Tripp Lite SmartOnline 200-240V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, DB9 Serial

image

Contents

1. detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications Communications Cable DB9 cable included AC Mode Efficiency Rating 100 o 88 Load WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Low Voltage Transfer to Battery 160V 100 load 130V lt 70 load Power Setpoint High Voltage Transfer to Battery 275 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode ii During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries Green Energy Saving Features Individually controllable load banks CERTIFICATIONS UPS Certifications Meets FCC Part 15 Category A EMI Tested to NOM Mexico Tested to UL1778 USA 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance i U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may
2. 5th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Load Management Receptacles Two switchable 6 15 20R load banks bank 1 two outlets bank 2 four outlets INPUT BATTERY Battery Recharge Rate Included Batteries Internal UPS Replacement Battery RBC96 3U Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Overvoltage Correction Maintains output during overvoltages to 275 Undervoltage Correction Maintains output during undervoltages to 160V AC Severe Undervoltage Correction At load levels less than 70 UPS maintains output during undervoltages to 130V AC USER INTERFACE ALERTS amp CONTROLS 2 switches control off on power status and alarm cancel self test operation Alarm Cancel Operation Power fail alarm can be silenced using alarm cancel switch Less than 6 hours from 10 to 80 typical full load discharge 3 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions 14 LEDs indicate line power online mode bypass mode on battery overload battery low replace battery and fault LED Indicators status information 4 LED meter displays loa
3. TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 200 240V 3kVA 2 4kW On Line Double Conversion UPS Extended Run SNMP Webcard 3U Rack Tower DB9 Serial MODEL NUMBER SU3000RTXL3UHV Description 3000VA 3kVA on line double conversion UPS system for critical server network and telecommunications equipment 3U rackmount form factor with an installed depth of 20 inches 50 8cm Expandable battery runtime with optional external battery packs BP72V15 2U limit 1 BP72V28RT 3U multi pack compatible and BP72V18 2US multi pack compatible Full time sine wave 200 208 220 240V AC output with 2 voltage regulation Online double conversion Uninterruptible Power Supply UPS actively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without using battery power during brownouts to 130V and overvoltages to 275V NEMA L6 20P input plug NEMA 6 15 20R amp L6 20R output receptacles Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support simultaneous communications via DB9 serial port and SNMPWEBCARD slot Built in DB9 port offers both enhanced RS 232 enabled Highlights e 3000VA 3kVA 2400 watt on line double conversion 3U rack tower UPS 208 240V 2 output at 50 60Hz Expandable runtime Ho
4. d and battery charge levels LED panel rotates for viewing in rack tower formats SURGE NOISE SUPPRESSION UPS AC Suppression Joule Rating 2670 Tine ii ia Time OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits EMI RFI AC Noise Suppression 2670 PHYSICAL Installation Form Factors Supported i f with Included Accessories 6 6 15 20R 2 C6 20R Included Mounting Accessory Includes 4 post rackmount installation accessories Description Installation Form Factors Supported 2 post rackmount 2POSTRMKITHD Tower 2 9USTAND with Optional Accessories UPS Dataline Suppression UPS Power Module Dimensions 5 2x17 3x 19 8 hwd in UPS Power Module Dimensions 13 2 x 43 9 x 50 3 hwd cm i OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Stepdown Transformer Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd in frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 l
5. differ slightly from final products 6 6
6. gh blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e Accepts input voltages between 160 and 275 130 to 275 at loads under 70 regulating output to selectable 200 208 220 240V 2 e 3000VA 2400 watt power capacity with 8 total outlets 6 NEMA6 15 20R amp 2 NEMAL6 20R e Standard internal battery set provides 14 minutes runtime at half load 1 6 TRIPP LITE Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Expandable runtime with external battery packs BP72V15 2U limit 1 BP72V28RT 3U multi pack compatible and BP72V18 2US multi pack compatible e Innovative design makes unit adaptable for rackmount tower or stacking applications e Uses only 3 rack spaces 3U in standard 19 inch rack e DB9 serial port for network interface SNMP compatible e Slot for optional SNMP web card part SNMPWEBCARD e PowerAlert unattended shutdown software and 6 ft network cable included e Compatible with Tripp Lite s Watchdog Service Monitoring Reboot Software e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Diagnostic LEDs e Battery replacement door e Mounting hardware included for 4 post rack enclosures tower placement supported with optional 2 9USTAND accessory 2 post telecom rack compatible wit
7. h optional 2POSTRMKITHD accessory e 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only Specifications OUTPUT Output Capacity Details Output Volt Amp Capacity VA Output kVA Capacity kVA Output Watt Capacity Watts Output kW Capacity kW Power Factor Crest Factor Nominal Output Voltage s Supported Nominal Voltage Details Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation Line Mode Output Voltage Regulation Battery Mode Output Receptacles UPS Output Receptacles Surge Suppression Only OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits 3000 2400 3 200V 208V 220V 240V 208V default 50 60 Hz Output frequency matches input nominal on startup defaults to 60 Hz on cold start 6 6 15 20R 2 L6 20R OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits 2 6 Tripp Lite 1111 W 3
8. oad for 3 minutes 150 Stepdown Transformer Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd cm frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Included Battery Pack Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd in frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Included Battery Pack Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd cm frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits 416 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com UPS Shipping Dimensions hwd 33 8 x 60 5 x 65 3 cm i ENVIRONMENTAL 0 to 95 non condensing UPS Shipping Dimensions hwd in 13 3 x 23 8 x 25 7 COMMUNICATIONS Communications Interface Contact closure DB9 Serial Slot for SNMP Web interface Network Monitoring Port Description Supports
9. t swappable battery modules RS232 port support for SNMP WEB card options Front panel status LEDs with detailed load and battery metering NEMA L6 20P input 6 15 20R amp L6 20R outlets Applications Distributed Server Rooms Network Closets Small Business Networks Voice over IP VoIP Phone Systems Package Includes SU3000RTXL3UHV Rack Tower UPS System PowerAlert Software and cabling Mounting hardware for 4 post rackmount enclosures Warranty information Instruction manual monitoring data plus contact closure monitoring ability Supports simultaneous detailed monitoring of equipment load levels self test data and mains power conditions via all network interfaces Includes PowerAlert monitoring software and complete cabling Integrated two bank PDU switching supports load shedding and remote reboot of connected equipment Multi stage metered current monitoring and battery charge status LEDs Mains power and voltage regulation LEDs Audible Alarm Self test Fault tolerant auto bypass mode 4 post rackmount accessories included 2 9USTAND tower kit and 2POSTRMKITWM 2 post rackmount accessories available Field replaceable hot swappable internal batteries and external battery packs Attractive all black UPS design 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only Features e True on line double conversion UPS provides pure sine wave AC output at all times e Maintains continuous operation throu

Download Pdf Manuals

image

Related Search

Related Contents

  Copyright©2007 Tous droits réservés  Desfibrilador externo automático DDU  Foxit Enterprise Deployment and Configuration 7  DS-8100HFI-ST Series DVR USER MANUAL Version 2.0.2  Pro-Oceanus Co2-Pro User Manual  Mise en page 1 - Actu Assurance Vie. Le site de référence de l    télécharger  1 Indicaciones de seguridad 2 Estructura del mecanismo  