Home
Tripp Lite SmartOnline 100-120V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
Contents
1. Features 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Meets FCC Part 15 Category B EMI WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance ends U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6
2. S Dataline Suppression 1 line TEL DSL 1 in 1 _ 10 100Base T Ethernet EMI RFI AC Noise Suppression PHYSICAL OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Installation Form Factors Supported load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and with Included Accessories frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Installation Form Factors Supported load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and with Optional Accessories frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits UPS Power Module Dimensions 10x6 8x13 2 hwd in UPS Power Module Dimensions 25 4 x 17 1 x 33 7 hwd cm OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Stepdown Transformer Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd in frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load contin
3. Software part WATCHDOGSW e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Diagnostic LEDs e 250 000 Ultimate Lifetime Insurance U S Canada and Puerto Rico only Specifications OUTPUT OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits Output Volt Amp Capacity VA 1000 1 800 3 1 Output Capacity Details Crest Factor Nominal Output Voltage s 100V 110V 120V Supported i Nominal Voltage Details 120V default Frequency Compatibility 50 60 Hz Frequency Compatibility Details Output frequency matches input nominal on startup defaults to 60 Hz on cold start Output Voltage Regulation Line 2 Mode Output Voltage Regulation 10 Economy Line Mode Output Voltage Regulation Battery 4 90 Mode Output Receptacles 6 5 15R OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 UPS Output Receptacles Surge load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and Suppression Only frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency a
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 100 120V 1kVA 800W On Line Highlights Double Conversion UPS Extended Run SNMP eae a Webcard Tower USB DB9 Serial ouble conversion tower e 100 110 120V 2 output at MODEL NUMBER SU1000XLA et aes economy mode option e Expandable runtime Hot swappable battery modules e USB RS232 amp EPO ports support for SNMP WEB card options e Front panel status LEDs with detailed load and battery metering e 2 independently switchable output load banks e NEMA 5 15P input 5 15R outlets Package Includes e SU1000XLa Online UPS System e PowerAlert Software CD and cabling Description Tripp Lite s Smart Online SU1000XLa on line double conversion UPS protects critical server networking or 5 Gunera Mantaliniawanents telecommunications equipment from blackouts brownouts voltage fluctuations and surges in an attractive ON all black upright tower form factor Large capacity 1kVA 800 watt UPS continuously converts incoming AC to o EPO Emaraney Ponai of DC then back to perfect sine wave AC output at 120V AC 2 Removes harmonic distortion fast electrical cabling impulses frequency fluctuations and other hard to solve power problems not addressed by other UPS systems True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types Highly efficient operation in option
5. al economy mode setting saving BTU heat output and energy costs Includes 6 UPS supported outlets 2 single outlet load banks can be independently controlled via a software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment Extended runtime available with optional BP24V15RT2U BP24V28 2U or BP24V70 3U external battery packs Includes slot for internal SNMP web card plus DB9 enhanced serial monitoring port for unattended shutdown remote control and monitoring of UPS system and power data Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes Tripp Lite s PowerAlert UPS Power Management Software Compatible with Tripp Lite s Watchdog Service Monitoring Rebooting Software Features e True on line double conversion UPS provides a constant pure sine wave AC output e Maintains continuous operation through blackouts brownouts voltage fluctuations and surges with zero transfer time e Zero transfer time on line double conversion and economy mode operation supported e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e Accepts input voltages between 80 and 150 65 to 150 at loads under 70 regula
6. degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 406 4 AC Economy Mode BTU Hr Full 173 6 Load Battery Mode BTU Hr Full Load 406 4 AC Mode Efficiency Rating 100 o 87 Load AC Economy Mode Efficiency Rating 94 100 Load Audible Noise lt 45 dB at front side 1m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications PowerAlert Software Included Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Low Voltage Transfer to Battery 80V 100 load 65V lt 70 load Power Setpoint Network Monitoring Port Description High Voltage Transfer to Battery 150 Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode During a Power Failure Cold start operation supported High Availability UPS Features Automatic inverter bypass Hot swappable batteries High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation Green Energy Saving
7. re OUTSIDE bypass limits 2 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Load Management Receptacles Two switchable single outlet 5 15R load banks INPUT BATTERY DC System Voltage VDC Battery Recharge Rate Included Batteries Internal UPS Replacement Battery RBC24 SUTWR Cartridge Battery Access Battery access door Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION USER INTERFACE ALERTS amp CONTROLS 2 switches control off on power status and alarm cancel self test operation Power2 switches control off power operation and on power status alarm cancel self test cold start operation fail alarm can be silenced using alarm cancel switch 3 6 Less than 6 hours from 10 to 90 typical full load discharge Alarm Cancel Operation Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Front Panel LCD LED Indicators 14 LEDs indicate line power online mode economy bypass mode on battery overload battery low replace battery and fault status information includes 4 LED meter display for load and battery charge level SURGE NOISE SUPPRESSION UPS AC Suppression Joule Rating UPS AC Suppression Response Instantaneous Time UP
8. ting output to 120V AC 2 e 1000VA 800 wait output capacity with 6 total outlets 6 NEMA5 15R e Two built in individually switchable load banks can be controlled via software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment 2 banks of 1 outlet e Standard internal battery set provides 14 minutes runtime at half load and 4 minutes at full load 1 6 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Extended runtime available with optional BP24V15RT2U BP24V28 2U or BP24V70 3U external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Attractive all black upright tower format e Simultaneous communications use via HID compliant USB port serial port and SNMP web card slot e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e DB9 serial network interface supports RS 232 and contact closure messaging e Slot for optional SNMP web card part SNMPWEBCARD e Included PowerAlert UPS Power Management Software and cabling provides monitoring of in depth site power conditions full UPS status and fault warnings output load level and load bank power control e Compatible with Tripp Lite s WatchDog Service Monitoring Rebooting
9. uously 125 load for 3 minutes 150 Stepdown Transformer Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd cm frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Included Battery Pack Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd in frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits OVERLOAD CAPACITY Supports inverter operation up to 105 load continuously 125 load for 3 minutes 150 Included Battery Pack Dimensions load for 30 seconds and gt 150 load for 0 5 seconds before switching to BYPASS when bypass input voltage and hwd cm frequency are WITHIN bypass limits or SHUTDOWN when bypass input voltage or frequency are OUTSIDE bypass limits UPS Shipping Dimensions hwd in 14 2 x 10 x 18 5 UPS Shipping Dimensions hwd 36 2 x 25 4x 47 cm 416 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Shipping Weight kg Cooling Method Fan ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122
Download Pdf Manuals