Home

Cisco 500GB SATA

image

Contents

1. 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 8 of 24 STEP 6 Select option cards from the following list You can select a maximum of 10 PCle cards STEP 7 Select option cards Cisco UCS P81E Virtual Interface Card Dual port 10Gbps Max 2 Supported in slots 1 amp 2 Broadcom NetXtreme II 5709 Quad Port Ethernet PCle Adapter Card with TCP Offload Engine TOE and iSCSI HBA Broadcom NetXtreme II 57711 Dual Port 10 GbE PCle Adapter Card with TCP Offload Engine TOE and iSCSI HBA Emulex LightPulse LPe11002 4 Gbps Fibre Channel PCle Dual Channel HBA Emulex Converged Network Adapter Dual port 10Gb Emulex 8Gb HBA Light Pulse LP e12002 Intel 10GbE Dual port Niantec Controller with Copper SFP Cable Intel Quad port GbE HBA Mellanox Connect X 2 EN with dual 10GbE SFP ports QLogic QLE8152 Dual Port 10 Gbps PCle Converged Network Adapter CNA QLogic SANblade QLE2462 Dual Port 4 Gbps FC to PCl Express HBA QLogic QLE2562 8Gb Dual Port Fibre Channel HBA Select redundant power supply units N2XX ACPCI01 N2XX ABPCI03 N2XX ABPCI02 N2XX AEPCI03 N2XX AEPCIO1 N2XX AEPCI05 N2XX AIPCI01 N2XX AIPC102 N2XX AMPCI01 N2XX AQPCI01 N2XX AQPCI03 N2XX AQPCI05 In two processor configuration two power supplies come standard with the base chassis and you can order up to two redundant power supplies In a four processor configuration four power supp
2. Ajaj CISCO 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information SpecSheet Cisco UCS C460 M2 High Performance Rack Mount Server Overview The Cisco UCS C460 M2 High Performance Rack Mount Server Figure 1 is a four rack unit 4RU server supporting the Intel Xeon processor E7 4800 product family up to 1 terabyte TB of double data rate 3 DDR3 memory in 64 slots and 12 small form factor SFF hot pluggable SAS and SATA disk drives Abundant I O capability is provided by 10 PCI Express PCle slots supporting the Cisco UCS C Series network adapters with an eleventh PCle slot reserved for a hard disk drive array controller card Additional I O is provided by two Gigabit Ethernet LAN on motherboard LOM ports two 10 Gigabit Ethernet ports and two dedicated out of band OOB management ports Figure 1 Cisco UCS C460 M2 High Performance Rack Mount Server S Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs Page 1 of 24 Detailed Views Figure 2 Front View of the Cisco UCS C460 M2 Server 12x SAS SATA 25 HDD SSD Operator 3x USB TED Panel Panel 20 Ports Figure 3 Detailed View of Front Panels on the Cisco UCS C460 M2 Server 3x USB 20 Hard Drive Fan Fault System Reset Ports Status LE
3. dedicated SAS riser slot Figure 7 PCle Slots on the Cisco UCS C460 M2 Server a TE pg i t ail Table 3 PCle Card Specifications for the Cisco UCS C460 M2 Server PCle slot PCle cards PCle slot PCle cards PCle Gen2 x8 3 4 length PCle Gen2 x8 3 4 length hot plug 2 PCle Gen2 x8 3 4 length hot plug 7 PCle Gen2 x8 3 4 length hot plug 3 PCle Gen2 x8 1 2 length 8 PCle Gen2 x8 3 4 length 4 PCle Gen2 x4 1 2 length 9 PCle Gen1 x4 1 2 length 5 PCle Gen2 x16 3 4 length 10 PCle Gen1 x4 1 2 length Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 19 of 24 RAID Controller Notes The SAS riser card is installed at PCle slot 11 the SAS riser slot The SAS riser card supports 12 SAS SATA ports when used in conjunction with the SAS Expander backplane The SAS riser board LSI MegaRAID SAS 9260 8i supports the following features e Form factor PCle Low Profile H x L 2 72 x 6 60 inches e LSI SAS2108 Liberator ROC RAID On a Chip Controller at 800 MHz e PCle x8 card edge also compatible with x16 lane slots 5 Gbps or 2 5 Gbps serial transfer rate e Two internal Mini SAS 4i connectors e Eight channels of SAS SA
