Tripp Lite SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

image

Contents

1. Overvoltaga Conection wye reducing output within 2 of nominal Maintains continuous operation without using battery power during brownout undervoltage conditions to 96 166 3 Phase 4 Wire wye USER INTERFACE ALERTS amp CONTROLS SELECTABLE LCD DISPLAY indicates a wide range of UPS operational and fault warning conditions including Front Panel LCD Display operational mode alarm shutdown conditions input output voltage frequency battery voltage load percentage and more see manual Undervoltage Correction 3 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com ON button turns UPS s inverter ON OFF button turns UPS s inverter OFF Select Button browses through items displayed on LCD screen Enter button selects items displayed on LCD screen Select and Enter buttons used Switches simultaneously mute UPS alarms Battery Start Switch cold starts the inverter Emergency Power Off button turns UPS output OFF and disables Bypass output Manual Bypass switch bypasses the UPS s inverter during maintenance Alarm Cancel Operation Power fail alarm can be silenced using alarm cancel switch Audible Alarm Alarms warn against a variety of operational conditions low battery overload shutdown bypass and more 7 LED DISPLAY AC input bypass input AC DC charger DC AC inverter AC output bypass operation and LED Indicators battery operation SURGE NOISE SUPPRESSION AC S
2. 0 000VA 16 000 watt UPS continually converts incoming AC power into filtered DC power and then resynthesizes it back into AC power with a pure sine wave Perfectly regulated continuous sine wave output with s Maranyinfomaion zero transfer time offers compatibility with all equipment types IGBT inverter technology produces output power gne uetonmanual with lt 3 THD total harmonic distortion allowing connected equipment to perform at its peak A 3 1 crest factor safely supports a variety of equipment even those with wildly fluctuating power demands Extremely efficient operation saves money by lowering electricity consumption Hardwire input and output connections support a variety of permanent or PDU style power connections SU20K3 3 features 120 208V AC 3 phase 4 wire plus ground wye input and output It also features a wide input voltage correction range 96 144 166 250V AC Frequency is 50 or 60 Hz auto selectable SU20K3 3 includes internal power and battery components in a single small footprint tower module Battery support can be extended with additional internal battery packs A manual bypass switch as well as an automatic bypass function ensure 100 availability of connected equipment by safely passing through AC power when the UPS requires maintenance Three built in communication ports RS 232 contact closure and AS 400 work with included PowerAlert Software to simultaneously provide shutdown commands and reporting on multiple server
3. During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI WARRANTY Product Warranty Period U S amp 1 year limited warranty Canada Product Warranty Period 2 year limited warranty International Product Warranty Period Mexico 1 year limited warranty S Warranty Period Puerto 1 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 5 5
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 3 Phase In Out 120 208V 20kVA 16kW Highlan On Line Double Conversion UPS Extended Run See ge SNMP Webcard Tower DB9 Serial Hardwired A tee MODEL NUMBER SU20K3 3 and battery components combined into a single small footprint module e Simplifies runtime scalability convenient front panel battery access for expandable runtime with additional internal battery packs e 3 phase hardwire input and output 120 208VAC Wide input voltage correction range 96 144V AC 166 250V AC e IGBT technology and zero transfer time on line double conversion operation Description e 3 communication ports SNMP card slot and EPO jack Tripp Lite s SU20K3 3 20kVA SmartOnline 3 Phase Intelligent True On Line UPS System has been redesigned to save valuable space and simplify runtime scalability Power and battery components are combined into a Package Includes single small footprint module the smallest in its class A robust internal battery runtime capability can be easily e SU20K3 3 UPS System power extended by installing additional optional internal battery packs through the convenient front panel access door and battery components in one module The SU20K3 3 provides mission critical equipment with the highest level of power protection available Large F e PowerAlert Software and cabling capacity 2
