Datalogic Memor Single Ethernet Cradle
Contents
1. Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada
2. battery charging TECHNICAL FEATURES Datalogic Memor Single Ethernet USB Host Cradle Electrical Features Power Supply 5 VDC 5 Consumption Max 2 5A Power on LED green Spare battery charge LED bi colored Ethernet LEDs green and yellow 1100 mAh Battery max 2 hours spare battery only max 3 hours with terminal and spare battery 2000 mAh Battery max 4 hours spare battery only max 6 hours with terminal and spare battery Indicators Charge Time Communication Features RS232 USB 2 0 version Ethernet 10 100 Interface Base T Baud Rate RS232 up to 115200 b sec USB up to 480 Mbps Ethernet up to 12 Mbps Environmental Features Working Temperature Storage Temperature Humidity 80 non condensing 0 to 50 C 32 to 122 F 20 to 70 C 4 to 158 F Mechanical Features Dj 105 X 75 X 102 mm 4 13 X 2 95 X 4 02 imensions in 340 g 12 0z Recommended power supply 94ACC1324 PG5 30P35 AC DC POWER SUPPLY EU USA PLUG Battery must be charged at a temperature ranging from 0 to 40 C For the GSM models the maximum recommended temperature is 35 C At higher values the charging may slow down Close to the limits of the working temperature some display and or battery performance degradation may occur FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use th
3. SDATALOGIC Datalogic Memor Single Ethernet USB Host Cradle The Datalogic Memor Single Ethernet USB Host Cradle paired with a Datalogic Memor mobile computer provides a solution for the collection decoding and transmission of barcode data Communication options for this accessory include Ethernet and serial or USB and serial The cradle also functions as a charger both for the mobile computer and a spare battery pack The spare battery pack recharging slot accommodates both 1100 mAh and 2000 mAh Battery packs GL olola A Figure 1 Datalogic Memor Single Ethernet USB Host Cradle A LED Indicators E Power Jack B Spare Battery Slot F Ethernet Port with LED indicators C Mini USB Connector G Switch Ethernet USB D RS232 Connector Read this manual carefully before performing any type of connection through the cradle The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual Do not attempt to disassemble the cradle as it does not contain parts that can be repaired by the user Any tampering will invalidate the warranty 822000911 Rev A COMPATIBILITY TABLE The Single Ethernet USB Host Cradle new technology is not compatible with previous versions of Datalogic Memor The following table shows the compatibility between the Datalogic Memor models and the two versions of the single ethernet cradle To h
4. e equipment This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Ilncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA ICES 003 COMPLIANCE This Class B digital apparatus complies with Canadian ICES 003
5. elp visually identify the new and old devices a set of yellow stickers has been included with the Datalogic Memor Single Ethernet USB Host Cradle Please apply these as needed to the front of your new devices to ensure expected communications 944201014 DL Memor 802 11g BT 1DGS WM6 1 944201015 DL Memor 802 11g BT 2D WM6 1 Datalogic 944201016 DL Memor Batch 1DGS CE5 oo 944201017 DL Memor EdgeE BT 1DGS WM6 1 ingle Ethernet 944201018 DL Memor EdgeE BT 2D WM6 1 USB Host Cradle 944201019 DL Memor 802 11g BT 1DGS CE5 94A151122 944201022 DL Memor 802 11g BT 2D CE5 944201023 DL Memor EdgeA BT 1DGS WM6 1 944201024 DL Memor EdgeA BT 2D WM6E 1 Datalogic 944201001 DL Memor 000 904 416 MIN FNC Memor Single 944201003 DL Memor 001 904 416 BT MIN FNC sete 944201005 DL Memor 600 904 416 WIFI6 MIN FNC 94A151116 944901007 DL Memor 800 904 416 WIFI MIN FNG The Datalogic Memor Single Ethernet USB Host Cradle can be used with device software versions starting at the following WinMobile Ver 4 01 Build 1 02 00 20090918 WinCE Ver 4 01 Build 3 12 105 20090918 CHARGING AND COMMUNICATION By inserting the Datalogic Memor into the cradle data can be transmitted to the host and batteries will automatically begin charging In addition a spare battery can be charged by inserting it into the slot at the back of the cradle as shown in the following figure Data Trans
6. ernet hub D Power supply Please remove the mobile computer before switching between Ethernet and USB to prevent inadvertent device lock up or damage The actual data transfer speed can be appreciably lower than the maximum theoretical speed USB Connection The Datalogic Memor Single Ethernet USB Host Cradle can be connected to the host by means of any standard Mini USB cable 1 Place the switch in USB position 2 plug in USB cable and optional power 3 load the Datalogic Memor in the cradle Figure 7 USB Connection A Host Computer C Datalogic Memor Single Ethernet USB Host Cradle B Std Mini USB i e D Power Supply only necessary 94A051016 CAB 421 for battery charging Please remove the mobile computer before switching between USB and Ethernet to prevent inadvertent device lock up or damage Connection is 2 0 USB standard compliant The actual data transfer speed can be appreciably lower than the maximum theoretical speed RS232 Connection The Single Ethernet USB Host Cradle can be connected to the host by means of any standard null modem cable The 9 pin female D Sub connector must be connected to the RS232 port of the cradle Once the host has been turned on insert the Datalogic Memor mobile computer into the cradle A Figure 8 RS232 Connection A Host Computer C Datalogic Memor Single Ethernet USB Host Cradle B Null Modem cable D Power Supply only necessary for
7. mission and Mobile Computer Battery Charging Spare battery Charge Slot with Spare Battery Inserted Figure 2 Datalogic Memor Single Ethernet USB Host Cradle and Communication SPARE BATTERY REMOVAL Figure 3 Correct removal Figure 4 Incorrect removal LED INDICATORS The LEDs positioned on the front part of cradle see figure below indicate the cradle and spare battery charger status Spare Battery Power LED Charger LED DATALOGIC Figure 5 LED Indicators Front LED indicators STATUS Red Constant Spare battery charging Spare battery charge Green Constant completed Charger Power Green a ower Green powered During charging the LED may turn off to indicate a temporary suspension of charging Ethernet Connector LED Indicators Ethernet Solid Green Green 100 Mbps connection 00 Mbps connection Green LED right 10 Mbps connection Off Ethernet No link established Yellow Solid Yellow Link established Flashing Yellow Link activity LED left CONNECTIONS AN Connections should always be made with power OFF CAUTION Ethernet Connection 1 Place the switch in Ethernet position 2 connect the Ethernet cradle to an Ethernet hub or a port on the host device 3 connect the Power jack to a power supply Figure 6 Ethernet Connection A Datalogic Memor Single C UTP CAT 5E cable Ethernet USB Host Cradle recommended use B Eth