4. x 6 60 inches e LSI SAS2008 PCI Express SAS SATA I O processor chip e PCle x8 card edge also compatible with x16 lane slots 5 Gbps or 2 5 Gbps serial transfer rate e Two internal Mini SAS 4i connectors e Eight channels of SAS SATA at up to 6 Gb per second SAS rates of 6 0 Gb per second and 3 0 Gb per second SATA rates of 3 0 Gb per second and 1 5 Gb per second e Hardware RAID levels 0 1 5 10 50 and JBOD mode e Supports drive hot plugging e System Enclosure Specification SES connectivity through 12C cable or SGPIO e UART and JTAG debug ports Refer to LSI MegaRAID SAS 9240 8i Product Specification or visit the following site for a detailed description of this board http www I si com storage home products home internal raid megaraid sas entry line megaraid sas 9240 8i index html Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 21 of 24 Technical Specifications Physical Dimension Specifications Table 4 Physical Dimension Specifications for the Cisco UCS C460 M2Server pDimenston section Height Width Depth Front Clearance Side Clearance Rear Clearance Weight 6 8 in 173 8 mm 16 7 in 424 mm 27 7 in 704 mm 3 in 76 mm 1 in
5. 066MHz 32 Good pairs 1B 1D Performance 256GB 1A 1Cinboth 8x8GB 0 64GB 1066MHz 32 peak 512GB risers 8x16GB 0 128GB 1066MHz 32 oe 0 94x 256GB 8 identical 8x4GB 8x4GB 64GB 1066MHz 64 Best pairs both Performance 512GB raisers fully 8x8GB 8x8GB 128GB 1066MHz 64 peak 1TB populate 8x16GB 8x16GB 256GB 1066MHz 64 parca 640GB 8 mixed pairs 8x16GB 8x4GB 160GB 1066MHz 64 Best both raisers Performance 768GB fully populated 8x16GB 8x8GB 192GB 1066MHz 64 peak 384GB 8x8GB 8x4GB 96GB 1066MHz 64 panei 8 Mem1 for CPU1 Mem3 for CPU2 Mem5 for CPU3 and Mem7 for CPU4 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD RAID RAID Controller Notes Software Physical Specs Services Power Specs Memory Notes Environmental Specs Option Cards PCle Slot Notes 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 17 of 24 Figure 6 Memory Riser Board on the Cisco UCS C460 M2 Server Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 18 of 24 PCle Slot Notes As Figure 7 shows the Cisco UCS C460 M2 Server has 10 PCle slots available There are a total of 11 slots one is a
6. 25 mm 6 in 152 mm 110 23 Ibs 50 kg Note The system weight listed here is an estimate for a fully configured system and will vary depending on number of peripheral devices Power Specifications Table 5 Power Specifications for the Cisco UCS C460 M2 Server Voltage 115 90 Vrms 100 127 Vrms Voltage 220 180 Vrms 200 240 Vrms Frequency 47 Hz 50 60 Hz 140 Vrms 85VAC 4VAC 75VAC 5VAC 264 Vrms 63 Hz Note AC input connector is an IEC 320 C 14 15A 250VAC power inlet For configuration specific power specifications use the Cisco UCS Power Calculator http www cisco com assets cdc_content_elements flash dataCenter cisco_ucs power _calculator Contents Overview Detailed Views Option Cards RAID PCle Slot Notes RAID Controller Notes Physical Specs Base Unit Features Configuring Memory HDD Software Services Memory Notes Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 22 of 24 Table 6 Plug and Connector Part Numbers for the Cisco UCS C460 M2 Server Part Number CAB 9K12A NA 125VAC 13A NEMA 5 15 PLUG NEMA 5 15P IEC60320 C15 CAB AC 250V 13A NEMA L6 20 250V 20A NEMA L6 20 IEC60320 C13 IEC320 C13 PLUG CAB C13 C14 JMPR RECESSED RECEPTICAL AC SS10A HS10S CAB N5K6A NA 200 240V 6A NEMA 6 15P IEC60320 C13 R2XXDMYMPWRCORD NO POWER CORD N A N A Figure 8 Plugs and Conne
7. 6 GB maximum 512 GB 4 processor configuration Minimum 32 GB maximum 1024 GB The Cisco UCS C460 M2 server has four processor sockets and each socket has two memory risers Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 16 of 24 Table 2 CPU and Memory Riser Mapping UCS C460 server has 4 processor sockets each socket has 2 memory risers The following table shows the placement of the CPU and their corresponding memory risers Mem7 Mem5 Mem3 Mem1 DIMMs in DIMMs in Total memory Total of Memory Size in pairs per Bank 1 slots Bank 2 slots size per CPU Operation DIMMs in the Performance C460 M1 processor on a riser on a riser Speed system socket each blue color CET tere ola socket has two slots labeled slots labeled risers as 1B 1D 1A as 2B 2D 2A 1C 2C 32GB 1 pair 1B 1D 2x4GB 0 8GB 1066MHz 8 Poor peak in odd labeled bandwidth 64GB risers 2x8GB 0 16GB 1066MHz 8 0 25x 128GB 2x16GB 0 32GB 1066MHz 8 64GB 2 identical 4x4GB 0 16GB 1066MHz 16 Average peak pairs 1B 1D in bandwidth 128GB both riser 4x8GB 0 32GB 1066MHz 16 0 50x 256GB 4x16GB 0 64GB 1066MHz 16 128GB 4 identical 8x4GB 0 32GB 1
