOI  FICHE SIGNALÉTIQUE ALIAS® 240 INSECTICIDE  GECOL Pronto  Millennium 3 - DAVI Y CIA, S.L.  Tribunal Regional Eleitoral de Santa Catarina  IBM Opteron 270  

Copyright © All rights reserved.
Failed to retrieve file