Home
Tripp Lite SmartOnline 3-Phase In/Out 120/208V 30kVA 24kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwire
Contents
1. Product Warranty Period 2 year limited warranty International Product Warranty Period Mexico 1 year limited warranty AS Warranty Period Puerto 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 5 5
2. 000 watts and 5 minutes runtime at full load 24 000 watts e 3 1 crest factor safely supports a variety of equipment even those with wildly fluctuating power demands e Extend runtime by installing an optional internal battery pack model SURBC2030 through the front panel access door SU30K3 3 includes 3 internal battery packs and accepts 1 additional internal battery pack A standalone battery module compartment with a 4 battery pack capacity and daisy chain capability model SUBF2030 is available to further extend runtime e 3 communication ports RS 232 contact closure and AS 400 e Slot for optional SNMP card model SNMPWEBCARD e Manual bypass switch as well as an automatic bypass function ensures 100 availability of connected equipment by safely passing through AC power when the UPS system requires maintenance e Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval e Emergency Power Off button turns UPS output OFF and disables Bypass output e PowerAlert Universal UPS Power Management Software and 6 ft communication cable included e Start up service program is recommended to enhance the reliability of the installation e Built in Emergency Power Off EPO interface supports remote emergency shutdown in large facilities e Combination LED LCD display Specifications General Info OUTPUT a Nominal Output Voltage s 120 208V 3 Phase W
3. PS Power Module Weight kg 300 5 UPS Shipping Dimensions hwd in 43 x 28 x 44 5 cm ENVIRONMENTAL COMMUNICATIONS Communications Interface DB9 Serial Contact closure Slot for SNMP Web interface Network Monitoring Port Description RS232 contact closure and AS400 monitoring ports are supported by 3 separate DB9 ports PowerAlert Software Included Communications Cable DB9 cabling included 4 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Low Voltage Transfer to Battery Maintains continuous operation during undervoltages as low as 96 166V AC 3 Phase 4 Wire wye Below this Power Setpoint point output is maintained utilizing battery reserves High Voltage Transfer to Battery Maintains continuous operation during overvoltages as high as 144 250V AC 3 Phase 4 Wire wye Above this Power Setpoint point output is maintained utilizing battery reserves SPECIAL FEATURES Cold Start Startup in Battery Mode During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI WARRANTY Product Warranty Period U S amp 1 year limited warranty Canada
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 3 Phase In Out 120 208V 30kVA 24kW Highlights On Line Double Conversion UPS Extended Run E a a age SNMP Webcard Tower DB9 Serial Hardwire EE e Saves valuable space and MODEL NUMBER SU30K3 3 simplifies runtime scalability e 3 phase hardwire input and output 120 208VAC Wide input voltage correction range 96 144V AC 166 250V AC e IGBT technology and zero transfer time on line double conversion operation e 3 communication ports SNMP card slot and EPO jack Package Includes e SU30K3 3 UPS System power and battery components in one module neue e PowerAlert Software and cabling Description Tripp Lite s SU30K3 3 30kVA SmartOnline 3 Phase Intelligent True On Line UPS System has been redesigned to save valuable space and simplify runtime scalability Power and battery components are combined into a e Warranty information e Instruction manual single small footprint module the smallest in its class A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door The SU30K3 3 provides mission critical equipment with the highest level of power protection available Large capacity 30 000VA 24 000 watt UPS continually converts incoming AC power into filtered DC power and then resynthesi
5. eboots and more A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval An Emergency Power Off button turns UPS output OFF and disables Bypass output Built in Emergency Power Off EPO interface supports remote emergency shutdown in large facilities Front panel combination LCD LED display alerts users to a variety of UPS operational modes and conditions A start up service program is recommended to enhance the reliability of the installation Features e Saves valuable space power and battery components combined into a single small footprint module e Simplifies runtime scalability convenient front panel battery access for expandable runtime with additional internal battery packs e True on line double conversion UPS with IGBT technology provides pure sine wave AC output at all times 1 5 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e 30 000VA 24 000 watt power capacity with 3 phase hardwire 120 208V AC input output connections e Features a wide input voltage correction range 96 144 166 250V AC e Included internal batteries provide 13 minutes runtime at half load 12