8. CAB 9K10A AU SFS 250V 10A CN CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS CAB 9K10A IT CAB 9K10A SW CAB 9K10A UK CAB 9K12A NA CAB C13 C14 2M CAB JPN 3PIN A rail kit is included with all Cisco UCS C460 M2 servers The cable management arm CMA is used for cable management and hooks onto the rail kit Contents Overview Detailed Views Base Unit Features Configuring Option Cards RAID software Services PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Cable Management Arm R460 CBLARM Memory HDD Memory Notes Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 10 of 24 STEP 10 Order the internal Flash USB device optional You can order a maximum of two Flash USB devices e 2 GB internal Flash USB device RC460 EUSB STEP 11 Select the operating system optional Various operating system options are available Select from this list SUSE Linux Enterprise Server e SLES 1yr subscription svcs required O media SLES 1A e SLES 8yr subscription svcs required 0 media SLES 3A Red Hat Enterprise Linux e RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2S 1G 1A e RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL 4 Socket 1 Guest 1Yr Svcs Required RHEL 4 So
9. D System LED System Button Status LED Power LED System ID LED PSU Status LED Memory Status LED Sm yen ystem ystem Power ORU aa Button Button NIC Status NMI LED Button Video Connector Contents Overview Detailed Views Base Unit Features Configuring Option Cards RAID Software Services PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Memory HDD Memory Notes Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 2 of 24 Figure 4 Rear View of the Cisco UCS C460 M2 Server SAS Riser VO Riser 10x PCle Slot Module Slots 2x USB 4x Power 2 0 Ports Supplies Figure 5 Detailed View of the I O Riser Module on the Rear of the Cisco UCS C460 M2 Server 2x 10Gb SFP 2x 1Gb RJ 45 2 x Management Ports RJ 45 System Status LED System ID LED 2x 10Gb 10GbaseT Serial Port DB9 VGA Port DB15 2x sa System ID Button Contents Overview Detailed Views Base Unit Features Option Cards RAID Software PCle Slot Notes RAID Controller Notes Physical Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Services Power Specs Memory HDD Memory Notes Environmental Specs Page 3 of 24 Base Unit Features Table 1 Feature Specifications for the Cisco UCS C460 M2 Server CPU Chipset Memory NIC Expansion slots Storage c
10. ON UCW3 C460M2 e UC Warranty Plus 8X5XNBD On Site CON UCW5 C460M2 For more information consult Unified Computing Warranty and Support Services For a complete listing of available Services for Cisco Unified Computing System visit Unified Computing Services Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 15 of 24 Product Notes Memory Notes A factory memory mirroring option is available RAID 1 is to storage as memory mirroring is to memory System administrators can configure their Cisco UCS C460 M2 server to maintain a mirrored copy of the information contained in memory Note Memory mirroring is available only when banks 1 and 2 are populated with identical DIMMs There are 16 DIMM slots per CPU eight per memory riser board System performance is optimized when memory type and quantity is equal for all memory channels on all CPUs The UCS C460 M2 server has four memory channels per CPU DIMMs must be inserted in pairs and from the same DIMM manufacturer This is the reason for DIMM kits on the C460 M2 All DIMMs supported on the C460 M2 are registered buffered DIMMs The following memory capacities are supported 2 processor configuration Minimum 1