5. e Features a wide input voltage correction range 96 144 166 250V AC e Included internal batteries provide 13 minutes runtime at half load 8 000 watts and 5 minutes runtime at full load 16 000 watts e 3 1 crest factor safely supports a variety of equipment even those with wildly fluctuating power demands e Extend runtime by installing optional internal battery packs model SURBC2030 through the front panel access door SU20K3 3 includes 2 internal battery packs and accepts 2 additional internal battery packs A standalone battery module compartment with a 4 battery pack capacity and daisy chain capability model SUBF2030 is available to further extend runtime e 3 communication ports RS 232 contact closure and AS 400 e Slot for optional SNMP card model SNMPWEBCARD e Manual bypass switch as well as an automatic bypass function ensures 100 availability of connected equipment by safely passing through AC power when the UPS system requires maintenance e Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval e Emergency Power Off button turns UPS output OFF and disables Bypass output e PowerAlert Universal UPS Power Management Software and 6 ft communication cable included e Start up service program is recommended to enhance the reliability of the installation e Built in Emergency Power Off EPO interface supports remote emergency shutdown
6. in large facilities e Combination LED LCD display Specifications General Info OUTPUT a Nominal Output Voltage s 120 208V 3 Phase Wye Supported i Frequency Compatibility 50 60 Hz Output Voltage Regulation Line 2 Mode 2 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Mode INPUT BATTERY Full Load Runtime min 5 min 16kw Half Load Runtime min 13 min 8kw Expandable Battery Runtime Supports extended runtime with 2 internal and multiple optional external battery packs BP240V99 SUBF2030 holds 4 SURBC2030 SURBC2030 BP240V350 BP240V400 BP240V400C BP240V500 BP240V500C External Battery Pack Compatibility Includes a battery housing with space for 2 internal SURBC2030 battery packs for extended runtime Additional Expandable Runtime Description runtime capacity is available by adding SUBF2030 and additional SURBC2030 batteries see runtime chart for specific recommendations Battery Recharge Rate Included 2 4 hours from 10 to 90 Batteries Internal UPS Replacement Battery SURBC2030 Cartridge Battery Access Front panel internal battery access door Battery Replacement Description Hot swappable replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Maintains continuous operation without using battery power during overvoltages to 144 250 3 Phase 4 Wire
7. s without the need for costly accessories An accessory slot accepts an optional internal SNMP card model SNMPWEBCARD for remote shutdowns reboots and more A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval An Emergency Power Off button turns UPS output OFF and disables Bypass output Built in Emergency Power Off EPO interface supports remote emergency shutdown in large facilities Front panel combination LCD LED display alerts users to a variety of UPS operational modes and conditions A start up service program is recommended to enhance the reliability of the installation Features 1 5 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Saves valuable space power and battery components combined into a single small footprint module e Simplifies runtime scalability convenient front panel battery access for expandable runtime with additional internal battery packs e True on line double conversion UPS with IGBT technology provides pure sine wave AC output at all times e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e 20 000VA 16 000 watt power capacity with 3 phase hardwire 120 208V AC input output connections
8. uppression Joule Rating 2032 PHYSICAL Installation Form Factors Supported Tower with Included Accessories UPS Power Module Dimensions 35 9 x 19 5 x 36 8 hwd in UPS Power Module Dimensions 91 2 x 49 5 x 93 6 hwd cm i Installed Whole System Maximum Rack Depth cm UPS Power Module Weight Ibs 519 2 UPS Power Module Weight kg 233 6 UPS Shipping Dimensions hwd in 44 x 28 x 44 4 UPS Shipping Dimensions hwd 111 5x71 1x 113 cm i ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 5 to 95 non condensing AC Mode BTU Hr Full Load 6068 4 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com COMMUNICATIONS C LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Low Voltage Transfer to Battery Maintains continuous operation during undervoltages as low as 96 166V AC 3 Phase 4 Wire wye Below this Power Setpoint point output is maintained utilizing battery reserves High Voltage Transfer to Battery Maintains continuous operation during overvoltages as high as 144 250V AC 3 Phase 4 Wire wye Above this Power Setpoint point output is maintained utilizing battery reserves SPECIAL FEATURES Cold Start Startup in Battery Mode 3