6. rection Maintains continuous operation without using battery power during brownout undervoltage conditions to 96 166 Undervoltage Correction 3 Phase 4 Wire wye USER INTERFACE ALERTS amp CONTROLS SELECTABLE LCD DISPLAY indicates a wide range of UPS operational and fault warning conditions including Front Panel LCD Display operational mode alarm shutdown conditions input output voltage frequency battery voltage load percentage and more see manual ON button turns UPS s inverter ON OFF button turns UPS s inverter OFF Select Button browses through items Switches displayed on LCD screen Enter button selects items displayed on LCD screen Select and Enter buttons used simultaneously mute UPS alar Alarm Cancel Operation Power fail alarm can be silenced using alarm cancel switch 3 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Audible Alarm Alarms warn against a variety of operational conditions low battery overload shutdown bypass and more 7 LED DISPLAY AC input bypass input AC DC charger DC AC inverter AC output bypass operation and LED Indicators battery operation SURGE NOISE SUPPRESSION AC Suppression Joule Rating 2032 PHYSICAL Installation Form Factors Supported Tower with Included Accessories UPS Power Module Dimensions 35 9 x 19 5 x 37 9 hwd in f UPS Power Module Dimensions 91 2 x 49 5 x 96 3 hwd cm i U
7. ye Supported Frequency Compatibility 50 60 Hz Output Voltage Regulation Line 2 Mode Output Voltage Regulation Battery 2 Mode Output AC Waveform AC Mode Sine wave 2 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com INPUT Input Phase 3 Phase BATTERY Full Load Runtime min 5 min 24kw Half Load Runtime min 13 min 12kw Expandable Battery Runtime Supports extended runtime with optional external battery packs BP240V99 SUBF2030 holds 4 SURBC2030 SURBC2030 BP240V350 BP240V400 BP240V400C BP240V500 BP240V500C External Battery Pack Compatibility Includes a battery housing with space for 1 optional SURBC2030 battery pack for extended runtime Additional Expandable Runtime Description runtime capacity is available by adding SUBF2030 and additional SURBC2030 batteries see runtime chart for specific recommendations Battery Recharge Rate Included 2 4 hours from 10 to 90 Batteries Internal UPS Replacement Battery SURBC2030 Cartridge Battery Access Front panel internal battery access door Battery Replacement Description Hot swappable replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Maintains continuous operation without using battery power during overvoltages to 144 250 3 Phase 4 Wire wye reducing output within 2 of nominal Overvoltage Cor
8. zes it back into AC power with a pure sine wave Perfectly regulated continuous sine wave output with zero transfer time offers compatibility with all equipment types IGBT inverter technology produces output power with lt 3 THD total harmonic distortion allowing connected equipment to perform at its peak A 3 1 crest factor safely supports a variety of equipment even those with wildly fluctuating power demands Extremely efficient operation saves money by lowering electricity consumption Hardwire input and output connections support a variety of permanent or PDU style power connections SU30K3 3 features 120 208V AC 3 phase 4 wire plus ground wye input and output It also features a wide input voltage correction range 96 144 166 250V AC Frequency is 50 or 60 Hz auto selectable SU30K3 3 includes internal power and battery components in a single small footprint tower module Battery support can be extended with additional internal battery packs A manual bypass switch as well as an automatic bypass function ensure 100 availability of connected equipment by safely passing through AC power when the UPS requires maintenance Three built in communication ports RS 232 contact closure and AS 400 work with included PowerAlert Software to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories An accessory slot accepts an optional internal SNMP card model SNMPWEBCARD for remote shutdowns r
Download Pdf Manuals
Related Search
Related Contents
HMDX HX-P130 Vantec NST-D400S3 IO テスト PE 標識抗体 CD20 IOB20a MolenbeekInfo 16Mars2006 - Molenbeek-Saint-Jean Repeater Troubleshooting Guide Examples of TNC Fujitsu B line 24W-7 Magelis Panel PC - GTW and Optimum - User Manual Smeg A1C-6 cooker 2015 January Bridal Exhibitor Service Manual.pub Copyright © All rights reserved.