11. RM e Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL MSWS 08R2 ENHV RM e Windows Svr 2008 ST media R2 DC 1 8CPU 25CAL MSWS 08R2 DCHV RM STEP 12 Select from a variety of value added software optional e BMC BladeLogic CM for Virtualized Cisco Servers BMC 001 e BMC Blade Logic Compliance VM Bundle 2 Socket Server BMC 001 COMP e BMC BladeLogic CM for Physical Cisco Servers BMC 002 e BMC Blade Logic Compliance Single OS BMC 002 COMP e BMC Bladelogic CM Virtualized 4 Socket Server BMC 003 e BMC Blade Logic Compliance VM Bundle 4 Socket Server BMC 003 COMP e BMC BPPM Per Server BMC 012 e VMware vCenter Server Standard 1yr 24x7 support VMW VCS 1A e VMware vCenter Server Standard 3yr 24x7 support VMW VCS 3A e Nexus 1000V License PAK for 1 Virtual Ethernet module N1K VLEM UCS 1 e Nexus 1000V VSM Virtual Appliance Software N1K CSK9 UCS 404 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 13 of 24 STEP 13 Select the appropriate services optional A variety of service options are available as listed here Cisco Unified Computing Mission Critical Support Service This service delivers personalized technical account management expedited technical support and expert field suppo
12. TA at up to 6 Gbps SAS rates of 6 0 Gbps and 3 0 Gbps SATA rates of 3 0 Gbps and 1 5 Gbps e Hardware RAID levels 0 1 5 6 10 50 and 60 e Supports drive hot plugging e 5 Chip DDR2 on board memory running at 800 MHz 64 bit with error correcting code ECC for enhanced hardware RAID performance e 512 MB on board DDR2 800 cache arranged as 64Mx16 devices 1 Gb capacity e iBBU support direct connected iBBU07 RAID Battery Back up module for DDR2 DIMM refresh support during a power failure e 8 MB CFI Compliant Flash ROM and a 32 kB NVSRAM nonvolatile SRAM for disk and drive setup information storage e System Enclosure Specification SES connectivity through 12C cable or SGPIO e UART and JTAG debug ports Refer to LSI MegaRAID SAS 9260 8i Product Specification or visit the following site for a detailed description of this board http Awww lsi com storage home products home internal raid megaraid sas 6gb s value line sas9260 8i index html locale EN amp remote 1 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 20 of 24 The SAS riser board LSI MegaRAID SAS 9240 8i supports the following features e Form factor PCle Low Profile H x L 2 536
13. ardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment e UC Support 8X5XNBD Not on site CON UCS1 C460M2 e UC Support 8X5X4 Not on site CON UCS2 C460M2 e UC Support 24x7x4 Not on site CON UCS3 C460M2 e UC Support 24x7x2 Not on site CON UCS4 C460M2 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 14 of 24 e UC Support 8X5XNBD On site CON UCS5 C460M2 e UC Support 8X5X4 On site CON UCS6 C460M2 e UC Support 24x7x4 On site CON UCS7 C460M2 e UC Support 24x7x2 On site CON UCS8 C460M2 Cisco Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service Customers can choose from several levels of advanced parts replacement coverage including onsite parts replacement in as little as two hours Warranty Plus provides remote access anytime to Cisco support professionals who can determine if a return materials authorization RMA is required e UC Warranty Plus 24x7x4 C
14. cket 1 Guest 3Yr Svcs Required RHEL 4 Socket 4 Guest 1Yr Svcs Required RHEL 4 Socket 4 Guest 3Yr Svcs Required RHEL 4 Socket U Guest 1Yr Svcs Required RHEL 4 Socket U Guest 3Yr Svcs Required PCle Slot Notes RAID Controller Notes Physical Specs Power Specs RHEL 2S 1G 3A RHEL 2S 4G 1A RHEL 2S 4G 3A RHEL 2S UG 1A RHEL 2S UG 3A RHEL 4S 1G 1A RHEL 4S 1G 3A RHEL 4S 4G 1A RHEL 4S 4G 3A RHEL 4S UG 1A RHEL 4S UG 3A Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 11 of 24 RHEL Add Ons e High Availability 2 Socket 1Yr Svcs Required RHEL HA 2S 1A e High Availability 2 Socket 3Yr Svcs Required RHEL HA 2S 3A e High Availability 4 Socket 1Yr Svcs Required RHEL HA 4S 1A e High Availability 4 Socket 3Yr Svcs Required RHEL HA 4S 3A e Resilient Storage With Ha 2 Socket 1 Yr Svcs Required RHEL RS 2S 1A e Resilient Storage With Ha 2 Socket 3 Yr Svcs Required RHEL RS 2S 3A e Resilient Storage With Ha 4 Socket 1 Yr Svcs Required RHEL RS 4S 1A e Resilient Storage With Ha 4 Socket 3 Yr Svcs Required RHEL RS 4S 3A e Scalable File System 2 Socket 1 Yr Svcs Required RHEL SFS 2S 1A e Scalable File System 2 Socket 3 Yr Svcs Required RHEL SFS 2S 3A e Scalable File System 4 Socket 1 Yr Svcs Required RHEL SFS 4S 1A e Scalable File System 4 S
15. ct the RAID controller option If your system includes SAS or SATA drives you must choose a RAID controller Contents Overview Detailed Views Base Unit Features Configuring Option Cards RAID Software Services PCle Slot Notes RAID Controller Notes Physical Specs Power Specs LSI Controller 9240 8 Installs in dedicated SAS riser PCle slot on a C460 M2 Supports up to 12 SAS or SATA drives Supports RAID 0 1 5 10 50 o o No battery backup option available LSI Controller 9260 8i Installs in dedicated SAS riser PCle slot on a C460 M2 Supports up to 12 SAS or SATA drives Supports RAID 0 1 5 6 10 50 or 60 Includes 512 MB of write cache Battery backup option available 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information RC460 PL002 RC460 PL001 Memory HDD Memory Notes Environmental Specs Page 6 of 24 e LSI 6G MegaRAID 9280 4i4e PCle Card UCSC C 414E o Takes up one of five available PCle slots Supports up to sixteen SAS and or SATA drives Supports external JBOD expansion Battery Back Up Option Available e Battery Backup Option RC460 LBBU STEP 4 Select the 2 5 inch HDD drive type Select a minimum of zero and a maximum of 12 drives from this list e 500 GB SATA 7 2k RPM SFF HDD hot plug C Series drive sled R2XX D500GCSATA e 1 TB SATA 7 2k RPM SFF HDD hot plug C Series drive sled A03 D1TBSATA e 73 GB 6Gb SAS 15k RPM SFF HDD
16. ctors for the Cisco UCS C460 M2 Server hs am Plug Connector Plug Connector Plug Connector NEMA 5 15P IEC30620 C15 EL312MoldedTwistlock HS10S SS10A IEC30620 C 13 NEMA L6 20 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 23 of 24 Environmental Specifications Table 7 Environmental Specifications for the Cisco UCS C460 M2 Server Temperature operating 10 C to 35 C 50 F to 95 F Temperature nonoperating 40 C to 70 C 40 F to 158 F Altitude 30 to 1 500 m 100 to 5 000 ft Humidity nonoperating 95 noncondensing at temperatures of 25 C 77 F to 30 C 86 F Vibration nonoperating 2 2 Grms 10 minutes per axis on each of the three axes Shock operating Half sine 2 G 11 ms pulse 100 pulses in each direction on each of the three axes Shock nonoperating Trapezoidal 25 G two drops on each of six faces AV 175 inches sec on bottom face drop 90 inches sec on other 5 faces Safety UL60 950 CSA60 950 AS NZS 3562 GB4943 1995 EN60 950 and 73 23 EEC IEC 60 950 EMKO TSE 74 SEC 207 94 GOST R 50377 92 Emissions Certified to FCC Class A tested to CISPR 22 Class A EN 55022 Class A and 89 336 EEC VCCI Class A AS NZS 3548 Cla
17. hot plug drive sled mounted A03 D073GC2 e 146 GB 6Gb SAS 15k RPM SFF HDD hot plug drive sled mounted A03 D146GC2 e 300 GB 6Gb SAS 10k RPM SFF HDD hot plug drive sled mounted A03 D300GA2 e 600 GB 6Gb SAS 10k RPM SFF HDD hot plug drive sled mounted A03 D600GA2 Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 7 of 24 STEP 5 Select a factory configured RAID setup Most customers prefer to configure their own RAID setup If you would prefer that Cisco to configure the RAID choose one of the following options e RAID 0 Striping R2XX RAIDO Requires a minimum of one hard drive e RAID 1 Mirroring R2XX RAID1 Requires exactly two hard drives with same size speed and capacity e RAID5 R2XX RAID5 Requires a minimum of three HDDs all with identical speed and capacity e RAID6 R2XX RAID6 Requires a minimum of four HDDs all with identical speed and capacity e RAID 10 R2XX RAID10 Requires a minimum of four HDDs all with identical speed and capacity Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PGle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs
18. lect the CPU type Select two or four CPUs from this list e 2 4 GHz Xeon E7 4870 130W 10C CPU 30MB cache UCS CPU E74870 e 2 26 GHz Xeon E7 4860 130W 10C CPU 24MB cache UCS CPU E74860 e 2 0 GHz Xeon E7 4850 130W 10C CPU 30MB cache UCS CPU E74850 e 2 13 GHz Xeon E7 4830 105W 8C CPU 24MB cache UCS CPU E74830 e 1 86 GHz Xeon E7 4807 95W 6C CPU 18MB cache UCS CPU E74807 e 2 60 GHz Xeon E7 8837 130W 8C CPU 24MB cache UCS CPU E78837 e 2 13 GHz Xeon E7 8867L 105W 10C CPU 30MB cache UCS CPU E78867L Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 5 of 24 STEP 2 Select the memory type Select a minimum of one and a maximum of 32 DIMM kits from the following list Note 8 GB DDR3 1333 MHz RDIMM PC3 10600 2 x 4GB Kit Low Dual Volt 16 GB DDR3 1333 MHz RDIMM PC3 10600 2 x 8GB Kit Low Dual Volt 32GB DDR3 1066MHz RDIMM PC3 8500 2 x 16GB 4R Kit Low Dual Volt 8GB DDR3 1333MHz RDIMM PC3 10600 2 x 4GB 2R Kit 16GB DDR3 1333MHz RDIMM PC3 10600 2 x 8GB 2R Kit Factory Memory Mirroring Option A02 M308GB3 2 A02 M316GB3 2 A02 M332GB3 2 L A02 M308GD5 2 A02 M316GD5 2 N01 MMIRROR Memory mirroring is available only when banks 1 and 2 are populated with identical DIMMs STEP 3 Sele
19. lies come standard with the base chassis and no extra power supplies are needed Contents Overview Detailed Views Base Unit Features Configuring Option Cards RAID Software Services 850W Power Supply Unit for C Series C460 PCle Slot Notes RAID Controller Notes Physical Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Power Specs RC460 PSU2 850W Memory HDD Memory Notes Environmental Specs Page 9 of 24 STEP 8 Select the power cords optional You can select a maximum of two power cables from this list STEP 9 N5000 AC Power Cable 6A 250V North America 2 5m N5000 AC Power Cable 13A 250V North America 2 5m N5000 AC Power Cable 6A 250V Power Strip Type N5000 AC Power Cable 10A 250V Argentina 2 5m N5000 AC Power Cable 10A 250V Australia 2 5m N5000 AC Power Cable 10A 250V China 2 5m N5000 AC Power Cable 10A 250V Europe 2 5m N5000 AC Power Cable 10A 250V India 2 5m N5000 AC Power Cable 10A 250V Israel 2 5m N5000 AC Power Cable 10A 250V Italy 2 5m N5000 AC Power Cable 10A 250V Switzerland 2 5m N5000 AC Power Cable 10A 250V United Kingdom 2 5m N5000 Power Cord 125VAC 15A NEMA 5 15 Plug North America 2 5m Power Cord Jumper C13 C14 Connectors 2 Meter Length Power Cord 3 PIN Japan Order the cable management arm optional CAB N5K6A NA CAB AC 250V 13A CAB C13 C14 JMPR SFS 250V 10A AR
20. ocket 3 Yr Svcs Required RHEL SFS 4S 3A Windows Server e Windows Svr 2008 ST media 1 4CPU 5CAL MSWS 08 STHV e Windows Svr 2008 EN media 1 8CPU 25CAL MSWS 08 ENHV e Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL MSWS 08R2 STHV e Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL MSWS 08R2 ENHV e Windows Svr 2008 R2 2 CPU Data Center MSWS 08R2 DCHV2S e Windows Svr 2008 R2 4 CPU Data Center MSWS 08R2 DCHV4S VMware Server e VMware vSphere Advanced 1 CPU 1yr 24x7 support VMW VS ADV 1A e VMware vSphere Advanced 1 CPU 3yr 24x7 support VMW VS ADV 3A e VMware vSphere Enterprise 1 CPU 1yr 24x7 support VMW VS ENT 1A e VMware vSphere Enterprise 1 CPU 3yr 24x7 support VMW VS ENT 3A e VMware vSphere Enterprise Plus 1 CPU 1yr 24x7 support VMW VS ENTP 1A e VMware vSphere Enterprise Plus 1 CPU 3yr 24x7 support VMW VS ENTP 3A Contents Overview Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 12 of 24 Select an operating system media kit optional e RHEL 6 Media Only Multilingual RHEL 6 e SLES 11 media only multilingual SLES 11 e Windows Svr 2008 ST media MSWS 08 STHV RM e Windows Svr 2008 EN media MSWS 08 ENHV RM e Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL MSWS 08R2 STHV
21. ontroller Internal storage devices Interfaces Power subsystem Fans Integrated management processor Contents Overview Up to four Intel Xeon E7 4800 Series processors Intel 7510 chipset 64 DIMM slots up to 1 TB Embedded dual port Broadcom BCM57711 PCle based 10 Gigabit Ethernet controller and dual port Broadcom BCM5709c Gigabit Ethernet 10 PCle slots see PCle Slot Notes for details LSI MegaRAID SAS 9260 8i LSI Controller 9240 8i LSI SAS2108 Liberator ROC RA D On a Chip Controller at 800 MHz Hardware RAID levels 0 1 5 6 10 50 and 60 Up to 12 SAS SATA hot swappable hard disk drives HDD or solid state drives SSD Up to two optional internal 2 GB eUSB devices Serial USB VGA PCle RJ 45 GG 45 Small Form Factor Pluggable Plus SFP Up to four 850W power supplies N N N 1 or No redundancy Eight 80mm hot swappable fans Cisco UCS C Series Integrated Management Controller CIMC with integrated video KVM redirection SIO fan speed control PECI voltage monitoring Detailed Views Base Unit Features Configuring Memory HDD Option Cards RAID Software Services Memory Notes PCle Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 4 of 24 Configuring the Cisco UCS C460 M2 Server UCS C460 M2 base server required UCSC BASE M2 C460 STEP 1 Se
22. rt engineering for the Cisco Unified Computing System The Mission Critical Support Service provides a designated technical account manager TAM who acts as a strategic resource to help assure the unified computing environment runs at peak efficiency Should a problem arise that threatens business continuity the TAM provides crisis management leadership and customer IT staff gets expedited access to Cisco s award winning Technical Assistance Center TAC Please note This service has qualification criteria There should be US 1 2 million of UCS equipment 200 blades and a single location to qualify for this service level e UC Mission Critical 24x7x4 On site CON UCM7 C460M2 e UC Mission Critical 24x7x2 On site CON UCM8 C460M2 Cisco Unified Computing Support Service For support of the entire Unified Computing System Cisco offers the Cisco Unified Computing Support Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment This service includes access to the award winning Cisco Technical Assistance Center TAC around the clock from anywhere in the world For Cisco UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include the Cisco UCS Manager the support service includes downloads of UCS Manager upgrades The Unified Computing Support Service includes flexible h
23. ss A ICES 003 Class A GB9254 1998 MIC Notice 1997 42 Class A GOST R 29216 91 Class A BSMI CNS13438 Immunity Verified to comply with EN55024 CISPR 24 GB9254 1998 MIC Notice 1997 41 GOST R 50628 95 Electrostatic discharge Tested to ESD levels up to 15 kilovolts kV air discharge and up to 8 kV contact discharge without physical damage Acoustic Sound power lt 7 0 BA at ambient temperature lt 23 C measured using the Dome Method GOST MsanPiN 001 96 For More Information Please visit http www cisco com go ucs Ajaj Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the U S and other countries A listing of Cisco s trademarks can be found at www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R Printed in USA C17 662220 00 05 11 2011 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 24 of 24

Download Pdf Manuals

image

Related Search

Related Contents

Bosch FNH180KL-16 Use and Care Manual  Garantie limitée de 10 ans pour le système  ダウンロード(PDF 0.28MB)  Zakât officielle et zakât non officielle aujourd`hui en Egypte  APC UTS6BI Switch User Manual  KOBOLD SM FLOWMETER/SWITCH User Instructions  Télécharger le dossier de candidature  KYOCERA DF-470  - AJ Pinto  Fiskars ShapeBoss  